| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.8 L+₹2.0 L (5.55%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L2 | Rejected-Finance Bidder quated 2nd lowest amount. | |
| 3 | L3₹38.8 L+₹2.1 L (5.61%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L3 | Rejected-Finance Bidder quated 3rd lowest amount. | |
| 4 | L4₹40.1 L+₹3.4 L (9.17%)Rejected-Finance 712 GORAKHPUR JABALPUR 482001 MP | JABALPUR | MADHYA PRADESH | 482001 | L4 | Rejected-Finance Bidder quated 4th lowest amount. | |
| 5 | L5₹40.9 L+₹4.1 L (11.2%)Rejected-Finance D 154 ADARSH NAGAR NARMADA ROAD JABALPUR MP 482001 | JABALPUR | MADHYA PRADESH | 482001 | L5 | Rejected-Finance Bidder quated 5th lowest amount. |
| Sl No | Description | Qty | Unit | M/s Ajayshwar Singh Rana L8 | RAVINDRA ELECTRICAL L1 | RAVI TEJ BUILDERS L4 | RAM ASSOCIATES L5 | ABHISHEK ENTERPRISES L2 | M/S N K SONKAR L7 | Sachdeva Enterprises L3 | MAYANK CONSTRUCTIONS L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified and directed.
Note: Painting work measured and paid seperately under respective items. | 2,495 | Per Point | 15 ₹37,425 | 5 ₹12,475 Lowest | 10 ₹24,950 | 5 ₹12,475 Lowest | 10 ₹24,950 | 5 ₹12,475 Lowest | 20 ₹49,900 | 11.11 ₹27,719.45 |
| 2.00 | Taking down carefully any type of old unserviceable submain wiring with PVC conduit surface / concealed or wooden battens etc and making good the disturbed surfaces to match with the existing surface complete all as specified and directed. | 1,450 | RM | 8 ₹11,600 | 7 ₹10,150 | 10 ₹14,500 | 5 ₹7,250 Lowest | 10 ₹14,500 | 5 ₹7,250 Lowest | 10 ₹14,500 | 10 ₹14,500 |
| 3.00 | M&L for Sub main wiring single core PVC Insulated cable two run of size 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 19/20 mm dia with all conduit accessories and one run of 1.5 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and directed.
Note : - Two run of 1.5 Sqmm,one run of 1.5 Sqmm cable & one run of PVC conduit shall be measured as one unit run. | 140 | RM | 150 ₹21,000 Lowest | 190 ₹26,600 | 170 ₹23,800 | 255 ₹35,700 | 150 ₹21,000 Lowest | 220 ₹30,800 | 150 ₹21,000 Lowest | 176.76 ₹24,746.4 |
| 4.00 | M&L for Sub main wiring single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 19/20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and directed.
Note : - Two run of 4 Sqmm , one run of 4.0 Sqmm & one run of PVC conduit shall be measured as one unit run. | 550 | RM | 400 ₹2,20,000 | 320 ₹1,76,000 | 310 ₹1,70,500 | 402 ₹2,21,100 | 300 ₹1,65,000 | 300 ₹1,65,000 | 250 ₹1,37,500 Lowest | 354.54 ₹1,94,997 |
| 5.00 | M&L for Sub main wiring single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed.
Note : - Two run of 6 Sqmm , one run of 6 Sqmm cable & one run of PVC conduit shall be measured as one unit run. | 580 | RM | 485 ₹2,81,300 | 430 ₹2,49,400 | 450 ₹2,61,000 | 535 ₹3,10,300 | 375 ₹2,17,500 | 450 ₹2,61,000 | 300 ₹1,74,000 Lowest | 487.87 ₹2,82,964.6 |
| 6.00 | M&L for Sub main wiring single core PVC Insulated cable three run of size 10.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and two run of 10.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed.
Note : - Three run of 10 Sqmm , two run of 10 Sqmm cable & one run of PVC conduit shall be measured as one unit run. | 180 | RM | 850 ₹1,53,000 | 950 ₹1,71,000 | 720 ₹1,29,600 | 1,120 ₹2,01,600 | 450 ₹81,000 Lowest | 690 ₹1,24,200 | 450 ₹81,000 Lowest | 1,295.95 ₹2,33,271 |
| 7.00 | Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into the concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside including Modular sheet cover with frame plate of required module size for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces One light Point/fan point controlled by one switch complete all as specified and directed. | 800 | Per Point | 595 ₹4,76,000 | 650 ₹5,20,000 | 490 ₹3,92,000 | 435 ₹3,48,000 Lowest | 625 ₹5,00,000 | 600 ₹4,80,000 | 600 ₹4,80,000 | 577 ₹4,61,600 |
| 8.00 | ~Ditto~ all as per srl item No. 7 but for one Bell Point controlled by one switch. | 50 | Per Point | 550 ₹27,500 | 600 ₹30,000 | 550 ₹27,500 | 435 ₹21,750 | 625 ₹31,250 | 400 ₹20,000 Lowest | 600 ₹30,000 | 580 ₹29,000 |
| 9.00 | ~Ditto~ all as per srl item No. 7 but for one socket point 5 Amp controlled by one switch on same board. | 160 | Per Point | 350 ₹56,000 | 80 ₹12,800 | 150 ₹24,000 | 55 ₹8,800 Lowest | 200 ₹32,000 | 200 ₹32,000 | 150 ₹24,000 | 90 ₹14,400 |
| 10.00 | ~Ditto~ all as per srl item No. 7 but for one socket point 5 Amp controlled by one switch on Independent board. | 160 | Per Point | 550 ₹88,000 | 600 ₹96,000 | 550 ₹88,000 | 435 ₹69,600 Lowest | 700 ₹1,12,000 | 600 ₹96,000 | 600 ₹96,000 | 600 ₹96,000 |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
1 Sept 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE, GE (P) No 1 Jabalpur
GE (P) NO 1, Ridge Road, Jabalpur-482001
REPAIR MAINTENANCE OF E/M SERVICES AND ALLIED WORK OF MD ACCN UNDER GE P NO 1 JABALPUR
2026_MES_782595_1
8625/KH/E8
Open Tender
Civil Works
Item Rate
180 days
GE (P) NO 1, Ridge Road
D, b(i)
7 documents required · 7 mandatory
₹500
GE (P) No 1 Jabalpur
₹1 L
5 Nov 2026
4 Aug 2026
8 Sept 2026
4 Aug 2026
1 Sept 2026
18 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified and directed.
Note: Painting work measured and paid seperately under respective items. | 2,495 | Per Point | - | - |
| 2 | Taking down carefully any type of old unserviceable submain wiring with PVC conduit surface / concealed or wooden battens etc and making good the disturbed surfaces to match with the existing surface complete all as specified and directed. | 1,450 | RM | - | - |
| 3 | M&L for Sub main wiring single core PVC Insulated cable two run of size 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 19/20 mm dia with all conduit accessories and one run of 1.5 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and directed.
Note : - Two run of 1.5 Sqmm,one run of 1.5 Sqmm cable & one run of PVC conduit shall be measured as one unit run. | 140 | RM | - | - |
| 4 | M&L for Sub main wiring single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 19/20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified and directed.
Note : - Two run of 4 Sqmm , one run of 4.0 Sqmm & one run of PVC conduit shall be measured as one unit run. | 550 | RM | - | - |
| 5 | M&L for Sub main wiring single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed.
Note : - Two run of 6 Sqmm , one run of 6 Sqmm cable & one run of PVC conduit shall be measured as one unit run. | 580 | RM | - | - |
| 6 | M&L for Sub main wiring single core PVC Insulated cable three run of size 10.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and two run of 10.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed.
Note : - Three run of 10 Sqmm , two run of 10 Sqmm cable & one run of PVC conduit shall be measured as one unit run. | 180 | RM | - | - |
| 7 | Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into the concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside including Modular sheet cover with frame plate of required module size for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces One light Point/fan point controlled by one switch complete all as specified and directed. | 800 | Per Point | - | - |
| 8 | ~Ditto~ all as per srl item No. 7 but for one Bell Point controlled by one switch. | 50 | Per Point | - | - |
| 9 | ~Ditto~ all as per srl item No. 7 but for one socket point 5 Amp controlled by one switch on same board. | 160 | Per Point | - | - |
| 10 | ~Ditto~ all as per srl item No. 7 but for one socket point 5 Amp controlled by one switch on Independent board. | 160 | Per Point | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
8625TenderDocuments.pdf
Tender Documents • 1.01 MB
BOQ_876825.xls
BOQ • 5.44 MB
8625Corrigendum.pdf
PDF • 0.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .