Loading…
Loading…
Tender Value
₹39.1 L
EMD Value
₹78,200
Closing Date
10 Aug 2026, 5:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER ELG
14 conditions · 5 needing a document upload
The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
Scanned copy of valid GST (Goods & Service Tax)Registration Certificate.
The following documents should be attached with the tender ( Annexure-V (A) certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. & Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder
Partnership deeds, power of Attorney etc. (if any) : The tender shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of partnership concern he should submit the certified copy of the partnership deed along with the tender authorisation to sign the documents on behalf of the partnership firm. If these documents are not enclosed along with the tender document, the tender will be treated as hearing lease submitted by the individual signing the tender documents. The Railway will not consider any power of Attorney granted by the tender or any changes in the composition of the firm made subsequent to the execution of the contract. It may however recognize such power of Attorney and change after obtaining proper legal advice, the cost of which will be chargeable to the contract.(Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder. As per clause no. 14(e) of GCC'22, the following documents to be uploaded in terms of Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
Option for receiving payment through Letter of Credit . (Please attach scannedcopy of ANNEXURE 1 LC & ANNEXURE 2 LC duly filled up by the firm if optedfor)
The following documents should be attached with the tender: (i)Scanned copy of Pan Card. (ii)Scanned Copy of EFTMANDATE FORM Duly filled up by the bidder(iii)Tender Document (duly digitally signed by the bidder)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Scanned copy of valid Trade license or Propitorship Certificate.
List of the Works completed in the last three financial years giving description of work. Organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and date of payment and final value of contract should also be given. (Supportive documents/ certificates from the organization with whom worked/are working should be enclosed) (Please attach scanned copy of Annexure-I duly filled up).
List of works in hand indicating Supportive documents/certificates from the organization with whom worked/are working should be enclosed) description of work, contract value, approximate value of balance work yet to be done and date of award. (Supportive documents/certificates form the organization with whom worked/are working should be enclosed).(Please attach scanned copy of Annexure-IV duly filled up)
Railway Officers Associated with tenderer:RAILWAY OFFICERS ASSOCIATED WITH TENDERER 1. ExRailway Officer as tenderer: Should tenderer be a retired Gazetted Officer working before his retirement on any of the Railways owned and administered by the President of India, or should the tenderer being partnership firm have as one of its partners a retired Gazetted Officer as aforesaid, or should the tenderer being an incorporated company have any such retired Officer as one of its Directors, or should the tenderer have in his employment any retired Gazetted Officer as aforesaid, full information of such person shall be submitted along with his tender in the format given in annexure-VI to this chapter of this tender document. (Authority: ACS No.3 to GCC July,2014vide Boards letter No.2014/CEI/CT/O/9/RET dt.22.01.2015)(please attach scanned copy of Annexure-VI duly filled up by the firm).
The Contractor/(firm) must go through the entire tender document along with all attachment for any kind of guidance regarding execution of the job & payment there after. In case any thing is left out or not clear then they should consult the General Condition of Contract & standard Specification as attached (uploaded ).The bidders are also advised to preserve a copy of entire tender document/ (Set) for their convenience.
Electrical (general) work in connection with "Replacement of Old & overage Panel Interlocking station to EI at Belur Station."
EL-HWH-25-21--3468
EL-HWH-25-21--3468
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹78,200
10 Aug 2026
17 Jul 2026
27 Jul 2026
153 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 39,08,028 | ||
| — | — | — | 32,736 | ||
| Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Light point / Fan point / Call Bell point / Indication point / Glow Sign point by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral along with one no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe, junction / circular box, modular switch, ceiling rose and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) ( Make of Modular switch, socket, box, cover plate etc. - Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 96.00 | — | — | |
| — | — | — | 5,100 | ||
| Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for 6A/3 pin plug point by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral along with one no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe, junction / circular box, modular switch, modular plug socket and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) ( Make of Modular switch, socket, box, cover plate etc. - Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 20.00 | — | — | |
| — | — | — | 4,450 | ||
| Conceal wiring on wall / ceiling / floor through PVC pipe of suitable diameter for 6/16A 3 pin plug point by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm., 1100V grade for phase and neutral along with one no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe, junction / circular box, modular switch, modular plug socket and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) ( Make of Modular switch, socket, box, cover plate etc. - Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 10.00 | — | — | |
| — | — | — | 8,650 | ||
| Conceal wiring on wall / ceiling / floor through PVC pipe of suitable diameter for Mobile Charging Plug Board consisting with two nos. 6A/3 pin modular plug socket, two nos. 6A modular switch with one no. 10A modular type MCB by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm., 1100V grade for phase and neutral alongwith one no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe, junction / circular box, modular switch, modular plug socket and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) ( Make of Modular switch, socket, box, cover plate etc. - Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 10.00 | — | — | |
| — | — | — | 6,630 | ||
| Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for modular type Multi plug board consisting with three nos. 6A /5 pin modular plug socket, three nos. 6A modular switch, one no. 6/16A 3 pin modular plug socket, one no.16A modular switch, one no.10A modular type MCB by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm., 1100V grade for phase and neutral along with one no.single core, HRFR / FRLS 'grade, PVC insulated, copper conductor cable of size 1.5 sq.mm., 1100V grade for Earth Conti- nuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe, 'junction / circular box, modular switch, modular plug socket and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) ( Make of Modular switch, socket, box, cover plate etc. - Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 6.00 | — | — | |
| — | — | — | 5,154 | ||
| Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Window AC/ Split AC/ Water Cooler by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, '1100V grade for phase and neutral along with one no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe, junction / circular box, modular switch, ceiling rose and all other associated work and each board comprising with one power unit which includes one double pole modular MCB, one single phase starter and one 6/16A 3 pin socket and plug with indicating light along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) ( Make of Modular switch, socket, box, cover plate etc. - Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 6.00 | — | — | |
| — | — | — | 32,000 | ||
| Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Submain by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for phase and neutral along with one no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm., 1100V grade for Earth Continuity conductor including supply of cable, GI concealed box with modular cover plate, PVC pipe and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) ( Make of Modular switch, socket, box, cover plate etc. - Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 500.00 | — | — | |
| — | — | — | 39,600 | ||
| Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Main line by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 6.0 sq.mm., 1100V grade for phase and neutral along with one no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) ( Make of Modular switch, socket, box, cover plate etc. - Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 300.00 | — | — | |
| — | — | — | 32,200 | ||
| Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Main line by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10.0 sq.mm., 1100V grade for phase and neutral along with one no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) ( Make of Modular switch, socket, box, cover plate etc. - Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 200.00 | — | — | |
| — | — | — | 36,400 | ||
| Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Main line by 4 nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10.0 sq.mm., 1100V grade for three phases and one neutral along with one no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) ( Make of Modular switch, socket, box, cover plate etc. - Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 50.00 | — | — | |
| — | — | — | 3,588 | ||
| Fixing, connection, testing and commissioning of indoor LED luminaire fittings with suitable arrangement. ( LED indoor light fitting will be supplied by Railway ) | — | 52.00 | — | — | |
| — | — | — | 884 | ||
| Fixing, connection and commissioning of Street Light luminaire with suitable dia heavy gauge GI bend pipe with GI clamps made of GI flat of size 40mm x 6mm and GI nut-bolts on structure / wall ( LED Street light fitting will be supplied by Railway ) | — | 4.00 | — | — | |
| — | — | — | 1,568 | ||
| Fixing, connection and commissioning of BLDC Ceiling fan with GI clamps made of GI flat of suitable size and GI nut-bolts. ( BLDC Ceiling Fan will be supplied by Railway ) | — | 32.00 | — | — | |
| — | — | — | 1,136 | ||
| Fixing, connection and commissioning of AC Exhaust Fan with suitable size and shape GI clamps / GI nut & bolts including necessary masonry work ( AC Exhaust Fan will be supplied by Railway ) | — | 8.00 | — | — | |
| — | — | — | 2,19,300 | ||
| Laying of cable underground through 100 mm diameter HDPE pipe (PE-100 grade, PN-10 or higher) by Micro Tunneling cable laying method including supply and jointing of HDPE pipe. ( Cable will be supplied by Railway ) | — | 150.00 | — | — | |
| — | — | — | 42,660 | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting with covering of cable through suitabe dia HDPE pipe (PE-100 grade, PN-10 or higher) including supply of pipe along with refilling the trench and make good of surface as its original condition. ( Cable will be supplied by Railway ) | — | 180.00 | — | — | |
| — | — | — | 1,14,000 | ||
| Trenching and laying of cable under ground by soil cutting with covering of cable through suitable dia HDPE pipe (PE-100 grade, PN-10 or higher) including supply of HDPE pipe alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway ) | — | 750.00 | — | — | |
| — | — | — | 17,000 | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 200.00 | — | — | |
| — | — | — | 49,980 | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 70.00 | — | — | |
| — | — | — | 14,700 | ||
| Trenching, laying under road / track through 50 mm dia GI pipe ( medium gauge ) including supply of GI pipe and commissioning of cable including back filling of trench with excavated soil after laying of cable. ( Cable will be supplied by Railway ) | — | 70.00 | — | — | |
| — | — | — | 9,500 | ||
| Drawing of cable on wall / structure with suitable size and shape GI clamps including supply of suitable size GI Clamp and GI nut- bolts and commissioning of cable ( Cable will be supplied by Railway ) | — | 250.00 | — | — | |
| — | — | — | 8,604 | ||
| Drawing of cable through one no. 2" dia, 3.0 Mtrs. long GI pipe ( Make - Tata / Jindal / Bansal ) for protection of cable on pole with proper GI clamps and GI nuts & bolts including supply of GI pipe ( Cable will be supplied by Railway ) | — | 9.00 | — | — | |
| — | — | — | 98,300 | ||
| Supply of FRP Cable Tray ( Perforated ) type ( Width x Collar x Thick ) - 200 mm x 50 mm x 4 mm including fixing, connec- tion, testing and commissioning of above cable tray with necessary arrangement ( Make - RMC Switchgears / Sintex / Fiber Tech Composite / Ferrotech / Grasp / OBO Bettermann ) | — | 100.00 | — | — | |
| — | — | — | 5,140 | ||
| Supply of Coupler Plate with S/S 316 Bolts ( Width x Collar x Thick ) - 50 mm x 170 mm x 4 mm of 8 sets including fixing, connection, testing and commissioning of above coupler plate with necessary arrangement ( Make - RMC Switchgears / Sintex / Fiber Tech Composite / Ferrotech / Grasp / OBO Bettermann ) | — | 20.00 | — | — | |
| — | — | — | 33,134 | ||
| Supply of heavy gauge GI fabricated Cable tray with GI supporting structure and GI nut-bolts and washer of suitable sizes as per site requirement including fixing and commissioning | — | 0.50 | — | — | |
| — | — | — | 39,279 | ||
| Supply of Auto Change Over Control and Distribution Panel Board of rating 60A, 1Ph, 240V, 50 Hz in 25 KV AC Traction System as per RDSO's specification no. - TI / SPC / PSI / CLS / 0023 or latest including installation, connection and commissioning of above panel alongwith terminal cable connection. ( Make : RDSO approved sources ) | — | 1.00 | — | — | |
| — | — | — | 2,418 | ||
| Supply of Junction Box made of 14 SWG GI sheet of size 450 mm x 300 mm x 250 mm consisting with 2 nos. 63A porcelain fuse units (kitkats) conforming to IS:2086 -1993 complete with hinged door with locking arrangement duly painted with two coats of paint after one coat of anti-corro- sive Red Oxide paint as per Sr. DEE/G/HWH's Drawing No. MISC / E / 2 / 05 including fixing, connection and commi- ssioning of above Junction Box on AT Mast with GI clamps made of GI flat of size 40mm x 6mm with GI nuts-bolts. | — | 2.00 | — | — | |
| — | — | — | 35,356 | ||
| Supply of Dust and vermin proof metal Busbar Chamber consisting of 4 nos. tinned copper busbar of each bar of capacity 200 Amp, 6 way, suitable for 415V, 50Hz supply system including all accessories alongwith fixing, connection, testing and commissioning of incoming and outgoing cables glanding, cable socketing and connection with all suitable arrangement. ( Make - Havells / Standard / HPL / C&S / LK (L&T) / Indoasian ) | — | 4.00 | — | — | |
| — | — | — | 31,440 | ||
| Supply of SPN DB ( Metal Enclosure ), 6 way, 1Ph, 240V, 50Hz, complete with 04 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz as per requirement of load and 1 no. DP RCBO of current rating 40A, 300mA, 10kA, 230V, 50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) | — | 6.00 | — | — | |
| — | — | — | 708 | ||
| Fixing, connection and commissioning of above SPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | 6.00 | — | — | |
| — | — | — | 32,958 | ||
| Supply of TPN MCB DB ( Heavy duty, Outdoor type, UV ray protected, self fire- extinguishing and resistant to abnormal heat and fire up to 650 degree C GWT, shock resistance IK08 or above and IP65 degree of protection grade transparent DB box, similar to ABB Mistral65 - 20 Modules or equivalent ), 3Ph, 50Hz, 415V, 4 way per phase, 415V, 50Hz, complete with total 12 nos. SP MCB of current rating from 6A to 32A, 10 kA, 240 Volt, 50Hz per phase as per requirement of load and one no. FP RCBO 63A, 300mA, 10 kA, 415V, 50Hz, Suitable for AC + Pulsating DC (Type A) + Harmonics ( Make of MCB & RCBO - LK (L&T) / Siemens / ABB / Hager Legrand / Schneider ) ( Make of TPN DB - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / Spelsberg / Hensel / Eaton ) | — | 2.00 | — | — | |
| — | — | — | 286 | ||
| Fixing, connection and commissioning of above TPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement | — | 2.00 | — | — | |
| — | — | — | 58,416 | ||
| Supply, fixing, connection, testing and commissioning of MCCB with Microprocessor Release of breaking capacity 36 kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory 7) All Microprocessor protection-based MCCB / ACB must have facility of individual 'LSIG' fault indication, suitable for Release Range 40-100A, 4 Pole including metal enclosure with internal wiring. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) | — | 3.00 | — | — | |
| — | — | — | 4,69,808 | ||
| Supply of LT Wall Mounted / Floor Mounted Double Door Cubical Outdoor type Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder comprising with the following items for 150 KVA to 200 KVA Load : a) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 100-250 ) Amp, 4 Pole - 2 nos. b) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with above features mentioned in (a) suitable for Release Range ( 40-160 ) Amp., 4 Pole - 2 nos. c) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with above features mentioned in (a) suitable for Release Range ( 25-100 ) Amp., 4 Pole - 4 nos. d) MCCB, 4 Pole, 250 Amp, 415V, 50Hz, 36kA, without protection release, used as bus coupler isolation - 1 no. e) RCBO, 4 Pole, 32 Amp, 415V, 50Hz, 10kA, " Sensitivities - 300mA , Suitable for AC + Pulsating " DC (Type A) + Harmonics - 4 nos. f) RCBO, 4 Pole, 63 Amp, 415V, 50Hz, 10kA, " Sensitivities - 300mA , Suitable for AC + Pulsating " DC (Type A) + Harmonics - 4 nos. g) Tinned Copper Busbar (4 Bar) each of capacity 400 Amps., 415V, 50Hz. - 1 set. h) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having Multiline display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 8 nos. i) CT of suitable ratio for MFM - 6 nos. j) LED indication lamp for 3-Phases for incoming feeders and "ON, OFF & TRIP" indication for all incoming and outgoing feeders - 48 nos. k) Petty Store for control cable, MCBs, gland, socket, fuse, push button, TNC switch, selector switch, r o t a r y handle operating mechanism, spreader terminals, interlocking arrangement, auxiliary contacts, shunt release, terminal blocks & NO/NC relays etc. - 1 job l) Fabrication work for above panel including internal wiring - 1 job. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Energy Meter - Secure / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) | — | 1.00 | — | — | |
| — | — | — | 23,491 | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 1.00 | — | — | |
| — | — | — | 2,42,066 | ||
| Supply of LT cubicle Outdoor Type Wall Mounted Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following : a) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 63-160 ) Amp, 4 Pole - 2 nos. b) MCCB with above features of Release range without protection release, used as bus coupler of capacity 125A, 4 Pole, 415V, 50 Hz - 1 no. c) MCCB with above features mentioned in (a) of Release range of capacity ( 16-40A ), 4 Pole, 415V, 50 Hz - 6 nos. d) Tinned Copper Busbar (4 Bar) each of capacity 150 Amps., 415V, 50Hz. - 1 set. e) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having Multiline display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 2 nos. f) LED indication lamp for 3-Phases for incoming feeders and "ON, OFF & TRIP" indication for all incoming and outgoing feeders - 14 nos. g) Petty Store for cable gland, socket, fuse etc. - 1 job h) complete with all other accessories, internal wiring and fabrication work for above panel - 1 job ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Energy Meter - Secure / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) | — | 1.00 | — | — | |
| — | — | — | 19,662 | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 1.00 | — | — | |
| — | — | — | 17,573 | ||
| Supply of Outdoor pillar box type control panel board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following : a) MCCB with Thermal - Magnetic Release of breaking capacity 36 kA at 415V AC, 50Hz ( Ics = 100% Icu ) suitable for release range 25-32A, 4 Pole - 1 no. b) Astronomical Timer Switch - 2 nos. c) Power Contactor, 3 Pole, 18A, 415V, 50 Hz - 2 nos. complete with fabrication, internal wiring by single core copper conductor cable and all other accessories for above panel ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) | — | 1.00 | — | — | |
| — | — | — | 879 | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 1.00 | — | — | |
| — | — | — | 31,160 | ||
| Supply, installation and commissioning of different size and suitable width self- illuminated LED display system with all necessary accessories : 1) Aluminium panel - 3mm Pvdf coated aluminium composite panel.(Make-Alstone/Aludecor/Alstom/ Timexbond ) Designed artwork by ER shall be on router cut 3D alphabets of 2" depth to be flushed with the ACP sheet. 2) 1" X 1" 18g MS square pipe structure with red oxide and white enamel paint, ISI marked. 3) Imported translucent Acrylic sheet for making alphabets : a) Physical form - Sheets b) Thickness range - 3mm (+/-) 0.5mm c) Colour - White mild translucent d) Outdoor Stability - UV Stabilised e) Output - Excellent to cast Vinyl and self display f) Make - acast / Mitsubishi / sumiplex 4) 26g Galvanised iron sheet / 3mm acp for back panel. ( Make - Tata / Jindal / Bansal ) 5) Light Emit- -ting Diodes ( LED ) sign modules - ( Make of LED chip - NICHIA/ CRE / OSRAM/ SEOUL/ PHILIPS/ LUMILEDS/ AVAGO ) a) Power consumption - 1 W each module b) Operating Temperature - (-) 40 deg to 60 deg C c) Viewing Angle - 150 degree d) Input Voltage - 12V DC e) Protection Class inbuilt - IP 66 or higher f) Standards - UL94HB g) Certifications - UL. CE. C tick. ROHS h) Housing material of the module - PC & ROHS compliant i) Colour - White / Red / Warm white 6) Power Drivers -( Make-Union / Meanwell or similar ) a) Protection Class - IP 65 b)Rated Supply Voltage - 108V - 305V AC c) Fre- -quency - 50/60 Hz d) Power Factor - greater than 0.9 e) Driver Output current - .8A to 25 Ampere f) Operating Temperature - (-) 40 deg to 60 deg C g) Output Voltage Tolerance -10% | — | 40.00 | — | — | |
| — | — | — | 19,260 | ||
| Supply of Maintenance Free Copper Bonded Solid Earthing Rods with 25 kg Earth Enhance Compound with below specifications : a) Certified by CPRI and NABL Accredaited Lab b) ROHS certified c) Low Carbon High Tensile Rod d) Length of Electrode 3000 mm (3 Meter) e) Rod dia 17.2 mm f) Molecular Copper Plating thickness 254 microns as per UL 467 g) Connection terminal size 32 mm x 6 mm with 10 mm hole along with nut bolt and washer including installation, testing and commissioning as per RDSO spec. no. RDSO/SPN/197 ver. 1.0 or latest and conforming to RDSO Drg. No. SDO/RDSO/E&B/001 or latest. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann ) | — | 2.00 | — | — | |
| — | — | — | 1,356 | ||
| Supply of Heavy Duty Fiber Reinforced Polymers Pit Cover with below specifications : a) Weight Carrying Capacity 5 Ton b) Lockable arrangement c) Top Dia 162 mm d) Bottom Dia 242 mm e) Height 230 mm f) As per IEC 62561-5 g) M5 Nut Bolts HDG 4.6, 30 mm length with 2 nos. of plain washer h) Tested by NABL Accrediated LAB including installation, testing and commissioning. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann ) | — | 2.00 | — | — | |
| — | — | — | 8,848 | ||
| Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) | — | 4.00 | — | — | |
| — | — | — | 3,65,400 | ||
| Supply of Hi efficient DC Inverter Side/Top discharge VRF Out door units with Nominal Capacity 8 HP equipped with Variable refrigerant flow system (only Cooling), comprising Inverter driven Scroll Compressor / Twin Rotary Compressor with a wide range of frequency from 15 to 120 rps ( R-410A refrigerant gas). All the unit shall be provided with microprocessor based control advance refrigerant control, Liquid back flow protection, precise oil control technology, 3ph/1ph DC motor condenser fan motor, subcooling through dual tube heat exchanger & various electrical protection like-phase sequence, high/low voltage protection, compressor overload protection, temperature & pressure protection including installation testing and commissioning. ( Make : O General / Fujitsu-General / Mitsubishi Electric / Panasonic / Samsung / Carrier / Toshiba / LG / Hitachi / Trane / Voltas ) | — | 2.00 | — | — | |
| — | — | — | 1,70,000 | ||
| Supply of High Static Ductable Indoor Unit with nominal capacity 8.0 HP, Cooling capacity not less than 22 KW, air flow not less than 2528 CFM & sound pressure level not more than 53 db with Touch Panel Remote including installation, testing and commissioning. ( Make : O General / Fujitsu-General / Mitsubishi Electric / Panasonic / Samsung / Carrier / Toshiba / LG / Hitachi / Trane / Voltas ) | — | 2.00 | — | — | |
| — | — | — | 10,020 | ||
| Supply, Testing, Commisioning, Trial run of the entire VRF system including nitrogen Flusing, charging of R 410A Refrigerant Gas for Topping UP including Pressure testing and Vacuumising etc., as per direction and satisfaction of the Incharge. | — | 12.00 | — | — | |
| — | — | — | 22,040 | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 22.2mm OD with 19mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | 40.00 | — | — | |
| — | — | — | 5,480 | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 19.05mm OD with 19mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | 10.00 | — | — | |
| — | — | — | 6,510 | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 19.05mm OD with 13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | 10.00 | — | — | |
| — | — | — | 11,140 | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 15.8mm OD with 19/13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | 20.00 | — | — | |
| — | — | — | 52,050 | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 12.7mm OD with 13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | 150.00 | — | — | |
| — | — | — | 7,480 | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 9.52mm OD with 13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | 20.00 | — | — | |
| — | — | — | 8,520 | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 6.35mm OD with 13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | 20.00 | — | — | |
| — | — | — | 5,440 | ||
| Supply of Rigid PVC Drain Piping of 40 mm dia complete with , fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation including Installation Testing and commissioning. | — | 40.00 | — | — | |
| — | — | — | 2,380 | ||
| Supply of Rigid PVC Drain Piping of 32 mm dia complete with , fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation including Installation Testing and commissioning. | — | 20.00 | — | — | |
| — | — | — | 2,040 | ||
| Supply of Rigid PVC Drain Piping of 25 mm dia complete with , fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation including Installation Testing and commissioning. | — | 20.00 | — | — | |
| — | — | — | 1,38,840 | ||
| Supply, Erection, Smoke Testing of 120GSM GI Factory Fabricated / Site Fabricated - Rectangular Duct as per aesthetic look & duct will be with supports and turning vanes as per specifications & drawings. 0.63 mm (24G) thick. GI Duct Make: SAIL / TATA / JINDAL. Factory Fabricated Duct make : GP Spria, Asawa. | — | 120.00 | — | — | |
| — | — | — | 69,000 | ||
| Supply, Erection, Smoke Testing of 120GSM GI Factory Fabricated / Site Fabricated - Rectangular Duct as per aesthetic look & duct will be with supports and turning vanes as per specifications & drawings. 0.8 mm (22G) thick. GI Duct Make : SAIL / TATA / JINDAL. Factory Fabricated Duct make : GP Spria, Asawa. | — | 50.00 | — | — | |
| — | — | — | 45,220 | ||
| Supply and installation of thermal duct insulation of 13mm thickness with fire retardant (Class: O) AL foil faced closed nitrile rubber insula- tion on duct with necessary pasting. ( Make : Acoflex/Araflex/Supreme/K-flex ) | — | 70.00 | — | — | |
| — | — | — | 30,000 | ||
| Supply of Acoustic Insulation of 48 kg/m3 x 12mm thick Rigid Board with RP tissue and 30G Al. perforated sheet including installation, testing and commissioning. | — | 40.00 | — | — | |
| — | — | — | 57,000 | ||
| Supply, Fixing, Testing and Commissioning of GI Fusible link fire dampers in supply air duct/ main branch as and where required with all accessories. The damper shall also be closed in the event of fire complete as required and as per specifications and atleast 90 minutes rating. ( Make : System Air / Green Air / Air Enterprise ) | — | 6.00 | — | — | |
| — | — | — | 33,384 | ||
| Supply, Erection, Testing and Commissioing of Supply & Return air Aluminium Continious Grill & Square Diffuser as per aesthetic look. ( Make : System Air / Green Air / Air Enterprise ) | — | 6.00 | — | — | |
| — | — | — | 33,384 | ||
| Supply, Erection, Testing and Commissioning of Supply air Aluminium Coller Damper. ( Make : System Air / Green Air / Air Enterprise ) | — | 6.00 | — | — | |
| — | — | — | 9,000 | ||
| Supply of Canvas and Connection at IDU mouth and Damper including installation, testing and commissioning. | — | 6.00 | — | — | |
| — | — | — | 7,600 | ||
| Supply, Fabrication & Installation work of MS Structure duly painted for Outdoor units including Vibration pad etc. | — | 50.00 | — | — | |
| — | — | — | 21,924 | ||
| Supply, installation, Testing and commissioning of Suction Filter and Ball Valve for ODU. | — | 4.00 | — | — | |
| — | — | — | 19,690 | ||
| Supply and fixing of Three Phase timer panel suitable to 5.5TR - 11TR ductable type AC machine. It should be consisting of Double door TPN BD with 1 no. 40A TP MCB as incommer & 1 no. 40A TP power contactor with 2NO + 2NC auxiliary contact 1 No 24Hrs digital timer switch, 2 Way auto - manual bypass selection switch and 02 nos. indicating lamp with 1 no. 6A SP MCB for control circuit including necessary interconnection and earthing attachment for 3 phase AC machine. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider ) | — | 1.00 | — | — | |
| — | — | — | 27,200 | ||
| Supply and Installation of GI slotted Tray for hard copper piping for the safety of nirtile insulation over copper pipe ( Size 150mm x 50mm x 1.5mm ) | — | 50.00 | — | — | |
| — | — | — | 23,220 | ||
| Supply and Installation of GI slotted Tray for hard copper piping for the safety of nirtile insulation over copper pipe ( Size 300mm x 50mm x 1.5mm ) | — | 30.00 | — | — | |
| — | — | — | 57,000 | ||
| Supply and providing drop ceiling to cover the indoor units and supply of air duct, with 3mm thick ACP sheet as per manufacture's specification on the frame work fabricated from Aluminium hollow rectangular section of size 50mm x 25mm (2mm thick) and duly suspended by Aluminium hollow rectangular section of size 50mm x 38 mm (2mm thick) and silicon sealant complete in all respect as per direction of IC. | — | 20.00 | — | — | |
| — | — | — | 4,000 | ||
| Supply of Trapdoor for maintenance of IDU. | — | 2.00 | — | — | |
| — | — | — | 1,72,872 | ||
| Supply of Split Air Conditiontioner unit Inverter type of cap. 2 TR minimum BEE 5 star rated, rotary compressor type, both coils made of copper, having Eco-friendly type refrgerant, copper pipe of 3 Mtr suitable for operation on 1 Ph, 230V, 50Hz supply system with varibale speed including standard installation kit and other accessories with 1 year warranty on the product, 5 years on PCB and 10 years on the compressor. ( Make - O General / LG / Samsung / Carrier / Panasonic / Voltas / Daikin / Hitachi ) | — | 4.00 | — | — | |
| — | — | — | 9,616 | ||
| Installation, testing and commissioning of 2 TR Split AC machine including outdoor unit with MS angle stand including necessary power cable and all other accessories. | — | 4.00 | — | — | |
| — | — | — | 20,760 | ||
| Supply of Refrigerant Copper Pipe line ( suction & discharge ) of required size and length with nitrile rubber insulation and all other accessories including fitment, connection and commissioning of above pipe line for above split AC machines. | — | 30.00 | — | — | |
| — | — | — | 6,300 | ||
| Supply of Drainage system for each above Split AC machines for discharge of condensate water with all accessories by 1.5 inch dia PVC pipe and drain line of each machine connected by 0.5 inch cotton braided PVC flexible pipe with all other accessories alongwith fitment and commissioning. | — | 60.00 | — | — | |
| — | — | — | 5,96,140 | ||
| Goods & Services Tax ( at present @ 18% ) | Lumpsum 596140.00 | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Annexure-VA.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf
ATTACHMENT
HTLTstandardspecification.pdf
ATTACHMENT
Advancecorrectionslips.pdf
ATTACHMENT
3468Clause_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .