Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-AOC BAILIPOTA NARAJOLE DASPUR PASCHIM MEDINIPUR | NARAJOLE | PASCHIM MEDINIPUR | WEST BENGAL | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹2.6 L+₹510.50 (0.20%)Rejected-Finance 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L2 | Rejected-Finance high rate offered | |
| 3 | L3₹2.7 L+₹15,436.50 (5.97%)Rejected-Finance 210 14 R B AVENUE KOL 29 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | L3 | Rejected-Finance high rate offered | |
| 4 | l4₹3.2 L+₹62,521 (24.2%)Rejected-Finance 43 REPON LANE KOL 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | l4 | Rejected-Finance highest rate offered | |
| 5 | Rejected-Technical 3204 B B CHATTERJEE ROAD KOL 42 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | - | Rejected-Technical NOT submit proper valid credential |
Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
6 Jan 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE II CKHED
P12 CIT Road 1st floor Kol 14
Infrastructure development of newly set up Skill Lab at Forensic building under NRSMC AND H SITC of LT Cubicle panel at Subhash Mukherjee Building Under NRS MC AND H
2023_WBPWD_610356_1
WBPWD/EE-II/CKHED/NIT-42/23-24 2nd call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
NRS MCH
AS PER NIT
4 documents required · 4 mandatory
₹6,000
P12 CIT Road 1st floor Kol 14
8 Aug 2024
29 Nov 2023
10 Jan 2024
29 Nov 2023
6 Jan 2024
6 Dec 2023
5 Dec 2023
Amount
SITC of LT Cubicle type fully compartmentalized floor mounted panel board with multi-tier arrangement, having rigid & self supporting structure fabricated with sufficient no. of channels (50x15x15mm) and covered by 14 SWG CRCA sheet with base structure by 75x40x4mm channel. All incoming, outgoing SFUs are to be housed in respective compartments with hinged & gasketted doors at the front. All the doors should have panel lock arrangements in such a fashion that it can not be unlocked unless the respective feeder remains OFF. The rear of panel should have gasketted wire net guard for ventilation and arrangement shall be made for easy access to each compartment by providing rear doors with locking system. The panel is to be properly gasketted to prevent the dust & vermin. All vertical & horizontal bus-bar chambers are to be properly arranged & all electrical switches, bus-bars are to be fixed by MS nut-bolts on suitable hylam board / non-hygroscopic insulators of adequate size & dimension. The outgoing feeder connections from respective switches are to be made at the rear side of the panel by means of bus-bar / multicore copper cables, to be terminated on bolted type terminals for cable connections or bush insulators for bus connection. Panel should be incorporated with the following electrical accessories complete with all necessary connections and inter-connections by suitable size of copper flat bar/PVC insulated copper wire as directions of E.I.C. (Approx. size of Panel: 1200mm (H) X1800(W) X 250mm(D) as directed by EIC.
Incomer : i) 415V, 250A, FP MCCB [Cat no: 0256 63 ], [Make :Legrand].-----1 no. ii)315A, 4 x 40x5mm bars BBC made of 99.99% electrolytic tinned copper flats supported on non-hygroscopic chair with colour codeing)........................01No. Outgoing : i)415V, 163A, FP MCCB , [Make : Legrand/Schneider] -2 no. ii)415V, 100A, FP MCCB, [Make :Legrand/Schneider] -2 no iii)415V, 63A, FP MCCB, [Make : Legrand/Schneider] -2 no. Digital Multifanction Panel meter measured by(Amp,voltage & frequency) with CT. [Make-L&T]-----1 Nos CT ratio 300/5--3no,[Make : A&E/KAPPA] R-Y-B LED Indicator Lamp --- 3 no.[Make : Philips] Slide Lock Fuse --- 3Nos.[Make : Legrand ] 6" x 4" E.I. Danger Board.................01 No.
S&F 415V 6 way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall and mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.[Make : Legrand/Schneider] Incoming - 415V 63A FPMCB isolator(1no) Outgoing - 10KA 6-32A SPMCB-(18nos)
S&F 415V 2+12 way double door SPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall and mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Incoming - 220V 40A DPMCB isolator(1no) Outgoing - 10KA 6-32A SPMCB-(12nos) [Make : Legrand/Schneider]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (RRcable/glostar/finolex) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required, as directed by EIC.
a) 4x70sqmm + 2x16sqmm flexible cu wire
b) 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [E9-1.(D1) & E3-7(a)]
c) 2x6sqmm + 1x4sqmm
d) 3x1.5sqmm
Finising the end of above PVC insulated & unsheathed copper wire,as directed by EIC.
a) 4x70sqmm + 2x16sqmm
b)4x10sqmm+2x6sqmm
c) 2x6sqmm + 1x4sqmm
Supply & Laying of cable of 1.1KV grade, XLPE,cable on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting (Make: Gloster/Finolex), as directed by EIC.
a) 4 core 50 sqmm
a) 4 core 25 sqmm
S&F compression type cable gland complete with brass gland, bursh ring & rubber ring for dust & moisture proof entry of 1.1 KV 4 core following size XLPE/A cable, incl. finishing the end with sockets, by crimping method ,as directed by EIC.
a) 4 core 50 sqmm
a) 4 core 25 sqmm
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1x4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S&F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level, incl. excavation of approx 1 m3 of soft soil for installation of Earth Electrode and filling & ramming, by ISI-Medium GI Pipe for soft soil.
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.as to GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as per GS.
Making Brick chamber platform for placing of L.T. Cibicle panel board (approx. Size : 6'ft.X3'-6"X3'ft.ft) from floor level incl. plastering and neat c ement finish by cement, sand & gradd ed stone cheaps (6:4:1) as per direction of E.I.C.
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
ALPHA ELECTRICALS
OVERSEAS TRADING AND SUPPLIES CORPORATION
NEW MODERN COOLING
technical_1295258.pdf
PDF • 0.13 MB
techsummary_1295258.pdf
PDF • 0.15 MB
finance_1295258.pdf
PDF • 0.10 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1295258.pdf
PDF • 0.15 MB
WA.pdf
PDF • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .