Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹21.5 L+₹9,002.50 (0.42%)Rejected-AOC 1 28 NORTH STREET SOUTH VILAYANARAYANAM NANGUNERI TALUK TIRUNELVELI DIST 627 118 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627118 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹24.6 L+₹3.2 L (15.1%)Rejected-AOC CHENNAI | L3 | Rejected-AOC Rejected | |
| 4 | L4₹24.7 L+₹3.3 L (15.5%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
9 Mar 2024, 6:00 pmClosed
GE Tirunelveli
Garrison Engineer Naval Post Base Vijayanarayanam Tirunelveli -627119
8332 DAY TO DAY MAINT,PERIODICALS,CERT B/R REPAIRS TO BLDGS, REPAIR/MAINT TO SEWAGE LINES, COMPOUND WALL,LT LINES,LT PANELS,ALLIED WORKS AND TO SUMMER COOLING APPL 7N DET
2023_MES_635079_2
GE/TVL/8332/E8 of 2023-24
Open Tender
Civil Works - Others
Item Rate
270 days
Ramnad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹37,000
Yes
28 Mar 2024
9 Feb 2024
11 Mar 2024
9 Feb 2024
9 Mar 2024
16 Feb 2024
Amount
Supply and fixing in repair 15mm bore fancy type chromium plated bib tap cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule etc complete all as specified and as directed.
Supply and fixing in repairs pillar taps, fancy type 15mm dia bore, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed.
Supply and fixing in repairs CP brass chromium plated shower rose 125 mm size fixed to 15mm pipe of revolving type complete all as specified and as directed.
Supply and fix in repairs Low density polyethylene pipes (LDPE) waste pipe of pressure rating 6kgf/cm2 fixed complete to walls, or in floors etc.for sinks/basin etc complete all as specified and as directed.
Supply and fixing in repairs 10 litre capacity PVC low level flushing cistern with all accessories complete fixed with WC including syphonic pipe, PVC flushing pipe of size 32mm dia complete all as specified and directed.
Supply and fixing in repairs 15mm dia bore stop cock/angle cock, cast fancy type chromium plated screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe on for unions and fixed complete all as specified and as directed.
Supply and Fix in repairs stop valve 15mm dia fancy type chromium plated with long shank and cup (concealed type) all as specified and directed by the Engr-in-charge.
Supply and fixing in repair Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and as directed.
Supply and Fix in repair Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
Supply and fixing in repairs vitreous China wash basin white, flat back, size 550X400 mm including cutting for pinning in ends of brackets, complete all as specified and as directed.
Supply and fixing in repair vitreous China wash down water closet pan (pedestal pattern) white, incl. P or S Trap , connection to drain and flushing pipe including seat cover for pedestal pan complete all as specified and as directed.
Supply and fixing PVC connection 15mm dia and 600mm long with PTMT nuts complete all as specified and as directed.
Supply and fixing PVC connection 15mm dia and 450mm long with PTMT nuts complete all as specified and as directed.
Supply and fixing in repair 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
Supply and fixing rotational moulded polyethylene water storage tanks 1000 ltrs capacity (White colour), three layer (cylindrical or vertical with closed top) hoisted and fixed in position, including dismantling water tanks complete all as specified and as directed.
Supply and fixing rotational moulded polyethylene water storage tanks 500 ltrs capacity (White colour), three layer (cylindrical or vertical with closed top) hoisted and fixed in position, including dismantling water tanks complete all as specified and as directed.
Supply and fixing in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections complete all as specified and as directed.
Taking up or down steel tubing and connection including removed to store, 15 mm dia bore complete all as specified and directed.
Taking up or down steel tubing and connection including removed to store, 20 mm dia bore complete all as specified and directed.
Supply and fixing 15mm Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., with all fittings fixed complete all as specified and as directed.
Supply and fixing 20mm Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., with all fittings fixed complete all as specified and as directed.
Supply and fixing in repair 100mm mild steel butt hinges medium weight including screws complete all as specified and as directed.
Supply and fixing in repair 75mm mild steel butt hinges medium weight including screws complete all as specified and as directed.
Supply and Fix in repair aluminium anodised barrel tower bolts 200mm size of extruded section complete all as specified and as directed.
Supply and Fix in repair aluminium anodised barrel tower bolts 100mm size of extruded section complete all as specified and as directed.
Supply and fix in repairs aluminium handles Cast type anodized 100 mm size etc complete all as specified and as directed.
Supply and fix in repairs aluminium handles Cast type anodized 150 mm size etc complete all as specified and as directed.
Supply and fix in repairs Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed 300 mm long complete all as specified and as directed.
Supply and fix in repair for plastic Mirror cabinet of size 600 X 400 mm fixed in position using necessary screws complete all as specified and as directed.
Hacking out old broken glass of any thickness/ size of any description from wooden/aluminium frame fixed with clips and putty, and Supply and fix 4mm thick ordinary Sheet glass fixed with clips and putty completed in squares in not exc 0.5 sq.m in each pane complete all as specified and as directed.
Hacking out old broken glass of any thickness/ size of any description form wooden/aluminium frame fixed with clips and putty, and Supply and fix 5.5mm thick ordinary Sheet glass fixed with clips and putty completed in squares in exc 0.5 sq.m in each pane complete all as specified and as directed.
Supply and Fix in repair 100 mm long aluminum anodised hasp and staple complete all as specified and as directed.
Resecuring existing door/window shutter, easing, adjusting without taking down and refixing in the same opening, of any description n.exc 1sqm each complete all as specified and as directed.
Resecuring existing door/window shutter, easing, adjusting without taking down and refixing in the same opening, of any description exc 1sqm but n exc 2sqm each complete all as specified and as directed.
Supply and fix in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fix in repairs door closer hydraulically regulated aluminium extruded section, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and as directed.
Supply and Fix in repair door stopper of aluminium alloy,anodised with hard drawn steel spring of length 150mm complete all as specified and as directed.
Supply and Fix in repair 300mm long Mild steel ordinary rat tail rod pattern springs including roller and roller plate complete and fixed in repairs complete all as specified and directed.
Supply and fix in repairs Mortice lock vertical type, size 100mm of brass 4 Levers complete all as specified and as directed.
Cleaning & removing all scale and dirt, from tanks of capacity exc 500 & not exc 1000 & from mouths of circulating pipes etc., complete all as specified and as directed.
Cleaning & removing all scale and dirt, from tanks of capacity exc 1000 & not exc 2000 & from mouths of circulating pipes etc., complete all as specified and as directed.
Cleaning & removing all scale and dirt, from tanks of capacity exc 250 & not exc 500 & from mouths of circulating pipes etc., complete all as specified and as directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not hacking) removing serviceable tiles to stores and rubbish off premises all as specified.
Material and labour vitrified ceramic tiles with light shade 10mm thick (Square/rectangular) area of each tile not exceeding 0.36 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed.
All as per item No.45 above but in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match including backing coat of 10mm thick in CM 1:4 on brick walls for skirting/DADO complete all as specified and as directed.
Material and labour Non Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 in floors etc complete all as specified and as directed.
Material and labour for 450x350x7mm thick glazed coloured ceramic tiles in vertical surfaces set and jointed in neat cement slurry pointed in coloured cement to match over rendering 10 mm thick on fair faces of brick work in CM (1:4) complete all as specified and directed.
Dismantling boarding, any description, fixed any position with nails including fillets etc complete all as specified and as directed.
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of semi perforated 12mm thk Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance edged square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-charge.
Material and labour for greasing and servicing and necessary repair including welding to steel rolling shutters gear/ manual operated type complete all as specified and as directed.
Supply and fixing in repairs PVC water tank covers/Lit any type for suitable for 500 and 1000 Litre tanks complete all as specified and as directed.
Checking of joinery (Wooden/Steel/Aluminium) Iron/Aluminium mongery, pelmet box, door springs, rolling shutters etc requiring carpentry work and carrying out minor repairs such as tightening of screws/nails seasoning of joinery, door, springs etc, including petty repair material like screws/nails, plug, grease etc to make it functional by attending as a job (Each job contains 5 complaints) complete all as specified and as directed.
Checking and attending to water leakage from taps WC's flushing cistern, urinal wash basins bottle traps etc and any obstruction to water supply in rooms/depts., requiring plumber work and carryout minor repairs such like replacement of washers, tightening of check nuts, tightening of fittings of flushing cistern, cleaning of bottle traps etc including petty materials like washers of all sizes, cotton thread/Teflon tape, pipe clams required size, M-Seal, screws, nails to make it functional and leak proof by attending as a job ((Each job contains 5 complaints) complete all as specified and as directed.
Taking down cement plaster of any description on bricks walls etc, including racking out joints, hacking for keys, scrubbing down with water etc, complete all as specified and as directed.
Material and labour for rendering 15mm thick in (CM 1:4) with WPC on fair faces of brick work or concrete surfaces and to be finished fair and even complete all as specified and as directed. Note: WPC shall be measured paid separately.
Supply only integral water proofing compound
Material and labour Preparation of new plastered surface on wall applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces in camouflage pattern complete all as specified and as directed.
Material and labour for rendering 10mm thick in (CM 1:6)on fair faces of brick work or concrete surfaces and to be finished fair and even complete all as specified and as directed.
Material and labour Preparation of newly plastered surfaces on walls and applying two coats of Oil bound distemper over a coat of primer on walls over a coat of 1mm wall care putty complete all as specified and as directed.
Material and labour rendering 5mm thick Cement plaster in cm 1:3 as in ceiling , surfaces finished even & Smooth (without using extra cement) complete all as specified and as directed.
Material and labour for preparing newly plastered surfaces and applying three coat of white wash on ceiling complete all as specified and as directed.
Material and labour for Preparation of old painted surfaces by washing, rubbing, brooming down or steel wire brushing or scraping down and applying one coat of White wash on ceiling complete all as specified and as directed.
Material and labour Preparation of old painted surfaces of wall and applying a coat of Oil bound distemper complete all as specified and as directed.
Material and labour preparation for complete removal of old painting with vacuum based sanding machine and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over in camouflage pattern on walls complete all as specified and as directed.
Material and labour for Preparation of old painted surfaces by washing, rubbing, brooming down or steel wire brushing or scraping down and applying one coat of cement base paint on walls complete all as specified and as directed.
Material and labour preparation of old decorated wooden surfaces of any description over 10cm in width of girth and applying one coat on synthetic enamel paint complete all as specified and as directed.
Material and labour preparation of old painted steel surfaces over 10 cm in width of girth and applying one coat on synthetic enamel paint complete all as specified and as directed.
Material and labour Writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30cm high (per cm of height) complete all as specified and directed.
Removing of plants including roots by dismantling of brick work / PCC / RCC including necessary scaffolding, any type, any location /height ( i.e. roof, parapet walls near pipes etc.) and applying Acid after removing roots for preventing the regrowthing and making good the disturbed portion using PCC 1:2:4 Type B-0 and plaster in CM 1:3 (size of disturbed portion 150*150*150mm) complete all as specified & directed by Engr- in -Charge.
Demolition of brick work or stone/boulder masonry, built in cement or lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Material and labour for Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Taking down Chowkhats or frames with shutters (without taking off shutters from the frame) exe 1.5Sqm n exe 4Sqm each and removing to stores etc complete all as specified and as directed.
Supply and fixing 2nd class hardwood Plain, solid, straight Chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed.
Supply and fixing 30mm thk 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to Chowkhats but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers complete all as specified and as directed.
Supply and fixing 40mm thk 2nd class hardwood Plain, framed, paneled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to Chowkhats complete all as specified and as directed.
Supply and fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
Supply and fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, complete all as specified and as directed.
Supply and Fix aluminium anodised barrel tower bolts 200mm size of extruded section complete all as specified and as directed.
Supply and Fix aluminium anodised barrel tower bolts 100mm size of extruded section complete all as specified and as directed.
Supply and fix aluminium handles Cast type anodized 100 mm size etc complete all as specified and as directed.
Supply and fix aluminium handles Cast type anodized 150 mm size etc complete all as specified and as directed.
Supply and fix Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed 300 mm long complete all as specified and as directed.
Supply and fix 4mm thick ordinary Sheet glass fixed with clips and putty completed in squares in n exc 0.5 sq.m in each pane complete all as specified and as directed.
Supply and fix Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fixing 2nd class hardwood Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labors; articles n exc 200 cu.cm each complete all as specified and as directed.
Material and labour preparation of new wooden surfaces of any description over 10cm in width of girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Material and labour Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed.
Material and labour At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed.
Demolition Concrete in ground floors unreinforced and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Material and labour for 75mm thick cement concrete type C-2, ( 1:3:6) (40 mm graded aggregate) as in plinth protection finished even and smooth without using extra cement etc complete all as specified and as directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
Supply and fixing prepainted galvalume aluminium zinc coating GI based plain sheet 0.5mm thk of an colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Material and labour in repair 75 mm dia PVC(SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed.
Material and labour in repair 110mm dia PVC(SWR) gully trap setting and hoisting with solvent cement complete all as specified and directed.
Checking and attending to sewage line/manhole/septic tank blockage/ leakage by cleaning of drains of dia not exceeding 150 mm including blocked manholes / Nahni traps/gully traps/WCs by rodding from manholes and well flushing after cleaning and removal of blocked/decomposed sludge/dirt and other material not exc 50 m and burning the same including removing and re fixing manhole covers without damaging complete by attending as a job complete all as specified and as directed.(Each job contains 5 complaints). .
Cleaning of septic tank bailing out fluid, decomposed materials sludge etc, scrapping and disposal of decomposed materials, sludge etc out side MD land using septic tank cleaning tanker vehicle complete all as directed by Engr-in-charge for the following septic tanks :-
(a) 100 users septic tank
(b) 50 user septic tank
(c) 25 User septic tank
(d) 10 Users septic tank
Excavation in trenches, not exceeding 1.5 M wide, and not exceeding 1.5 M in depth for foundation etc and getting out in soft soil complete all as specified and as directed.
Returning filling in trenches including spreading levelling watering and well ramming in layers not exc 25cms in soil as specified and directed Engr-in-Charge
Removing excavated material/soil to a distance not exc 250 mtr but n exc 500 m away and deposing where as directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engr-in-charge
Demolition and breaking up SWG drain pipe of 150mm dia set in cement concrete as in trenches complete all as specified and as directed.
Material and labour for Plain cement concrete 1:3:6 type C2 (using 40mm graded granite stone aggregate) as in concrete bed to drain pipes for 150 mm dia including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Material and labour 150 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars as specified and as directed by Engr-in-Charge
Material and labour for brick work with sub class 'B' bricks old size straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and as directed.
Material and labour Plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in benching to manholes, coping etc.. including necessary formworks complete all as specified and directed.
Demolition of Plain cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
Material and labour for Plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed.
Material and labour for PCC (1:2:4), type B2 in surface channel & drains incl necessary form work complete all as specified & directed.
Demolition of cement concrete reinforced cover slabs of man holes etc n.exc 15 cm thick complete all as specified and as directed.
Material and labour for Precast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in manhole/ gully trap cover slab set in cement mortar 1:4 including necessary form work all as specified and directed.
Material and labour for TMT bars 10mm and over cut tro length, bend to shape required incl cranking, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed
Material and labour for preparation of new plastered wall surface and applying two coat of cement base paint over a coat of primer complete all as specified and as directed.
Material and labour preparation of old steel surfaces over 10 cm in width of girth and applying one coat on synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engr-In-Charge. Note: The painting should be done with spray paint machine.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipes and getting out in any type of soil, complete all as specified
Spreading of riddled earth obtained from trenches for cable cushioning on top and bottom of cable as specified for cable protection complete all as specified and directed. (Note: Only punned thickness of riddled earth shall be measured)
Supply and lay bricks in trenches , common burnt clay building bricks, subclass `B’ designation 75, old size ,with width equal to the length of the brick; complete all as specified and directed.
Material and labour for horizontal direction boring under road for laying 50 mm dia GI Pipe at a depth not less than 450 mm and not exc. 800 mm complete all as specified. Note : The rate is inclusive of all the materials, equipments and labour required for doing trenchless horizontal boring under the road, nothing extra shall be admissible on any account then the rates quoted above.
Demolition, Cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed.
Supply and lay LT under ground cable 1100 volts grade Cross linked Polyethylene (XLPE) insulated PVC Sheathed Cables: armoured multistranded heavy duty electric cable with aluminium conductor laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board, testing and commissioning etc including taking out existing unserviceable cables of following sizes complete all as directed & as specified:-
(a)4 Core 16 Sqmm
(b)4 Core 25 Sqmm
(c)3.5 Core 35 Sqmm
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 32x6mm GI strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 connected to earthing test point, including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wire mesh ,funnel, lugs and charcoal, salt etc all as applicable including taking down old unserviceable earthing complete for taking into credit all as specified and as directed by the Engineer-in-Charge Note:-(i) The rates quoted is inclusive of 32x6mm GI strip earth conductor upto a length of 7.5m from the earth pit.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised steel earth wire 4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 connected to earthing test point, including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wire mesh ,funnel, lugs and charcoal, salt etc all as applicable including taking down old unserviceable earthing complete for taking into credit complete all as specified and as directed by the Engineer-in-Charge complete all as specified and as directed by the Engineer-in-Charge Note:-(i) The rates quoted is inclusive of 4mm dia GI earthing lead upto a length of 7.5m from the earth pit.
Supply , installation, testing and commissioning of outdoor LT feeder pillar box , CPRI Approved , factory fabricated in an factory having modern fabrication and testing process which includes seven tank pre-treatment process comprising of degreasing, rinsing, de-rusting , rinsing, phosphatising, rinsing and passivation followed by power coat painting having thickness not less than 100 microns .The bus bar chamber comprising of high conductivity aluminium bus bar of capacity 300 Amps three phase and half the capacity for neutral. The doors shall be provided with suitable gasket and latc including PCC foundation for erecting the panel board. Feeder pillar shall be suitable to accommodate the following as specified and as directed.:- OUTER SHELL : The outer shall be made out of 3.15 mm thick CRCA sheet &MS angle section 50x50x6 mm frame, factory fabricated with front & back open able, double door system lockable/open able by keys from both sides having chromium plated locks. ‘U’ type gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate of thickness 3.15 mm powder coated having provision for entry of armoured cable of adequate size with glands. The outer shell shall be powder coated Siemens grey structural RAL 7032 shade.
INNER SHELL : inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, front & back open able single door system lockable / open able by keys from both sides having chromium plated locks (2 Nos in each compartment),having louvers & air vent gasket for natural flow of air. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size ‘F’ class insulator made on non hygroscopic, non combustible , track resistant, high strength FRP/SMC/DMC material at an interval not more than 500mm throughout the length of the TPN bus bar. INCOMING (a) MCCB 415 V,200 A, 4 pole breaking capacity 36 KA- 01 Nos. (b) Manual switch 200 A - 01 Nos. (c) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---1 Job OUT GOING (a) MCCB 100 A, 415V , 4 pole , breaking capacity 16 KA - 02 Nos (b) MCCB 63 A, 415V ,4 pole , breaking capacity 16 KA - 05 Nos (c) MCB 40A, 415V , TPN , 10kA C Curve - 03 Nos (d) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---7 Job
Supply and fix in replacement MCCB four pole 415 volts 50 Hz , 125 amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for taking down old unserviceable old damaged GI pipe and S/F new GI pipe light grade of size 50mm dia for protection of UG cable on walls/under floors/road crossings/in trenches including taking down old unserviceable earthing GI pipe for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for cable route indicator 150mm dia 3mm thick made out of cast aluminum duly marked with size and type of cable fixed on 40x40x6mm angle iron support embedded in PCC 1;2:4 type B1 using 20 mm graded (300x300x400mm size) and painted with 2 coats of anticorrosive paint over a coat of red oxide primer all as specified and as directed.
Supply and fixing in replacement street light controller panel for controlling street lights in wall / supporting system made of GI , with following specification : 3 phase, Max Load - 6 kW , with astronomical timer switch ,contactor rating - 65 A TP, Provided with Protection Degree IP 54 , FRLS (Fire retardant low smoke) Internal wiring ,In-built Short-Circuit Protection , Class H Insulation complete all as specified and as directed.
Providing comprehensive annual maintenance periodical/preventive maintenance of cooling appliances ( Split type Air Conditioners, Water coolers, Refrigerators and Deep Freezers) as per manufacturer specification by providing one AC/Refrigeration mechanic including replacement of components as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:- (a) Cleaning of coil unit with dust blower, lubricate the indoor and outdoor fan motor with oil. (b) Cleaning of air filters, indoor unit grills & filters through air blower. (c) Checking and cleaning the drain connection and air filter periodically, washing of coil with ventiklean solution once in a contract period. (d) Check and replace the refrigerant pipe once in a contract period or as and when required. (e) Check and repair the minor electrical fault in incoming supply. (f) Check and replace the water PVC pipe. (g) Replacement of faulty spares/components (h) Carry out the monthly, quarterly and annual maintenance of all cooling appliances of any make & capacity with job card and making the Cooling Appliances functional (Each Job contains 3 Complaints)
Supply only the following new items for 1.5 / 2.00 Ton Capacity Split type AC including testing and commissioning etc complete all as specified and as directed.
Capacitor 60 MFD.
Air filters.
Condenser fan motor 1.5 HP with blade set .
Blower fan motor 1.6 HP with blade set.
Blower with circular leaf.
Copper condenser coil unit (for A/C)
Copper cooling coil unit (for A/C)
Indoor motor capacitor 2.5 MFD. Make:
Strainer tube (copper)
Capillary tube (copper)
Non return valve (For gas top up charging)
Remote control suitable for Non inverter model Split AC. Make : LG
Remote control suitable for inverter model Split AC. Make : Daiken
PCB board suitable for indoor unit of Non inverter model split AC 1.5/2.0 TR
PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR .
PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR .
Copper pipe of size 1/2" for suction line with foam insulation
Copper pipe of size 1/4" for discharge line with foam insulation
Swing Motor for indoor unit
Outdoor unit stand
Condenser fan motor blade
Indoor Motor blower
Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :-
Split type AC 1.5 Ton capacity.
Split type AC 2.0 Ton capacity.
Material and labour for repair to stabilizer of capacity 4 or 5 KVA capacity by removing the old / burnt transformer and replaced with new transformer complete all as specified and directed.
Material and labour for repair to stabilizer by removing the old / burnt relay board suitable for Voltage stabilizer of capacity 4 KVA / 5 KVA complete all as specified and directed.
Supply and fix condensed water PVC flexible pipe of standard quality of suitable size fixing with suitable clamps on wall for split type AC of capacity of 1.5/2.0 Ton complete all as specified and as directed.
Supply only R22 /R32 /R410 Gas complete all as specified and directed.
Supply only R134a Gas complete all as specified and directed.
Dismantling and disconnecting carefully the existing split AC 1.5/2.0 Ton capacity after disconnecting the copper pipe and electrical connection, Cleaning the refrigeration system with CO2 and fixing in a new position including, brazing, testing and commissioning complete all as specified and directed. NOTE : The weight of refrigerant used for filling/top up shall be measured and paid under respective item.
Supply only 2 nos of 1/2" x 3/8" Foam Heat Insulated Pipe Black for Air Conditioner complete all as specified and directed.
Material and labour for making good of surface with sealing the cavity /hole drilled to facilitate tubing, using white cement/POP and cleaning the surface to match with existing surface complete all as specified and directed.
sri manikandan enterprises
VVM CONSTRUCTIONS
ARUVI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .