Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC | ₹18.3 L Quoted ₹18.7 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹19.0 L+₹27,875 (1.49%)Rejected-AOC | ₹19.0 L+₹27,875 (1.49%) | L2 | Rejected-AOC M/s Makhija Traders is Lowest Bidder |
| 3 | L3₹21.7 L+₹3.0 L (16.1%)Rejected-AOC 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | ₹21.7 L+₹3.0 L (16.1%) | L3 | Rejected-AOC M/s Makhija Traders is Lowest Bidder |
| 4 | Rejected-Technical 47 VED NAGAR COLONY DEORI ROAD AGRA 282 001 | AGRA | AGRA | UTTAR PRADESH | 282001 | - | - | Rejected-Technical Due to Slow Progress in QE Dec 19 of SWC |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Apr 2020, 6:00 pmClosed
GE Bharatpur
GE Bharatpur
Repair/Maintenance of internal wiring, light fitting, repair/renewal of ceiling fans, exhaust fan, geyser, air washer system and cooling appliances at RMS Dholpur under GE Bharatpur
2020_MES_334782_1
8924/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
RMS Dholpur
Class E category b(I) and c(I)
7 documents required · 7 mandatory
₹500
Yes
GE Bharatpur
₹40,000
Yes
27 Apr 2020
17 Mar 2020
15 Apr 2020
17 Mar 2020
13 Apr 2020
31 Mar 2020
Amount
Disconnecting & taking down the ceiling fan of 1200mm/1400mm sweep, cleaning the dust etc with air pressure, cotton cloth & brush, taking out ball bearing and bush, cleaning with kerosine oil, lubricating greasing, oiling, cleaning to winding including supply and replacement of nuts, bolts, rubber seal, split pin, connector and copper cable PVC size 3 core 0.5 Sqmm upto required lenght from ceiling rose to connector of ceiling fan including hanging, connecting up and testing all as directed. Note : Parts/components replaced other than mentioned above will be measured and paid separately under respective items. (ii) After completion of work all fans/geysers shall be tested in E/M store yard to the entire satisfaction of Engr-in-charge
M&L for painting of ceiling fan/exhaust fan of any sweep complete with blades, down rod etc with synthetic enamel paint of approved colour by spraying including filling cavaties with filler, preparation of surfaces cleaning all dust etc and writing of MES No of size not exc 5cm thick using black enamelled paint all as directed.
M&L for cutting and dismantling the existing winding of ceiling fan of 1200mm sweep and rewinding with super enamelled copper winding wire of suitable gauge including varnishing, lubricating, greasing, oiling and testing complete all as directed by Engr-in-charge.Note: Contractor shall make the suitable arrangement at SDO(MES) premises to do rewinding of fans replacing of accessories, testing upto the satisfactory level in front of concerned E/M in charge without fail.
Description ditto all as per ser item No 03 above but 1400mm sweep ceiling fans
Supply and replacement of following parts/components suitable for ceiling fan 1200/1400mm sweep :- Capacitor 2.5/3.5 mfd, oil filled, 400V AC, 50 HZ, 850C ISI marked Make : Asian/Unistar/Usha.
Ball bearing (6201) Make : SKF, NBC, TATA.
Ball bearing (6202) Make : SKF, NBC, TATA.
Ball bearing (6203) Make : SKF, NBC, TATA.
Ball bearing (6204) Make : SKF, NBC, TATA.
Hanging clamp complete with rubber real Make as existing/sample kept in AGE E/M office.
Supply and replacement of ceiling fan blade suitable for ceiling fan 1200mm sweep (set of three blades).
Supply and replacement of down rod 50cm long 15mm internal dia heavy duty duly painted including hanging clamp, rubber ring, nut and bolts complete suitable for ceiling fan of 1200/1400mm sweep.including necessary hole complete
Supply and replacement of canopy suitable for ceiling fan of 1200/1400mm sweep.
Supply and hanging in replacement of ceiling fan 1200 sweep dia with dimmer type redulator, hanging rod, coupling, pre wired, with copper flexible twin core cable upto ceilingrose, make Havells, model Nicola all as specified and directed.
M&L for cutting and dismantling the existing winding of exhaust fan 380mm sweep with super enamelled copper winding wire of suitable gauge including varnishing, lubricating, greasing oiling testing complete all as directed by Engr-in-charge.
Description ditto all as per ser item No 10 above but for exhaust fan 450mm sweep.
Supply and replacement of following parts/components suitable for exhaust fan 380/450mm sweep :- Capacitor 4 mfd, oil filled, 400V AC, 50 HZ, 850C ISI marked Make : Asian/Unistar/Usha.
GM bush suitable for exhaust fan 380mm sweep.
GM bush suitable for exhaust fan 450mm sweep.
Fan blade set (set of three) for exhaust fan of 380mm sweep.
Fan blade set (set of three) for exhaust fan of 450mm sweep.
Taking down the existing unserviceable water storage type geyser of capacity 25/35 ltr by disconnecting from water connection and reinstallation at the same location after carrying out necessary repair/replacement of unserviceable parts including one coat of spray painting with synthetic enamel paint and testing complete all as directed by Engr-in-charge. Make : Ditz/Recold/Venus/Sidhson/Bathwall/Bajaj.
Description all as per item No 13 above but 50 ltr capacity. Note for item no 13 & 14 : Spare parts required for repair/replacement will be measured and paid under respective items.
S&F in replacement Heating element 2000W with rubber ring clamping screws etc in geyser water storage type of capacity 25 ltr/35 ltr/50 ltr. Make : Bajaj/Venus/Theeta/Micron/Havells.
Supply and replacement following parts required for repair of the geyser water storage type 25/35 ltr capacity. Make : Ditz/Recold/Venus/Sidhson/ Bathwall/Bajaj. Thermostat switch adjustable type.
Reset type thermal cut out.
Fusible plug fuse.
Non return valve vertical type spring loaded, ISI marked.
Water storage tank made out of special laminated texture finished body with covering of non corrosive protection on both sides of sheet with 100% pure Salem stainless steel sheet/electro statically powder coated body made of heavy gauge CRCA sheet.
Iron neck ring.
Brass inlet/outlet assembly complete without element and thermostat.
Aperture plate made of brass.
Element holding clip made of mild steel.
Bolts with washer 25mm long for aperture plate. Make : TVS.
Rubber gasket, plate type for aperture plate.
Rubber gasket, ring type for aperture plate.
Indicator bulb square type complete with necessary connection wire of red & green colour complete as per sample kept in GE's office.
Half door set bottom made of painted steel sheet of heavy gauge including steel screws.
Top cover set made of painted steel sheet of heavy gauge including steel screws.
Pressure release valve of size 15mm, ISI marked.
Anti vaccum valve with GI tee of 15mm bore, ISI marked.
Supply and replacement following parts required for repair of the geyser water storage type 50 ltr capacity. Make : Ditz/Recold/Venus/Sidhson/ Bathwall/Bajaj. Thermostat switch adjustable type.
Reset type thermal cut out.
Fusible plug fuse.
Non return valve vertical type spring loaded, ISI marked.
Water storage tank made out of special laminated texture finished body with covering of non corrosive protection on both sides of sheet with 100% pure Salem stainless steel sheet/electro statically powder coated body made of heavy gauge CRCA sheet.
Iron neck ring.
Brass inlet/outlet assembly complete without element and thermostat.
Aperture plate made of brass.
Element holding clip made of mild steel.
Bolts with washer 25mm long for aperture plate. Make : TVS.
Rubber gasket, plate type for aperture plate.
Rubber gasket, ring type for aperture plate.
Indicator bulb square type complete with necessary connection wire of red & green colour complete as per sample kept in GE's office.
Half door set bottom made of painted steel sheet of heavy gauge including steel screws.
Top cover set made of painted steel sheet of heavy gauge including steel screws.
Pressure release valve of size 15mm, ISI marked.
Anti vaccum valve with GI tee of 15mm bore, ISI marked.
M&L for removing unserviceable grouted "Anchor" type bolts and nuts from the wall and S&F new "Anchor" type bolts (04 Nos of 12mm dia) grouted properly in wall to hold 25/35/50 ltr capacity water storage type geyser with and including nuts and washers and marking good the disturbed surface in cement mortar 1:3 complete all as directed by Engr-in-charge.
S&Fin repair PVC connection 15mm dia, 60cm long with PTMT coupling complete, Make : Pryag/Poly tuf.
S&F in repairs stop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions of 15mm bore, ISI marked.
M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing etc and making good, cutting exc 10cm and not exc 20cm girth in brick or stone wall.
Taking up or down the existing unserviceable GI steel tubing with connection and S&F new PPR-R pipe random polimerised pipe of 15 mm internal dia and 20 mm external dia with all fittings, male and female brass threaded, coupler, elbow, reducer, tee etc complete to walls and ceilings or laid inside floors as conceled complete all as specified and as directed by Engineer in Charge Make : SFMC/Supreme.
Ditto all as per Stl Item No 22 here in before but 20 mm dia internal dia and 25 mm external dia
S&F in repair PVC cable 3 core copper conductor of size 2.5 Sqmm to water storage type geyser of capacity 25/35/50 ltr including taking out old cable. Make : Plaza/Gloster/ Finolex/NICCO.
Taking down U/S plug top and S&F new 3 pin plug top 16 amps, 230 volts, ISI marked. Make : Anchor/Kinjal/cona/ Recold/Leader.
Taking down carefully existing unserviceable batten/surface conduit/ concealed conduit aluminium point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc including sunken boxes and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and as directed by the Engineer-in-Charge.
Taking down of unserviceable DBs/ switch fuses/ changeover in sheet steel enclosure complete with MCBs/Fuses/grips any capacity after disconnecting all cables etc and removing from site and making good disturbed surface of wall, floor etc. complete all as specified and as directed by Engineer-in-Charge.
Dismantling of old U/s sub main wiring and service wire of any size and make complete all as specified and as directed by Engineer-in-Charge.
Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated FRLS and unsheathed of size 1.5 Sq mm stranded core in and including PVC casing capping (ISI Marked) with all fittings such as tees, bends etc terminating in and including MS sunken box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’ for one fan or light or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.50 Sqmm PVC insulated unsheathed copper conductor cable, stranded single core as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge Make of cable Nicco/Paragon/L&T /Havell's/KEI/RR Cable, Make of casing caping Finolex/ Modi/ Supreme/Polycab/CG/Precision (ISI Marked).
All as per item No 29 here-in-before but socket point on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 29 here-in-before but socket point on the independent board complete all as specified and as directed by the Engineer-in-Charge.
Ditto- all as per srl item No 29 here-in-before but with multi stranded copper conductor cable, 1100 volts grade (ISI marked), PVC insulated and unsheathed of size 2.5 Sqmm single core and with and including 2.5 Sqmm PVC insulated unsheathed single core copper standed conductor cable as earth continuity conductor to common earth and earth dolly for one 16 Amp socket outlet point on the independent board complete all as specified and as directed by Engineer-in-Charge.
S&F socket outlet 2 in 1, 5pin, 6 Amps multi purpose flush type 230 volt Make : Anchor code No 95015 penta or equivelent in Legrand
S&F switch socket combination 2 in 1, 16 Amp flush type multi purpose 230 volt make : Anchor code No 4282 penta or equivelent in Legrand.
S&F switch piano flush button single pole one way 6 Amps 230 volt grade Make : Anchor Code No 95111 Penta or equivelent in Legrand
S&F bell push flush type 5 Amps 230 volts grade code No 95113, Make : Anchor Penta or equivelent in Legrand.
S&F ceiling rose surface bakelite 50 x 40 mm three terminal ISI marked including suitable size of PVC board make : Anchor code No 3290 penta or equivelent in Legrand.
S&F in replacement of ceiling fan regulator step type, 230 Volt, 150 Watt with 5 step of control including making holes in laminated bakelite sheet cover and connection complete all as specified and as directed by Engineer-in-Charge..Make - Havells/ Leader /SSK /MDS/ Legrand/ Philips/Anchor
M&L call bell multi musical type 230 volts grade code No 38830 make : Anchor/Panasonic or equivelent in Legrand.
Sub main wiring in PVC casing and capping with 2 single core 04 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 04 sqmm copper conductor cable connected to common earth and earth dolly complete and including PVC Cassing and Capping complete all as specified and as directed by Engineer-in-Charge.(Note two run of 04 sqmm and one run of 04 sqmm will (as earth wire) be measured as 1 RM. Make of cables: Nicco, L&T, Paragon, havells)
S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,SPN 8 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make -L&T ( Exora series)/Schneider/Cat Part No 607711in legrand /NBKRENSNDD08 in Schnedier or equivalent in Make Siemens Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate
Ditto item 41 but for 4 way SPN Cat Part No 607710 in Legrand/ NBKRENSNDD04 in Schnedier/8GB0204RC or equivalent in Make L&T (Exora series )/Seimens complete all as specified and as directed by Engr-in-Charge
S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,TPN 4 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make - Legrand Cat No 607835/A9HTDN04E in Schneider or NBKRENTHDD04 or equivalent in Make L&T Exora series/ Siemens Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate
Supply and Fixing MCB single pole, 240 volts of rating 6-32 Amps of C curve breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge Make :- Legrand cat Part No 408587 to 408595, cat No A9N61515 (6 to 32Amps C curve) in make Schnedier or equivalent in make Siemens, L&T Exora series
Supply and Fixing MCB suitable for 6 to 40 Amps, 240 Volt AC supply C Curve single pole and neutral (SPN) with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand cat Part No 408609 to 408617, cat No A9C62263 (6 to 32Amps C curve) in make Schnedier, Siemens, L&T Exora series
Supply and Fixing only MCB 63 Amps, 440 Volt AC supply Triple pole with neutral (TPN) C curve with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand cat Part No 408794, cat No A9N4P63 (6 to 32Amps C curve) in make Schnedier, Siemens, L&T Exora series
M&L Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed FRLS of size 1.5 Sq mm stranded core drawn in and including non metalic ridge concealed conduit with all fittings such as tees, bends etc terminating in and including New MS sunken box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’ for one fan or light or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.50 Sqmm PVC insulated unsheathed copper conductor FRLS cable, solid multistanded as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 47 here-in-before but socket point on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 47 here-in-before but socket point on the independent board complete all as specified and as directed by the Engineer-in-Charge.
Ditto- all as per srl item No 47 here-in-before but with multi stranded copper conductor cable, 1100 volts grade (ISI marked), PVC insulated and unsheathed of size 2.5 Sqmm single core and with and including 2.5 Sqmm PVC insulated unsheathed single core copper standed conductor cable as earth continuity conductor to common earth and earth dolly for one 16 Amp socket outlet point on the independent board complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch 1 way 6 Amps 1module 230 volt grade Make : Anchor Code No 95111 Penta or equivelent in Legrand complete all as specified and as directed by Engr-in-Charge.
S&F modular switch 1 way 16 Amps 1module 230 volt grade Make : Anchor Code No 95112 Penta or equivelent in Legrand complete all as specified and as directed by Engr-in-Charge.
S&F modular socket on existing plate, 6Amp, 2/3 pin combined, 2 module as per existing type and model complete all as specified and as directed by Engineer-in-Charge. Make-Legrand/Crabtree or equivalent.
S&F modular socket on existing plate, 6Amp/16Amp combination, 2/3 pin combined, 2 module as per existing type and model. Make-Legrand/Crabtree or equivalent.
S&F modular white cover plate with frame of 6 module as per existing model and type complete all as specified and as directed by Engineer-in-Charge. Make - Legrand/Crab Tree or equivalent
S&F modular white cover plate with frame of 8 module as per existing model and type complete all as specified and as directed by Engineer-in-Charge.Make - Legrand/Crab Tree or equivalent
S&F modular flush metal box 12 module complete all as specified and as directed by Engineer-in-Charge.
S&F modular fan regulator 2 module SP, 240Volt
S&F modular flush metal box 6 module complete
S&F modular flush metal box 8 module complete
S&F modular flush metal box 12 module complete
S & F Photon Ultra LED glass crystal tube rod 20 Watt suitable for easy replacement and refixing of old frames 1200mm long with G-13 lamp holder T5 and T8 , housing finished in white powder coating complete with all accessariesall as specified and as directed by Engineer-in-Charge.Make - Surya/Phillips or Havells Cat part No-CRYSTAL1213T8DSTL20WLED865SGLASS.
S&F LED tube frame slim type, prewired with complete accessories suitable for fixing on wall/ceiling complete all as specified and as directed by Engineer-in-Charge. Make - Havells Cat Part No REGALBATTENT8UPTO1X22WSSBSWH or equivalent in Phillips/Bajaj/CG
S&F LED bulb 14W cool day light , in-built voltage surge protection > 3.5kV, single ph, 230V, luminous efficacy 100Lm/Watt, base B22, min 3 star rated all as specified and as directed by Engineer-in-Charge. Make - CG or equivalent in Phillips/Havells.
S&F recess mount light fittings of SMD LED high bright lights of size 595mm x 595mm x 70mm (2ft x 2ft) square fixure with opel diffuser, slim, compact, aluminium die cast material with LED driver with complete acceesories suitable to fit in false ceiling board accurateley all as specified ans as directed by Engineer-in-Charge. make: Havells, cat Part No PLUTONEO2x2PLR28WLED840S or equivalent in CG/Bajaj/Phillips.
Labour for checking/repairing the terminals for preventive maintenance of switch boards , sockets, switches, terminal blocks, ceiling rose, light point junction boxes etc, any type and capacity and tightening the screws , binding insulation over the naked wire, dressing neatly the casing capping/PVC conduit pipes, repairing service wires, repairing DBs etc and arranging inside the board to prevent short circuit etc, attending repair/replacement of no light complaints because of burnt out MCBs, Loose terminal of MCBs, tripping due to overload, repair/replacement of service wire and PVC service cables on air/under ground all as specified and directed by Engineer-in-Charge. Note: Contractor shall provide 01xskilled electrician and 01 x helper daily to SDO(MES) Dholpur E/M complaint cell for attending breakdown. 05 x nature of complaints at any location of RMS Dholpur at any distance (56.a to 56.g below) shall be counted as one job. 01 x Electrician and 01 x helper shall be provided by the contractor till the completion of contract and upto the completion of each job as mentioned above. One Job comprises any three of the following (a) to (h) or combination of any as per site requirement: (a) 5/15Amp switches repair/replacement (b) SP/SPN/TPN MCBs (c) Casing capping/conduit pipes (d) service wire above/below GL any size and type (e) Submain wiring any size (f) All type of Tube light fittings/lamp holder/sketch light/garden light repair (g) 5/15Amp socket repairing/replacement on same board or independent board
S&F in replacement of compressor of 1.5TR window AC with mounting accessories, gas filling and testing complete all as specified and as directed by Engineer-in-Charge
S&F in replacement of compressor of 2TR window AC with mounting accessories, gas filling and testing complete all as specified and as directed by Engineer-in-Charge
S&F in replacement of compressor of 1.5TR split AC with mounting accessories, gas filling and testing complete all as specified and as directed by Engineer-in-Charge
S&F in replacement of compressor of 2TR split AC with mounting accessories, gas filling and testing complete all as specified and as directed by Engineer-in-Charge
M&L for dismantling the joints of each compartment of duct and cleaning of duct from air washer outlet to cadet's room opening of any length by using anti scaling spray, scrapping the foreign materials deposited on internal wall of the duct, opening the outlet grills, blowing air with high pressure through duct to get the deposited foreign materials by using external heavy duty compressor, applying oil spray inside the duct to prevent the sheet from corrosion with very thin layer, connecting all the compartments as per existing position, replacing gasket at all joints, all as specified ans as directed by Engineer-in-Charge.
M&L for replacing insulating layer over the duct to prevent from heat or any extreme weather by using synthetic foam or synthetic rubber and wrapping with garnison net or square threaded net around the insulation by using suitable solvent or compound to stick permanenty after dismantling the old UNSV insulation layer and scrapping the surface and cleaning properly before applying the new insulation layer all as specified and as directed by Engineer-in-Charge
M&L for checking all the water pipeline connections, repairing leakages from PVC storage tank to air washer system storage tank, welding the cracks or hole or fabricating with new sheet for 40mm GI drain out pipes, replacing end plug of drain system and over f;low system of bottom mount tank, checking the condition of float valves, cleaning the valve and refitting, leakage testing and rectifying in all respect in pipeline and existing tank and making fucntional at all cost all as specified and as directed by Engineer-in-Charge
M & L 15 mm thick rendering in CM 1:4 on brick work or concrete surfaces finished even & smooth w/o using cement, with using WPC @ 3.% by weight of cement all as specified and directed by Engineer-in-Charge.
M&L for rendering 10 mm thick on fair faces concrete/brick.stone surfaces of wall in cement mortar 1:4, finished even and smooth without using extra cement for better finish as per existing shape all as specified and directed by Engineer-in-Charge.
M&L batten holder insulated with back plate including suitable size of PVC round block all as specified and directed by Engineer-in-Charge. make Anchor or equivalent in Havells/Kinjal
S&F in repair LED light fitting 1 x 9 W 230 volts bulk head luminaries with Lamp holder etc complete with all accessories duly prewied and including connecting up with twin core twisted flexible copper conductor cable of suitable size 230 volts 50 HZ all as directed by Engineer-in- Charge. Make -Havells/Bajaj/CG.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing the same upto 30 cm above normal ground level with plug at top including pipe fittings etc complete and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m and 50 mm thick RCC (1:2:4 type B-0) pit cover reinforced with 8 mm dia @ 150 mm c/c both side in lieu of CI Cover all as specified as shown in electrical plate No 3 SSR Part-I.
S&F sheet metal enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 volts. Make- L&T, Havells, Legrand/HPL complete all as per specified by Engr-in-charge.
Taking out and servicing of window type air conditioner cap-1.5TR/2.0TR including cleaning/removing all dust/mud, oil and other foreign particle from grill, filter, condenser fin, avaporator fin including opening cover, peripheries and whole body using detergent solution or chemical solution and refitting the same complete all as specified and directed by Engr in Charge.
Supply and replacement of following spare parts/accessories of window type Air conditioner of capacity 1.5TR/2TR:- (a) Starting Capacitor 80-100/ 100-120 MFD, make : TESLA or Equivalent make approved by GE.
Rurning capacitor 36MFD/45MFD, make : TESLA or Equivalent make approved by GE.
Fan blade of blower as per sample or directed
Screen Filter of air conditioner of capacity 1.5/2.0 TR as per existing or directed.
Replacement of front PVC grill as per existing size/model for window type air conditioner including taking out unserviceable stariner with capillary tube from the AC complete all as specified and as directed. Make: RANUTROL or Equivalent make approved GE.
Strainer alongwith capillary tube suitable for 1.5Ton capacity window type air conditioner including taking out UNSV strainer with capillary tube from theAC complete all as specified and as directed. Make : RANUTROL or Equivalent make approved by GE.
Starting relay suitable for window and split type AC. Make: SRIRAM or Equivalent make approved by GE.
Supply and fixing thermostatic switch suitable for window type AC 1.5/2.0 Ton capacity including taking out unserviceable thermostatic switch from the AC complete all as specified and directed. Make : INDFOSS or Equivalent make approved by GE.
M&L for flushing, pressurising of AC of all type of capacity 1.5/2.0TR including brackets, pipe line and fixing insulating pipe lines including gas charging for top up using refrigerent R-22/R-134a (suitable as per requirement) after rectifying leakage in the system vacuumizing and dehydration as per standard practice, brazing of copper tubes, testing/commissioning complete, including the shifting of service connection and voltage stabilizer to the new location all as directed by Engr in Charge. Note: The rates shall also include transportation, civil work and making good to the disturbed surfaces.
Supply and fixing fan motor with fan blade unit suitable for 1.5Ton capacity window type air conditioner of various model including dismantling the exisitng unserviceable burnt/broken fan motor with blade complete all as specified and as directed. Note: The quoted rate shall be deemed to include for the cost of rubber rings, small screws, nuts, bolts and other minor items.
Supply and fixing fan motor with fan blade unit suitable for 2Ton capacity split type air conditioner of various model including dismantling the exisitng unserviceable burnt/broken fan motor with blade complete all as specified and as directed. Note: The quoted rate shall be deemed to include for the cost of rubber rings, small screws, nuts, bolts and other minor items.
Repair to electronic panel board / PCB of Airconditioning capacity 1.5TR/2TR complete all as specified and as directed.
Supply and fixing in repair PVC Flexible drain pipe, 15mm dia and 2mm thick of wall of wall of split type AC complete all as specified and directed .
Taking out and servicing of split type air conditioner cap 1.5/2.0 ton including cleaning/removing all dust/mud, oil and other foreign particle from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete all as specified and as directed.
M&L for flushing , pressurising the system, leakage testing, vacuumization and charging with refrigerant R-22/R-143a (suitable as per requirement) after rectifying leakage in the system vacuumising and dehydration as per standard practie including testing in all respect for 1.5 Ton split type air conditioner complete all as specified and as directed.
M&L for flushing, pressurising the system, leakage testing, vacuumizaiton and charging with refrigerent R-22/R-134a (suitable as per requirement) after rectifying leakage in the system vacuumizing and dehydration as per standard practice including testing in all respect for 2.0 TR split type air conditioner complete all as specified and as directed.
S&F remote control operating device for Window/Split type AC of 1.5/2.0 ton with 02 Nos of pencil battery all as specified and directed.
S&F Ken Form for split type AC upto 2.0 TR for insulation of copper pipes complete all as specified and directed.
S&F in repair display for split ype AC upto 2.0 TR complete all as specified and directed.
Taking down u/s water cooler of any cap./make from site in existing location / position for carrying out repairs complete and reinstallation at site complete all as specified and directed by Engr in charge.
S&F condenser fan motor with fan blade for water cooler, Cap - 150/150 Ltrs including dismantling the existing unserviceable burnt/broken fan motor with blade by cutting worn out copper winding and replacement of bearings and bushes, shaft and testing complete all as specified and directed. Note: The quoted rate shall deemed to include for the cost of rubber rings, small screws, nuts, bolts and capacitor.
All as per serial item No-97 above but of Water cooler capacity 80/40 Ltr.
M & L for flushing, pressurising the system , leakage testing vacuumization and charging with refrigerant R-134a at apprporiate pressure after rectifying leakage in the system vaccumising and dehydration including testing as per standard practice at site for water cooler of cap 150/150 ltrs of Make : Bluestar/Usha/Voltas complete all as specified and directed by Engr in charge.
All as per serial item No-99 above but of Water cooler capacity 80/40 Ltrs.
Supply and replacement of following spare parts/accessories of water cooler of capacity 150/150 Ltr - (a) Capacitor 35 MFD, ISI marked
Thermostat with knob as per existing size and make.
Relay with overload protection assembly
Supply and replacement of following spare parts/accessories of water cooler of capacity 80/40 Ltr- (a) Capacitor 25 MFD, ISI marked
Fan blade of condenser fan motor for water cooler cap 80/40 Ltr as per existing size
Supply and replace chromium plated push cock size 15mm suitable or as per existing for water cooler of any capacity, type and make complete all as specified and directed by Engr in Charge.
Supply and replace PVC flexible pipe size 40mm dia with necessary clamping with jubli clips for drain water tray as per exisiting suitable for water cooler complete all as specified and directed.
M&L for painting of water coolers of capacity 150/150 Ltrs by cleaning old deteriorated exterior surface and necessary preparation of surface by scrapping rust, grease, dirt etc for applying approved colour by using spray painting technique to match with existing colour at existing location complete all as specified and directed by Engr-in Charge
All as per ser item No - 105 abovebut water cooler of capacity 80/40Ltrs
Taking u/s refrigerators of any cap./make from site in existing location / position for carrying out repairs and reinstallation at site, including testing complete all as specified and directed by Engr in charge.
M & L for flushing, pressurising the system , leakage testing vacuumization and charging with refrigerant R-22/R-134a at apprporiate pressure after rectifying leakage in the system vaccumising and dehydration including testing as per standard practice at site for water cooler of cap 170/190 ltrs of Make : Samsung/LG/Godrej complete all as specified and directed by Engr in charge.
All as per Serial Item No-107 here-in-before but of capacity 265/280Ltrs Make-Samsung/LG/Godrej
All as per Serial Item No-107 here-in-before but of capacity 300/310Ltrs Make-Samsung/LG/Godrej
Supply and replacement of following spare parts / Accessories of refrigerator of any capacity 170/ 190Ltrs : - (a) Bulb inside the refrigerator suitable for existing refrigerator
Magnetic rubber door gasket suitable for existing refrigerator
Push type door switch suitable for existing refrigerator
Starting relay suitable for existing refrigerator. Make: SRIRAM or equivalent make approved by GE
Replacement of compressor of capacity ranging from 165 Ltr to 190Ltr , copper wound, reciprocating type, testing complete all as specified and as directed.
Supply and replacement of following spare parts / Accessories of refrigerator of any capacity 265/280 and 300/310Ltrs : - (a) Starting relay suitable for existing refrigerator. Make: SRIRAM or equivalent make approved by GE
Thermostatic switch auto defrost type with knob suitable for existing refrigerator
Bulb inside the refrigerator suitable for existing refrigerator
Magnetic rubber door gasket suitable for existing refrigerator
Push type door switch suitable for existing refrigerator
Door lock with two keys suitable for existing refrigerator
Replacement of compressor of capacity ranging from 165 Ltr to 190Ltr , copper wound, reciprocating type, testing complete all as specified and as directed.
Taking down desert cooler of any size and make from bracket/stand from any location, spanning all three side shutters and taking out old wooden chips, pad, cleaning outer and inner surfaces by rubbing with sand paper or wire brush or blade, repainting with spray paint (using spray gun) one coat of red oxide primer and two coats of anti corrosive synthetic enamled paint, Asian Paints Ltd (Color as ordered) outside complete and inside including water tank and re-fixing properly at the place where directed by Engr in charge.
Opening of desert cooler of any capacity for replacement of following U/S accessories and Connecting and testing of following:- (a) Fan Motor copper wound 20" sweep, 3 Speed single phase 230V AC supply complete with Blade (Make: Khaitan/ CG /Bajaj/Cool Home)
MS Bracket with mounting ring of cooler fan motor and mounting clamps/legs of existing size/model
PVC submersible Pump complete single phase 230V AC supply for desert cooler, 1 meter head or suitable to existing desert cooler. Make: Khaitan/Crompton Greaves/Bajaj/Summercool
Cutting burnt winding of fan motor and rewinding with super enamelled copper winding wire and replacing gun metal bush shaft.
Oiling and greasing of Fan motor
Replacement of PVC front grill any size and capacity
Replacement of Desert cooler side panel shutter made out of 20 SWG GI Sheet as per existing position complete with nuts bolts and washers etc all as directed.
Replacement of desert cooler body bottom tank
Top of the desert cooler made of 20 guage GI Sheet riveted/bolted to matching the existing top complete.
PVC water distribution cup with PVC elbow and pipe for any size of cooler
Replacement of capacitor cap- 4 MFD, suitable for desert cooler as per existing size. Make: L&T/Epco/Khaitan or equivalent
Internal wiring with PVC insulated copper conductor wire of 1.5sqmm complete using copper thimbles ISI marked
Wooden Chips pad of set of three (Not less than 400gm) of any size superior quality with chicken wire mesh.
Replacement of PVC insulated and sheathed flexible 1100 volts grade 3 core multistranded copper conductor of size 1.5 sqmm. Not less than 3 meter length MAKE : PLAZA/ FINOLEX / POLYCAB/ANCHOR complete all as specified and directed by Engr in charge.
Replacement of 3 pin plug top 5 Amp. Make : ANCHOR complete all as specified and directed by Engr in charge.
Taking out old rusted and S&F GI pipe, 15 mm bore, medium grade, ISI marked with fittings laid in trenches or fixed to walls, ducts, floors etc including necessary excavation and earth work complete for desert cooler/water cooler connections all as specified and directed by Engr in charge. (Make: Surya/ Prakash /Tata/Jindal)
All as per Item No 119 above but of 20mm bore
S&F sheet metal enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 volts. Make- L&T, Havells, Legrand complete all as per specified by Engr-in-charge.
Taking down u/s air washer, cleaning and removing dust particles inside the chamber of air washer container, disconnecting all electrical wires with proper termination and insulating the naked wire sif any, removing unsv FASD starters etc and refitting the all removed and items after repairing/replacing at site as per the existing position all as specified and directed by Engr-in-Charge
S&F in repairing the following accessories of Air Washer:- (a) DOL Starter of capacity 5HP suitable for three phase 3HP motors complete with on off push buttons and over current relay. Make-Legrand/L&T.
Rewinding 5HP motor of lifting pumpset incl dismantling/ assembling and transporting etc.
S&F bearing of motor suitable for 5HP Make CG, in repairing incl taking out old UNSV , applying suitable grease and test run etc all as specified and directed.
Sheet metal door locks with metallic handle and key with complete accessories including takind town old UNSV lock and key all as specified and directed.
Supply and fix motor fan belt of suitable size genuine part from the make of EdgeTech Air systems all as specified and directed.
Supply and fix in repairing compartment door of Mild Steel, with locking arrangements, hand lock and key, painting of metal primer and two coat super enamel paint with existing colour and finish includng removing of UNSV door etc all as specified and directed.
M&L for rewinding and repair of burnt out 0.5HP pump from the mounting of lower tank incl transporting to workshop, transporting back to its original location and mounting, refitting, testing etc complete all as spefified and directed by Engr-in-Charge.
S&F copper threaded float valve of size 25mm including rod and ball in replacement of old UNSV one and testing all as specified and as directed by Engineer-in-Charge
S&F CPVC pipe in replace ment of UNSV and broken of size 25mm with suitable compound for jointing over the pump outlet including all kind of accessorie all as specified and as directed by Engineer-in-Charge
S&F of CPVC valve 25mm size along with CPVC union in replacement of old UNSV one all as specified and as directed by Engineer-in-Charge
S&F in replacement of air filtration pad, corrugated, thin sponge layer consisting, of paper membrane as one layer, net cloth as second layer and foam as third layer suitable to filter the inlet air entering into the air washer system while running the plant of dimension not less than 1.5m x 1.5m or as per existing size suitable for vcentral air washer system including fixing pad, nuts bolts and accessories etc all as specified and as directed by Engineer-in-Charge.
M/S S.S Traders
M/S SHARADA ASOCIATE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .