Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 184 NEAR GOODWAY TAILORS PRITHVIPURA RASAL ROAD BRIDGE JODHPUR RAJASTHAN 342006 | JODHPUR | RAJASTHAN | 342006 | ₹1.4 Cr Quoted ₹1.2 Cr | L1 | Accepted-AOC Awarded as per TPC Resolution No. 1 dated 11.03.2022 |
| 2 | L2₹1.2 Cr+₹2.0 L (1.66%)Rejected-Finance A T ROAD EVERLITE HOUSE PANITOLA LAIPULI TINSUKIA ASSAM 786183 | TINSUKIA | ASSAM | 786183 | ₹1.2 Cr+₹2.0 L (1.66%) | L2 | Rejected-Finance Work awarded to L1 bidder as per TPC Resolution No. 01 dated 11.03.2022 |
| 3 | L3₹1.2 Cr+₹3.0 L (2.57%)Rejected-Finance | ₹1.2 Cr+₹3.0 L (2.57%) | L3 | Rejected-Finance Work awarded to L1 bidder as per TPC Resolution No. 01 dated 11.03.2022 |
| 4 | L4₹1.3 Cr+₹15.6 L (13.2%)Rejected-Finance 215 TOWER A SPAZEDGE SOHNA ROAD SECTOR 47 GURGAON HARYANA 122002 | GURUGRAM | HARYANA | 122002 | ₹1.3 Cr+₹15.6 L (13.2%) | L4 | Rejected-Finance Work awarded to L1 bidder as per TPC Resolution No. 01 dated 11.03.2022 |
| 5 | L5₹1.3 Cr+₹15.6 L (13.2%)Rejected-Finance | ₹1.3 Cr+₹15.6 L (13.2%) | L5 | Rejected-Finance Work awarded to L1 bidder as per TPC Resolution No. 01 dated 11.03.2022 |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
31 Jul 2021, 12:00 pmClosed
CGM PPnD
First floor, Bijulee bhawan, Paltanbazar, Ghy-01
Construction of One no. of 132 KV Line bay at 132/33 KV Azara substation along with associated PLCC work at 400/220/132/33 KV Kukurmara (Mirza) substation
2021_AEGCL_22139_1
AEGCL/MD/Tech-963/Azara Bay/2021/BID
Open Tender
Electrical Works
Turn-key
240 days
guwahati
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹1.9 L
Yes
26 Mar 2022
7 Jul 2021
2 Aug 2021
7 Jul 2021
31 Jul 2021
21 Jul 2021
7 Jul 2021 - 17 Jul 2021
Amount
Circuit Breaker
145 kV, 3150A, SCR 40kA for 1 sec, outdoor type, 3-ph gang operated SF6 Circuit Breaker, complete with terminal connector, operating mechanism & support structure
Control and Relay Panel
Indoor floor mounted, simplex type Control & Relay Panel with mimic & annunciation panel for 132kV feeder as per specification comprising of the C&R panels shall be complete with Numeric Relays as per the Technical Specifications & shall be compatible for SCADA/SAS as open protocol.
Current Transformer
145 kV outdoor type live tank single phase Current Transformers 800-400/1-1-1-1 A ( Feeder CT)
Capacitor Voltage Transformer
145 kV , 1-ph, Capacitor Voltage Transformer ( CVT)
145kV, 1250A, SCR 40kA for 1 sec, 3-ph gang operated Horizntal Centre Break ( HCB) , outdoor type , motor operated Isolators including solid core post insulators, mounting structure complete with nuts, bolts , washers and foundation bolts
132 kV Isolator With single Earth Switch
132 kV IsolatorWithout Earth Switch
132 kV Isolator Without Earth Switch (Tandem Type)
Lighting Arresotor
120kV, 10kA metal oxide type, heavy duty, station class-3 Lightning Arrester complete with Surge Counter & flexible copper connecting lead
Post Insulator
132 KV Post Insulator with terminal connectors.
Mounting structures of all equipment including nuts, bolts & washers
132 KV Current Transformers
Capacitance Voltage Transformer
Lightning Arrester
Power and Control Cables
Power Cables - 4 C, 4 sqmm
Power Cables - 4 C, 6 sqmm
Control Cables - 4 C, 2.5 sqmm
Control Cables - 7 C, 2.5 sqmm
Control Cables - 12 C, 2.5 sqmm
PowerConductor
(ACSR panther)
Disc Insulator String complete with all hardware, fittings, clamps etc.
10 Disc Tension Insulator String
9 Disc Suspension Insulator String
Earth mat conductor and electrodes
50 x 10 mm GI Flat
40 mm dia. rod electrodes
PLCC Equipments
EPAX (8x24) with 24 nos telephone, cable etc
Digital Protection Coupler with PLC Terminal
LMU / LMDU
HF Cable , 75 ohms (balanced)
132kV , 800A, 40 KA SCR, wave trap
Marshalling kiosk and other items
Bay Marshalling Kiosk
Description of Work / Item(s)
Amount
Circuit Breaker
145 kV, 3150A, SCR 40kA for 1 sec, outdoor type, 3-ph gang operated SF6 Circuit Breaker, complete with terminal connector, operating mechanism & support structure
Control and Relay Panel
Indoor floor mounted, simplex type Control & Relay Panel with mimic & annunciation panel for 132kV feeder as per specification comprising of the C&R panels shall be complete with Numeric Relays as per the Technical Specifications & shall be compatible for SCADA/SAS as open protocol.
Current Transformer
145 kV outdoor type live tank single phase Current Transformers 800-400/1-1-1-1 A ( Feeder CT)
Capacitor Voltage Transformer
145 kV , 1-ph, Capacitor Voltage Transformer ( CVT)
145kV, 1250A, SCR 40kA for 1 sec, 3-ph gang operated Horizntal Centre Break ( HCB) , outdoor type , motor operated Isolators including solid core post insulators, mounting structure complete with nuts, bolts , washers and foundation bolts
132 kV Isolator With single Earth Switch
132 kV IsolatorWithout Earth Switch
132 kV Isolator Without Earth Switch (Tandem Type)
Lighting Arresotor
120kV, 10kA metal oxide type, heavy duty, station class-3 Lightning Arrester complete with Surge Counter & flexible copper connecting lead
Post Insulator
132 KV Post Insulator with terminal connectors.
Mounting structures of all equipment including nuts, bolts & washers
132 KV Current Transformers
Capacitance Voltage Transformer
Lightning Arrester
Power and Control Cables
Power Cables - 4 C, 4 sqmm
Power Cables - 4 C, 6 sqmm
Control Cables - 4 C, 2.5 sqmm
Control Cables - 7 C, 2.5 sqmm
Control Cables - 12 C, 2.5 sqmm
PowerConductor
(ACSR panther)
Disc Insulator String complete with all hardware, fittings, clamps etc.
10 Disc Tension Insulator String
9 Disc Suspension Insulator String
Earth mat conductor and electrodes
50 x 10 mm GI Flat
40 mm dia. rod electrodes
PLCC Equipments
EPAX (8x24) with 24 nos telephone, cable etc
Digital Protection Coupler with PLC Terminal
LMU / LMDU
HF Cable , 75 ohms (balanced)
132kV , 800A, 40 KA SCR, wave trap
Marshalling kiosk and other items
Bay Marshalling Kiosk
Description of Work / Item(s)
Amount
Erection, testing & commissioning of Circuit Breakers including laying & terminating of LT power and control cables as required
132 kV Gang operated SF6 Breakers
Erection, testing & commissioning of Control & Relay Panels including laying & terminating of LT power and control cables as required.
For 132 kV Feeder. (Simplex Panels)
Erection, testing & commissioning of Current transformers including laying & terminating of control cables as required
132 kV, 800-400/1-1-1 Line CT
Erection, testing & commissioning of Voltage Transformers/CVT including laying control cables as required
132 kV CVT
Erection, testing & commissioning of Isolators including laying & terminating of LT power and control cables as required
132 kV With single Earth Switch
132 kV Without Earth Switch
132 kV Without Earth Switch (Tandem Type)
Erection, testing & commissioning of Lightning Arrester
132 kV Lightning Arrester
Erection, testing & commissioning of Post Insulator
132 kV Post insulator
Erection of mounting structures as required for Circuit Breakers including construction of foundations and supply of all foundation materials.
132 kV Gang operated SF6 Breakers
Erection of mounting structures as required for Current transformers including construction of foundations and supply of all foundation materials (as per Drg enclosed for bidding purpose)
Erection of mounting structures as required for Voltage transformers /CVT including construction of foundations and supply of all foundation materials
132 kV CVT
Erection of mounting structures as required for Isolators transformers including construction of foundations and supply of all foundation materials
132 kV With single Earth Switch
132 kV Without Earth Switch
132 kV Without Earth Switch (Tandem Type)
Erection of mounting structures as required for Lightning Arrester including construction of foundations and supply of all foundation materials.
132 kV Lightning Arrester
Erection of mounting structures as required for Post Insulators including construction of foundations and supply of all foundation materials
132 kV Post insulator
PLCC Equipment
Commissioning of Azara-Mirza PLCC link including Installation and commissioning of all equipment complete with erection, laying & terminations of all cables
Hoisting of insulatoretc
Hoisting of insulator strings, stringing of Conductors , jumpering of equipments CB, CT, CVT Isolator, LA including supply of clamps, connectors , etc.
Earthing
Installation of earthing system with GI flats, electrodes etc.
Earthwork in filling, levelling, compacting, grading etc as per site condition and technical Specification
Supply of earth for filling
Filling, levelling, compacting, grading etc as per site condition and technical Specification
Construction of Cable Trenches including supply of all materials and labour as per specification and drawing
Type B (1100 x 1050 mm)
Type C (800 x 1350 mm)
Type D (Sand filled)
Integration of Control Relay Panel into the existing Substation Automation System (SAS)
Bay marshalling kiosk
Erection of Bay Marshalling Kiosk as per drawings and specifications including construction of foundation inclusive of supply of all foundation materials and labour.
Anjali Constructions
POWER NETWORK ENGINEERS PRIVATE LTD
HI-TECH CORPORATION
Mega Electricals
Deejay System Consultants Pvt. Ltd.
Jayanta Khaund
Anjali Constructions
POWER NETWORK ENGINEERS PRIVATE LTD
Jayanta Khaund
Deejay System Consultants Pvt. Ltd.
HI-TECH CORPORATION
Everlite Engineering Industries
Deejay System Consultants Pvt. Ltd.
Everlite Engineering Industries
Anjali Constructions
Jayanta Khaund
POWER NETWORK ENGINEERS PRIVATE LTD
Mega Electricals
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .