| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC P 27 1 RASHTRAGURU AVENUE DUM DUM KOLKATA 700028 | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹45.5 L+₹5.8 L (14.5%)Rejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | L2 | Rejected-Finance Not L1 in Financial Bid | |
| 3 | L3₹46.5 L+₹6.7 L (16.9%)Rejected-Finance 550 34 P K GUHA ROAD RADHANAGAR DUM DUM KOLKATA 700028 | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L3 | Rejected-Finance Not L1 in Financial Bid | |
| 4 | L4₹49.4 L+₹9.6 L (24.3%)Rejected-Finance | L4 | Rejected-Finance Not L1 in Financial Bid | |
| 5 | L5₹51.3 L+₹11.5 L (29.0%)Rejected-Finance B 814 8TH FLOOR B G TOWER OPP DELHI GATE SHAHIBAUG ROAD AHMEDABAD 380004 | AHMADABAD | GUJARAT | 380004 | L5 | Rejected-Finance Not L1 in Financial Bid |
Tender Value
₹58.1 L
EMD Value
₹1.2 L
Closing Date
22 Feb 2022, 12:00 pmClosed
Sr. Manager (E-E)
O/o The Airport Director, Bagdogra Airport, 734421
Extension of Terminal Building under Phase-III at Bagdogra Airport (SH Electrical and Mechanical Works). SH-II SITC of LT Panels, Supply and laying of cables and IE works.
2022_AAI_103733_1
AAI/BD/CW/2021-22/NIT/04/165
Open Tender
Electrical Works
Item Rate
150 days
Bagdogra Airport
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹1.2 L
11 Jul 2022
1 Feb 2022
23 Feb 2022
2 Feb 2022
22 Feb 2022
2 Feb 2022
2 Feb 2022 - 6 Feb 2022
Amount
SITC of LT Panel conforming to IS 8623 / IEC 60439 PTTA type & shall be of Form-3b construction with following mentioned and complete in all respect and as per technical specifications.
a)Supply, Installation, Testing and Commissioning of cubicle type LT panel, (minimum IP42 protection) for indoor application, suitable for 415V+/-10%, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized modular design from CRCA sheet steel of minimum 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having TPN Aluminium alloy bus bars for high conductivity, DMC/SMC bus bar supports, with short circuit withstand capacity as per design subject to minimum 50 KA for 1 sec , bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common Copper earth bus bar of size as per IS 3043 subject to minimum 50 mm x 6 mm at the rear with 2 Nos. earth stud, solid / flexible connections from main earth bus bar to switchgears with required size of Cooper conductor and control wiring with 2.5 sqmm PVC insulated copper conductor cable (FRLS), cable alleys, cable gland plates in two half, including provision of SPD's. Surge Protection Devices (SPD’S) shall be provided to LT Panel (Type 2 / Class C), i/c providing following switchgears / accessories as per specifications. Bus-Bar: TPN aluminium extensible type main bus bars of minimum 300 Amps. capacity with heat shrinkable coloured sleeves having 100% neutral bus as that of phase i/c DMC / SMC bus bars supports at required intervals complete for cross section, size supports & having spacing etc. for withstanding fault level of 50kA capacity for 1 sec.
b)Incomer: 2(Two) Nos MCCB(Ics=100% Icu), 250 Amps, 4 Pole, min 35 kA with adjustable setting, Microprocessor Based with adjustable Overload, Short Circuit and In-Built Earth Fault Protection, including connections etc as required. 3(Three)Nos. LED type, R,Y,B Phase indicating lamp with 2 Amp MCB for controlling. Intelligent multi function digital meter to read V,A,kVA, KW, kVAR, PF, Hz etc , LED display with required Nos CTs, 250 / 5,15 VA, class 1.0 and control circuit wiring with 2 Amp MCB for controlling.
c)Buscoupler: 1 No MCCB(Ics=100% Icu), 250 Amps, 4 Pole, min 35 kA with adjustable setting, Microprocessor Based with adjustable Overload, Short Circuit and In-Built Earth Fault Protection,including connections etc as required. 3(Three)Nos. LED type, LED type, R,Y,B Phase indicating lamp with 2 Amp MCB for controlling.
d)Outgoing:- i) 02 Nos MCCB(Ics=100% Icu),125 Amps, 4 Pole, min 35 kA with adjustable setting , Thermal Magnetic release shall have Variable Thermal (O/L) & Variable Magnetic (S/C) protection,including connections etc as required. Ii)03 Nos MCCB(Ics=100% Icu), 100 Amps, 4 Pole, min 35 kA with adjustable setting , Thermal Magnetic release shall have fixed Thermal (O/L) & fixed Magnetic (S/C) protection,including connections etc as required. iii)04 Nos MCCB(Ics=100% Icu), 63 Amps, 4 Pole, min 35 kA with adjustable setting , Thermal Magnetic release shall have fixed Thermal (O/L) & fixed Magnetic (S/C) protection,including connections etc as required. iv) 1 Nos MCCB(Ics=100% Icu), 40 Amps, 4 Pole, min 35 kA with adjustable setting , Thermal Magnetic release shall have fixed Thermal (O/L) & fixed Magnetic (S/C) protection,including connections etc as required.
SITC of LT Panel conforming to IS 8623 / IEC 60439 PTTA type & shall be of Form-3b construction with following mentioned and complete in all respect and as per technical specifications.
a)Supply, Installation, Testing and Commissioning of cubicle type LT panel, (minimum IP42 protection) for indoor application, suitable for 415V+/-10%, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized modular design from CRCA sheet steel of minimum 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having TPN Aluminium alloy bus bars for high conductivity, DMC/SMC bus bar supports, with short circuit withstand capacity as per design subject to minimum 50 KA for 1 sec , bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common Copper earth bus bar of size as per IS 3043 subject to minimum 50 mm x 6 mm at the rear with 2 Nos. earth stud, solid / flexible connections from main earth bus bar to switchgears with required size of Cooper conductor and control wiring with 2.5 sqmm PVC insulated copper conductor cable (FRLS), cable alleys, cable gland plates in two half, including provision of SPD's. Surge Protection Devices (SPD’S) shall be provided to LT Panel (Type 2 / Class C), i/c providing following switchgears / accessories as per specifications. Bus-Bar: TPN aluminium extensible type main bus bars of minimum 250 Amps. capacity with heat shrinkable coloured sleeves having 100% neutral bus as that of phase i/c DMC / SMC bus bars supports at required intervals complete for cross section, size supports & having spacing etc. for withstanding fault level of 50kA capacity for 1 sec.
b)Incomer:- 2 Nos MCCB, 200 Amps, 4 Pole, min 35 kA with adjustable setting , Thermal Magnetic release shall have Variable Thermal (O/L) & Variable Magnetic (S/C) protection,including connections etc as required. 3(Three)Nos. LED type, R,Y,B Phase indicating lamp with 2 Amp MCB for controlling. Intelligent multi function digital meter to read V,A,kVA, KW, kVAR, PF, Hz etc , LED display with required Nos CTs, 200 / 5,15 VA, class 1.0 and control circuit wiring with 2 Amp MCB for controlling.
c)Buscoupler:- 1 No MCCB(Ics=100% Icu), 200 Amps, 4 Pole, min 35 kA with adjustable setting , Thermal Magnetic release shall have Variable Thermal (O/L) & Variable Magnetic (S/C) protection,including connections etc as required. 3(Three)Nos. LED type, LED type, R,Y,B Phase indicating lamp with 2 Amp MCB for controlling.
d)Outgoing:- i) 04 Nos MCCB(Ics=100% Icu), 63 Amps, 4 Pole, min 35 kA with adjustable setting ,Thermal Magnetic release shall have fixed Thermal (O/L) & fixed Magnetic (S/C) protection,including connections etc as required. ii) 06 Nos MCCB(Ics=100% Icu), 40 Amps, 4 Pole, min 35 kA with adjustable setting , Thermal Magnetic release shall have fixed Thermal (O/L) & fixed Magnetic (S/C) protection,including connections etc as required.
Supply of following size XLPE insulated and PVC sheathed aluminium conductor armoured Power Cable of 1.1KV grade, confirming to IS 7098, Part-I 1988 with up to date amendments and confirming to technical specifications.(The outer sheath shall be FRLS.)
3.5 CORE 185 sq.mm.
3.5 CORE 50 sq.mm.
4 CORE 25 sq.mm.
Supply of surface/recessed type 2' x 2' (minimum 36W) LED type downlighter suitable to operate on 140-270 V, 50 Hz, AC supply having Extruded aluminium/CRCA/standard alloy housing ,with minimum IP-20 protection,having efficacy of min 100 lm/W, complete with all types of accessories and driver ready to be installed at site as per Technical Specifications attached.
Supply of LED type flood light (minimum 150 watt) luminaire suitable to operate on 140-270 V, 50 Hz, AC supply having Extruded aluminium/CRCA/standard alloy housing ,with minimum IP-65 protection,having efficacy of min 110 lm/W, complete with all types of accessories, mounting device and driver ready to be installed at site as per Technical Specifications attached.
Installation, testing and commissioning of pre-wired, LED downlighter / flood light of all types, complete with all accessories etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Dismanting of existing light fitting of various wattage / ceiling fan and keeping the same in AAI store (within 50 Mtr. distance) as per site condition and as directed by E.I.C.
Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Colour of fans to be approved by EIC).
Supply of ceiling mounted exhaust fan having min sweep dia 130 mm, min air delivery 150 m³/h suitable for single phase AC operation, complete with all acessories as required and ready to be installed at site.
Providing and fixing of suitable size rigid PVC pipe on wall/ above false ceiling with suitable clamping/support for outlet of ceiling mounted exhaust fan as per site conditions and as directed by EIC.(for BOQ Sl No 9)
SITC of single door panel board made out of CRCA sheet steel (conforming to IS 8623,IEC :60439) with provision of FP MCCB as incomer (1 No) & outgoing (4 Nos.) in following configuration including cable alley, basic analog metering module, basic indication module ,busbars etc. with all types of accessories complete in all respect as per technical specifications and ready to be commissioned at site.
(i) Incoming MCCB : FP,100 A, 35 KA Ics= 75% Icu (min) - 01 No. (ii) Outgoing MCBB: FP, 25 A, 25 KA Ics=50% Icu (min) - 03 No. and FP, 63 A, 25 KA Ics=50% Icu (min) - 01 No.
(i) Incoming MCCB : FP,100 A, 35 KA Ics= 75% Icu (min) - 01 No. (ii) Outgoing MCBB: FP, 32 A, 25 KA Ics=50% Icu (min) - 04 No.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 2.5 sq. mm
3 x 4 sq. mm
3 x 6 sq. mm
6 x 6 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing metal box of 200 mm X 150 mm X 75 mm (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet
Bell push
Supplying and fixing 1 or 2 Module (75mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 amps modular socket outlets and 2 nos 5/6 amps modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
4 Pole 32 A Ics=100% Icu at 415V
4 Pole 50 A Ics=100% Icu at 415V
4 Pole , 100 A Ics=100% Icu at 415V
Supplying and fixing 8 way, double door single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 8 way (4 + 24), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’/MCCB ) as required .
4 way (4 + 12), Double door, suitable for MCCB Incoming
8 way (4 + 24), Double door, suitable for MCCB Incoming
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Triple pole
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and installing 450 mm width X 62.5 mm depth X 2.0 mm thickness of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
Supplying and installing 450 mm width X 62.5 mm depth X 2.0 mm thickness of perforated painted with powder coating M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nut painting suspenders etc as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) on cable tray as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 50 sq. mm (35mm)
3½ X 185 sq. mm (57mm)
4 X 25 sq. mm (28mm)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 50 sq. mm
3½ X 185 sq. mm
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground/on surface including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of size 200 mm. dia (wall thickness = 6.3 mm) complete as required.
Industrial Traders
SAHA COMMERCIAL CONSTRUCTION
Mukherjee Commercial Enterprise
jaydeep agency corporation
SUPER BUILDERS
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .