Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹3.9 L
EMD Value
₹7,850
Closing Date
7 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE Civil Pune
O/O EE Civil, BSNL Civil Dn MHS TE Pune-01
Maintenance and repairs to BSNL buildings under the jurisdiction of DGM East Pune for the year 2022 23
2022_BSNL_130852_1
e-8/EEC(P)/BSNL/2022-23
Open Tender
Civil Works - Buildings
Item Rate
365 days
Pune
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Accounts Officer Cash BSNL Pune
₹7,850
16 Dec 2022
1 Oct 2022
11 Oct 2022
1 Oct 2022
7 Oct 2022
1 Oct 2022
Amount
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Repairs to full glass door with aluminium frame at 3rd floor MHS Bhavan by removing the shutter from its position, replacing the pivots, fixing Aluminium corner brackets of approved quality on both faces using nut & bolts of suitable size at four corners of shutter to ensure proper fixity and alignment of vertical door styles & refixing the door shutter to its original position with due care etc. all complete as directed by Engineer-in-charge.
Repairs to aluminium door shutter by removing the shutter from its position, fixing Aluminium corner brackets of approved quality on both faces using nut & bolts of suitable size at four corners of shutter to ensure proper fixity and alignment of vertical door styles & refixing the door shutter to its original position etc. all complete as directed by Engineer-in-charge.( Cost of hinges etc if required will be paid seperatly) a) Single shutter aluminium door of size up to 1.0 x 2.10 m
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 100x75x4 mm
Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Removing of choke up inside building in kitchen, bath room and WC waste pipe line from inside the building so as to make it opertional etc all complete as directed by Engineer in Charge.
Checking of drainage line on the external wall face upto G+2 bldg height from cowl to gully trap, removing the plants and roots, if any, pouring acid, sealing holes by cement mortar 1:2, removing blockages in the pipes, sealing the joints with cement mortar, providing missing door caps etc complete with help of ladder/ zoola etc complete as directed by Engineer-in-Charge. (The line shall be maintained for six months)
Cleaning of drainage line including removing blockages in external drainage line, cleaning of chambers, taking out sludge / rubbish etc / sealing of rodent entry points with cement concrete all as per the direction of Engineer-in-Charge. (The line shall be maintained for six months)
Attending leakages in PVC water tank including disconnecting, emptying the tank and reparing by PVC welding and replacing in position, making all connections, checking etc complete as directed by Engineer in charge. Capacity upto 2000 Lit
Capacity 2001 to 5000 Lit
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall - a) 15 mm nominal outer dia. Pipes.
b) 20 mm nominal outer dia. Pipes.
c) 25 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work a) 40 mm nominal outer dia .Pipes.
b) 50 mm nominal outer dia .Pipes.
Providing and fixing gun metal gate valve/CPVC patti valve of approved quality (screwed end) : a) 25mm nominal bore
b) 40mm nominal bore
c) 50mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: a) 15 mm nominal bore.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. a) 15 mm nominal bore.
Providing and fixing PTMT bib cock of approved quality and colour. a) 15mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT stop cock of approved quality and colour. a) 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT pillar cock of approved quality and colour . a) 15mm nominal bore, 107 mm long. Weighing not less than 110 gms.
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. a) 15 mm nominal bore with 45 cm length.
Providing and fixing C.P. brass plumbing fixtures of approved make and quality etc complete as per direction of Engineer-in-charge. a) Pillar cock 15 mm nominal bore.
b) Handspray including pipe for health faucet
P/F gun metal gate valve with lever of approved quality. a) 15mm nominal bore
Dismantling of gate valve including stacking of useful materials within 50 metres lead. a) Up to 150 mm diameter
Repairing/ replacing of external 15mm to 50mm G.I. water supply pipe line from chock-up or other obstruction or for replacement of rusted G.I. Pipe line (cost of new G.I. Pipe to be paid separately) including removing the pipe from union/ bend/ sockets/ tees etc., clearing the chock-up and refixing the pipe to its original position, including cost of replacement of damaged sockets, bends, tees etc. (excluding unions), as required, for proper water supply using necessary scaffolding, jhoola, drop-cage etc. required to carry out the work complete, all as per direction of Engineer-in-charge.
Disposal of waste / malba by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km, complete as per directions of Engineer-in-Charge. (trip of one brass ie 2.83 Cum)
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with blEaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed withwater. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: a) G.S. Sheet
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm ( + 0.05 %), total coated thickness with zinc coating 120 gm per sqm as per IS:277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All kinds of soil.
b) Ordinary rock
c) Hard rock (blasting prohibited)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing, laying and jointing of Eco drain pipe conforming to IS:16098 of (M/S Supreme Co or equivalent) including required excavation, back filling after laying of pipe with necessary sockets and ruber rings (SN4) etc. complete as per the direction of Engineer-in-charge.a) 110 mm outer diametre Type B.
Repairs to exisiting drainage manhole of size 900x800mm including removing damaged part and repairing with necessary cement concrete 1:2:4, plaster with cement mortar 1:4, cement punning etc complete.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality- L D - 2.5-Rectangular shape 600x450 mm internal dimensions
Credit for the recovered items after dismantling or replacing the damaged items etc. (Note: 1. The rate quoted by the agency should be more than minimum reserve price. Any rate below the reserve price or no rate quoted will be considered as the rate of reserve price fixed and the amount of the item/s will be worked out on the basis of the minimum reserve price fixed for the item/s. 2. The materials will be handed over at site of work only, however BSNL reserves the right of using the recovered material, if required and the agency will not have any claim on any material if BSNL decides against handing over the items recovered from work at the quoted rate.) a) CP brass / bright brass / Gun metal fittings.
b) PVC flush tanks, bib cocks, stop cocks etc
N K CONSTRUCTION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .