Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹21.9 L+₹43,799.20 (2.04%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹22.3 L+₹88,173.20 (4.11%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹22.6 L+₹1.2 L (5.45%)Rejected-Finance H NO 113 APR COLONY KATANGA CANTT JABALPUR M P PIN 482001 | JABALPUR | MADHYA PRADESH | 482001 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
18 May 2020, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
CLEANING OF OVERHEAD TANK AND ALLIED WORKS UNDER GE (WEST) JABALPUR
2020_MES_333372_1
8209/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender document
5 documents required · 5 mandatory
₹500
Yes
GE (West) Jabalpur
₹44,000
16 Jun 2020
12 Mar 2020
20 May 2020
12 Mar 2020
18 May 2020
26 Mar 2020
Amount
Cleaning and removing all silt, dirt, mud, etc. from inside the tank and from mouth of inlet/ outlet pipe and disposal of the same to a distance not exc. 50 m, and applying one coat of white wash on internal surfaces including preparation of old/wet surface and sign writing with white enamelled paint on black background (height of letters minimum 7.50 cm) on column showing capacity of tank and date of cleaning complete for the following :- Note Mechanized cleaning and disinfection of Water Storage Tank : 1. Mechanized Dewatering of water storage tank. 2.Removal of sluge lyng on the bottom ofwater storage tank through special sludge pumps. 3.Cleaning of internal walls of water storage tank through High Pressure rotary Jets 4.Vaccum cleaning of the floor of water storage tank through industrial vaccum cleaners. 5.Spray of H2 O2 inside the tanks as an antibecterial agent. 6. UV radiation of the tank. 7.Spray of bleaching powder in prescribed quantity after final cleaning of the tank.
More than 01 Lac Gln OHTs & less than 3.5 Lac Gln OHTs having staging between 18m-21m.
01 Lac gallons capacity OHTs having staging between 18m- 21m.
0.5 Lac gallons capacity OHTs having staging between 18 m -21 m.
Below 0.5 Lac Gln capacity OHTs having staging between 12 m -18 m
Cleaning and removing all silt, dirt and mud etc from inside the reservoirs and from mouth of inlet/outlet pipe and disposal of the same to a distance not exceeding 50 m and applying one coat of white wash on internal surfaces including preparation of old/wet surfaces and sign writing on wall surface out side with white enamelled paint (height of letters minimum 7.5 cm) on black enamelled paint back ground surface for the following :- Note Mechanized cleaning and disinfection of Water Storage Tank : 1. Mechanized Dewatering of water storage tank. 2.Removal of sluge laying on the bottom ofwater storage tank through special sludge pumps. 3.Cleaning of internal walls of water storage tank through High Pressure rotary Jets 4.Vaccum cleaning of the floor of water storage tank through industrial vaccum cleaners. 5.Spray of H2 O2 inside the tanks as an antibecterial agent. 6. UV radiation of the tank. 7.Spray of bleaching powder in prescribed quantity after final cleaning of the tank.
(a) 10 Lac gallons capacity under ground sump having 2 cum silt (approx).
(b) 5 lac gallon capacity under ground/over ground sump having 1cum silt (approx).
(c) 01 lac gallon to 2 lakh gallon capacity under ground sump having 1 cum silt in each compartment (approx).
(d) Less than 01 Lac gallons capacity under ground sump having 0.5 cum silt.(approx)
Mechanized cleaning and disinfection of following capacity Water Storage Tank : 1. Mechanized Dewatering of water storage tank. 2.Removal of sluge laying on the bottom ofwater storage tank through special sludge pumps. 3.Cleaning of internal walls of water storage tank through High Pressure rotary Jets 4.Vaccum cleaning of the floor of water storage tank through industrial vaccum cleaners. 5.Spray of H2 O2 inside the tanks as an antibecterial agent. 6. UV radiation of the tank. 7.Spray of bleaching powder in prescribed quantity after final cleaning of the tank. Note writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed.
(a) 500 ltr capacity
(b)1000 ltr capacity
(c) 2000 ltr capacity
(d) 5000 ltr capacity
(e) Exc 250 and n exc 500 ltr capacity
Supplying , fixing & Hoisting and fixing in position and connecting, in repairs, 500 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed of Make Sintex/ Polycon/Polywell.
Supplying , fixing & Hoisting and fixing in position and connecting, in repairs, 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed of Make Sintex/ Polycon/Polywell.
Supplying , fixing & Hoisting and fixing in position and connecting, in repairs, 2000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed of Make Sintex/ Polycon/Polywell.
Supplying , fixing & Hoisting and fixing in position and connecting, in repairs, 5000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed of Make Sintex/ Polycon/Polywell.
S&F, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -210 Gms)
S&F, in repair, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -210 Gms)
S&F, 40mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -690 Gms)
S&F, in repair, 25mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -455 Gms)
S&F in repair, 50mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
S&F, in repair, HDPE water storage tank lid black (with arrangement for locking for 500 litres capacity tank complete all as specified and directed.
S&F, in repair, HDPE water storage tank lid black (with arrangement for locking for 1000 litres capacity tank complete all as specified and directed.
S&F, in repair, HDPE water storage tank lid black (with arrangement for locking for 2000/5000 litres capacity tank complete all as specified and directed.
Supply and fixing in repair pressure gauge 150 mm fitting with MS clamp complete all as specified and directed
S&F in repair Flanged jointing for 150 mm bore including necessary nut, bolt washer & fibre / rubber gasket complete all as specified and directed.
Supply and fixing in repairs MS Nut bolt washer 1/2" x 2 1/2"
Supply and fixing in repairs MS Nut bolt washer 1/2" x 3"
Supply and fixing in repairs D Joint for 80 mm CI pipe
Supply and fixing in repairs D Joint for 100 mm CI pipe
Supply and fixing in repairs D Joint for 150 mm CI pipe
Supply and fixing in repairs D Joint for 200 mm CI pipe
S&F, in repair, Steel rolling shutters, thickness of laths 1mm thick, with out ball bearing, as specified including top cover, an-choring rod, hasp and staple including one shop coat of primer, and erected in position as indicated, push pull or manual type complete all as specified and directed.
S&F, in repair, Steel rolling shutters, thickness of laths 1.25mm thick, with ball bearing as specified including top cover, an-choring rod, hasp and staple including one shop coat of primer and erected in position as indicated, but gear operater type wirh bevel gear box and crank handle complete all as specified and directed.
Maintenance and overhauling of Steel rolling shutters (without taking down) opening size 3 to 8 Sqm by opening the top hood and cleaning, oiling, greasing and making free flow of shutters on its guide channels complete including cleaning, oiling, greasing of gear assembly all as directed and including two coats of synthetic enamel paint after preparatiopn of surfaces complete all as specified and directed.
Maintenance and overhauling of Steel rolling shutters (without taking down) opening size 8 to 12 Sqm by opening the top hood and cleaning, oiling, greasing and making free flow of shutters on its guide channels complete including cleaning, oiling, greasing of gear assembly all as directed and including two coats of synthetic enamel paint after preparatiopn of old surfaces complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering cement plaster 10mm thick in cement mortar (1:6) on brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering cement plaster 15mm thick in cement mortar (1:4) on brick work or concrete surfaces, finished even and smooth without using extra cement mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed. ( Note :- Water proofing compound shall be measured and paid separately.)
M&L for rendering cement plaster 5mm thick in cement mortar 1:4 on fair faces of concrete in ceilings, chajjas, fins facia etc. finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered or un-plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M&L for preparing new plastered or un-plastered surfaces and applying three coats of white wash on walls complete all as specified and directed.
Supply only, integral water proofing compound. complete @ 3 % by weight cement roof and parapet/ vertical surfaces and like complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc 0.5 cum, getting out, in soft/loose soil including returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50m and making good surfaces complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-2, using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
S&F , Pre Stressed, pre cast RCC ( M-25 Grade ) column of size 150mm X 150mm and 2.40 meter height with contineous vertical groove of sizes 60mmx35mm at two sides of column to receive the precast panels, including reinforced with 7 Nos wires of 4mm dia high tensile corbonized steel, surfaces finished even and smooth including errecting in position all as specified and as directed.
S&F, Pre Stressed, pre cast RCC ( M-25 Grade ) panels of 2100mmx300mm size and 50mm thick, reinforced with 4 Nos wires of 4mm dia high tensile corbonized steel, including fixing in position in between column grooves and jointing and flush pointing of all horizontal and verticle joints of panels with cement mortar 1:3 complete all as specified and as directed.
M&L for preparation of old plastered surfaces of wall and applying one coats of cement base paint complete all as specified and directed.
Dismantling posts or struts ( wood, RCC or steel ) any section post embeded in concrete , brick work, masonry etc including taking embeded portion and making good disturbed surfaces complete all as specified and directed.
Dismantling barbed wire fencing mesh, fixed with steel or wood fillets of any type complete all as specified and directed..
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F mild steel work in tubular trusses, posts, main and cross beams, hip and jack rafters, purlins, including special shaped washer etc. complete using ERW or induction butt welded tubes, conforming to IS 1161-1979, Gde St-240 complete all as specified and directed.
S&F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe 410-W (Gde-E-250) quality-complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi corrugated etc.) sheets in roof covering complete all as specified and directed.
S&F, in repair, pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Dismantling/ taking down existing CI 150 mm bore pipe flanged Class ‘B’ chocked washed out .pipe for over head tank and re-fixing the same in position after cleaning thoroughly including flange gasket joints complete
ditto all as above items but 100mm bore complete.
S&F Fittings for spigot socketed/flanged cast iron pipes 80 to 300 mm bore such as bends (any type radius and angle), tapers and type (straight, bend, increasing, decreasing or double socket etc) tee pieces, single branch, `Y' junction, double branch, cross (all sockets or socket and spigot),collars, caps and plugs complete.
M&L for making foundation thrust blocks/support pillars for holding pipe line/clamp support etc by PCC 1:2:4 type B1 (using 20mm graded aggregate size) and using extra cement making good to surfaces including dismantling of old trust block complete all as specified and directed.
S&F Clamps, support, back plates fabricated from structural steel sections including nuts bolts, washers, welding, bending cold or hot, drilling holes for bolts, sockets, etc any shape or size as directed conforming to Fe 410-0 or Fe 310-0
M&L for earth continuity aluminium conductor or main earthing lead fixed to wall on chases or any other indicated situation for earthing etc to connect lighting arrestor on the top of the OHT staging maximum 18/21 meter and strip 25 x 3.15 mm.
M&L for earth continuity GI conductor or main earthing lead fixed to wall on chases or any other indicated situation for earthing etc to connect lighting arrestor on the top of the OHT staging maximum 18/21 meter and strip 32x6mm.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including, 3 NOS, 8mm dia 25mm long hex, head screw complete.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised iron earth strip of size 32mm width 6 mm thickmeans of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical steel all as shown in electrical plate No 5 of MES Schedule Part-I connecting to earthing test point and testing on completion with and including 15 mm bore light grade G.I. protection pipe (0.5 metre beyond pit to main switch) RCC 1:2:4 type B1 40 mm thick cover reinforced with 6 mm dia M.S. bars 3 Nos both ways with lifting hook made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, earthing lead from earth plates to pipe equipment earth point (upto 7.5 m long) common salt and charcoal filling, necessary excavation and earth work, complete.
S&F, in repair, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Dismantling and taking down existing unserviceable/ rusty galvanized iron flat of size pulley GI wire indicator as found at site of over head tanks and provision of new float 300mm dia made out of copper sheet of suitable gauge clamped with 25 x3 mm copper strip duly welded.
Dismantling and taking down existing water meter level indicator board scraping , painting and rewritting the letters and figures (min hight 50mm ) with of black back ground indicating capacity in gallon / ltr divided in ten parts and refixing the same in position after painting and rewriting complete. Colour bold letters etc complete and as per directed by Enigneer in Charge.
Ditto all as above items but U/G sump complete
Cutting of grass and bushes and surface dressing around in pump house of AGE E/M (W/S) upto 3 metres from the end of plinth protection of bldg and removing the rubbish to distance upto 50 metre complete all as specified & directed by Engineer - in - Charge.
S & F in repair gate / globe valves cast copper alloy screwed both end down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed bore of following size : -
( a ) 20 mm bore.
( b ) 25 mm bore.
(c ) 40 mm bore
(d) 50 mm bore
Sachdeva Enterprises
nevi constructions
DEEPAK CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .