Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹49.4 L+₹1.5 L (3.08%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹49.4 L+₹1.5 L (3.12%)Rejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹51.9 L+₹4.0 L (8.38%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | Not Admitted-Fee/PreQual/Technical GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | - | Not Admitted-Fee/PreQual/Technical Others-Contractor has withdrawan his participation from tender |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
21 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KHADKI
GE CENTRAL KHADKI RANGE HILLS ROAD KHADKI PUNE-411003
REPAIRS AND MAINTENANCE OF WALL MOUNTED LT DBs, OVER HEAD TRUNKING BUS BAR AND CONNECTED WORKS AT VARIOUS BUILDINGS OF 512 ABW UNDER AGE EM-II IN GE (CENTRAL) KHADKI.
2023_MES_600257_2
8821/E8 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
512 ABW area
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE CENTRAL KHADKI
₹98,000
Yes
28 Nov 2023
29 Aug 2023
23 Sept 2023
29 Aug 2023
21 Sept 2023
9 Sept 2023
29 Aug 2023 - 5 Sept 2023
Amount
Dismantling of MS top covers of exisiting trunking bus bars (at a height of appx. 30 feet above GL ), scrapping the inside of the busbar chamber to remove all dust particles and rusted iron particles, etc., vaccuming out all the dust particles inside the busbar chamber using a suitable vaccum cleaner and tightening of inter connections between copper bus bars within the trunking busbar complete,including refixing the covers and testing of the same after completion of the job for the full satisfaction of Engineer in charge complete all as specified and as directed.
Dismantling of over head trunking bus bar of any capacity/rating including all connected outgoing cables and plug in boxes at a height of upto 10 mtr GL complete all as specified and as directed.
Supply Installation, testing and commisioning of 1000 Amps aluminium sandwich type 3P4W 100%N and 50% internal earth busbar other than housing, operating voltage 415V, Insulation Voltage 1.1kV Rated Short time Current 18kA for 1Sec IP54, Mechanical Strength IK10 protection. bus duct should be Seismic zone -5 certified. The bus duct shall be type tested at a reputed test laboratory (certified by CPRI / ASTA / ERDA or any NABL accrediated lab) for the tests as per IEC-61439 Part-1 (Low voltage switchgear & controlgear assembly- General rules) & Part 6 (Bus bar trunking systems & bus ways); The rated current of busbar trunking systems is always rated at the average ambient temperature of 40°C (70x135 mm, enclosure thickness 1.6 mm GI) Insulation material used shall be of class F (155 degree) UL certified, ROHS Compliant, the conductors are made from an aluminum & tin plated at joints. provided with a monobloc pre-installed at the factory at one end. It should ensure the IP 54 degree of protection at the end of the run, all insulating plastic components comply with the incandescent wire test and have the standard degree of protection of IP 54 without using additional IP protection kits, the whole busbar is resistant to flame propagation and building penteration as pe IEC in compliance with standard 61439-6. Make L&T / Legrand complete all as specified and as directed. NOTE :- (i) Cost of any material and labour required for fixing of new bus bar in homogeneous with the existing old trunking bus bar is deemed to be included in the quoted rate. (ii) Fabrication of plug point on bus bar as per directed by engineer in charge.
Description all as per Serial item No.3 above but for Bus bar trunking capacity of 630 Amps.
Description all as per Serial item No.3 above but for Bus bar trunking capacity of 400 Amps.
Description all as per Serial item No.3 above but for Bus bar trunking capacity of 250 Amps.
Labour only for fabrication of flange end on bus bar as per directionof Engineer in charge.
Supply and fix end feed unit with switchgear of 250 Amps MCCB 4P, 25kA suitable for sandwich type bus bar trunking system with complete all as directed by Engr-In-Charge.
Supply and fix end feed unit with switchgear of 400 A MCCB 4P 36kA suitable for sandwich type bus bar trunking system with complete accessories all as directed by Engr-In-Charge.
Supply and fix end feed unit with switchgear of 630 A MCCB 4P 36kA suitable for sandwich type bus bar trunking system with complete accessories all as directed by Engr-In-Charge.
Supply and fix end feed unit with switchgear of 1000 A MCCB 4P 36kA suitable for sandwich type bus bar trunking system with complete accessories all as directed by Engr-In-Charge.
Supply and fix reducer for 1000 Amps to 630 Amps suitable for sandwich bus bar trunking system (of any rating) complete all as sapecified and as directed.
Supply and fix reducer for 630 Amps to 400 Amps suitable for sandwich bus bar trunking system (of any rating) complete all as sapecified and as directed.
Supply and fix reducer for 400 Amps to 250 Amps suitable for sandwich bus bar trunking system (of any rating) complete all as sapecified and as directed.
Supply and fix end cover suitable for sandwich type trunking bus bar system (of any rating) complete all as sapecified and as directed.
Dismantling of old plug in box, supply and fix rust proof steel sheet plug in box with hinged door housing four pole 32 Amp MCB "C" curve 10 KA rating solidly connected to high conductivity copper pin with provision of gland plates for cable entry having fully insulated plug in points which should be easily plugged in live bus bars of 32 Amps rating all as per direction of Engr-In-Charge.
Dismantling of old plug in box, supply and fix rust proof steel sheet plug in box with hinged doors housing four pole 40 Amp MCB "C" curve 10 KA rating solidly connected to high conductivity copper pin with provision of gland plates for cable entry having fully insulated plug in points which should be easily plugged in live bus bars of 40 Amps rating all as per direction by Engr-In-Charge.
Dismantling of old plug in box, supply, fix, test and commissioning rust proof steel sheet plug in box with side hinged doors housing 63 Amps, TPN, MCCB 25 kA, solidly connected to high conductivity tin plated copper insulated pin-on contacts with provision of gland plates for cable entry, having fully insulated plug in points which should be easily plugged in bus bars of 63 Amps rating complete all as specified and as directred.
Dismantling of old plug in box, supply, fix, test and commissioning rust proof steel sheet plug in box with side hinged doors housing 160 Amps TPN MCCB 25kA, solidly connected to high conductivity tin plated copper insulated pin-on contacts with provision of gland plates for cable entry, having fully insulated plugin points which should be easily plugged in bus bars of 160 Amps rating complete all as specified and as directred.
Dismantling of old plug in box, supply, fix, test and commissioning rust proof steel sheet plug in box with side hinged doors housing 250 Amps TPN MCCB 36kA, solidly connected to high conductivity tin plated copper insulated pin-on contacts with provision of gland plates for cable entry, having fully insulated plugin points which should be easily plugged in sandwitch type bus bars system complete all as specified and as directred.
Dismantling of old plug in box, supply, fix, test and commissioning rust proof steel sheet plug in box with side hinged doors housing 400 Amps TPN MCCB 36 kA, solidly connected to high conductivity tin plated copper insulated pin-on contacts with provision of gland plates for cable entry, having fully insulated plugin points which should be easily plugged in sandwitch type bus bars system complete all as specified and as directred.
Dismantling of old plug in box, supply, fix, test and commissioning rust proof steel sheet plug in box with side hinged doors housing 630 Amps TPN MCCB 36 kA, solidly connected to high conductivity tin plated copper insulated pin-on contacts with provision of gland plates for cable entry, having fully insulated plugin points which should be easily plugged in sandwitch type bus bars system complete all as specified and as directred.
Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from rolled structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holes for bolts, at any height, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint for mounting of bus bar trunking including fixing arrangements complete all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix MCCB thermal magnetic release four pole 25 KA 63 Amps Make Legrand Cat No 420053 /L&T /ABB with one way metal inclosure Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complate all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix MCCB thermal magnetic release four pole 25 KA 100 Amps Make Legrand Cat No 420055 /L&T /ABB with one way metal inclosure Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complate all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 25 KA 160 Amps Make Legrand Cat No 420057 /L&T /ABB with one way metal inclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complate all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 25 KA 200 Amps Make Legrand Cat No 420057 /L&T /ABB with one way metal inclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complate all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 35 KA 250 Amps Make Legrand Cat No 420057 /L&T /ABB with one way metal inclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complate all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 35 KA 400 Amps Make Legrand Cat No 420057 /L&T /ABB with one way metal inclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complate all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 35 KA 630 Amps Make Legrand Cat No 420057 /L&T /ABB with one way metal inclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complate all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables, supply and fix Industrial plug and socket board TP 32 Amps including plug top and MCB "C" curve 10 KA 32 Amps Make Legrand Cat No 5078 18 and 4086 58 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complete all as specified and as directed.
Removing of old main switch after disconecting the incoming and out going cables, supply and fix one way metal ednclosure all as per LegrandCat No 5077 93 /L&T/ABB and MCB "C" curve TPN 10 KA 32Amps Legrand Cat No 4086 80 /L&T/ABB and making conections of cables with suitable size nuts, bolt etc. including making good the disturbed suface of wall complate all as specified and as directed.
Supply, fixing, connecting and testing in replacement of industrial earth plug & socket with sheet metal enclosure of IP 44 protection rating, electric driven, single phase including MCB 'C' series SP 20 Amps and supplied with neutral link complete all as specified and as directed.
Supply, fixing, connecting and testing in replacement industrial earth Plug & socket with sheet metal enclosure of IP 44 protection rating, electric driven three phase including MCB 'C' series TP 20 Amps and supplied with neutral link complete all as specified and as directed.
Disconnecting and taking out burnt XLPE Aluminium conductor cable of any description and in any position from walls / steel structure / laid in floors any size any core complete all as specified & directed by Engineer-in-Charge.
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 4 core, 16 sq.mm all as specified and directed .
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 3.5 core, 25 sq.mm all as specified and directed .
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 3.5 core, 35 sq.mm all as specified and directed .
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 3.5 core, 50 sq.mm all as specified and directed .
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 3.5 core, 70 sq.mm all as specified and directed .
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 3.5 core, 95 sq.mm all as specified and directed .
Supply and laying in trenches / laid in floors /ducts / drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of cross sectional area 3.5 core, 120 sq.mm all as specified and directed .
Disconnecting and taking down old distribution Box with MCB/fuse grip TPN/SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position and making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and directed by Engineer in charge.
S&F, connecting & testing of VTPN DB of 12 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed. MAKE :- Legrand Cat.No. 5077 48 or equivalent in Schneider/L&T. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule.
S&F, connecting & testing of VTPN DB of 8 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 5077 47 or equivalent in Schneider- Acti-9/ L&T-Exora. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule.
S&F, connecting & testing of VTPN DB of 4 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 5077 45 or equivalent in Schneider- Acti-9/ L&T-Exora. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule.
Supply only MCCB FP, 16kA, 63 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 5 - 10 x Ir including Supply only of spreader Terminals, discnnecting and dismantling old unserviceable MCCB to the complete satisfaction of Engr-in-Charge. MAKE :- Legrand cat no-4200 13 or equivalent to ABB/L&T/Seimens
Supply only MCCB FP, 25kA, 100 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 5 - 10 x Ir including Supply only of spreader Terminals, discnnecting and dismantling old unserviceable MCCB to the complete satisfaction of Engr-in-Charge. MAKE :- Legrand cat no-4200 57 or equivalent to ABB/L&T/Seimens
Supply only MCCB FP, 25kA, 160 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 5 - 10 x Ir including Supply onlyof spreader Terminals, discnnecting and dismantling old unserviceable MCCB to the complete satisfaction of Engr-in-Charge. MAKE :- Legrand cat no-4200 55 or equivalent to ABB/L&T/Seimens
Supply only MCCB TP, 25kA, 200 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 5 - 10 x Ir including Supply only of spreader Terminals, discnnecting and dismantling old unserviceable MCCB to the complete satisfaction of Engr-in-Charge. MAKE :- Legrand cat no-4202 08 or equivalent to ABB/L&T/Seimens
Supply only MCCB TP, 25kA, 250 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 5 - 10 x Ir including Supply only of spreader Terminals, discnnecting and dismantling old unserviceable MCCB to the complete satisfaction of Engr-in-Charge. MAKE :- Legrand cat no-4202 09 or equivalent to ABB/L&T/Seimens
Supply only MCCB TP, 36kA, 400 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 5 - 10 x Ir including Supply only of spreader Terminals, discnnecting and dismantling old unserviceable MCCB to the complete satisfaction of Engr-in-Charge. MAKE :- Legrand cat no-422007 or equivalent to ABB/L&T/Seimens
Supplying & fixing MCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, complete all as specified and directed. MAKE : - Legrand/ABB/L&T/ Seimens.
Supply, installation, commissioning and testing of indoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar of 2400 Amps capacity, pre-wired and, fabricated in any CPRI Approved panel factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The panel shall be made out of 2.00mm thick CRCA mild steel sheet including suitable stainless steel nuts, bolts & washers for incoming/Outgoing feeder etc duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. The feeder pillar shall be comprising of the followings:- Incommer :- (a) - ACB 4 pole 1600A, 50kA, Manual draw out type - 01 Nos Outgoing :- (a) MCCB 4 pole 400A, 36kA, thermal & magnetic release - 04 Nos (b) MCCB 4 pole 320A, 36kA, thermal & magnetic release - 02 Nos (c) MCCB 4 pole 250A, 25kA, thermal & magnetic release - 04 Nos (d) MCCB 4 pole 200A, 25kA, thermal & magnetic release - 02 Nos (e) MCCB 4 pole 160A, 16kA, thermal & magnetic release - 04 Nos (f) Digital Multifunction meter & indicator set (RYB) - 01 Set
T.H.ASSOCIATES
SHAILENDRA B TULSANI
M/S. Niksun Electro-Infra Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .