| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹18.5 L+₹4,698 (0.26%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹19.9 L+₹1.5 L (7.93%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹19.9 L+₹1.5 L (8.21%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹21.2 L+₹2.7 L (14.9%)Rejected-Finance 01 18 19 ANANDVAN ROW HOUSE LAM ROAD NASHIK ROAD NASH IK ROAD SAUBHAGYA NAGAR NASHIK MAHARASHTRA 422101 | NASHIK | MAHARASHTRA | 422101 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹21.8 L
EMD Value
₹43,600
Closing Date
2 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH)
AS PER TENDER DOCUMENTS
2022_MES_502173_3
86843/E8
Open Tender
Civil Works
Item Rate
180 days
DEOLALI
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE DEOLALI
₹43,600
Yes
6 Jun 2022
5 Apr 2022
4 May 2022
5 Apr 2022
2 May 2022
20 Apr 2022
6 Apr 2022 - 13 Apr 2022
60 days
Amount
Dismantling of PVC water tanks of capacity exc 1000 ltr but n exc 2000 ltr all specified and directed and removing to store.
S&F for rotational moulded polythelene water storage tanks (cylndrical vertical with closed top) 2000 ltr capacity hoisted and fixed in position all specified and directed in SSR Part-I.
S&F in repairs 25mm thick brass ball valves, high pressure, with polythelene float and flynut complete, screwed for iron pope or brass ferrule and fixed all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed.
M&L for brickwork with Fly Ash brick straight or curved on plan exc 6m mean radius and built in CM 1:6 etc complete all as specified and directed old size brick.
Demolition of plain cement concrete(un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded stone aggregate ) as in foundation, filling and mass concrete and finishing exposed surfaces smooth etc complete all as specified and as directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to store.
All as per item No 8 above but 20mm bore
All as per item No 8 above but 25mm bore
S&F 15 mm bore of tube medium grade Galvanised steel water tubing with all fittings and fixed complete to wallsand ceiling or laid in,floors etc complete all as specified and directed.
All as per item No 11 above but 20mm bore
All as per item No 11 above but 25mm bore
Taking down frame with shutters (without taking off shutters from frame) n.exc 1.5 sq.m each all as specified and directed.
Taking down shutters exc 1 sqm and n.exc 2 sqm each all as specified and directed.
S&F for 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete.
M&L for 35mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln easoned and chemically pressure treated all as specified and as directed
S&F 35mm thick 2nd class hardwood factory made glazed and skleton window or door shutters, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a) supplied and fitted to chowkats all as specified and as directed
M&L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S & F cold and hot mild steel butt hinges medium weight 100 mm size etc complete all as specified and directed.
S & F 150 mm size extruded aluminium handles fabricated type, anodised all as specified and directed.
S & F 150 mm size aluminium anodised barrel tower bolts of extruded sections all as specified and directed.
S & F 250mm aluminium alloy, anodised, sliding door bolt with hasp, staple & fixed clips of sheet, cast or extruded section & fixed bolts & sliding bolts of extruded section or cast aluminium alloy all as specified and directed.
S & F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 all as specified and directed.
S & F for Steel windows with side hung shutters including projecting type hinge width steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed.
All as per item No 26 above but without glazing bars.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and avg with aperature 1.40 mm and fixed with stainless steel wire staples etc complete all as specified and directed.
S & F 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) etc complete all as specified and directed removing serviceable tiles to store and rubbish of the poemision.
M&L coloured non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as directed.
M&L coloured glazed ceramic tiles in vertical surface 300x 200x 7 mm thick, joint free glossy finish, set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in CM 1:4 complete all as directed.
S&F 32mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 including all fittings laid in trenches all as directed.
S&F in repairs 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe all as specified and directed flush pipeof pluge the line of lw or high denisity or 32mm dia for low level cistern.
S&F PVC connections 15mm size with PTMT nuts of length 450mm etc complete all as specified and directed.
S&F in repairs 125mm chromium plated shower rose with neck (any pattern) including fixing to steel pipe etc complete all as specified and directed.
S&F 20mm dia brass, chromium plated tubular towel rail, D type, 60cm long between flanges complete.
S&F in repairs vitreous china wash basin of size 550x400mm (flat back including brackets cutting for and pinning in ends of brackets or erecting stand) with padestal stand excluding of fixing of supply and waste pipe , brass chromium plated waste fitting 32mm bore with long screwed shanks and fly nuts, flange end bedded in red lead and other end fixed etc complete all as specified and directed.
S & F in repairs 15mm bore bib taps, cast copper alloy chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule etc complete all as specified and directed.
S & F in repairs 15mm bore pillar taps, fancy type brass chromium plated with capstan heads, screwed down high pressure with long screwed shanks and fly-nuts, screwed for iron pipe etc complete all as specified and directed.
S&F in repairs 15mm bore stop valves, fancy type brass chromium plated, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions etc complete all as specified and directed.
S&F grating doom 100mm dia of PTMT(Minimum weight 25gms) etc complete all as specified and directed.
S & F in repairs vitreous china squatting Pan “Orissa” Pattern, of size 580mm x 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and not exceeding 1.5 m in depth for foundation etc, or for manholes etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft / loose soil etc complete all as specified and as directed.
All as per item No 46 above but hard/dense soil.
Demolition and breaking up drain pipes 150mm dia (Salt glazed ware, AC or reinforced concrete) set in cement mortar compleate all as specified and directed.
Supply & Lay reinforced concrete drain pipes class NP-2, 150mm bore, laid in trenches and jointed complete with collars etc complete all as specified and directed.
M&L for 1:4:8 type D-2 (40mm graded stone aggregate) concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore of pipe etc complete all as specified and as directed.
M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate ) in copings or benching to man holes and finishing of exposed surfaces smooth etc including formwork if any complete all as specified and as directed.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each in soft / loose soil etc complete all as specified and as directed.
Removing of excavated material n exc. 50m and depositing where directed at a level not exceeding 1.5 m above the starting point etc complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for etc complete all specified and directed.
M&L for precast concrete 1:2:4 type B-1 (using 20mm graded stone aggregate)in manholes covers set in CM 1:4 including necessary form work (Note :-Reinforcement will be measured and paid separately) including necessary form work with and including providing missing manhole covers etc complete all as specified and as directed.
M&L TMT steel bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Taking down cement plaster of any description, on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as directed.
M&L for rendering 15 mm thick in CM 1:4 on brick or concrete surface finishing the surface even and smooth without using extra cement etc complete all as specified and as directed.
M & L rendering 10mm thick in Cm 1:6 on wall surface even & fair et with without extra cement.
M/L rendering 5 mm thick in CM 1:3 on concrete surface & finished even & smooth without using extra cement.
M & L for preparation of new plastered surfaces of walls and apply two coats of cement base paint over a coat of white wash complete all specified and directed.
M & L for preparation of new plastered surfaces of ceiling and apply three coats of white wash complete all specified and directed.
Preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete.
M & L for preparation of new wood surfaces of any description exc 10 cm width or girth and applying two coats of synthethic enamel paint over a coat of pink primer all as specified and directed.
M & L for preparation of new plastered surfaces of walls, finished by 3mm thick wall care putty and apply two coats of oil bound distemper complete all specified and directed.
M&L for special treatment to sunken portions of Toilet by demolition of existing treatment of any description and thickness,removal rubbish outside MD land, 10mm thick plaster in cement mortar (1:4) with water proofing liquid conplast 421 of make Fosroc or equivalent as specified and applying one coat of each Nittoproof 100 and Nittoproof 120 of M/S Fosroc or equivalent as specified on plastered surface and rendering again 10mm plaster in cement moratr (1;4) mixed with conplast 421 of M/S Fosroc or equivalent as specified in Sunken portion and CI pipe joints shall be filled/jointed with mixture of cement, fine, sand and Nittoproof 130 of M/S Fosroc or equivalent as specified and provide hole in the wall and fix 600mm long and 20mm dia GI spouts light grade and PCC (1:5:10) type E-2 using 40mm graded stone aggregate filling in sunken portions , floor area of WC& Bath upto 1.50 Sqm complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc.,incl cleaning or refixing or removal to store complete all as specified and directed.
S&F 110 mm bore dia PVC ( SWR grade ) pipes single socketed , in any length with rubber ring joints, fixed to walls etc complete all as specified and directed.
All as per item No 68 above but 75 mm bore.
S & F PVC ( SWR grade ) bends any radius 110 mm fixed etc complete all as specified and directed.
All as per item No 70 above but 75 mm bore.
PVC ( SWR grade) branch piece 110mm, double (double Y) equal or unequal fixed etc complete all as specified and directed.
All as per item No 72 above but 75 mm bore.
S& F in repairs PVC ( SWR ) floor trap plain with grating including jointing with solvent cement of 75 mm dia etc complete all as specified and directed.
S & F in repairs Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe), etc complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of old plastered wall surfaces and applying two coats of cement base paint over a coat of white wash all as specified and directed.
Cutting channels, grooves or rebates n exc 15cm girth, and triming surface on concrete (without reinforcement) or brick walls.
Taking down unserviceable carefully copper/aluminium point wiring (light, fan, socket or power) complete with teak wood battens including fittings such as switches, socket outlets, ceiling roses, pendent brackets, holders etc. but excluding fan regulators, tube light fittings and sketch fittings and making good disturbed surfaces of walls, floor etc.complete all as directed.
Material and labour for point wiring with stranded copper conductor PVC insulated unsheathed 1.5 Sqmm FRLS cable in and including PVC casing caping of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow,Tee,collers bend, PVC conduit for crossing etc. complete with PVC terminals box for mounting switches, sockets, fan regulators etc with one single core continuous 1.5 Sqmm,FRLS copper cable for earth wire complete all as specified and as directed for :-
(a) One Light point controlled by one switch
(b) One fan point controlled by one switch
(c) One 5 pin socket outlet. 5 Amps on the same board.
(d) One 5 pin socket outlet. 5 Amps on the independent. board
Supply and fix switch piano flush type single pole one way 5 Amps complete all as specied .
Supply and fix switch socket combination 5 pin 5 Amps flush type (multi purpose ) complete all as specified and as directed.
Supply and fix ceiling rose of size 65 X 25 mm surface Bakelite three terminals complete all as specified and as directed.
S & F in replacement of lamp angle/batten holder Bakelite with and including 5w LED Bulb complete all as specified and as directed.
S & F in replacement double door sheet metal enclosures factory made DBs 8 way,240 volts,protection class IP-43, SUITABLE FOR FIXING OF MCBs,Isolators etc,confirming as per IEC 61439-3,Suitable for flush Mounting and surface mounting, With Neutral bar,Earthbar and cable ties for cable management,fully shrouded Neutral bars,prefitted masking sheet complete all as specified and as directed.Make:-Legrand,Cat No:5076 11 or equilavent in Siemens/Hanger
S&F MCBs Single Pole of 240 volts 5-32 Amps,10KA Capacity, 'C' Series of Make:-Legrand,Cat No: 4085-87 to 90,92,93,94,95 or eqivalent in Siemens/Hnger
S&F MCBs Single pole + Neutral 240 Volts,32-63 Amps,10KA Capacity 'C' SERIES OF MAKE:Legrand,Cat No : 4086-17 to 20 or equivalent in siemens/Hanger
S&F Decorative ultra slim linear LED lighting with extruded polycarbonate,environment friendly,energy efficient E-LITE LED PRIDE PLUS 18W LED 6000K Make:-Havells Cat Part num:- LHEXBLP7PN1W018 or equivalent C.G,Philips
M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground all as specified and directed (earth pit not less than 2.25m below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connected to GI wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanized iron all as shown in Electrical Plate No. 3 connected to earth test point all as specified or indicated and testing on completion including necessary excavation and earth work in any type of strata, PCC pit and RCC cover, GI protection pipe 15mm bore light grade , watering pipe, wire mesh etc. all as specified and directed by Engineer-in-Charge.
S&F LED Bldg Security light Endura City liner platinum plus uber having long life versalite pressure die-cast aluminium IP66 roadway luminaries with high power 30W LED as light source with acrylic cover Make:-Havells Endura city lite plus 30W LED 757SASYBOPC or equivalent in C.G,Philips,
M & L for bracket made out of GI tubing 40mm dia,light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 50mm wide 5mm thick flat iron with M.S. nuts, bolts 75 mm long 12 mm dia -4 Nos & flat washer (3mm thick) 01 No. for each including preparation of steel surfaces and painting with two coats of aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete all as specified and as directed.
S&F Linear & compact 9W LED 6000k mirror Light with decorative grey end caps,Pokycarbonate body and ripped opal diffuser. Make:-Havells Cat Part No:-LHEXARP7PN1W009 ,C.G,Wipro or equivalent approved by GE.
Taking down old u/s exhaust fan any type and depositing to E/M Store yard and supply and fix new heavy duty exhaust fan, metal body, 300mm sweep,1400 RPM powder coated with all accessories and electric connection all as specified and as directed.Make:-Havells Turbo Force ,Crompton,Bajaj
M/S YOGESH CONSTRUCTION
M/S MK Nair
M/S R.K.S. CONSTRUCTION
M/S MANISH CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .