Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | Admitted-Finance |
| 5 | Admitted-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | Admitted-Finance |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
24 Jun 2020, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI CHENNAI 600054
REPAIRS MAINTENANCE OF INTERNAL WIRING FIXTURES AND CONNECTED WORKS AT MD ACCN RESIDENTIAL AREA AT CVRDE AVADI
2020_MES_348034_1
8309/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AVADI
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹19,000
Yes
6 Jul 2020
28 May 2020
27 Jun 2020
28 May 2020
24 Jun 2020
10 Jun 2020
28 May 2020 - 10 Jun 2020
Amount
M&L for taking down carefully copper/aluminium point wiring (light fan socket or power) complete including fixtures such as switches, ceiling rose, pendants, regulators, sockets etc removing retrieved materials and making good the disturbed surface all as specified and as directed.
M&L for Point wiring with 1100Volts grade, single core, PVC insulated FRLS cable multi-stranded copper conductor of size 1.5 sqmm nominal area for phase and neutral, drawn through and including PVC casing caping of suitable size, with all necessary fittings and accessories fixed on walls/ ceiling with one run neutral and one run of single core cable of same description above but green colour in continous earthing wire connected to common earth dolly including PVC junction / mounting boxes on / in the wall / ceiling for piano switches/ switch socket combination/ fan regulators etc and MS/GI junction box duly covered with 3mm thick hylam sheet complete for the following :-
(a) One light point controlled by one single pole 5A switch
(b) One fan point controlled by one single pole 5A switch
(c) One switch socket out let point 5A on independent board
(f) One bell point controlled by one single pole 5 Amps bell push
All as per item No 2 here in before but for PVC insulated FRLS copper conductor of size 2.5 sqmm for switch socket multipurpose 15 Amps including provision of 2.5 Sq mm PVC insulated FRLS copper conductor cable as earth continuity conductor on independent board
All as per item No 2 here in before but for PVC insulated FRLS copper conductor of size 4.0 sqmm for switch socket multipurpose 15 Amps/metal clad point including provision of 4Sq mm PVC insulated FRLS copper conductor cable as earth continuity conductor on independent board
S&f in repair for switch piano flush type single pole one way 5A complete all as specifed and directed.
S&F in repair for switch piano flush type single pole one way 15A complete all as specifed and directed.
S&f in repair for bell push piano type one way 5 Amps complete all as specifed and directed.
S&F in repair for switch socket combination 2 in 1 3Pin 5 and 15A flush type universal all as specified and directed.
S&F in repair for switch socket combination 2 in 1, 5 A flush type complete all as specifed and directed.
S&F in repair for Socket out let 2 in 1, 3 Pin , 5 and 15 Amps flush type complete all as specifed and directed.
S&F in repair forSocket out let 3 Pin , 5 Amps flush type complete all as specifed and directed.
S&F in repair for bell AC. 230 volts complete all as specifed and directed.
S&F in repair for modular switch 6A one module all as specifed and directed.
S&F in repair for modular switch 16A one module all as specifed and directed.
S&F in repair for modular Bell push 6A 1 module complete all as specifed and directed.
S&F in repair for modular Socket, 6A - 2/3 pin combined 2 module,complete all as specifed and directed.
ModularSocket 6A/16A 2/3 pin combined 2 module, all as specified and directed.
S&F in repair for stepped type electronic fan regulator flush socket type complete all as specifed and directed.
S&F in repair for modular type fan regulator 120W 2 Module type all as specifed and directed.
S&F in repair for white cover plate with frame, 4module complete all as specifed and directed.
S&F in repair for white cover plate with frame, 6module complete all as specifed and directed.
S&F in repair for modular metal flush box 4 module complete all as specifed and directed.
S&F in repair for modular metal flush box 6 module complete all as specifed and directed.
S&F in repair for ceiling rose 3 phase/PVC/polycarbonate, isolated body three terminal complete all as all as specifed and directed.
S&F in repair for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings as specified and as directed.
S&F in repiar for MCB TPN DB 6Way double door 415V with sheet metal enclosure complete all as specifed and directed.
S&F in repair for MCB SPN DB 8Way double door 240V with sheet metal enclosure complete all as specifed and directed.
S&Fin repair for MCB SPN DB 12Way double door 240V with sheet metal enclosure complete all as specifed and directed.
S&F in repair for Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with single pole MCB 20 Amps 240 Volts AC all as specifed and direcdted.
M&L for taking down fan, sealing cable end,dismantling blades and removing fan and blades to store complete all as specifed and as directed.
M&L for taking down Exhaust fan any sweep, sealing cable end, dismantling blades to store complete all as specifed and directed
M&L for Painting of ceiling fans, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and numbering of ceiling fan of any size complete all as directed.
M&L for hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specifed and directed.
M&L for hanging only exhaust fan any type and connecting up including provision of cable from ceiling rose or connector to fan complete all as specifed and directed.
S&F fix in repair Earthing complete with galvanised steel earth plate electrode 60x60cm x 6.0mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to and including using of 4 mm GI wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised steel , connected to earthing test point, all as specified & indicated, including testing on completion including earth work and excavation in any type of soil/rock, PCC 1:3:6 type C1, earthing chamber, precast RCC slab 50mm thick in cement concrete 1:2:4 type B1 reinforced with welded steel wire febric weight hot less than 4 Kg/Sqm, funnel with GI watering pipe of 20mm bore, medium grade wire mesh and lugs, GI protection pipe of 15mm bore light grade upto 7.50 mtr long test point and testing complete etc all as specified and directed. Note: (i) Cost of GI earth lead wire and GI protection pipe upto 7.5m length deemed to be included in the rate quoted. (ii) Quoted rate shall deemed to include the cost of excavation and earth work in any type of strata.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for building earthing etc,as required of 4mm GI wire and removing retrived materials and making good the distrurbed surface of wall, floor ceiling etc complete
S&F in repair GI tubing 15mm light grade with fitting fixed on wall/flooe for GI wire protection complete all as specifed and directed.
S&F in repair for sub main wiring with 2runs of 2.5sqmm single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade including non-metallic rigid PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including one run 2.5 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
S&F in repair for sub main wiring with 2runs of 4sqmm single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade including non-metallic rigid PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including one run 4 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
S&F in repair for sub main wiring with 2runs of 6sqmm single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade including non-metallic rigid PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including one run 6 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
MCB TPN, 63 Amps, 415 V, C- series with breaking capacity of 10KA complete all as specified and directed.
MCB DP, 40 Amps, 240 V, C- series with breaking capacity of 10KA complete all as specified and directed.
MCB SP, 6-32 Amps, 240V, C- series with breaking capacity of 10KA complete all as specified and directed.
S&F batten 4 feet LED tube light fitting 20W high lumen efficiency, min 5700K and extruded aluminium/polycarbonate/CRCA body with suitable electronic driver suitable for 230V complete with all accessories pre wired, connecting up with and including twin core twisted flexible copper cable of suitable size complete inclluding taking down unserviceable FTL fitting any type any watts all as specified and directed. Havells Cat No LUMILINEBS20WLED865SPCWH or equivalent of PHILLIPS / BAJAJ / JAQUAR
S & F batten 2 feet LED tube light fitting 9W high lumen efficiency, min 5700K and extruded aluminium/polycarbonate/CRCA body with suitable electronic driver suitable for 230V complete with all accessories pre wired, connecting up with and including twin core twisted flexible copper cable of suitable size complete inclluding taking down unserviceable FTL/CFL fitting any type any watts all as specified and directed. Make Havells Cat No LUMILINEBS9WLED865SPCWH or equivalent of PHILLIPS / BAJAJ / JAQUAR
Supply and fix in repair for capacitor 2.5 mfd suitable for ceiling fan complete all as specifed and directed.
M&L for dismantling ceiling fan, remove wornt out bearing , burnt winding and cleaning the slot, rewinding with super enamelled copper wire of suitable size, varnishing heating and insulating icluding fixing of ball bearing/bush complete all as specified.
M&L for dismantling exhaust fan 300mm sweep, remove wornt out bearing , burnt winding and cleaning the slot, rewinding with super enamelled copper wire of suitable size, varnishing heating and insulating icluding fixing of ball bearing/bush complete all as specified.
S&F in repair louvers suitable for exhaust fan 300mm size complete all as specifed and directed.
M/S SAI SRI HARSHA ENTERPRISES
K Kumar Construction
EASHWAR ELECTRICALS
RAVI ENTERPRISE
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .