Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAdmitted-Finance | ₹1.9 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical Not As per NIT |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not as per NIT |
| Sl No | Description | Qty | Unit | SUMAN ENTERPRISE L1 |
|---|---|---|---|---|
| 1.00Items Description | ||||
| 2.00Repairing of Restricted Neutral Grounding System in 315-kVA, 3.3kV/550V, GEC make TSU and 250-kVA, 3.3kV/550V A/Y make TSU of Patmohana Colliery under Sodepur Area. | ||||
| 2.01 | Supply installation of Neutral Grounding resistance to be housed in FLP transformer at secondary side Terminal/switch control Box capacity 550V, E/L relay 750mA(Max), Complete with fail safe relay, Trip Coil assembly, Auxilary wiring Neutral to Ground Earth via Neutral Grounding resistance etc. | 2 | Nos. | 65,000 ₹1,30,000 Lowest |
| 2.02 | Cost of electronic earth leakage relay with CBCT with capacity 750mA | 2 | Nos. | 7,000 ₹14,000 Lowest |
| 2.03 | Cost of test reset switch | 2 | Nos. | 250 ₹500 Lowest |
| 2.04 | Cost of trip coil assembly | 2 | Nos. | 2,500 ₹5,000 Lowest |
| 2.05 | Dash pot type overload relay complete set | 1 | Nos. | 6,000 ₹6,000 Lowest |
| 2.06 | Cost of PVC 4 mm copper wire for internal wiring | 2 | Nos. | 1,400 ₹2,800 Lowest |
| 2.07 | Labour cost for repairing | 2 | Nos. | 5,000 ₹10,000 Lowest |
| 2.08 | Overhead cost and others | 1 | Nos. | 16,830 ₹16,830 Lowest |
Tender Value
₹2.0 L
EMD Value
₹2,600
Closing Date
26 Mar 2026, 1:00 pmClosed
Area Engineer(EnM)
Area Engineer(EnM),Sodepur Area
Repairing of Restricted Neutral Grounding System in 315-kVA, 3.3kV/550V, GEC make TSU and 250-kVA, 3.3kV/550V A/Y make TSU of Patmohana Colliery under Sodepur Area.
2026_ECL_356897_1
ECL/SDPA/AE(EnM)/e/25-26/432 dt.16.03.2026
Open Tender
Miscellaneous Works
Item Rate
10 days
Sodepur Area
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,600
28 Mar 2026
17 Mar 2026
27 Mar 2026
17 Mar 2026
26 Mar 2026
17 Mar 2026
17 Mar 2026 - 20 Mar 2026
Items Description
Repairing of Restricted Neutral Grounding System in 315-kVA, 3.3kV/550V, GEC make TSU and 250-kVA, 3.3kV/550V A/Y make TSU of Patmohana Colliery under Sodepur Area.
Supply installation of Neutral Grounding resistance to be housed in FLP transformer at secondary side Terminal/switch control Box capacity 550V, E/L relay 750mA(Max), Complete with fail safe relay, Trip Coil assembly, Auxilary wiring Neutral to Ground Earth via Neutral Grounding resistance etc.
Cost of electronic earth leakage relay with CBCT with capacity 750mA
Cost of test reset switch
Cost of trip coil assembly
Dash pot type overload relay complete set
Cost of PVC 4 mm copper wire for internal wiring
Labour cost for repairing
Overhead cost and others
Add. CMPF/EPF @ 12% on Labour charges
Add. Bonus @ 8.33% on Labour charges 8.33%
Add. Pension @ 7% on Labour charges
Total impact of GST for the purpose of CTC
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.69 MB
Tendernotice_2.pdf
PDF • 1.18 MB
BOQ_369750.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .