| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC 5 L LEHAL COLONY PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹29.1 L+₹68,770.68 (2.42%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹29.3 L+₹89,637.08 (3.15%)Rejected-Finance 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹29.9 L+₹1.5 L (5.12%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹30.7 L+₹2.3 L (7.98%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Jaisalmer
GE Army Jaisalmer -345001
REPAIR AND MAINT OF SECURITY PERIMETER AND ROAD NETWORK LIGHTS UNDER THE JURISDICTION OF GE (A) JAISALMER
2022_MES_525659_1
8201/22-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹80,000
Yes
2 Sept 2022
23 May 2022
22 Jun 2022
23 May 2022
20 Jun 2022
6 Jun 2022
60 days
Amount
Note : (a) Contractor has to arrange his own vehicles along with mounted hydraulic ladder/articulated & telescopic boom lift arrangement for attending the complaint throughout jaisalmer cantt area. (b) Contractor shall depute minimum 2 staff daily to attend and rectify the complaint. if not, Contractor shall have to bear a penalty of Rs 50.00 per complaint or maximum of Rs 500 per day on this account. (c) Complaints has to attend and rectify the complaint/defect irrespective of no of trips/Complaints as alloted by Eng-in-Charge.
Supply & fix LED Street light fittings, 25W including making electrical connection to the fitting with Suitable size of service wire including taking down existing unserviceable light fitting of any description all as specified and directed. Make:- Crompton greaves Cat Part No. LSTS-25-CDL or equivalent make specified in list of Makes of particular specifications.
Supply & fix LED Street light fittings, 30W including making electrical connection to the fitting with Suitable size of service wire including taking down existing unserviceable light fitting of any description all as specified and directed. Make:- Crompton greaves Cat Part No. LSTS-30-CDL or equivalent make specified in list of Makes of particular specifications.
Supply & fix LED Street light fittings, 45W including making electrical connection to the fitting with Suitable size of service wire, including taking down existing unserviceable light fitting of any description all as specified and directed. Make:- Crompton greaves Cat Part No.LSTP-45-CDL or equivalent make specified in list of Makes of particular specifications.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/Disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Hard Rock complete all as specified & directed by Engineer-in-Charge. Note :- Hard rock obtained shall be stacked properly at site for measurement and issued under Schedule of credit after deducting 50% for voids. Remaining material considered for removal.
M/L for Tibba sand for cushioning with layers of sand 8 cm before laying of cable & 15 cm after laying of cable (total 23 cm) in trenches, duly punning to a thickness of 18 cm for cable protection complete all as directed and specified. Note:- Thickness after punning shall be measured for payment.
M&L for laying 40 to 50 mm thick roughly hammer dressed jodhpur stone patti cable cover 25 cm to 30 cm wide and not exc 60 cm long each laid dry abuting with each other with maximum gap between adjacent patti/ slabs not exc 10 mm complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Removing excavated materia soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
M&L for plain cement concrete (1:4:8) type D-2 using 40mm grade stone aggregate in foundation of pole/struts etc including necessary form work all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete (1:3:6) type C-2 using 40mm grade stone aggregate in foundation of stay assembly/pole including necessary form work all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete (1:2:4) type B-1 using 20mm grade stone aggregate for couping/encasing around of pole including necessary form work finished and smooth without using extra cement all as specified and directed by Engr-in-Charge.
Supply, transportation fixing and errection of prestressed cement concrete pole in repair 9 metre long, minimum cross section 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class -10 confirming to IS-1678 and including making alternate white and black strips 30 cm height (Total 5 Nos), with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engr-in-Charge. Note :- (i) The rate quoted by the tenderer shall deemed to inclusive of demoliton of existing unserviceable pole. (ii) Pole obtained from demolition will be isuued to contractor under Sch of Credit. (iii) Excavation and earth work and PCC shall be measured and paid separately. (iv) Painting to pole as described in the item shall deemed to inclusive of quoted rate.
Supply and Laying LT underground cable XLPE insulated armoured heavy duty 1100 Volts grade with aluminium conductor multistranded including centre gland lungs jointing materials etc..laid in trench or fixed it to wall includung connecting testing and commissioning, including taking down existing unserviceable cable of any description complete for the following sizes:
(a) 16 Sqmm 4 core
(b) 35 Sqmm 3.5 core
Supply & fix PVC sheathed 1100V grade flat twin core stranded aluminium conductor of size 2.5 sqmm including conduit pipe connecting from SMC box to street light fitting including taking down existing unserviceable service wire of any description complete all as specifed and directed by Engineer-in-charge.
Supply & fix 40 mm bore GI tubing light grade in trenches or on pole for cable protection, including taking down existing pipe complete all as specifed and directed by Engineer-in-charge.
M & L Aluminum lugs eye lid or barrel type complete with cripping/soldering etc including removing the wornout lugs suitable for aluminium cabbles/copper cables of sizes from 16 Sqmm to 95 Sqmm complete all as specifed and directed by Engineer-in-charge.
Supply & fix MCCB 415V, 3 phase 50 HZ FP 63 Amps breaking capacity 10KA (Ics = 100% Icu) including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-charge. Make -C & S Product Code No.CSC2A4* or equivalent make specified in list of Makes of particular specifications.
Supply & fix MCCB 415V, 3 phase 50 HZ FP 100 Amps breaking capacity 10KA (Ics = 100% Icu) including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-charge. Make -C & S Product Code No.CSC2A4* or equivalent make specified in list of Makes of particular specifications.
Supply & Fix MCCB 415V, 3 phase 50 HZ FP 125 Amps breaking capacity 10 KA (Ics = 100% Icu) including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-charge. Make -C & S Product Code No.CSC2A4* or equivalent make specified in list of Makes of particular specifications.
Supply & Fix MCCB 415V, 3 phase 50 HZ FP 160 Amps breaking capacity 25 KA (Ics = 100% Icu) including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-charge. Make -C & S Product Code No.CSE2M250TM4P or equivalent make specified in list of Makes of particular specifications.
Supply & Fix MCCB 415V, 3 phase 50 HZ FP 200 Amps breaking capacity 26 KA (Ics = 100% Icu) including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-charge. Make -C & S Product Code No.CSC4N4* or equivalent make specified in list of Makes of particular specifications.
Supply & fix MCB, single pole, 16-32 Amp, 240 Volts, 'C' Curve 10KA including taking down existing unserviceable MCB of any description complete all as specified and directed by Engineer-in-charge. Make: Legrand (DX3) or equivalent make specified in list of Makes of particular specifications.
Supply & fix MCB, TPN 63 Amp, 240 Volts, 'C' Curve 10KA including taking down existing unserviceable MCB of any description complete all as specified and directed by Engineer-in-charge. Make: Legrand (DX3) or equivalent make specified in list of Makes of particular specifications.
Supply & fix MCB, TPN 100 Amp, 240 Volts, 'C' Curve 10KA including taking down existing unserviceable MCB of any description complete all as specified and directed by Engineer-in-charge. Make: Legrand (DX3) or equivalent make specified in list of Makes of particular specifications.
S&F in repair, galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete for fixing street light fittings complete all as specified and directed by Engineer-in-charge.
Disconnecting and taking out existing SMC of any size and in any position on pole and Supply & fix in repair sheet moulding compound junction (SMC) suitable for terminating 2 Nos 4 x 6/10/16 Sqmm UG cable including S&F of one in Nos MCB SP 6-32A including cable glandes- 2 Nos, and two way connector 1 No, including dismantling old one complete all as specified and directed by Engineer-in-charge.
Material and labour for straight through (Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 150 Sqmm including dismantling the old burnt cable joint termination complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of old painted surface of LT Concrete electric pole of any size by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos), including painting the cross arms/bracing support on poles with a coat of aluminium paint, silver colour aluminium paint with coating of primer and writing of identification Nos with proper stencil cut etc as per directions by Engineer-in-Charge.
Material and labour for preparation of old painted surface of LT Steel tubular pole of any length by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing support on poles and writing of identification Nos with proper stencil cut etc as per directions by Engineer-in-Charge.
Material and labour for preparation of old painted surface of F/P box/LT Panel by removing all dirt, dust, etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour over a coat of primer including writing of identification with proper stencil cut etc as per directions by Engr-in-Charge.
S& Lithium based energy efficient Integrated solar street light of 16 watt in single FRP body with duly polyurenthane coating encases with monocrystalline solar PV panel of 30/35Wp, Lithium battery 11.1/12.8 Volt, 19.8 Ah with inbuit BMS, IP 65, High brightness W-LED (160-180 Im/Watt) lamp with aluminium reflector for better lighting distribution, CRI 70, colour temperature 5700 K-6500 K, Microcontroller based charge controller cum driver, automatic dimming function with PIR motion sensor, Dusk to dawn operation weight not more than 10-12 KG with adjustable MS Clamp suitable for existing pole/wall mounting etc including taking down old unsv Solar Street Light of any capacity complete all as specified and directed by Engineer-in-charge. Note : Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & TOHS complaint.
Supply and fix Din type HRC fuse link of required rating 32A/63A/100A Suitable for HG type 20H/2 complete all as specified and directed by Engineer-in-charge.
S&F Advance Microcontroller and real time clock base astronomical timer panel suitable for 3 phase 415v,AC having 8 bit micro controller with inbuilt battery,16 character two line LCD display, input isolator 125 Amp 4 pole and 3 Phase output with 6 Nos, 32Amps MCB SP and with complete copper conductor power wiring of suitable size, contactor 63 Amps, 4 Pole-03 Nos, inside 2mm (16/18 guage) thick feeder panel duly power coated complete with 40X40X5mm 45CM height angle iron structure with PCC complete suitable for 30 KVA load complete all as specified and directed by Engineer-in-charge.
Supply & fix DX3 Power contactor suitable for power supply 63 Amps 4 NO Contactor including making electrical connection to the contactor complete all as specified & directed by Eng-in-Charge. Make: Cat part No.4125 53 of Legrand or equivalent make specified in list of Makes of particular specifications.
Labour only for attending street light complaints and rectifying the faults viz non ops & flickering of street light, Cable or service wire damage, earth leakage & electric shock in street light poles & panel, hanging or bending of street light etc up to entire satisfaction of Eng-in-Charge including all necessary petty items like lugs, nut, bolts, screws and any type of tool required. Note:-Group of complaints for one feeder will be consider as one job. Complaint slip will printed and supplied by contractor in prescribed format as specified at the time of commencement of contract as directed by Engr-in-Charge.
Note for item No 08 to 10 : Contractor has to arrange telescopic boom lift for maintenance at height of 15m at his own cost. No extra payment will be paid by department
SANJOLI CONSTRUCTION COMPANY
AUTOMATION AND SWITCHGEAR CONTROL
star electricals
M/S SUMAN ENTERPRISES
Leelashah Enterprises
Manisha Enterprises
Shri Maruti Trading Co.
Rasam Engg Co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .