Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹25.2 L+₹3.2 L (14.6%)Rejected-Finance NO 8 1 KHB MAIN ROAD OPP NATURE VIEW APARTMENT MANORAYAN PALYA RT NAGAR BANGALORE 560 032 | BENGALURU URBAN | KARNATAKA | 560032 | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹25.4 L
EMD Value
₹50,720
Closing Date
15 Aug 2020, 6:00 pmClosed
CWE (ARMY)
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
SPECIAL REPAIR TO BUILDING NO ET28 OF ASC CENTRE AND COLLEGE UNDER GE (CENTRAL) BANGALORE
2020_MES_360181_1
85994/E8
Open Tender
Civil Works
Item Rate
180 days
Bangalore
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (CENTRAL) BANGALORE
₹50,720
Yes
CWE (ARMY) BANGALORE
11 Sept 2020
11 Jul 2020
19 Aug 2020
11 Jul 2020
15 Aug 2020
31 Jul 2020
11 Jul 2020 - 18 Jul 2020
18 Jul 2020
Amount
Dismantling single layer mangalore pattern or similar tiles in roofing complete all as directed.
Dismantling batten for tiles shingles etc of any size including tiling fillets,spaced exc 15cm complete all as directed.
Dismantling boarding any description fixed in any position with nails complete all as directed.
Dismantling timber scantling 40 Sqcm and over section in any position, unframed work complete all as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust complete all as directed.
Dismantling/ wall and ceiling boards (fibre pulp, insulation etc) or insulation boards/ slabs any thickness, including cover fillets complete all as directed.
Dismantling of hessain cloth ceiling with wooden cover fillet complete all as directed
Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15cm thickness (below or above GL) as in plinth protection/path/Hard standing/floor etc. complete removal of debris outside MD land complete all as directed.
Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including Racking out Joints, hacking for Key, scrubbing down with Water, etc. complete removal of debris outside MD land complete all as directed.
Demolition of brick work or PCC solid block or stone/boulder masonry built in cement mortar complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as directed.
Taking down chowkats or frames with shutters (with out taking off shutters from the frames) n. exc 1.50 Sqm each complete all as directed.
Taking down chowkats or frames with shutters (with out taking off shutters from the frames) exc 1.5sqm but n. exc 4 Sqm complete all as directed.
Taking down shutters of any description n.exc 1 Sqm each complete all as directed.
Taking down shutter of any description n.exc 1 Sqm including easing & adjusting shutters and refixing in the same openingcomplete all as directed.
Pre painted galvalume aluminium zinc coating (AZ-150) GI based corrugated steel sheet 0.50mm thick of an colour having tesile strength of 550 Mpa as in roof covering to wall, fixed with self tapping screws complete all as directed. Make shall be JSW colour on plus or equivalent to the makes specified in list of manufacturers.
Pre-painted galvalume aluminium zinc coating (AZ-150) GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, and eves board fixed with self tapping screws complete all as directed. Make shall be JSW colour on plus or equivalent to the makes specified in list of manufacturers.
Second class hardwood boarding 20mm thick supplied and fixed with nails in any situation (except flooring and skirting) planed one side with butt joints complete all as specified directed.
Fixing only second class hardwood boarding 20mm thick, fixed with nails in any situation complete all as specified and directed.
Second class hard wood in Scantling clean sawn and fixed complete all as directed.
2nd class hardwood battens of sectional area exc 5 but n.exc.15Sq cm each spaced at 30cm centre to centre complete all as directed.
4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-primetered self embossed, textured designer board E-Board Classic (White Colour) to be fixed & including Aluminium based powder coated snap grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19xo.9 mm duly suspended with 4mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete as specified and as directed.
Plain Cement concrete 1:4:8, type D2 using 40mm graded stone aggregate for 75mm thick floor as in sub base for tiles all as specified and as directed.
Cement concrete 1:2:4, type B0 (12.50mm graded stone aggregate) for 25mm thick floor as in sub base for floor tiles complete all as specified and as directed.
Nonskid Coloured Ceramic tiles 7 to 8mm thick area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bedding layer of cement mortar in CM 1:6 complete all as specified and directed.
Non skid Coloured Ceramic tiles 7 to 8mm thick area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 sqm in wall/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM 1:4 complete all as directed.
Hardcore with broken stone aggregate of gauge n.exc 63mm deposited spread and levelled in layer not exc 15cm thick , watered and rammed to true surface complete all as specified and directed.
PCC 1:3:6 type C2 75 mm thick (using 40mm graded aggregate) as in Plinth protection finsshed the concrete surface even and smooth without using extra cement complete all as specified and directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and directed.
Rendering 15mm thick on fair faces of brick work or concrete surface in CM 1:6 surface finished even and smooth without using extra cement complete all as specified and directed.
Rendering in 15 mm thick in cement mortar1:4, on fair faces of brick work, finished even and smooth without using extra cement complete all as specified and directed.
Plain, solid, straight 2nd class hard wood frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
30 mm flush door shutters, solid core construction with block board core and plywood face panels, commercial type on both sidescomplete all as specified and directed.
2nd class hard wood glazed and skeleton shutters, 35mm thick, open rebated & prepared to receive wire gauge (with sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitread beads for securing glass etc, sizes of members of shutters as specified in SSR Pt-I, section 8, clause 8.24- (a), supplied and fitted to chowkats complete all as specified and directed.
2nd class hard wood 30 mm thick glazed and skelton shutters for window,divided in squares open rebated & prepared to receive wire gauge (with sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing gauge etc, sizes of members of shutters as specified in SSR Pt-I, section 8, clause 8.24 (b) complete all as directed.
Supply and fixed windows, box type, single shutter for fly proof including pressed steel frames made out of CRCA sheet of 80x60x1.25mm shutter made out of CRCA sheet of 40x20x1.0mm thick for fixing wire mesh, box type hinges iron flat type handles, Telescopic stays etc complete all as specified and directed. Note : (i) Payment under this item will be make combined for steel frames, steel shutters. However unit rate quoted shall deemed to include cost of beading, fittings such as handles, hinges, flat iron to fix mesh on shutters, Telescopic stays, locking arrangements etc. (ii) Supply and fix of steel wire mesh be measured and paid separately under respective item of BOQ. Note : Windows design as per CECZ TD drg No 539.
Hacking out old broken glass (any thicknes, size, quality or desctiption) from metal frame including punching or drillilng out old glazing pins/spring clips complete all as specified and directed.
4mm thick sheet glass ordinary quality and glazing with oil putty in square/rectangular n.exc 0.50 sqm in each panes complete all as specified and directed.
Stainless steel wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.40 mm fixed with wooden beeds complete all as specified and directed.
Butt hinges 100mm mild steel cold rolled, medium weight complete all as directed.
Butt hinges 75mm mild steel cold rolled, medium weight complete all as directed.
125 mm long aluminium anodized handles cast type complete all as directed.
100 mm long aluminium anodized handles cast type complete all as directed.
Supply and fix 100 mm long aluminium anodized handles cast type complete all as directed.
200mm long aluminium, anodized barrel tower bolts of extruded section complete all as directed.
100 mm long Aluminium, anodized barrel tower bolts of extruded section complete all as directed.
Supply and fixed in repair 100 mm long Aluminium, anodized barrel tower bolts of extruded section complete all as directed.
300mm aluminium alloy, anodized, sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as directed.
Supply and fixed in repair 25mm dia aluminium anodised decorative type curtain rods complete all as directed.
Supply and fixed in repair decorative type curtain rod brackets complete all as directed.
Door spring with 300mm mild steel rat rail rod pattern of standard quality including roller and roller plate complete all as directed.
Cutting holes in stone/brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1;2:4 type B1 exceeding half brick but not exceeding one brick all as specified and as directed.
Mild steel work as in band, strap, hold fast, cleat, hook, hinges, base tie for door frame, support or stay for rain water pipe etc and other similar items conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed.
Rolled Mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410 -W (Gde- E- 250) quality-A complete all as directed.
Brick work in CM 1:6 , 23 cm thick and 15cm high along external walls to fill the gap including plastering 15mm thick in CM 1:6 finished even and smooth without using extra cement complete all as directed.
Brickwork with subclass ‘B’ bricks, built in setting in C.M 1:6 complete all as directed.
Precast cement concrete block masonry with solid blocks, type C1 1:3:6 (using 20mm graded crushed hard granite stone aggregate) exc 10cm width & setting in C.M 1:6 complete all as directed.
Preparation of New Wood surface and applying two coats of synthetic enamel paint over a coat of pink primer over 10cm width or girth complete all as directed.
Preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as directed.
Preparing new surface of steel material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primercomplete all as specified and directed.
Complete removal of existing treatment and preparation of surface of wall ,washing,rubbing down and stopping of distempered and painted surface ,applying wallcare putty over a one coat of primer for smooth finished of the surface and applying two coat of oil bound distemper complete all as specified and directed.
Preparing of New surface of wall and applying two coats of distemper oil bound over a coat of Birla Wall care putty 3mm thick over a coat of chalk whiting priming coat complete all as specified and directed.
Preparation of Old decorated surface and applying two coat of white wash on Walls complete and as directed.
Preparation of Newly plastered surface and applying three coats of white wash on Walls complete all as specified and directed.
Preparing surfaces of wooden surfaces new/Old of any description and girth, not otherwise descriped and treated with Creosote oil complete all as specified and directed.
100 mm thick PCC 1:4:8 type D-2 (40mm graded aggregates) as in sub base, Floors, Paving finished even and fair complete all as specified.
15 mm thick screed bed or bedding layer of mortar for laying floor finishes in cement plaster 1: 4 all as specified and as directed.
Chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigments all as specified and as directed.
M & L for Cement concrete 1:2:4, type B1 (using 20mm graded stone aggregates) as in coping & similar bands,plinth courses, string courses, lacing courses, parapets bed plates, drain etc all as specified and directed.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, fans etc and making good distrubed surfaces of wall, floors, etc complete all as directed.
M&L for Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor FRLS 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including PVC rigid non metalic grey conduit conforming to IS-9537 with all accessories fixed on wall, including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with steel screw for mounting switches, sockets, regulator etc including FRLS 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :-
(a) One light point controlled by one switch
(b) One Ceiling fan/Wall fan /exhaust fan point controlled by one switch
(c) One 5 Amps switch socket combination on independent board
(d) One 5 Amps switch socket combination on same board with other switches.
All same as per item No 71 here-in-before but with FRLS 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with FRLS 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly complete all as directed.
S&F Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable FRLS conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing non metallic PVC grey conduit fixed on wall with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of FRLS 6.0 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as directed.
Switch piano, flush button single pole, 5 Amps one way complete all as directed.
S&F Switch socket combination flush type 5 Amp 2 in 1 complete all as directed.
S&F Switch socket combination flush type 5/16 Amps5 in 1complete all as directed.
Ceiling rose surface type bakelite 65x50mm 02 to 03 terminals including supply and fix PVC square blocks complete all as directed.
Taking down Ceiling fan any make,size,sealing cable end,dismantelling blades and removing fan and blades and deposited to store and refixing after completion of work all as specified and directed .
Stepped type electronic fan regulator flush type,up to 300 watts, 50C/S, 230 V. AC complete all as specified and directed.
Supply and fix surface and wall mounted LED battern tube light fitting 20 watts extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver 230 volts all pre wired fixed on walls with all fixing accessories such as 2 Nos of PVC square/ round boxes screws etc and connecting up with three core flexible copper conductor cable of size 24/0 20 sqmm complete all as directed. Make : CG Cat Part No CCS-100-20-65-HL2 DP-NWH, Bajaj Cat Part No BCLSBAL-20W CW or equivalent of Havells/ Phillips.
Supply and fix LED tube light fitting, 1x10 watts slim line linea, 230 volt, with long lasting PVC body with slim & sleek looks all pre-wired fixed on walls with all fixing accessories such as 2 Nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as directed. Make-CG Cat Part No LDL-10 NW, Bajaj Cat Part No BCLSB10 NW or equivalent Havells/ Phillips.
Supply and fixing Energy saving enviomental friendly long life,with high power LED bldg security light 25 watts pressure die-cast Aluminium,heat resistant glass with IP-65 protection,better option for uniform ditribution of light,all accessories including bracket made out of GI pipe 40mm dia medium grade of lenght upto 1.5 mtr,bend to shape and all prewired complete and making necessary connection by using with 3 core flexible copper conductor PVC insulated cable wire 4/0.20 mm size and testing on installation complete all as directed. Make : CG Cat Part No : LSTS-25-CDL-M, Bajaj Cat Part NO : BCLST25W LEDIV2
S&F sheet metal enclosure double door type MCB DB VTPN 4- way, 430 volts AC factory made,IP-43 Protection,Isolated neutral bar suitable for housing MCB TPN and SP along with 200 Amps copper,insulated bus bar assembly, complete concealed in wall,all as specified and directed.
S&F sheet metal enclosure double door type MCB DB SPN 8- way, 240 volts AC factory made,IP-43 Protection,Isolated neutral bar, suitable for housing MCB SPN and SP along with 200 Amps copper bus bar complete conceiled in wall,all as specified and directed.
MCB TPN 63 Amps,10 KA Rupturing capacity,ISI/CE Marked as per IS/IEC 60898,operating voltage 440V AC 3* phase 50c/s complete all as specified and directed.
MCB SPN 32 Amps,10 KA Rupturing capacity,ISI/CE Marked as per IS/IEC 60898,operating voltage 240V AC 50c/s.complete all as specified and directed.
MCB SP 6- 32 Amps,10 KA Rupturing capacity,ISI/CE Marked as per IS/IEC 60898,operating voltage 240V AC 50c/s complete all as specified and directed.
S/Laying cable XLPE insulated screened PVC bedded galvanised strip armoured electric cable heavy duty LT1100 Volts grade with stranded aluminium conductor of 25 sqmm 4-core UG Cable passing through existing pipes/cables tray/roof/floor/ cable trench /on wall and necessary spacers / saddles including provision of neccesary lugs and glands complete & including taking down of old UG cable, all as specified and directed
Excavation in trenches in hard/dense soil, not exc 1.5 mtr wide and n exc 1.5 mtr in depth; for foundation, laying pipes/elect cables etc, and getting out all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as directed.
Removing excavated materials of soil not exc. 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point all as directed
Supply & spreading river sand to required width at bottom and top for cable cushioning (not less 18 cm thick in layer after punning) all as specified in SSR Part-I.
Supply and lay common burnt old size bricks of sub class B laid at right angle on the cable complete in trenches for cable protection complete all as directed by Engr-in-charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe wire mesh and lugs, including testing and dismantling of old earthing complete all as directed.
M&L GI Pipe light grade 40mm dia laid in trenches dust/pole/wall/floor for cable ptotection complete all as directed.
Sangam Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .