| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-01₹9.6 LAccepted-AOC | L-01 | Accepted-AOC Being lowest | |
| 2 | L-02₹10.0 L+₹6,592.50 (0.67%)Rejected-Finance | L-02 | Rejected-Finance Not being lowest | |
| 3 | L-03₹10.0 L+₹10,649.45 (1.08%)Rejected-Finance | L-03 | Rejected-Finance Not being lowest | |
| 4 | L-04₹10.1 L+₹19,910.17 (2.01%)Rejected-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L-04 | Rejected-Finance Not being lowest | |
| 5 | L-05₹10.2 L+₹28,745.29 (2.91%)Rejected-Finance | L-05 | Rejected-Finance Not being lowest |
Tender Value
₹9.2 L
EMD Value
₹18,400
Closing Date
9 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Darjeeling
P.O. Jalapahar Dist- Darjeeling (WB) Pin- 734103
REPAIR MAINT OF LIGHTENING PROTECTION SYSTEM GARDEN LIGHTS AND CONTROLLING DEVICES AT JALAPAHAR UNDER AGE I DARJEELING
2022_MES_537512_1
8969/E8
Open Tender
Civil Works
Item Rate
182 days
AGE (I) Darjeeling
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Darjeeling
₹18,400
Yes
25 Aug 2022
12 Jul 2022
11 Aug 2022
12 Jul 2022
9 Aug 2022
27 Jul 2022
12 Jul 2022 - 19 Jul 2022
Amount
Excavation in Trenches, not exc. 1.50 Metre wide and not exc 1.50 Metre in depth for any type of foundation/cable trench and getting out in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
Supply & laying locally available, well burnt Sub-class ‘B’ Bricks/ Fly Ash bricks of size 250x125x75mm (± 8% tolerance), laying perpandicular to UG Cable laid in trenches over Sand Cushion as Cable Protection, complete all as specified and as directed.
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laying in trenches or fixing with Walls/Poles, segreating serviceable Bricks/Precast covers, Pipes, Cables etc, and keep in safe custody for reuse, complete all as specified and as directed. NOTE: Earthwork will be measured and paid under appropriate Items.
S&F in-repair of Air termination, single pointed aluminium rod 12mm dia and 300mm long, complete all as specified and as directed.
S&F in-repair of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all as specified and as directed.
S&F in-repair of Aluminium strip of size 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground., complete all as specified and as directed.
S&F in-repair of Galvanised iron strip of size 32 x 6mm buried in ground., complete all as specified and as directed.
Supply & laying of LT XLPE Cable, sheathed PVC insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm 2.0 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ above floor/ fixing on poles including and Testing, complete all as specified and as directed. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items. MAKE:- KEI/POLYCAB/ HAVELLS/ FINOLEX/ RR KABEL
S&F in-repair of Galvanised Iron Pipe 40mm bore (dia) ‘Light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. MAKE:- JINDAL/BANSAL/ NEZONE/ TATA
S&F in-repair of Galvanised Iron Pipe 40mm bore (dia) ‘Medium grade’ for protection of lightening conductor, fixed to wall/floor/ceiling with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. MAKE:- JINDAL/BANSAL/ NEZONE/ TATA
S&F in-repair of Pole Box/Junction Box of size 155 X 210 X 95mm (LxBxH) made out of Polycarbonate material totally enclosed, dust and vermin proof, door pasted with rubber gasket, water tight IP 66/67 protection single leaf shutter in front having proper locking arrangements, including provision of suitable connector for single phase connections loop in and out 10 to 16 Sqmm 4.0 Core aluminium armoured cable branch out 1.5 Sqmm single core copper PC insulated cable and MCB SP 06 amps- 01 No and mounted on security light pole with suitable clamps (GI Flat iron of 25x3mm), nuts, bolts, complete all as specified and directed. Cat No.: KF 2525 G of make Hensel or quivalent of make Sintex (GSJB 3750).
S&F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 Street light fitting luminaire with high power LEDs as light source and electronic driver of capacity 90 watts with pre wired and lens embedded PC cover having Top opening seperate driver compartment and necessary mounting arrangements, including taking down old unserviceable light fitting, complete all as specified and as directed. CAT No.- ENDURAPEARLPLUSSL90WLED757PASYTOPCASTCC of Make HAVELLS/Cat No.- BRTFG 90W LED CR WW of make- BAJAJ/Cat No.- BRP410 LED 091 CW HE MR PC S2 PSU GR of make- PHILLIPS/Cat No.- CRP-404-90-30-SL-GL-NSG of make- CROMPTON GREAVES
S&F IP-65 rated robust designed LED bollard garden Light Fitting with black ABS Plastic Spigot, Spun Aluminium Canopy with Opal Acrylic Diffuser and provision of LED Lamp 10 Watt duly pre-wired, including embedding on 150x150x300mm PCC Block 1:3:6 (20mm Graded Aggregate) and taking down the old unserviceable one, complete as all specified and as directed. Cat No.- LBLTW-10-CDL of Make- Crompton Greaves/Cat No.- BGBOM 650 9W LED WW of make Bajaj/ Cat No.- BCP400 LED09 D CW PSU GR S1 of make Phillips/ Cat No.- CONENXGBLS8WLEDPSYM830TOPC of make Havells
S&F decorative LED Post Top lantern light made in die cast aluminium spigot housing with decorative clear opal Acrylic diffuser and IP-65 protection suitable for 40 Watt LED bulb with necessary elecrical connections with adequate size of Nuts and Bolts including taking down existing unserviceable one, complete as all specified and as directed. Cat No.- LPTO-40-CDL of Make- Crompton Greaves/ Cat No.- BRIL 40W LED WW of make Bajaj/ Cat No.- BGP161 LED2500/NW PSU 220-240V 7043 IN of make Phillips/ Cat No.- RUBYPT40WLED757PSYMTOPC of make Havells
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to GI strip 32x6 as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, lugs, complete in all respect, GI earth strip protected by 40 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed including proper lugs, including disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed.
S&F in-repair of MCCB 4 Pole, 415 Volts, 100 Amps, with Thermal Magnetic release, overload, short circuit fault protection 3 phase, breaking capacity 25 KA, Ics=100% of Icu, with Spreader terminal of both ends connecting and testing, complete all as specified and as directed. Make- Legrand/ L&T/ Schnider/Siemens
S&F in-repair of MCCB 4 Pole, 415 Volts, 160 Amps, with Thermal Magnetic release, overload, short circuit fault protection 3 phase, breaking capacity 25 KA, Ics=100% of Icu, with Spreader terminal of both ends connecting and testing, complete all as specified and as directed. Make- Legrand/ L&T/ Schnider/Siemens
S&F in-repair of onload changeover switch 4 Pole, 415 Volts, 200 Amps, with terminal Shrouds, Source Separator and Phase Barriers, Conforms to IEC 60947-3, connecting and testing, complete all as specified and as directed. Make- Legrand/ L&T/ Schnider/Havells
S&F in-repair of onload changeover switch 4 Pole, 415 Volts, 100 Amps, with terminal Shrouds, Source Separator and Phase Barriers, Conforms to IEC 60947-3, connecting and testing, complete all as specified and as directed. Make- Legrand/ L&T/ Schnider/Havells
M&L for Multistandarded Copper Conductor cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to street light Fitting, Post Top Lantern & etc including taking down old unserviceable cable complete all as specified and as directed. Make :- Polycab/Plaza/Havells/KEI
SANJAY KAUSHIK
Darjeeling Enterprises
Damdoo Bhutia
M/S TSHERING BHUTIA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .