| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78,238Accepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹95,532+₹17,294 (22.1%)Rejected-Finance | L2 | Rejected-Finance REJECTED |
| Sl No | Description | Qty | Unit | KRIZ INDIA SOLUTIONS L1 | R G VENTURES L2 |
|---|---|---|---|---|---|
| 1.00Annual Rate Contract Tender for OFC Networking and Equipment’s | |||||
| 2.00 | 6 Core Cable Single mode Corrugated Steel Tape Armour Outer Sheath, Water BlockingGel , Multi/Uni loose tube, outdoor Directly Buried, 9/125 micron, Meter marking Per Meter, OFC cable with minimum 10 Years of life by OEM | 1 | Per Meter | 26 ₹26 Lowest | 31 ₹31 |
| 3.00 | 12 Core Cable Single mode Corrugated Steel Tape Armour Outer Sheath, Water BlockingGel , Multi/Uni loose tube, outdoor Directly Buried, 9/125 micron, Meter marking Per Meter, OFC cable with minimum 10 Years of life by OEM | 1 | Per Meter | 28 ₹28 Lowest | 35 ₹35 |
| 4.00 | 24 Core Cable Single mode Corrugated Steel Tape Armour Outer Sheath, Water BlockingGel , Multi/Uni loose tube, outdoor Directly Buried, 9/125 micron, Meter marking Per Meter, OFC cable with minimum 10 Years of life by OEM | 1 | Per Meter | 32 ₹32 Lowest | 38 ₹38 |
| 5.00 | 48 Core Cable Single mode Corrugated Steel Tape Armour Outer Sheath, Water BlockingGel , Multi/Uni loose tube, outdoor Directly Buried, 9/125 micron, Meter marking Per Meter, OFC cable with minimum 10 Years of life by OEM | 1 | Per Meter | 39 ₹39 Lowest | 45 ₹45 |
| 6.00 | 96 Core Cable Single mode Corrugated Steel Tape Armour Outer Sheath, Water BlockingGel , Multi/Uni loose tube, outdoor Directly Buried, 9/125 micron, Meter marking Per Meter, OFC cable with minimum 10 Years of life by OEM | 1 | Per Meter | 59 ₹59 Lowest | 70 ₹70 |
| 7.00 | 6 Core Cable Single mode Self-Supporting Metal-Free Aerial, Multi/Uni loose tube outdoor, 9/125 micron, Double sheath protection, Longitudinal water protection, Strain-free fiber OFC cable with minimum 5 Years of life by OEM | 1 | Per Meter | 18 ₹18 Lowest | 22 ₹22 |
| 8.00 | 12 Core Cable Single mode Self-Supporting Metal-Free Aerial, Multi/Uni loose tube outdoor, 9/125 micron, Double sheath protection, Longitudinal water protection, Strain-free fiber OFC cable with minimum 5 Years of life by OEM | 1 | Per Meter | 21 ₹21 Lowest | 25 ₹25 |
| 9.00 | 4 Core Cable Single mode outdoor Drop cable, Multi/Uni loose tube, 9/125 micron, Ribbon fiber design, Stainless Steel wire for Aerial installation, ARP for more tensile strength and stiffness, Aramid yarns around central tube OFC cable with minimum 5 Years of life by OEM | 1 | Per Meter | 15 ₹15 Lowest | 20 ₹20 |
| 10.00 | 6 Core Cable Single mode outdoor Drop cable, Multi/Uni loose tube, 9/125 micron, Ribbon fiber design, Stainless Steel wire for Aerial installation, ARP for more tensile strength and stiffness, Aramid yarns around central tube OFC cable with minimum 5 Years of life by OEM | 1 | Per Meter | 15 ₹15 Lowest | 20 ₹20 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
5 Oct 2024, 5:00 pmClosed
Registrar, DR BAMU chh Sambhjinagar
DR BAMU chh Sambhjinagar
ARC for OFC Networking Equipments
2024_BAMU_1081762_6
E TENDER / BAMU / 2024-25
Open Tender
Miscellaneous Works
Percentage
365 days
chh Sambhjinagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,400
₹90,000
19 Aug 2025
6 Sept 2024
7 Oct 2024
6 Sept 2024
5 Oct 2024
6 Sept 2024
Amount
Annual Rate Contract Tender for OFC Networking and Equipment’s
6 Core Cable Single mode Corrugated Steel Tape Armour Outer Sheath, Water BlockingGel , Multi/Uni loose tube, outdoor Directly Buried, 9/125 micron, Meter marking Per Meter, OFC cable with minimum 10 Years of life by OEM
12 Core Cable Single mode Corrugated Steel Tape Armour Outer Sheath, Water BlockingGel , Multi/Uni loose tube, outdoor Directly Buried, 9/125 micron, Meter marking Per Meter, OFC cable with minimum 10 Years of life by OEM
24 Core Cable Single mode Corrugated Steel Tape Armour Outer Sheath, Water BlockingGel , Multi/Uni loose tube, outdoor Directly Buried, 9/125 micron, Meter marking Per Meter, OFC cable with minimum 10 Years of life by OEM
48 Core Cable Single mode Corrugated Steel Tape Armour Outer Sheath, Water BlockingGel , Multi/Uni loose tube, outdoor Directly Buried, 9/125 micron, Meter marking Per Meter, OFC cable with minimum 10 Years of life by OEM
96 Core Cable Single mode Corrugated Steel Tape Armour Outer Sheath, Water BlockingGel , Multi/Uni loose tube, outdoor Directly Buried, 9/125 micron, Meter marking Per Meter, OFC cable with minimum 10 Years of life by OEM
6 Core Cable Single mode Self-Supporting Metal-Free Aerial, Multi/Uni loose tube outdoor, 9/125 micron, Double sheath protection, Longitudinal water protection, Strain-free fiber OFC cable with minimum 5 Years of life by OEM
12 Core Cable Single mode Self-Supporting Metal-Free Aerial, Multi/Uni loose tube outdoor, 9/125 micron, Double sheath protection, Longitudinal water protection, Strain-free fiber OFC cable with minimum 5 Years of life by OEM
4 Core Cable Single mode outdoor Drop cable, Multi/Uni loose tube, 9/125 micron, Ribbon fiber design, Stainless Steel wire for Aerial installation, ARP for more tensile strength and stiffness, Aramid yarns around central tube OFC cable with minimum 5 Years of life by OEM
6 Core Cable Single mode outdoor Drop cable, Multi/Uni loose tube, 9/125 micron, Ribbon fiber design, Stainless Steel wire for Aerial installation, ARP for more tensile strength and stiffness, Aramid yarns around central tube OFC cable with minimum 5 Years of life by OEM
6 Core Cable Repair and restoration of OFC Breakdown (Underground)-Splicing, OTDR(before & after), junction box/joint enclosure, civil/labor work, digging and filling 3 feet, OFC 10 meter, etc.
12 Core Cable Repair and restoration of OFC Breakdown (Underground)-Splicing, OTDR(before & after), junction box/joint enclosure, civil/labor work, digging and filling 3 feet, OFC 10 meter, etc.
24 Core Cable Repair and restoration of OFC Breakdown (Underground)-Splicing, OTDR(before & after), junction box/joint enclosure, civil/labor work, digging and filling 3 feet, OFC 10 meter, etc.
48 Core Cable Repair and restoration of OFC Breakdown (Underground)-Splicing, OTDR(before & after), junction box/joint enclosure, civil/labor work, digging and filling 3 feet, OFC 50 meter, etc.
96 Core Cable Repair and restoration of OFC Breakdown (Underground)-Splicing, OTDR(before & after), junction box/joint enclosure, civil/labor work, digging and filling 3 feet, OFC 50 meter, etc.
6 Core Cable Repair and restoration of OFC Breakdown (Above ground)-Splicing, OTDR(before & after), LIU, Pigtails, Couplers, OFC 10 meter, SC-SC/SC-LC patch cords, labor work, etc.
12 Core Cable Repair and restoration of OFC Breakdown (Above ground)-Splicing, OTDR(before & after), LIU, Pigtails, Couplers, OFC 10 meter, SC-SC/SC-LC patch cords, labor work, etc.
24 Core Cable Repair and restoration of OFC Breakdown (Above ground)-Splicing, OTDR(before & after), LIU, Pigtails, Couplers, OFC 10 meter, SC-SC/SC-LC patch cords, labor work, etc.
SC-LC 1 Meter 9/125 Micron Single Mode Duplex Fiber Patch Cords with minimum 5 Years of life by OEM
LC-LC 1 Meter 9/125 Micron Single Mode Duplex Fiber Patch Cords with minimum 5 Years of life by OEM
SC-SC 1 Meter 9/125 Micron Single Mode Duplex Fiber Patch Cords with minimum 5 Years of life by OEM
SC-LC 2 Meter 9/125 Micron Single Mode Duplex Fiber Patch Cords with minimum 5 Years of life by OEM
LC-LC 2 Meter 9/125 Micron Single Mode Duplex Fiber Patch Cords with minimum 5 Years of life by OEM
SC-SC 2 Meter 9/125 Micron Single Mode Duplex Fiber Patch Cords with minimum 5 Years of life by OEM
Optical Fiber Pigtails Single Mode, 9/125 Micron, with minimum 5 Years of life by OEM
OFC Couplers
SC-SC Single Mode Simplex
SC-SC Single Mode Duplex
OFC splicing
OTDR Testing with Report
8 way Fiber Patch Panel/LIU Rack Mountable with SC adapter plates
16 way Fiber Patch Panel/LIU Rack Mountable with SC adapter plates
24 way Fiber Patch Panel/LIU Rack Mountable with SC adapter plates
48 way Fiber Patch Panel/LIU Rack Mountable with SC adapter plates
96 way Fiber Patch Panel/LIU Rack Mountable with SC adapter plates
HDPE Pire-40 mm outer/33 mm inner diameter
Coupler for HDPE Pipe
Bangadi Pipe for 40 mm HDPE
6 F Junction Box/Joint Enclosure(Under Ground)
12 F Junction Box/Joint Enclosure(Under Ground)
24 F Junction Box/Joint Enclosure(Under Ground)
48 F Junction Box/Joint Enclosure(Under Ground)
96 F Junction Box/Joint Enclosure(Under Ground)
6 F Fiber Distribution Box /Joint Enclosure (Above Ground)
12 F Fiber Distribution Box /Joint Enclosure (Above Ground)
1 G 1 Way SFP Module/Transreceiver Single Mode LC Long Range
1 G 2 Way SFP Module/Transreceiver Single Mode LC Long Range
24 Port Gigabit + 2 Mini GBIC LAN switches with 3 years of OEM warranty
Fully loaded 9U Rack, 4 Fans, Hardware Packet 10’s pkt, Anchor Bolt Spi. Wall mount A/c Box only to be used in wall mount racks, 1U cable Manager metal including fitting charges with PDU, 15AMP, etc.
New Chamber RCC Round OFC Cable Chambers, Grade: M 25 to M 30 with Round RCC Cable Chamber Cover
Reconstruction of old chambers with Round RCC Cable Chamber Cover
Fiber Cable Route markers (3 feet height cement pillar)
Usb/battery rechargeable Mini 3 in 1 Optical Power Meter with VFL 1mW 5km Visual Fault Locator & Rj45 Tester with small bright LED flashlight
Labor Charges Trenching / digging (Soft and/or Hard and/or Hard rock with blaster) earth and filling – 3 feet
Labor Charges OFC laying charge
Labor Charges HDPE pipe laying charges
R G VENTURES (BID ID -6137903)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .