Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.4 L+₹68,539 (7.87%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹9.9 L
EMD Value
₹19,784
Closing Date
9 Sept 2021, 5:00 pmClosed
R.Nagender Singh
XEN (E)
Construction of Additional Block of PWD Rest House at Narnaul in Distt. Mohindergarh (Pdg. Fire Alarm system only)
2021_HRY_184920_1
PWD/HRY/RWR/22
Open Tender
Electrical Works
Works
90 days
XEN (E)
Refer DNIT
2 documents required · 2 mandatory
₹1,000
₹19,784
18 Jan 2022
2 Sept 2021
10 Sept 2021
2 Sept 2021
9 Sept 2021
2 Sept 2021
Amount
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7”TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The paneWl shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in -charge of work.Make: Cerberus by siemens/ Edwards EST3/Honeywell Morley Zxe series/Bosch FPA 1000/Simplex 4007 ES
SITC of addressable multisensor detector with a combination of optical and thermal including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. ((Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Make: Siemens Cerberus OH921+ DB-11, Honeywell Morley MI-PTSE+ B501, Edwards SIGA PHD+ SIGA/ Bosch FPA 400 T+FAA-440/Simplex 4007 ES
SITC of addressable Heat Detector with fixed and rate of raise feature including mounting base with LED etc complete as required. Each detector should have 2 as per NFPA 72 style 7 wiring requirement (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to eletrmagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor electromagnetic interfarence and report to the panel-current and average values, EMC safety for detector shall be 50 V/m. shall be EN54/VDS/U: certification. (Detectors without inbuilt isoaltors may be considered with an additional isolator module per detector.Make: Siemens Cerberus HI921+DB-II, Honeywell Morley MI-RHSE+B501, Edwards SIGA DHI+SIGA/ Bosch FPA 400 T+FAA-440/Simplex 4007 ES
SITC of Response Indicator with all labour and material required to complete to the job in all respect up to the entire satisfaction of Engineer – in Charge of work.Makes: Morley, Siemens Cerberus , Edwards/Bosch/Simplex
SITC of intelligent analog addressable type Manual Call point having surface or flush mounting option fully compliant to EN54 having rotary decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect upto the entire satisfaction of Engineer-in-Chage of the work.Make Siemens cerberus/ Morely/ Edwards /Bosch/Simplex
SITC of addressable hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS with power supply and other accessories required complete the job in all respect upto the entire satisfaction of Engineer - in - charge of work.Make: Morley/ Siemens Cerberus/ Edward/Bosch/Simplex
Supply Installation, Testing & Commissioning of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-inCharge of work. Make: Pearl/Giolite/OMEX
Supply & erection of PVC unsheathed s/c stranded ( ISI marked ) copper contuvtor cable 1100v grade in existing pipe excluding cost and erection of pipe but including connection etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer – in charge of work MAKE: FINOLEX/POLYCAB/HAVELL'sPVC unsheathed copper size 1.5 sq mm single core (FRLS)
2 core x1.5sq mm FRLS, armoured, PVC sheathed copper conductor cable
Supply and erection of PVC pipe 25 mm dia ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work Make: BEC, AKG, Kalinga / Diplast
SITC of Addressable Control Relay Module with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall be EN54/UL/VDS CertificationMakes : Siemens Cerberus / Morley / Edwards/ Bosch/Simplex
SITC of Intelligent Analog Addressable Type Monitor Modules having option of RAIL or Surface Mounting with Tri Color LED status indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switch from 01-99 dully approved to GEA GEW1-082 conforming to BS5839 Standards and Duly approved by EN54/LPCB/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.Makes: Siemens cerberus HTRI-M,Morley MI-DMMI, Edwards EST3/ Bosch/Simplex
SITC of Analog Addressable type Active Repeater Fire Alarm Panel with Backlit LCD display, having controlls for reset, mute, accept, silence alarms and self test conforming to BS5839 standards with all labour and materials required to complete the job in all respect up to the entire satisfaction for engineer-in-charge of work.Makes: Cerberus by Siemens ,Morley ZXRA , Edwards 3-LCD ANN/ Bosch/Simplex
Supply, Installation, Testing and Commissioning of minimum 1000 mtr. Range Kheraj make SIREN generator provided at the roof of the building with separate power supply, relay etc.complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.
Supply, Installation, Testing & Commissioning of 6W ceiling speaker 5inch in metal with metal enclosure with Line Matching Transformer and tapping of 3W and 6W. Make: Honeywell / BOSCH / Heinrich
SITC of 2 Core, 1.5sq mm Speaker Cable For LoudspeakersMake Beldon/Polycab/Finolex
Shree Krishna Safety Vision
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .