Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC PO CHANDL PS BISHNUPUR DIST SOUTH 24 PGS PIN 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹48.4 L+₹43,457.78 (0.91%)Rejected-Finance TIORKHALI MAHESHGANJ NADIA | NADIA | NADIA | WEST BENGAL | 790804 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹50.1 L+₹2.1 L (4.42%)Rejected-Finance 38 BAGUIATI ROAD KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹5.0 L−₹42.9 L (89.6%)Rejected-Finance ROOM NO B 111 PART III GANESH MURTINAGAR CAPT PRAKASH PETHE MARG CUFFEPRADE CALABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹50.1 L+₹2.1 L (4.46%)Rejected-Finance P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹43.6 L
EMD Value
₹87,280
Closing Date
15 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
ADDN/ALTN OF BLDG NO P-30 (ZONAL CONTROL CENTRE), STRENGTHENING OF FLOOR AT UNIT IT CELL, GAZEBO AND ALUMINIUM WORK IN BLDG NO. P-19 AND PROVN OF SHED FOR RNC GEN SET NEAR BLDG NO. P-19 OF CERTAIN UNIT AND ADD/ALTN TO ROOM NO 310 OF CERTAIN UNIT OF H
2022_MES_530278_3
8855/E8
Open Tender
Civil Works
Item Rate
210 days
GE(FW) Kolkata
Ref tender documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹87,280
13 Sept 2022
6 Aug 2022
16 Aug 2022
6 Aug 2022
15 Aug 2022
7 Aug 2022
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Dismantling stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris complete all as specified and as directed.
M&L for brushing neat cement slurry with 2.75 Kg of cement per Sqm on roof complete all as specified and directed.
M&L for Providing Cement Concrete, Type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding mixed with water proofing compound and the concrete surfaces is to be finished even and fair (without using extra cement) complete all as directed by Engineer - in - charge . (NOTE: WPC Shall be measured & paid separately)
M&L 15 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm and allowing to dry till tack free. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished (reinforced with non-woven polyster) matt membrane having mineral top, fixed with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Sealing of all angles & abutments upstands with extra care to ensure perfect bondage. Sealing of edges well into grooves & prtect the seal with a polysulphide/polyurethane sealant.
Supply only liquid Water Proofing Compound, conforming to IS and as approved, complete all as specified.
S&F heat resistant roof/terrace ceramic tiles, of size 300 mm X 300 mm of minimum 9.5 mm thickness, white coloured with mineral composition for reflective thermal insulation with solar reflective index (SRI) > 0.90 on roof/terrace, laid over and including 20 mm thick screed bed in cement mortar 1:4 mixed with liquid water proofing compound @ 200 ml/50 kg bag of cement, applying cement slurry and scratching the screed bed for proper fixing of tiles, laying the tiles with 4-6 mm spacers, curing the tiles for 48 hours and subsequently filling and grouting the joints with mix of white cement & marble powder/grout powder in the ratio 1:1 including providing skirting upto 150 mm height along the parapet walls in the same manner but at an angle of 45 degree over screed bed in cement mortar 1:3 complete all as specified and as directed. (MAKE: JOHNSON, Model: Endura Cool Roof tiles / ORIENT BELL, Model: Cool White or similar model in other ceramic tiles makes specified in tender) (Note: Waterproofing compound shall be measured & paid separately)”
M & L for cutting Grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type-B1 as required complete all as specified and directed.
M&L bituminous gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces, all as specified and directed.
M&L for plain cement concrete (1:2:4) type B1 using 20 mm graded aggregates in roof kerbs or mud stops, rounded or chamfered on edges including formwork complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B1 usi ng 20 mm graded aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones , bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed.
Demolition of brick work or stone boulder masonry built in cement mortar including all quaries, arches pillars etc and removing off the site complete all as specified and directed.
M&L for brickwork with fly-ash old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M& L for brickwork with fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
M&L for dubbing out cement plaster (1:4), average 10 mm thick on irregular faces of walls (when specially ordered in writing) complete all as a specified and as directed
M&L for rendering 15 mm thick to fair faces of brick work / concrete surface in cement mortor (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M&L 10 mm thick rendering on fair faces of concrete surfaces in cement mortar (1:3) as on ceiling finishing concrete surfaces even and smooth without using extra cement complete all as specified and directed
M & L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (@ 200 ml per bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only".
M&L for preparation of new plastered surfaces of walls and applying 2 mm thick wall putty duly finished to a smooth surface and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceilings and applying 2 mm thick wall putty duly finished to a smooth surface and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L for complete removal of existing treatment on walls and applying 2 mm thick wall putty duly finished to a smooth surface and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls and applying one coat of oil bound distemper complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceillings and applying one coat of oil bound distemper complete all as specified and directed.
M&L for preparing newly plastered surfaces of walls and applying Two Coats of weather proof exterior emulsion paint over a coat of alkali resistant primer over and including 2 mm thick exterior wall putty complete all as specified and as directed.
M&L for complete removal of existing treatment of walls and applying Two Coats of weather proof exterior emulsion paint over a coat of alkali resistant primer over and including 2 mm thick exterior wall putty complete all as specified and as directed.
M&L for preparation of old decorated surfaces of walls and applying two coats of white wash complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceillings and applying two coats of white wash complete all as specified and directed.
Taking down chowkats of frames with shutters (without taking off shutters, from the frames) not exceeding 1.50 Sqm each and removing off the site complete all as specified and directed.
Taking down chowkats of frames with shutters (without taking off shutters, from the frames) exc 1.50 Sqm but n exc 4.0 sqm each and removing off the site complete all as specified and directed.
Taking down shutters any description exc 1.0 but not exc. 2.0 sqm each and removing to store/from site complete all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer composite) solid door/window/ceosetory windows & other frames/chowkhat of size 45x70mm comprising of virgin PVC polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 grams) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N(Edge), minimum compressive strength of 58N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with mild steel hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. (Note: MS hold fast/lugs or SS dash fasteners shall be paid for seperately. For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made)
S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as specified and directed. (Note: Stainless steel butt hinges and necessary S.S screws shall be paid separately)
Supplying and installing uPVC sliding windows / doors made out of lead free green profiles having a worldwide presence with a GREENLINE mark having two tracks and two sashes (shutters) with frame dimension of 58 mm x 49 mm and sash dimension of 61 mm x 47 mm x 37 mm with corners fusion welded, fully reinforced with galvanised steel of 1.2 mm. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised local fabrication partner. The windows must be installed complete with all kinds of iron mongery in 1st quality (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of silicon sealant from inside and outside of Dowcorning / GE or equivalent. The profiles should be of an international brand giving factories in multiple countries and having a warranty of 20 years. The profiles should confirm to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and also scaffolding if required for fixing is deemed to include in the rate quoted. (Make: Kommerling/Fenesta or equivalent make as approved by GE)
S&F 4.8 mm thick sheet glass, obscured or frosted on one side, area in squares exc 0.5 sqm in each pane and fixed to uPVC joinery complete all as specified and as directed.
S&F Factory made solid PVC door frame (chowkhat) of size 100 mm x 45mm made out of 5mm thick single side prelam PVC sheet, frame reinforced with MS square tube of size 40mm x 20mm of 19 guage throughout the frame, fixed in opening as per specification & drg as per manufacturer instructions complete all as specified and directed.
S&F 28-30mm thick factory made solid PVC moulded door shutter, with 2, 4, or 6 raised panel design with 2mm thick Moulded prelam PVC Sheet on the front face & 2mm plain prelam PVC sheet on back face, complete all as specified against clause 8B 4.1 of SSR Pt-ll and all as shown in product drawing on ser page No. 161 of SSR Pt-ll (2020) complete all as specified and directed.
S&F stainless steel hinges of 100 mm size, complete all as specified and directed. (Make: PRAYAG, Cat No: HG2414 or equivalent model in other approved makes specified in tender)
S&F stainless steel handle of size 200mm, complete all as specified and directed. (Make: PRAYAG, Cat No: DHL2200 or equivalent model in other approved makes specified in tender)
S&F stainless steel tower bolt of size 200mm, complete all as specified and directed. (Make: PRAYAG, Cat No: TBR 2200 or equivalent model in other approved makes specified in tender)
S&F stainless steel Aldrop bolt of size 300mm, complete all as specified and directed. (Make: PRAYAG, Cat No: LD 1212 or equivalent model in other approved makes specified in tender)
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all specified and directed.
S&F 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all specified and directed.
S&F 150mm extruded aluminium handles, fabricated type, anodised complete all specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overal length of cover plate 150 mm complete all as specified and directed.
S&F Floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, fixed in floor, overal length of cover plate 150 mm complete all as specified and directed.
Disconnecting exiting water storage Tank of capacity exceeding 500 litres but not exceeding 1000 liters for cleaning of water tank, removing of mud, sludge etc and flushing with chlorine water including supply and fixing of any damaged accessories for water Tank and re-connecting and refixing all connections complete all as specified and directed.
Supply, hoisting and fixing in proper position ISI marked multi-layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), of capacity 1000 litres and providing necessary connections including dismantling old tanks and removal from site complete all as specified and as directed.
S&F in repair 25 mm bore Ball brass valves, high pressure, with HDPE float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. (MAKE : PRAYAG, Cat No. B-153 or equivalent model in JEXON / POLYTUF / SHAKTI)
Taking up or down steel water tubing 15 mm bore incl connections and removal from site complete all as specified and directed.
-ditto all as per item No 50 here-in-before but 20 mm bore
S&F tubes 15mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
-ditto all as per item No 52 here-in-before but 20 mm bore
S&F in repairs gun metal gate or globe valve, with iron wheel head, screwed both ends for iron pipe and fixed for 20 mm bore pipe complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipes, 100 mm bore, jointed in cement mortar and taking out of trenches, complete all as specified and directed.
S&F Cast iron (sand cast) soil, waste and vent pipes 100 mm bore of any length with or without ears with cement joints all as specified laid in trenches or in floors complete all as specified and directed.
S&F CI bends for 100mm pipe (any radius) diminishing piece or tapers (large bore measured) complete all as specified and directed.
S&F CI branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parellel branches, for 100mm dia pipe complete all as specified and directed.
S&F CI branch pieces, with oval access door, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parellel branches, for 100mm dia pipe complete all as specified and directed.
S&F 100 mm cast iron sanitary connection socket to fit WC outlet complete all as specified and directed.
S&F 100 mm dia CI floor/nahani trap, with grating including jointing to waste pipe, fixed in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregates complete all as specified and directed.
S&F Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back or Angle Back Type), making good disturbed Surfaces in Cement Mortar 1:3, providing CP waste coupling and PVC waste pipe and connected Items, complete all as specified and directed. (Make of WHB : PARRYWARE, Cat No. C0406 / HINDWARE, Cat No. 10010 / JAQUAR, Cat No. CNS-WHT-801 / CERA, Cat No: S2040141) (Make of Waste Pipe: PRAYAG, Cat No: 327 or equivalent make as spproved by GE) (Make of Waste Coupling: PRAYAG, Cat No: BEA-10 / JAQUAR. Cat No: ALD-705/ CERA, Cat No: F8050101)
S&F Vitreous china, white, full stall urinal flat back with grating and union for discharge pipe (excl flush pipe and flushing cistern and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and Union for discharge pipe complete all as specified and directed. (Make of Urinal : CERA, Model: CAPRIANA / HINDWARE, Model: FLAT BACK LARGE / Jaquar, Cat No: URS-WHT-13261/PARRYWAYR, Model: New Magnum)
S&F in repair CP waste coupling for Urinal Pot complete all as specified and directed. (Make PARRYWARE, Cat No: T9954A1 / PRAYAG, Cat No: BEA-09 or equivalent model as approved by GE)
S&F 32 mm bore PVC urinal waste pipe, 800 mm long complete all as specified and directed. (Make: PRAYAG, Cat No: 3271 or equivalent make as approved by GE)
S&F in repair Low density polythelene pipe connection, comprising of 15 mm dia 450 mm long having PTMT union at each end of connection to each of pillar tap/cistern/stop cock/urinal etc. at one end, stop cock at other end complete. (MAKE : PRAYAG, Cat No. 323 / POLYTUF, Cat No. 4003 / ESS ESS, Cat No: B2CH118 or equivalent model in SHAKTI / JEXON)
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete al as specified and directed. (MAKE: HINDWARE, Cat No: F880010 / JAQUAR, Cat No: ACN-1171N / PARRYWARE, Cat No: T6009A1 / PRAYAG, Cat No: BEA-51 / CERA, Cat No: F5001114)
S&F toilet paper holder, surface type with flap complete all as specified and directed. (Make : JAQUAR, Cat No : ACN-1153N / CERA, Cat No: F5007110 / PRAYAG, Cat No: BA-08 / ESS ESS, Cat No: AC-506 / HINDWARE, Cat No: F880003 / PARRYWARE, Cat No: T6514A1)
S&F in repair angle valve, 15 mm bore, cast copper alloy, chromium plated fancy type, concealed type with wall flange fixed to iron pipe complete all as specified and directed. (Make : PARRYWARE, Cat No: G4807A1 / JAQUAR, Cat No: FUS-29053 / CERA, Cat No: F1015361 / ASIAN PAINTS, ALAC101 / HINDWARE, Cat No: F360006 / PRAYAG, Cat No: 9010)
S&F chromium plated Hand shower (health faucet), ABS body with 1.2 metre long flexible tube in chrome finish with wall hook complete all as specified and directed. (MAKE : JAQUAR, Cat No : ALD-CHR-593/ CERA, Cat No: F8030401AB / ASIAN PAINTS, Cat No: C-232N / HINDWARE, Cat No: F160013 / PARRYWARE, Cat No: E8352A1)
S&F in repair self closing taps, cast copper alloy, chromium plated, screwed for iron pipe and fixed complete all as specified and directed. (Make : JAQUAR, Cat No: PRS-031 / CERA, Cat No: F9020101/ PRAYAG, Cat No: BSC-02 / PARRYWARE, Cat No: G2013A1/ HINDWARE, Cat No: F310014)
S&F Tubular towel rail, 20mm dia, 600 mm long, brass chromium plated, fixed with brass screws complete all as specified and directed. (MAKE : JAQUAR, Cat No : ACN-1111SM / PARRYWARE, Cat No : T6401A1 / / CERA, Cat No: F5004103 / HINDWARE, Cat No: F880005 / PRAYAG, Cat No: BA-20)
S&F in repair self closing urinal flush valve, cast copper alloy, chromium plated, screwed for iron pipe and fixed complete all as specified and directed. (Make : HINDWARE, Cat No: F310016 / PARRYWARE, Cat No: G2007A1 / PRAYAG, Cat No: BSC-10 / CERA, Cat No: F9020201 / JAQUAR, Cat No: PRS-077)
S&F in repair Chromium plated brass Bib cock with wall flange, fancy type, long body, fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: FUS-29037 / CERA, Cat No: F1015151/ ASIAN PAINTS, Cat No: ALBC101 / PRAYAG, Cat No: 9306-N/HINDWARE, CAT No: F360004 /PARRYWARE, Model: CLARET)
S&F soap dish, chromium plated body complete all as specified and directed. (Make: PRAYAG, Cat No: BA-45 / CERA, Cat No: F5003106 / ESS ESS, Cat No : AC-503B / PARRYWARE, Cat No: T6902A1)
S&F in repair vitreous china floor mounted coupled closet (Pedestal pattern) white including low level vitreous china valveless syphonic action type flushing cistern with inlet ball valve float, push button, flush pipe incl bracket, P/S trap, PVC white soft close seat cover and connecting fittings complete all as specified and directed. (Make :CERA, Model : CLAIR DELUXE / PARRYWARE, Model: CASCADE NXT / JAQUAR, Model: FONTE / HINDWARE, Model: CONSTELLATION PREMIUM)
S&F stainless steel round floor trap 102 mm dia with waste hole complete all as specified and directed. (Make : PRAYAG, Cat No: FT-04 or equivalent make as approved by GE)
Dismantling wrought iron or mild steel work of any description in rafters, purlins and wind ties etc complete all as specified and directed.
Dismantling of plain corrugated steel sheeting any gauge, thickness, including nainital or similar pattern roof covering & removing off the site complete all as specified and directed.
M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165, complete all as specified and directed.
M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165, framed and hung as gates, including pintle hinges, stops, hand made sliding bolts etc complete all as specified and directed.
M&L for Mild steel hand rails, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165 complete . (NOTE: Measurement shall be taken for the ms flat only. Quoted rate is deemed to include for the cost of securing bolts etc)
M&L for Expanded metal, cut to length, bent to shape required and tying with and including anealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight exc 4 Kg per sqm complete all as specified and directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
M&L for pre-painted, galvalume aluminium zinc coating GI based plain steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
S&F 0.71 mm thick plain aluminium sheeting alloy 31000 H4 as in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) etc complete all as specified and directed. .
M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces not exc. 10 cm width or girth including preparation of surfaces complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of Red oxide, zinc chrome primer to new steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
M&L preparation of old painted steel surface and applying one coat of synthetic enamelled paint of any description, over 10cm in width or girth, not otherwise described for complete all as specified and directed.
M&L preparation of old painted wooden surface and applying one coat of synthetic enamelled paint of any description, over 10cm in width or girth, not otherwise described for complete all as specified and directed.
M&L 18-20mm thick granite slab in window cills, cooking platform etc and like set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of stone slab, laid over and including screed bed 20 mm thick in cement mortar 1:4 complete all as specified and as directed.
Providing edge moulding to 18-20mm thick granite stone of counters, vanities etc including machine polishing to edge to give high gloss finish complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 150 mm thickness (above or below groud level) complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type 'C-2' (using 40mm graded crushed stone aggregate) as in floor, plinth protection etc, laid in alternate bays, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L Non Skid joint free coloured digital tiles 8-9 mm thick, area of each tiles exc 0.18 sqm but n.exc 0.38sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and incl 15mm thick screed bedding in cement mortar 1:4 complete all as a specified and as directed
-ditto- but non-skid tiles in skirting, fixed over and incl 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
M&L Non Skid joint free coloured digital tiles 7-8mm thick area of each tiles exc 0.06 Sqm but n. exc 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and incl 15mm thick screed bedding in cement mortar 1:4 complete all as a specified and as directed
M&L coloured glazed ceramic tiles in vertical surfaces 450X300X7-8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match, fixed over and incl 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L Vitrified ceramic coloured (light shade) tiles, double charged, 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but not exc 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade laid over and incl screed bed 15mm thick cement mortar 1:4 complete all as a specified and as directed
-ditto- but light couloured double charged vitrified tiles in skirting, fixed over and incl 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
M&L Vitrified ceramic coloured (dark shade) tiles, double charged, 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but not exc 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade laid over and incl screed bed 15mm thick cement mortar 1:4 complete all as a specified and as directed
-ditto- but dark coloured double charged vitrified tiles in skirting, fixed over and incl 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
Supply and Fixing PVC solid wall lining consisting of 5 mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per manufacturer’s specification and instruction and as directed.
Supply and Fixing 5mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing.
M&L for Providing Cement Concrete, Type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in sub base of floor etc complete all as specified and directed.
M & L for heavy duty ceramic floor tiles of size 300 x 300 x10mm thick in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed. (MAKE : JOHNSON, Model : Endura or equivalent product in other makes listed in the tender)
S&F in position, at or near ground level, factory made precast cement concrete kerb stone blocks, in M-25 grade cement concrete, fixed to the required line, level and curvature, jointed in cement mortar 1:3, including making joints with or without grooves (thickness of joints, except at sharp curves shall not be more than 5 mm) including making drainage opening wherever required complete all as specified and directed.
S&F Suspended metal grid Ceiling System with mineral fibre acoustic tiles as per following specifications:- a) Ceiling Tiles:- Mineral fibre acoustic tile of 16mm thickness having sand textured finish with acoustical punchers, bevelled tegular edge and 8mm drop in module size of 600 x 600mm. Tiles shall have humidity reistance (RH) of 99%, NRC 0.50 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 33db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of class 0/1 as per BS 476 Part 6/7 and Class A as per ASTM E84. b) Metal Grid:- The grid system shall be 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. contd....
Item No. 111.01 (Contd....) All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. The ceiling grid sections shall be fixed to ceiling with 6 mm dia GI hangers upto required length by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5mm dia 40 mm long. (MAKE OF CEILING GRID : ARMSTRONG, Model: SUPRAFINE 38 or equivalent in GYPROC / USG BORAL / UNISTEEL MAKE OF CEILING TILES: ARMSTRONG, Model: DUNE or equivalent item in GYPROC / USG BORAL / U TONE)
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with 1.38 kg of cement per sq. metre prior to laying of top layer of PCC/screed bed complete all as specified and directed.
S&F powder coated (medium thickness of powder coating 50 micron) aluminium frame for door, windows, partitions and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium doors shutters, aluminium section weighing 0.55 Kg/metre including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc complete all as specified and directed.
S&F 25 micron sun control film on glass reflective type, best quality, sticked to glass panes as per instructions of manufacturers, complete all as specified and as directed. (Make : Garware or equivalent make as approved by GE)
M&L for 18/19mm thick block board, grade-1quality, exterior grade commercial type, fixed to screw to aluminium frame works complete all as specified and directed.
M&L for 0.9 mm thick decorative laminate type-1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instruction over ply wood/block board complete all as specified and as directed.
S&F Door closer hydraulically regulated, designation No. 3, universal type, aluminium (die cast) body, suitable for door shutters of 851 to 1000 mm in width & weight between 61 to 80 kg complete all as specified and directed.
M&L for Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as neL W Cessary, gusset plates, riveting etc. n. exc 10 kg each brackets, conforming to Fe-290 Gde E-165 (brackets over 10 Kg each to be measured under 'structural steel) complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
M&L for excavating in post holes (or similar holes) each not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earh around in layers not exceeding 25 cm for soft/loose soil complete all as specied and directed.
M&L for plain cement concrete (1:2:4) type B2 (using 40 mm graded aggregates) in foundation filling and mass concrete complete all as specified and directed.
M&L for second class hardwood timber in scantling clean sawn complete all as specified and directed.
S&F 12mm thick plywood grade BWR type BB fixed with screws to timber or steel frame work complete all as specified and directed.
SCHEDULE 'A' PART-II (ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets etc excluding light fitting for reuse or removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and incl PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured seperately. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No 125 here-in-before but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 125 here-in-before but for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 125 above but using 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
S & F Modular Switch 1 way, 6 Amps, 1 module complete all as specified and directed.
S & F Modular Switch 1 way, 16 Amps, 1 module complete all as specified and directed.
S & F Modular Socket 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S & F Modular Socket 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S & F Modular Fan step regulator, 120 watt, 2 module complete all as specified and directed.
S & F Modular Bell push 6 Amps, 1 module complete all as specified and directed.
S & F Modular Blank plate, 1 module complete all as specified and directed.
S&F Modular White cover plate with frame 3 module complete all as specified and directed.
S&F Modular White cover plate with frame 4 module complete all as specified and directed.
S&F Modular White cover plate with frame 6 module complete all as specified and directed.
S&F Modular White cover plate with frame 8 module complete all as specified and directed.
S&F Modular White cover plate with frame 12 module complete all as specified and directed.
S & F Modular type Metal Flush box 3 module complete all as specified and directed.
S & F Modular type Metal Flush box 4 module complete all as specified and directed.
S & F Modular type Metal Flush box 6 module complete all as specified and directed.
S & F Modular type Metal Flush box 8 module complete all as specified and directed.
S & F Modular type Metal Flush box 12 module complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/bakelite, three terminals complete all as specified and directed.
S&F Call bell, musical type, AC 230/240 Volts, single pole complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate body with back plate suitable for batten/pendant fittings or to be mounted on walls complete all as specified and directed.
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
S&F in repairs recess mounted LED luminaire, of size 600 mm x 600 mm, in powder coated CRCA housing, having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 36 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
Taking down of existing exhaust fan, 300mm-380 mm sweep from any height, opening the fan, removing the damaged coil and rewinding the coil with suitable gauge of copper wire as per requirement including oiling, greasing and replacement of unserviceable accessories such as capacitor, connector, bearing etc, re-assembling and fixing in existing location with PVC insulated sheathed round flexible wire with multi stranded copper conductor of size 0.50 sqmm 3 core, 1100 volts grade from ceiling rose/connector to fan and testing complete all as specified and directed.
Taking down of existing ceiling fan, 1200/1400 mm sweep from any height, opening the fan, removing the damaged coil and rewinding the coil with suitable gauge of copper wire as per requirement including oiling, greasing and replacement of unserviceable accessories such as capacitor, connector, bearing etc, re-assembling and fixing in existing location with PVC insulated sheathed round flexible wire with multi stranded copper conductor of size 0.50 sqmm 3 core, 1100 volts grade from ceiling rose/connector to fan and testing complete all as specified and directed.
Taking down of existing ceiling fan, 1200/1400 mm sweep from any height, complete with blades, down rod etc, painting the fan with one coat of synthetic enamel paint duly spray painted, re-assembling and fixing in existing location with PVC insulated sheathed round flexible wire with multi stranded copper conductor of size 0.50 sqmm 3 core, 1100 volts grade from ceiling rose/connector to fan and testing complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for sub main wiring with 4 runs (P-N) of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm 1100 volts grade along with one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10 sqmm 1100 volts grade as earth continuity conductor drawn through and including adequate size PVC non-metallic concealed conduit complete all as specified and as directed. (NOTE : Five runs of single core 10.0 sqmm cable and one run of PVC conduit shall be measured as one unit)
All as per Srl. Item No. 155 above but with two runs of 6.0 Sqmm cable and one run of 6.0 Sqmm as earth continuity conductor in PVC conduit (NOTE : Three runs of single core 6.0 sqmm cable and one run of PVC conduit shall be measured as one unit)
All as per Srl. Item No. 155 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC conduit (NOTE : Three runs of single core 4.0 sqmm cable and one run of PVC conduit shall be measured as one unit)
All as per Srl. Item No. 155 above but with two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm as earth continuity conductor in PVC conduit (NOTE : Three runs of single core 2.5 sqmm cable and one run of PVC conduit shall be measured as one unit)
M&L for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
S&F DB, VTPN, 4 way, vertical type, IP 43 protection, double door (premium quality) 415 volts with provision for MCCB as incomer and MCB as outgoing and electrically connecting up complete all as specified and directed. (MAKE : LEGRAND, Cat No: 5077 45 / L&T, Cat No. DBVTL004DD / ABB, Cat No: E-SVTDB M 4XT1 /HAGER, Cat No: VYV04DM-P /SCHNEIDER, Cat No: A9HVD04L)
S&F MCCB (premium quality), 4 pole, 100 Amps, 16 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in DB complete all as specified and directed. (MAKE : L&T, Cat No: CM90518OOKO / LEGRAND, Cat No: 420015 / HAGER, Cat No: HDA126U or equivalent model in SCHNEIDER /ABB)
S&F TPN DB, IP 43 protection, double door (premium range), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE : L&T, Cat No. DBTPN004DD / LEGRAND, Cat No: 507670 / SCHNEIDER, Cat No. A9HTND04 / ABB, Cat No: E-SHDB M4 / PANASONIC, Cat No: BQS 304H / HAGER, Cat No: VYT04DH)
S&F SPN DB, IP 43 protection, double door (premium range), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN004DD / LEGRAND, Cat No: 507610 / ABB, Cat No. E-SHC M4 / SCHNEIDER, Cat No. NBKRENSNDD04 / HAGER, Cat No: VYS04D)
S&F Double Door, Sheet Metal Enclosure for DBs (premium range), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN008DD / LEGRAND, Cat No: 507611 /ABB, Cat No. E-SHC M 8 / SCHNEIDER, Cat No. A9HSND08 / HAGER, Cat No: VYS08D)
S&F MCB (premium range), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (premium range), 'C' series, SPN, 40 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (premium range), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (premium range), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F GI tubing medium grade of size 15 mm dia incl painting and making hole for extension of fan hook in high roof ceiling complete all as specified and directed.
S&F MODULAR MCB protected power unit with one 25 Amps socket with 3 pin plug top and including 01 No MCB, DP, and starter 25 Amps ratings with six module plate and flush metal GI box and electrically connected complete all as specified and directed. (MAKE : HAVELLS, Cat No. DHDUCDP0253025 / NORTH WEST, Cat No: ACPU6M-BT or equivalent model in ABB / CRABTREE / HAGER / SCHNEIDER / LEGRAND) (NOTE : Enclosure & MCB shall be same manufacturer. Cost of MCB is deemed to be included in the quoted rate)
-ditto- but MODULAR MCB protected power unit fixed in repairs
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and all as shown in Figure 15A of IS 3043 :1987, including necessary testing complete all as specified and directed.
Supply, installing and testing split type inverter AC, with indoor & outdoor unit complete, single phase 230V, Copper Condenser with cordless remote control with minimum 5 star rating of capacity 1.5 TR including 4 sqmm 3 core flex cable connection from indoor to outdoor unit as per site requirement including necessary masonry work for making good distrubuted surface and match with the existing colour complete all as specified and directed. (MAKE: DAIKIN, Model No: JTKJ Series / CARRIER, Model No: ESTER NXI or equivalent model in LLYOD) NOTES :- Pipes, brackets for connection of outdoor and indoor unit shall be measured and paid seperately)
Supply and laying refrigerant line copper tubing of size 1/2" with clamping on wall surface or concealed with both the ends connection complete all as specified and directed. [Note: Cutting chases and making good of distrubuted surfaces will be measured and paid under seperate item ]
All as per item Ser No 175 here - in - before but of size 1/4 "
S&F foam insulation for copper tubing dia 1/2'' and 1/4'' complete all as specified and directed.
S&F drain pipe 5/8" dia PVC jacketed heavy duty with fixing of clamp complete all as specified and directed.
S&F powder coated MS bracket stand (1 pair set ) for supporting of outdoor units complete all as specified and directed.
Supply and draw wiring with one 4 core 2.5 sqmm PVC insulated copper cable 1100 volts grade multi stranded from indoor to outdoor unit duly connected with copper lugs suitable at site complete all as specified and directed.
SCHEDULE 'A' PART-III (LIGHTNING PROTECTION WORKS) Demolition of PCC of any size/description and in any position complete all as specified and directed.
S&F in repair air termination, single pointed aluminium rod, 12 mm dia and 300 mm long, fixed on GI pipes with earthing strips for earth coductivity to ground complete all as specified and directed. (NOTE: GI pipe & earthing strip shall be measured and paid seperately)
S&F in repair test point terminal block, made of gun metal or phosporous beonze of size 75 mm X 75 mm X 25mm, drilled and screwed including 3 Nos, 8 mm dia and 25 mm long hex screws complete all as specified and directed.
S&F in repair junction box made out of 3 mm thick mild steel CRCA sheet including applying two coats of syntheic enamel paint over a coat of red oxide primer, duly spray painted, of size not less than 20cm X 20cm X 15cm with locking arrangements and provision of earthing strip entry and exit, fixed on walls with GI bolts, nuts and washers (of suitable size) complete all as specified and directed.
S&F in repair aluminium strip 25 mm X 3.15 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground, fixed on 50 mm size porcelain/FRP insulator @ 1.0 m spacing complete all as specified and directed. (Note: Quoted rate is deemed to be inclusive of the cost of insulators)
S&F in repairs GI tubing 50 mm bore, medium grade, laid in trenches/floors or fixed along poles/walls for cable/earth strip protection, fixed with proper size clamps, nuts & bolts or for fixing lightning conductors etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, complte all as specified and directed.
M&L for precast PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in base of eathing strip, set in cement mortar 1:4 complete all as specified and directed.
M&L for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to copper strip 20 X 3 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
SHEIKH ENTERPRISE
MODERN AGENCY
M/S SRINIVASA CONSTRUCTION
UNIVERSAL TRADING CENTRE
dutta and dutta
MS HORIZEN
MUKHERJEE ENTERPRISE
M/S L.R.ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .