Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹31.6 L+₹59,069.99 (1.90%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹32.7 L+₹1.7 L (5.51%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
23 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) BAMRAULI
HQ CWE AF BAMRAULI ALLAHABAD-211012
PROVISION OF THREE PHASE SUPPLY TO AF STN DARBHANGA UNDER GE (AF) BIHTA
2021_MES_473552_1
87159/C/E8
Open Tender
Civil Works - Others
Item Rate
182 days
Darbhanga
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) Bihta
₹58,000
Yes
11 Dec 2021
13 Sept 2021
1 Nov 2021
13 Sept 2021
23 Oct 2021
8 Oct 2021
60 days
Amount
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, laying cable etc or for manholes etc not exceeding 10 Sqm area on plan and getting out in soft/loose soil complete.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil, complete.
Removing excavated surplus soil not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables. Note:- Only Punned thickness shall be measured for payment purpose.
Providing, plain cement concrete 1:4:8 type D-2, (using 40 mm graded crushed stone aggregate) as in mass concrete, filling and foundation etc complete all as specified and directed.
Providing, plain cement concrete 1:3:6 type B1, (20mm graded crushed store aggregate) as in mass concrete, filling and foundation etc complete all as specified and directed.
Providing, plain cement concrete 1:2:4 type B1, (20mm graded crushed store aggregate) in copings, and the like including weathering, slightly rounded or chamered angles and throating, including necessary form work complete all as specified and directed.
Material and labour well burnt sub class 'B' bricks laid flat width wise along the length of cable for protection of cable complete all as specified and directed by Engr-in-Charge.
Supply & fixing 80mm dia GI tubing light grade, on poles, under floors, road crossing etc includng all fittings and taking out old unserviceable rusted GI pipe complete all as specified and as directed by Engr-in-Charge.
Supply & fixing 100mm dia GI tubing light grade, on poles, under floors, road crossing etc includng all fittings and taking out old unserviceable rusted GI pipe complete all as specified and as directed by Engr-in-Charge.
Supply & fixing fuse suitable for 11 KV 60 Amps 3 mm complete complete all as specified and as directed by Engr-in-Charge.
Mild steel work as cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge.
Supply, laying, jointing & testing of underground LT cables XLPE insulated, PVC sheathed, Aluminimum conductors, multistranded, armoured heavy duty 1100 Volt grade cross sectional area 150 Sqmm 3.5 core laid in trenches/ducts/along poles/through pipe under road etc with new copper lugs complete all as specified and directed by Engr-in-Charge. Note :- Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule.
Cable jointing kit for 11 KV (earthed) heat shrinkable, outdoor termination joint suitable for cross sectional area 95 Sqmm, 3 core aluminium conductor XLPE Cable including jointing material and accessories complete.
Cable jointing kit for 11 KV (earthed) heat shrinkable, straight through joint suitable for cross sectional area 95 Sqmm, 3 core aluminium conductor XLPE Cable including jointing material and accessories complete.
Material and labour for cable jointing kit suitable for 1.1 KV (Earthed) grade cable suitable for indoor / out door end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 150 Sqmm complete all as specified and as directed by Engr-in-Charge.
Material and labour for Lightning Arrestor complete, HT, 11000 volts, nonlinear type, complete with all fittings, transmission class, discahrge capacity 65 Kilo Amps 10 KV ratings complete all as specified and directed by Engineer-in-Charge.
Material and labour for danger Notice board , HT, 11000 volts , of size 25 Cm X 20 Cm, 1.6 mm thick, mild steel sheet , vitreous, enameled white with letters , figures and conventional skull and bones in signal red colour and fixed with clamps, bolts, nuts of approved size complete all as specified and directed by Engineer-in-Charge.
Supply, installing, connecting and commissioning switch air break gang operated, triple pole, suitable for horizontal / vertical mounting, out door type of 12 insulators, mechanically operated, mounted on insulators and steel frame, with operating mechanism and operating rod of 25mm bore GI pipe heavy grade worked from ground level, with locking arrangements including brass pad locks with key (Make. Godrej/Harrison/Link) for current rating 200 Amp at 11 KV, complete with drop out fuse set, fuse carrier and fuse elements having 100 Amp at 11 KV complete all as specified and directed by Engineer-in-Charge.
Supply and fix disc type insulator, porcelain, vitreous, whigte, brown or green 145mm height, and 255 mm dia ball and socket type two in series assembly for tension with tension clamps for conductors, including bolts, nuts and washers working pressure 11000 volts grade complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5metre below the ground level connected to GI strip 25x4 mm by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 40 mm bore medium grade for protection of earth strip, and GI pipe 20 mm bore medium grade for watering, PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways, CI frame and charcoal dust and common salt, all as shown in electrical plate No. 3 of MES SSR part-I and making test point as specified including excavation & earth work in any type of soil and connecting the earthing to an earthing point/equipment as specified and directed & testing on completion. NOTES : (i) The concrete pit shall be made in PCC 1:3:6 type C-1, using 20mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be adjusted through deviation order (iii) Items includes cost of 7.5 metre earth lead strip. Any variation in length shall be adjusted through deviation order. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides
Supply, installation, testing and commissioning of step down transformer of capacity 160 KVA, outdoor type complete with standard fitting and accessories, HT 11KV, 3 Phase, LT 433 volt, 3 phase 4 wire with off load tap changer on primary side to carry secondary voltage ± 7½ % with tappings at every 2½ % all as per IS 1180-2014 level 1, copper wound, oil cooling with fins vector group : DYN 11, including initial oil fitting complete all as specified including the following accessories :- (a) Three numbers porcelain bushing HT, 11KV with brass bushing rods, nuts, bolts and washers etc inside cable end box. (b) One cable box LT side consisting of 4 Nos porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT under ground cable. (c) Oil conservator with filler type drain valve and oil level gauge. (d) Dheydrating breather with fast fill of dehydrating agent. (e) Explosion vents (f) Thermometer pocket on tank cover. (g) One number 100mm dia, dial type thermometer vapour pressure type having range 0 to 120 degree centigrade. (h) Rating plate and terminal marking plate. (j) Earthing arrangement. (k) Oil drain filter valve. (l) Oil drain valve. (m) Lifting hook. (n) Oil conservator with filling hole and cap. (o) Air relief valve plug. (p) Four plate solid cast steel detachable rollers. (q) Earth bushing for neutral outside the cable box for providing independent earthing for neutral. (r) Suitable size of channel on foundation for fixing the transformer with joint and stopper. (s) PCC plateform complete all as shown on drawing No CEAF/TD/EM/03 SHEET 1/1 Dated 31.10.1994 revision date 09.06.2003 excluding XPM welded mesh fencing and doors including 75 x 40 mm channel.
M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS
M/S Akash Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .