Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | ₹34.7 L Quoted ₹34.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹35.8 L+₹85,917.50 (2.46%)Rejected-Finance JAISALMER | JAISALMER | RAJASTHAN | 342310 | ₹35.8 L+₹85,917.50 (2.46%) | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹37.5 L+₹2.6 L (7.40%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹37.5 L+₹2.6 L (7.40%) | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹41.3 L+₹6.4 L (18.3%)Rejected-Finance 521 DR K L ACHAL VANSHI COLONY JAISALMER 345001 RAJ | JAISALMER | RAJASTHAN | 345001 | ₹41.3 L+₹6.4 L (18.3%) | L4 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | MARUDHARA CONSTRUCTION COMPANY L4 | S K TRADER L2 | SUMIT ENTERPRISES L3 | M/S VISHNOI ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L removing damaged APP modified water proofing membrane and cleaning the surface by wire brush and water complete all as specified and directed | 780 | SQM | 30 ₹23,400 | 20 ₹15,600 | 15 ₹11,700 Lowest | 50 ₹39,000 |
| 2.00 | M&L for 20mm thick cement screed in cement mortar 1:4, including finishing even and smooth with out using extra cement mixed with water proofing compound @3% by weight of cement over cleaned roof surface, as in grading to RCC roof surface,complete all as specified. Note - Water proofing compound shall be measured and paid separately. | 780 | Sqm | 250 ₹1,95,000 | 350 ₹2,73,000 | 210 ₹1,63,800 | 180 ₹1,40,400 Lowest |
| 3.00 | Supply only integral water proofing compound complete all as specified and directed | 217.15 | Kg | 80 ₹17,372 | 60 ₹13,029 | 100 ₹21,715 | 10 ₹2,171.5 Lowest |
| 4.00 | M & L for applying fibre reinorcement elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflecivity index (SRI) upto 105 on top of concrete roof in three coats @ 10.76 ltr/10 Sqm. One coat of self -priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid 500 microns) after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. Make : CICO Thermoseal XL or equivalent in MYK arment , BASF,FOSROC. | 780 | Sqm | 800 ₹6,24,000 | 600 ₹4,68,000 | 550 ₹4,29,000 Lowest | 1,280 ₹9,98,400 |
| 5.00 | Demolition of PCC of any description not otherwise specially provided for complete all as spd and dir. | 10 | Cum | 300 ₹3,000 | 280 ₹2,800 | 299 ₹2,990 | 200 ₹2,000 Lowest |
| 6.00 | Cleaning of roughened surface of sunken floor by brushing with wire brush to remove all dirt and apply a coat of cement slurry with 3.00 Kg of cement per sqm and Rendering 15mm thick in CM 1:3 using WPC finished rough (sunken floor/wall) and then applying two course treatment as follow :-
(i) Applying bitumen primer @ 0.40Kg/Sqm
(ii) Laying APP (Atactic polypropylene) modified membrance 3mm thick and weighting not less than 3.50 Kg/Sqm with 100 GSM/Sqm non woven polyester mat as center core reinforcement, laid with 75 mm side over lap and 100mm end over lap. The membrane has to be laid with LPG torch and over lap sealed and finished neat.
(iii) 40mm bore GI pipe for spout pipe length 0.75m | 80 | Sqm | 1,500 ₹1,20,000 | 700 ₹56,000 Lowest | 3,000 ₹2,40,000 | 1,000 ₹80,000 |
| 7.00 | Cement concrete Type E2 1:5:10 (40mm stone agg ) as filling in sunken floor as in any situation complete all as spd and dir. | 7 | Cum | 3,500 ₹24,500 | 4,000 ₹28,000 | 2,800 ₹19,600 Lowest | 4,000 ₹28,000 |
| 8.00 | Cement concrete (75mm thick) type B-1, 1:2:4 (20mm graded aggregate) as in floor cpmplete all as spd and dir | 24 | Sqm | 400 ₹9,600 | 300 ₹7,200 | 290 ₹6,960 Lowest | 400 ₹9,600 |
| 9.00 | S & F in repair vitreous squating pan of orissa pattern long pan of size 580 mm white with cast iron p or s trap with back inlet including flush pipe of suitable length to connection with existing cistern & make good complete all as spd and dir. | 20 | Each | 3,000 ₹60,000 | 2,500 ₹50,000 | 2,000 ₹40,000 Lowest | 2,000 ₹40,000 Lowest |
| 10.00 | S&F Vitreous china wash down water closet pan “Pedestal Pattern” white with wc seat cover coloured closed pattern with flat bottom and mild steel chromium plated or aluminized hinging device including pvc flush pipe and joints etc and connection to drain, flushing, pipe, anti- syphonage pipe, and fixing arrangements with fixing bolts etc ,complete all as specified and directed | 20 | Each | 2,500 ₹50,000 Lowest | 3,500 ₹70,000 | 4,000 ₹80,000 | 3,000 ₹60,000 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
30 Jul 2026, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR TO LEAKAGE/ SEEPAGE IN MD AND OTM ACCN INCLUDING REPAIR/MAINT OF DRAINS IN DOMESTIC AREA AT AF STN JAISALMER
2026_MES_776139_1
8426/GE/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹80,000
Yes
3 Sept 2026
3 Jul 2026
1 Aug 2026
3 Jul 2026
30 Jul 2026
17 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L removing damaged APP modified water proofing membrane and cleaning the surface by wire brush and water complete all as specified and directed | 780 | SQM | - | - |
| 2 | M&L for 20mm thick cement screed in cement mortar 1:4, including finishing even and smooth with out using extra cement mixed with water proofing compound @3% by weight of cement over cleaned roof surface, as in grading to RCC roof surface,complete all as specified. Note - Water proofing compound shall be measured and paid separately. | - | Sqm | - | - |
| 3 | Supply only integral water proofing compound complete all as specified and directed | 217.15 | Kg | - | - |
| 4 | M & L for applying fibre reinorcement elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflecivity index (SRI) upto 105 on top of concrete roof in three coats @ 10.76 ltr/10 Sqm. One coat of self -priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid 500 microns) after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. Make : CICO Thermoseal XL or equivalent in MYK arment , BASF,FOSROC. | - | Sqm | - | - |
| 5 | Demolition of PCC of any description not otherwise specially provided for complete all as spd and dir. | 10 | Cum | - | - |
| 6 | Cleaning of roughened surface of sunken floor by brushing with wire brush to remove all dirt and apply a coat of cement slurry with 3.00 Kg of cement per sqm and Rendering 15mm thick in CM 1:3 using WPC finished rough (sunken floor/wall) and then applying two course treatment as follow :-
(i) Applying bitumen primer @ 0.40Kg/Sqm
(ii) Laying APP (Atactic polypropylene) modified membrance 3mm thick and weighting not less than 3.50 Kg/Sqm with 100 GSM/Sqm non woven polyester mat as center core reinforcement, laid with 75 mm side over lap and 100mm end over lap. The membrane has to be laid with LPG torch and over lap sealed and finished neat.
(iii) 40mm bore GI pipe for spout pipe length 0.75m | 80 | Sqm | - | - |
| 7 | Cement concrete Type E2 1:5:10 (40mm stone agg ) as filling in sunken floor as in any situation complete all as spd and dir. | 7 | Cum | - | - |
| 8 | Cement concrete (75mm thick) type B-1, 1:2:4 (20mm graded aggregate) as in floor cpmplete all as spd and dir | 24 | Sqm | - | - |
| 9 | S & F in repair vitreous squating pan of orissa pattern long pan of size 580 mm white with cast iron p or s trap with back inlet including flush pipe of suitable length to connection with existing cistern & make good complete all as spd and dir. | 20 | Each | - | - |
| 10 | S&F Vitreous china wash down water closet pan “Pedestal Pattern” white with wc seat cover coloured closed pattern with flat bottom and mild steel chromium plated or aluminized hinging device including pvc flush pipe and joints etc and connection to drain, flushing, pipe, anti- syphonage pipe, and fixing arrangements with fixing bolts etc ,complete all as specified and directed | 20 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_869139.xls
BOQ • 0.37 MB
8426TENDERDOCU.pdf
Tender Documents • 1.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .