Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 CrAccepted-AOC 858 SECTOR 23 127021 2021R109 | BHIWANI | HARYANA | 127021 | ₹8.7 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹8.9 Cr+₹19.0 L (2.19%)Rejected-AOC HOUSE NO 2404 GROUND FLOOR SECTOR 13 HUDA BHIWANI TEHSIL AND DISTRICT BHIWANI 2025R24022 | BHIWANI | BHIWANI | HARYANA | ₹8.9 Cr+₹19.0 L (2.19%) | L2 | Rejected-AOC Highest |
| 3 | L3₹9.2 Cr+₹47.8 L (5.50%)Rejected-AOC H NO 1100 SECTOR 3 124001 | ROHTAK | HARYANA | 124001 | ₹9.2 Cr+₹47.8 L (5.50%) | L3 | Rejected-AOC Highest |
| 4 | L4₹9.3 Cr+₹55.7 L (6.41%)Rejected-AOC NEAR SHIV MANDIR VILLAGE RAJPURA KHARKARI TEHSIL AND DISTRICT BHIWANI 127031 | BHIWANI | HARYANA | 127031 | ₹9.3 Cr+₹55.7 L (6.41%) | L4 | Rejected-AOC Highest |
| 5 | L5₹9.8 Cr+₹1.1 Cr (12.8%)Rejected-AOC NEAR GAURAV ICE FACTORY LOHARU ROAD CHARKHI DADRI 127306 | CHARKI DADRI | HARYANA | 127306 | ₹9.8 Cr+₹1.1 Cr (12.8%) | L5 | Rejected-AOC Highest |
| Sl No | Description | Qty | Unit | MAHA LAXMI CONSTRUCTION COMPANY L6 | M/S SHREE BALAJI BUILDERS L3 | Kulbir Singh Contractor L2 | Ravinder Sharma Contractor L4 | VIKASH BADESRA CONT L5 | M/S JAGVIR SINGH CONRACTOR L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.01 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (400 Sqmm size) | 270 | Per Metre | 81,00,000 ₹81,00,000 | 68,40,450 ₹68,40,450 | 70,20,000 ₹70,20,000 | 32,40,000 ₹32,40,000 | 29,70,000 ₹29,70,000 Lowest | 62,10,000 ₹62,10,000 |
| 1.02 | Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) cast Iron, class B (IS 1536) complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion etc up to the site of work.
450 mm nominal diameter | 135 | Per Metre | 10,80,000 ₹10,80,000 | 15,30,225 ₹15,30,225 | 13,50,000 ₹13,50,000 | 12,15,000 ₹12,15,000 | 20,25,000 ₹20,25,000 | 6,75,000 ₹6,75,000 Lowest |
| 1.03 | Providing, fixing, lointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site.
450 mm nominal diameter | 18 | No. | 10,80,000 ₹10,80,000 | 3,12,030 ₹3,12,030 | 2,70,000 ₹2,70,000 | 3,06,000 ₹3,06,000 | 90,000 ₹90,000 Lowest | 6,30,000 ₹6,30,000 |
| 1.04 | Providing, fixing, lointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site.
400 mm nominal diameter | 18 | No. | 9,00,000 ₹9,00,000 | 2,50,830 ₹2,50,830 | 2,34,000 ₹2,34,000 | 2,50,200 ₹2,50,200 | 63,000 ₹63,000 Lowest | 5,40,000 ₹5,40,000 |
| 1.05 | Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) cast Iron, class B (IS 1536) complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion etc up to the site of work.
400 mm nominal diameter | 27 | Per Metre | 2,16,000 ₹2,16,000 | 2,68,245 ₹2,68,245 | 2,10,600 ₹2,10,600 | 2,29,500 ₹2,29,500 | 67,500 ₹67,500 Lowest | 1,21,500 ₹1,21,500 |
| 1.06 | Providing and fixing of CI sluice valves conform to IS1 4846 / DIN 3352,with length over flanges as per PDorALT1ofIS14846 corresponding to BSEN – 558/ISO5752 Basic Series 3 and15 respectively including labour, material, joints. Make:IVC / VAG / Kirloskar complete in all respect as per specifications mentioned in DNIT (750 mm i/d) | 2 | Job | 22,00,000 ₹22,00,000 | 18,70,000 ₹18,70,000 | 14,40,000 ₹14,40,000 | 12,00,000 ₹12,00,000 Lowest | 47,80,000 ₹47,80,000 | 18,00,000 ₹18,00,000 |
| 1.07 | RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked
`
16900 LPM x 60.00 M (For R/W P/Stn.) | 9 | Each | 2,79,00,000 ₹2,79,00,000 | 2,73,15,000 ₹2,73,15,000 | 2,29,50,000 ₹2,29,50,000 | 2,63,25,000 ₹2,63,25,000 | 3,15,00,000 ₹3,15,00,000 | 2,13,93,000 ₹2,13,93,000 Lowest |
| 1.08 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 375 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For R/W P/Stn.) | 9 | No. | 67,50,000 ₹67,50,000 | 1,02,15,000 ₹1,02,15,000 | 90,00,000 ₹90,00,000 | 92,25,000 ₹92,25,000 | 99,00,000 ₹99,00,000 | 45,00,000 ₹45,00,000 Lowest |
| 1.09 | `VCB Panel: Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/Manually closing breaker suitable for use on 11kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as reqd. (1 IC plus 2 OG)
a). VCB, 11KV, 630Amp, 50KA.
b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy and 100 VA burden -3 no’s.
c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class 0.2.
d). Control panel- Cubicle type control panel suitable for floor mounting made out of 1.63 mm CR sheet duly powder coated and with following relays.
e). Microprocessor based numerical relay for O/L, E/F and SC Protection suitable for above.
f). Master trip relay -2 no’s.
g). Indicator type Annunciator panel with buzzer.
h). Digital Volt Meter- 0-11 KV.
i). Digital Amp Meter- 0-100 Amp.
j). RYB/ Trip/Closing/Spring charged indicator lamp.
k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz Relay Alarm And Trip Auxiliary relay.
l). TNC Switch for Operation.
m). Multifunction Meter EM6400NG.
n). TCS Relay for Safe
` | 3 | No. | 75,00,000 ₹75,00,000 | 34,05,000 ₹34,05,000 | 32,40,000 ₹32,40,000 Lowest | 34,50,000 ₹34,50,000 | 42,00,000 ₹42,00,000 | 54,00,000 ₹54,00,000 |
| 1.10 | Credit of existing outlived pump sets. (At R/W P/Stn.)
At R/W P/Stn. (R/W pump) - 3 no. (240 HP) | 1 | Job | -1,00,000 ₹-1,00,000 | -2,85,000 ₹-2,85,000 | -1,50,000 ₹-1,50,000 | -2,50,000 ₹-2,50,000 | -3,00,000 ₹-3,00,000 | -1,50,000 ₹-1,50,000 |
Tender Value
₹10.8 Cr
EMD Value
₹21.7 L
Closing Date
20 May 2026, 11:00 amClosed
KAPIL DEV
Bhiwani PHED No. 2
AUGMENTATION OF W/S SCHEME BHIWANI TOWN
2026_HRY_517967_1
20265C418418 DE08 4C8A A25F 7C24FC2CEF11554PUH
Open Tender
Civil Works
Works
270 days
Bhiwani
CONSTRUCTION OF RAW WATER PUMPING STATION ETC
2 documents required · 2 mandatory
₹20,000
₹21.7 L
Yes
20 Aug 2026
27 Apr 2026
20 May 2026
27 Apr 2026
20 May 2026
27 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | H.S.R. Item | 1 | Nos | 3,63,11,504.02 | ₹3,63,11,504.02 |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
BOQ_596842.xls
BOQ • 0.35 MB
777956Z153037.pdf
Additional Documents • 0.48 MB
OT0153037.pdf
Other Document • 9.76 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .