Loading…
Loading…
Tender ID
Tender Value
₹17.3 L
EMD Value
₹34,520
Closing Date
17 May 2026, 5:30 pmClosed
- Rajyapal Janendra(DFLT)
ELECTRICAL DIVISIOIN JAGDALPUR
EXTERNAL ELECTRIFICATION WORK FOR RAJIV NAGAR AWAS YOJNA AT MARARPARA, KONDAGAON DISTT- KONDAGAON (C.G.)
190564
NIT No 10 Date 27/02/2026
RESTRICTED TENDER
WORKS
ITEM RATE
3 days
ELECTRICAL DIVISIOIN JAGDALPUR
Required Past Technical Experience: NA
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
7 documents required · 7 mandatory
Chhattisgarh Housing Board (CGHB)
WORKS
- Rajyapal Janendra(DFLT)
RESTRICTED TENDER
ITEM RATE
A B C D
ELECTRICAL DIVISIOIN JAGDALPUR
TENDER SECTION
EXECUTIVE ENGINEER
90
03
No
49
190564
17 May, 2026 5:30:23 PM IST
20 May, 2026 10:30:22 AM IST
8 May, 2026 3:00:43 PM IST
NIT No 10 Date 27/02/2026
EXTERNAL ELECTRIFICATION WORK FOR RAJIV NAGAR AWAS YOJNA AT MARARPARA, KONDAGAON DISTT- KONDAGAON (C.G.)
34520.00 INR
Demand Draft (OFFLINE)
1725509.50
2
19 May, 2026 5:30:00 PM IST
1725509.5
AS PER NIT
AS PER NIT
2000.00 INR
7 documents required · 6 mandatory · 1 optional
₹2,000
₹34,520
17 May 2026
8 May 2026
20 May 2026
8 May 2026
19 May 2026
SCHEDULE OF ITEM OF EXTERNAL ELECTRIFICATION WORK FOR ATAL VIHAR YOJNA (RAJIV NAGAR AWAS) AT MARARPARA KONDAGAON, DIST- KONDAGAON (C.G.)
S. N. Particulars Unit Qty. Rate Amount
01 Supplying and drawing Havells/Polycab/ Finolex (ISI) Make 1x1.5 sqmm size FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) Metre 25.00
02 Supplying, installation, testing and commissioning Philips/ Crompton/ Wipro make 230/250 volts 45 watt LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. Each 34.00
03 Providing and making interconnection in cubical panel between BBC and switchgears with Havells/Polycab/ Finolex (ISI) make 16 sqmm (63 amp) size FRLS PVC insulated copper conductor wire lead of length upto 50cm including providing copper thimbles on both ends as per specification (To be measured separately for each phase/ neutral). Each 30.00
04 Fabrication, supply, installation, testing and commissioning of 450 mm deep cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. sqm 2.70
05 Supply, installation, testing and commissioning of 100 amp (20x5mm) 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. Metre 1.50
06 Providing and fixing ABB/L&T/Havells (ISI) make 63 amp rating and 10KA braking capacity Fixed Thermal Release MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. Each 3.00
07 Supplying and fixing ABB/L&T/Havells (ISI) make 40 amp TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. Each 3.00
08 Supplying and fixing ABB/L&T/Havells (ISI) make 63 amp TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. Each 6.00
09 Providing and fixing ABB/L&T/Havells (ISI) make 60 amp 4 pole, 415/500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. Each 1.00
10 Providing and fixing 50/5 amps rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each 9.00
11 Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each 9.00
12 Providing and fixing penal mounting 0-100 amp digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification Each 3.00
13 Providing and fixing penal mounting 0-500 volt Digital type voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each 3.00
14 Providing and fixing penal mounting selector switch for voltmeter in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each 3.00
15 Providing and fixing penal mounting selector switch for ammeter in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each 3.00
16 Providing and fixing analog type Time switch (timer) in existing panel including connection, testing and commissioning as per specification. Each 1.00
17 Supplying and laying Polycab/Havells/ Universal make 2 x 4 sq. mm size one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) Metre 85.00
18 Supplying and laying Polycab/Havells/ Universal make 4 x 10 sq. mm size one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) Metre 80.00
19 Supplying and laying Polycab/Havells/ Universal make 4 x 16 sq. mm size one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) Metre 40.00
20 Supplying and making end termination with brass compression gland and aluminum lugs for 4 X 10 sq. mm (22 mm) size armoured aluminum conductor power cable of 1.1 KV grade as per specification. . Each 3.00
21 Supplying and making end termination with brass compression gland and aluminum lugs for 4 X 16 sq. mm (22 mm) size armoured aluminum conductor power cable of 1.1 KV grade as per specification. . Each 1.00
22 Supplying and erection of stay set complete (galvanized) With 7/3.15 mm dia G.I. stay wire 19/20mm dia x 1.8 metre long stay rod, anchor plate of size 300mm x 300mm x 6.4 mm, thimble stay clamps, turn buckle (19/20mm x 600mm), strain insulator and specified G.I. stay wire etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as per specification. Each 22.00
23 Supplying and fixing approved make 11 KV glazed porcelain pin insulator with G.I. spindle on existing pole bracket with necessary materials as per specification: Each 21.00
24 Supplying and fixing approved make 11 KV glazed porcelain disc type insulator with tension hardware on existing pole/ support/ cross arm channel as per specification complete: Each 27.00
25 Supplying and erection of angle/channel iron cross arms/ bracket/ other fitting of approved size and shape including drilling of holes for insulator pins, bolts and nuts etc as per specification. kg 2060.00
26 Supply and erection standard Rabbit 6/1/3.35mm dia with calculated aluminium area 52.88 sq.mm, weight 214 kg/ km (100 amps) ACSR (aluminium conductor steel reinforced) confirming to IS 398-1961 of approved make at existing insulator at height upto 14m from ground level including stringing, binding with insulator, jointing wherever required, jumpering, tearing off connection etc complete etc. as per specification including clearing off obstacle if any: Km 0.50
27 Supply and errection of HT over head line with H Beam 152x152 mm 13 meter long 37.1 kg/Mtr Weight single length supports complete with aligning and keeping it in truly verticle position, including digging of required size filling with M15 grade cement concrete of 0.60 mtr. Dia of required depth around the pole including muffing of 0.50 meter from ground level of 45 mm dia with plaster & 02 coat of approved make weather proof paint as per specification with 20 cm thick base foundation refilling the pit including painting of pole with bitumen paint in bottom and one coat of red oxide and two coats of aluminum paint etc. of approved make the depth of foundation shall be 1/6 of the length of pole. Remark :- The pole should be procured from the valid vender list approved by the CSPDCL. Each 2.00
28 Supply and errection of HT over head line with H Beam 152x152 mm 11 meter long 37.1 kg/Mtr Weight single length supports complete with aligning and keeping it in truly verticle position, including digging of required size filling with M15 grade cement concrete of 0.60 mtr. Dia of required depth around the pole including muffing of 0.50 meter from ground level of 45 mm dia with plaster & 02 coat of approved make weather proof paint as per specification with 20 cm thick base foundation refilling the pit including painting of pole with bitumen paint in bottom and one coat of red oxide and two coats of aluminum paint etc. of approved make the depth of foundation shall be 1/6 of the length of pole . Remark :- The pole should be procured from the valid vender list approved by the CSPDCL. Each 7.00
29 Supply and errection of LT over head line with RS joist 175 x 85 or 175 x 90 mm 9 meter long 19.4kg/Mtr Weight. single length supports complete with aligning and keeping it in truly verticle position, including digging of required size filling with M15 grade cement concrete of 0.60 mtr. Dia of required depth around the pole including muffing of 0.50 meter from ground level of 45 mm dia with plaster & 02 coat of approved make weather proof paint as per specification with 20 cm thick base foundation refilling the pit including painting of pole with bitumen paint in bottom and one coat of red oxide and two coats of aluminum paint etc. of approved make the depth of foundation shall be 1/6 of the length of pole. Remark :- The pole should be procured from the valid vender list approved by the CSPDCL. Each 26.00
30 Supplying, Fixing & Testing of 11 KV gang operated air break switch with 3 insulator per phase complete with the operating rod and locking arrangement as required as per specification on existing pole etc. complete (set of three numbers). Remark :- AB switch should be procured from the valid vender list approved by the CSPDCL. Set 4.00
31 Supplying, Fixing & Testing of approved make 11 KV DO fuse set of suitable capacity with necessary materials and fitting etc. complete on existing DP structure of 11 KV HT line complete as per specifications (set of three numbers). Remark :- AB switch should be procured from the valid vender list approved by the CSPDCL. Set 3.00
32 Supplying, Fixing & Testing of approved make lighting arrester suitable for 11 KV line on existing 11 KV DP structure as per specification with necessary material complete. (set of three numbers). Set 3.00
33 Providing and fixing outdoor type pole mounting weather, dust and vermin proof LT distribution box made of 14/16 gauge MS sheet with clamping arrangements, lockable hinged door duly painted on all sides with red oxide, antirust and corrosion treatment, two coats of synthetic enamel paints of approved make and shade . For 100 KVA 11/0.4 KV substation consisting of following fittings 01 no. 60 Amps TP MCCB with neutral link for incoming , 01 set 4 strip aluminium bus bar 200 Amps supported on epoxy insulators , 06 nos. 250 Amps, 415 Volts HRC base with 150 Amp HRC-Fuse for out going feeder and 03 nos for LT interconnection 2 nos. GI earth terminals 1 no. 7 lever Godrej padlock with keys, 01 no. Light point with switch and hoder, with 100 watt lamp . Each 3.00
34 Making of internal connection of over head existing sub station structure consisting of transformer, lighting arrester A B switch D.O. fuses including providing and connection with 05 ACSR conductor, heat shrikage heavy duty PVC sleeves, soldering insulation tape binding etc. complete with all other necessary material complete and ready for charging as per IE rules. Job 3.00
35 Suppling Laying and Testing of Polycab/Havells/ Universal make 150 Sqmm, Single core Armoured XLPE insulated and over all PVC sheathed heavy duty Power cable (confirming to Latest IS ammendment) 1.1 KV grade cable of approved make with aluminium stranded conductor in existing GI pipe/ RCC hume pipe or any other pipe or in air on wall pole etc. with required materials for connection / termination i/c gland and lugs etc. complte as per requirement of works. Mtr. 120.00
36 Providing and fixing earthing arrangement with Tata/Jindal/Surya make 40 mm dia "B" class GI pipe electrode i/c packing of charcoal power and salt as per specification watering pipe 20 mm dia GI with 40 x 20 mm reducer connection etc. complete with refilling the pit as required i/c excavation of pit in all type of soil providing and making brick masonry chamber of suitable size with CI frame and cover funnal etc complete as per IS specification. Job 23.00
37 Providing and fixing 25 x 3 mm GI strip on surface or in recess for connections etc. as required. Mtr. 300.00
38 Details of cost for one meter Polycab/Havells/ Universal make 16 Sqmm single core unarmored cable, 1100 Volt Grade. Mtr. 208.00
39 Supplying, Laying, Testing & Commissioning of XLPE insulated and PVC sheathed heavy duty 3x70 + 1x35 +1x50 Sqmm. Arial bunch power cable confirming to IS-7098/Part-I/88 with latest amendment, 1.1 KV grade unarmoured cable of approved make with aluminium solid/stranded concuctor. The cable shall be laid in air as per specifications. Mtr. 922.00
40 Supplying and installation of insulation piecing connector made of UV stablized thermoplastic materials with contact teeth of copper alloy materials, electro galvanized hexagonal head nut and bolt, pressure pad, rubber pads etc. complete connection of Street light/ Distribution Box/ Tee connection /Service connection suitable for 16 to 95 Sqmm. main conductor and 1-5 to 50 Sqmm tab conductor of AB cable. Each 116.00
41 Supplying and fixing of earthing connector (1 bolt type) made of extuded aluminium alloy with electro zinc plated M.S. bolt and washer, pressure epad top clamp etc. complete suitable for 2.5 to 50 Sqmm conductor of ABC cable. Each 29.00
42 Supply and fixing of Univercal Distribution Connector (Tee connector) made of extruded aluminium alloy with clectro galvanized MS U bend, both and washer etc. complete for 16 to 95 Sqmm uninsulated messenger wire of AB cable. Set. 26.00
43 Supply and Fixing of Dead end/anchoring clamp made of extruded aluminium alloy with electro galvanized MS U bend. Both and washer etc. complete for 16 to 95 Sqmm uninsulated messenger wire of ABC cable. Each 20.00
44 Supply and Fixing of Suspension Clamp of Assemble made of aluminium alloy with electro galvanized MS bolt and washer plastic base cover etc. complete suitable for all size cable, bare messenger wire of ABC cable. Each 15.00
45 Distribution box (3- phase) for housing 5 nos. 10 Amps MCCB including acessories for fixing with pole suitable for AB XLPE cable. Each 26.00
46 Providing and fixing earthing arrangement for HT/LT poles with GI lead of 115 turns of 50mm dia connection with bracket/cross arm by pole with 4 mm dia GI lead through 15 mm dia 'B' class approved make GI protection pipe of length from bottom of pole to 1.5 meters above ground level packing of charcoal powder and salt as per specification including excavation of pit in all type of soil / rocks etc. complete. Each 27.00
47 Supplying and fixing 12x16 gauge bar-bed wire ground the existing HT/LT electric pole for safety measures as per IE rules including all staples and all other necessary materials complete as required as per specification. Mtr. 45.00
48 Supplying and Fixing of 11 KV Danger board on HT Pole Each 5.00
49 Design, manufacture, supply and fixing of outdoor type floor mounted weather, dust and vermin proof of IP:55 type LT main feeder pillar distribution box made or 16 gauge MS sheet with clamping arrangements, lockable hinged door duly painted on all sides with red oxide, anti rust and corrosion treatment, two coats of synthetic enamel paints or approved made and shade consisting of following fittings.
(i) Supplying and fixing ABB/L&T/Havells (ISI) Make 63 Amp TPN MCCB, 36 KA approved made for incomer connection - 01 Nos.
(ii) Supplying and fixing 100 Amp 04 Strip aluminium bus bar supported on epoxy insulator - 01 set.
(iii) Supplying and fixing 40 Amp TPN MCCB, 25 KA approved make for outgoing connection - 03 nos.
(iv) Supplying and fixing GI earth terminal - 02 nos.
(v) Supplying and fixing 07 lever goderaj padlock with keys - 02 nos.
(vi) Light points with switch and holder with 1x28 watt CFL-01 nos.
(vii) connecting cables as required.
(viii) Providing Energy meter chamber which is suitable for 3 Phase Energy meter - 01 nos.
(ix) LED type Indicator - 03 nos, Digital ammeter, Voltameter & Frequency with selector switch and Protection Fuse-03 nos. Job 1.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.02 MB
8727834074751158727_190564_1 Form-B.doc
NIT • 0.13 MB
816747415934614128_190564_Detailed NIT.doc
NIT • 0.12 MB
8482647680252547311_190564_shedule.xlsx
BOQ • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .