Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹34.4 L+₹2.6 L (8.17%)Rejected-Finance 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹35.8 L+₹4.0 L (12.5%)Rejected-Finance UTARLAI KAWAS BARMER RAJASTHAN 344 001 | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.3 L+₹5.5 L (17.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹43.7 L+₹11.9 L (37.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹44.4 L
EMD Value
₹89,000
Closing Date
24 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Utarlai
GE (AF) Utarlai PB No. 11 Barmer (Raj) 344001
ADDN/ALTN OF OLD ARMOURY BUILDING AND PROVN OF FIRE BREAKS AROUND ELECTRIC POLE AND JUNCTION BOX INSIDE WSA AT AF STN UTARLAI
2024_MES_653303_2
8512/E8
Open Tender
Civil Works
Item Rate
365 days
Utarlai
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Utarlai
₹89,000
Yes
6 Sept 2024
3 Jun 2024
26 Jun 2024
3 Jun 2024
24 Jun 2024
10 Jun 2024
Amount
Dismantling cast iron work of any description
Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed
Demolition Cement concrete (unreinforced) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of sizen exceeding exceeding 1.50 Sqm each complete all as specified and directed .
Removing building materials etc. (other than spoil payable under items to adistance of 100m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination
Demolition of brick work or stone/boulder masonary built in cement mortar of any specification and in any position complete all as specified.
Taking down Chowkhats or frames not exc. 1.5 sq. m eachbut with shutters (without taking off shuttersfrom the frames
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded
Excavating in trenches,Soft soil n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, ells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil all as spd.
Removal of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point all as spd.
M & L for cement concrete 1:4:8 type D2 using (40mm graded stone aggregate) as in mass concrete for foundation complete all as specified
M & L for Reinforced cement concrete (design mix) M-25 (20mm graded stone aggrgate) in:-Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, complete all as specified and directed
M&L for Reinforced cement concrete (design mix) M-25 (20mm graded stone aggrgate) Columns, pillars, piers, posts and struts complete all as specified and directed
M&L for Reinforced cement concrete (design mix) M-25 (20mm graded stone aggrgate) Beams, cantilevers beam bressummers, lintels span complete all as specified and directed
M&L for Reinforced cement concrete (design mix) M-25 (20mm graded stone aggrgate) Slabs supported on walls, beams and columns in floors, roofs, andings, balconies, canopies, deck slabs complete all as specified and directed
M &L for Reinforced cement concrete (design mix) M-25 (20mm graded stone aggrgate ) Chajjas Slabs supported on walls, beams and columns in floors, roofs, andings, balconies, canopies, deck slabs complete all as specified and directed complete all as specified and directed
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed
Formwork to chullah hoods, chajjas,troughs and similar items including edges
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams,
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;exceeding 200mm thick (Horizontal or slopingcomplete all as specified and directed
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening, the formwork
Formwork to sides of pillars, posts, struts, piers, columns and stanchions
M&L for MS TMT bars (Fe 500),10 mm dia and over in reinforcement cut to length, bent to shape required incl bending spirally cranking, hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified.
M&L for MS TMT bars (Fe 500),8mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified.
M&L for precast cement concrete block masonry with solid blocks made of PCC (1:3:6) type C1 using 20mm graded stone aggregate exc 10cm in width and set in CM 1:6 complete
M & L for Rendering 10 mm thick on fair faces brick surfaces in cement mortar 1 : 4 complete all as specified.
M&L for preparation on new plaster surface of walls & applying two coat of oil bound distemper over a coat of primer complete all as specified and directed
M & L for Rendering 15mm thick on fair faces brick surfaces in cement mortar 1 : 4 finished even and smooth without using extra cement complete all as specified.
M &L for Applying two coats of cement based paint over concrete or newly plastered suraces incl preparing new plastered surfaces.
M&L for 5mm thick rendering in CM 1:3 on ceiling /concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for preparation on new plaster surface of ceiling & applying three coat of white wash complete all as specified and directed
M&L for applying roof treatment on top of roof with APP modified membrane with non woven polyester reinforcement (centre core) shall be laid by torch application method with overlap 100mm on length side and 100mm on width side including a coat of bituminious oil based primer ( IS : 3884) @ 250gm / Sqm weight not less than 3 kg/Sqm including taking down old roof treatment and applying 10mm thick in cement mortar (1:4) on concrete surface as on roof slab, finished even and smooth without using extra cement mix with water proofing compound as per manufacturer instruction complete all as specified and directed
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded
supplied and fixed Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed
S&F 40mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides one face is covered with decorative face veneer with lipping/frame to match
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets
S& F 605mm X 605 mm Anodised aluminium snap grid frame work for false ceiling all as specified
S&F 12 mm thick Perforated particle board/ tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber framework or with staples or on snap grid as in ceiling , complete all as specified and as directed.
S&F for Glazed coloured ceramic tiles in vertical surface 300x 450x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match ,including 10 mm thick plater / screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
M & L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete(mirror type)Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes complete all as specified.
S&F150mm Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed
S&F 300 mm Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed
S& F 125mm Butt hinges, Medium weight, cold rolled mild steel, and fixed
S&F framed work such as grill, grating, etc. with end of bars shouldered and / or revited,or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, frame work of water tanks and similar work con -forming to Fe.290. Gde-E-165.
M& L 75 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate)
M&L sand filling under floor on in foundation in layers not exceeding 25cm each layer including watering and well ramming complete all as specified.
M&L for preparation for new steel surface of any description over 10cm in width or girth not other wise described applying two coat of synthetic enemel paint over one coat of red oxide primer all as specified.
M & L for framed work such as doors, gates or frame for cooler stand of angle or other section with gusset plates, rails, braces etc, drilled for fixing of sheeting or other covering of door etc, to be prepared for hanging or sliding etc with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other coverings running rails and guides ) conforming to Fe 410- W( Gde E-250) quality A and hanging and fixing complete all as specified and directed.
M & L Hard core, Broken stone/ bouldersbroken to gauge n exc 63 mm
S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and and average width of aperture 1.40mm fixed with stainless steel wire staples, complete all as specified and directed
M&L providing of cement concrete typeB1 1:2:4( 20mm graded stone aggregate , cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, bed plates,hold fast for door and window and throating, complete all as specified and directed
Cutting openings, through brick /stone walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting outdefective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m
Cutting holes in brick walls in stone wall mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required
M&L 75 mm Cement concrete type C- 2,1:3:6 (40mm graded aggregate)
Supply, erect, joint, test and commission LT Panel, indoor type, weather/dust/vermin proof, Double door, factory made suitable for 3 phase 4 wire, 415 Volts AC supply and having bus bar chamber of 4 Nos Aluminium bus bars not less 160 Amps rating, 3 phase 415 volts for distribution system and type tested at CPRI, fabricated in factory having modern fabrication and testing facility which includes seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-66 and general construction conforming to IS : 13947. The panel shall be made out of 3.15mm thick CRCA (Cold Rolled Close Annealed) mild steel sheet and 3.15mm thick gland plate duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and mild steel channel base frame at bottom and having welded 04 Nos equal mild steel angle iron of size 50mmx50mmx5mm of length 0.9m, 30cm of of angle shall be embedded in PCC (1:2:4) type B-1 using 20mm graded stone agregate below GL level and 30cm shall be above ground level of size as directed at site.
The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dessipation. Necessary cable gland shall be provided for all incoming and outgoing cables. The feeder pillar shall be comprising of the followings and all as shown in drawings :- CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated multi-stranded type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.INCOMINGS (i) MCCB 4 Pole 100 Amps, 415 Volts, 16 KA breaking capacity - 01 No. OUTGOINGS : (i) MCB TPN 63 Amps, 415 Volts, 10 KA breaking capacity 'C' Curve - 01 No.(ii) MCB SPN 40 Amps, 240 Volts, 10 KA breaking capacity 'C' Curve - 03 No. (iii) MCB SPN 32 Amps, 240 Volts, 10 KA breaking capacity 'C' Curve - 03 Nos. (iv) Cl 1.0 multi-function meter capable of measuring V, A, F, PF - 01 Nos. (v) LED indication lamp 230 Volts, RYB-03 Nos
Supply & laying XLPE PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade for 35 sqmm 3.5 core
Supply & laying XLPE PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade for 10 sqmm 4 core
Supply & laying XLPE PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade for 6 sqmm 2 core
M & L for sand cushioning all around the cable for protection by natural tibba sand
Supplying and Laying stone patti 40-50 mm thick, 25- 30 cm wide abutting each other for cable protection
M&L in replacement of earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron earth strip 32 mm x 6 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, (in any type of strata ) charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete.Note:-(i) GI strip 32X6mm with GI protection pipe upto 7.5 mtr length shall be deemed to include in this items rate.(ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contractor.
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
S&F Aluminium Strip 25 x3 mm with SMC insulators 50 cm C/C and fixing Screws for Roof/ Earth Conductors and Down Conductors above Ground all Joints should be connected complete all as specified and as directed. NOTE : All Joints should be joined by Brazing and by using of stainless steel nuts and bolts
S & F Air Termination Single Pointed Aluminium Rod 12 mm dia and 300mm long with Galvanised Steel Tubing 40mm bore (dia), 1.20 Metre long, light grade fxed on Cement Concrete 1:2:4 (20mm graded stone aggregate) Block 300x300x300mm and necessary Fixing Arrangement at Roof, complete all as specified and as directed. NOTE : PCC will be measured and paid saperately under relevant item of Sch. If threaded of the GI Tubing is damaged then Contractor will be responsible for cutting of thread for fixing the GI Tubing.
M&L for Cement Concrete 1:2:4 (20mm graded stone aggregate) Block 300x300x300mm for fixing of GI pipe,Block 100x100x100mm and necessary Fixing Arrangement at Roof for fixing of Aluminium strip on roof, complete all as specified and as directed.
Supply and lay High Density Poly-Ethylene (HDPE) pipe 50 mm dia of pressure rating 6 kgf/cm2 with all fittings laid in trenches complete for protection of cable.
S&F test point terminal block made of gunmetal or prosperous bronze size 75x75x25 mm drilled and screwed including 3 nos 8 mm dia 25 mm long hexagonal screw.
Supply and lay High Density Poly-Ethylene (HDPE) pipe 40 mm dia of pressure rating 6 kgf/cm2 with all fittings laid in trenches complete for protection of earth strip.
Supply and fix GI strip 32x6mm for loop earthing laid in ground. Note :- Earth work will measured and paid saperately.
Taking down od U/S copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Taking down old U/S flame proof lights
Taking down od U/s flame proof switches
Taking down old U/S flame proof SPN DB
Material and labour for point wiring complete with 1.5 sqmm single core multistandard copper conductor fire resistant low smoke and low halogen (FRLSH) PVC insulated and unsheathed cable 1100 Volts grade conforming to IS-694 drawn through concealed non metallic rigid PVC heavy duty conduit (min 20mm dia (external) but shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling including cutting chasing and making good the disturb surface to match with existing surface and including 1.5mm FRLSH PVC insulated unsheathed copper earth wire complete all as specified and directed.
One light point controlled by one way switch.
One Ceiling Fan/Wall Mounted Fan/Exhaust Fan Point controlled by one way switch
S&F Modular switch 1 way 6A, 1 module complete all as specified and directed.
S&F Modular white cover plate with frame 4 module complete all as specified and directed.
S&F Modular white cover plate with frame 3 module complete all as specified and directed.
S&F Modular white cover plate with frame 1 module complete all as specified and directed.
S&F Metal flush box 1 module complete all as specified and directed.
S&F Metal flush box 3 module complete all as specified and directed.
S&F Metal flush box 4 module complete all as specified and directed.
S&F concealed submain wiring complete with two runs of 4.0 sqmm single core multi stranded copper conductor FRLSH PVC insulated but unsheathed cable 1100volts grade drawn concealed though non metallic rigid PVC heavy duty conduit (min 20mm dia (external) including conduit accessories and fittings, cutting & chasing and making good the disturb surface to match with existing surface and including 4.0 sqmm single core multi starnded copper conductor FRLSH PVC insulated but unsheathed cable 1100 volts grade as earth wire complete all as specified and directed. Note : All runs of cables and 1 run of conduit shall be measured and paid as one metre length of unit.
S&F, LED, light fitting, 18 /20 Watt, illuminiation more than 120 lumen per watt 6000K, decorative ultra slim LED light fixture with extruded heat shrink environmental friendly energy efficient complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as directed by Engr-in-Charge.
S & F plug and socket 3 pin outlet industrial type 250 Volts with MCB SP 20 AMP complete all as specified and directed.
Supply and exhaust fan, steel body AC single Phase. 230V of size 380mm sweep with, blades, and frame and louvers complete all as specified and directed.
S/F Sheet metal enclosures for fixing MCBs Single pole and neutral 8 way, 240 volts with 100 Amps rated bus bar with double door fixed on flush to the wall including making the hole in the wall and fixing the DB including cement work and plastering complete all as directed
Supply and fixing MCB SP, 6 to 32 Amps 10 KA single pole AC 230 volts 'B' curve complete all as specified
Supply and fixing MCB SPN 63 Amps 10 KA AC 230 volts 'B' curve complete all as specified
Supply and fixing MCB SPN 32 Amps 10 KA AC 230 volts 'B' curve complete all as specified
S&F SP metal enclosure complete all as specified and directed.
M & L Earthing complete with 60cmx 60cmx3mm thick GI plate electrode buried in ground vertically not less than 2.25mtrs deep below ground level with top edge of the plate not less than 1.5mtrs below ground level with GI wire of size 4 mm dia as earthing lead including necessary excavation and earth work (in any of strata) providing charcoal dust, salt mixed in continuous layer 15 CM all around the plate and balance pit will be filled with vigitable soil approved by engineer in charge, PCC (1:3:6 ) type C1 in chamber ,Precast 50 mm thick in cement ( 1:2:4) type B.1 with CI frame with cover, 20mm dia bore light grade GI watering pipe funnel etc fixing of GI Pipe 15 mm bore protection for earthing wire from earth pit to test point complete & making connection all as directed by Engineer-in-Charge. Note:-(i) GI wire 4 mm dia upto 7.5 mtr length shall be deemed to include in this items rate. (ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contactor.
S&F Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp
S&F split type flameproof air conditioner 1.5TR suitable for “Ex-d IIC” IP66 230V AC, 50 Hz single phase, hermetically sealed compressor with flameproof terminal box, R-407 CFC free refrigerant gas, flame proof induction motor of S1 Duty and “ Ex-d IIC” Zone-1 IP 66 for indoor cooling unit, copper tubes with aluminum fins, Flame proof control panel with Main incoming MCB-2 Pole 25 amps -01 No, Indicating lamp-01 No, contactor overload set for protection-02 Nos flame proof thermostat for temperature variation. Temperature class T6, Earthing 01 inside and 02 outside duly marked, Wall/structure with suitable mounting will be provided by the manufacturer of the AC, Noise indoor 50 db, outdoor 90 db, warranty period 12 months after installation and 18 months after supply . Certification CIMFR/PESO/BIS (Note:- All the accessories i.e. Copper tube, connecting lead, initial refrigerant gas required for connection of split AC unit and making suitable hole in wall for passing the pipe and making good as per existing and other parts required to installed and working of the AC deemed included in this item rate.)
Supply and install 2.0 TR 5 star rated inverter split air conditioner comprising of indoor & outdoor units, mounting arrangements, SEER 4.7, 100% inner grooved copper tube/condenser, stepless compressor control, working capacity for ambient temp upto 52 degree centigrade, filter clean indicator, refrigerant gas R-410 (a)/R-32, protection from power fluctuation from 160V to 255V, noise level <=37 db, white colour, manufacturer warranty two years on AC, 10 years on compressor, 5 years on controller/PCB complete all as specified and directed. Note :- Cost of copper tubing from outdoor unit to indoor unit and installation of AC is deemed to be included in the item rate.
M&L for removal of split AC 1.5 TR capacity from 01 location and installation to another location within Armoury premises to include complete indoor and outdoor units with all fixing arrangements and stand for outdoor unit including gas charging complete all as specified and directed.
M&L for disconnection LT cables from junction box of pole for PCC work and earth work in and around the pole in WSA area opening of cable loop and taking out the cable from trenches upto specified length of PCC as per site requirement and relaying the cable through protection pipe (Existing/new) in all aspect after satisfactory completion of earth work as specified and directed. (Note:- Preparation of sub base by using 20mm grade store upto 100mm depth is deemed include in the item earth work is measure separately)
M&L PCC 1:3:6 type C1 using 20mm graded stone aggregate for pedstal of pole/coping and fire break complete all as directed by Engrineer-in-Charge
M&L for writing of letter of size 30 x 8 cm “CABLE BENEATH THIS PCC” on the PCC floor by using road marking paint complete all as specified and directed.
Supply and Laying light grade galvanised steel tube 50mm bore for protection of cable complete all as direced by Engr-in-Charge
M&L for surface dressing/cleaning of surrounding area of pole including removing of tree branches, small trees plant bushes etc complete all as directed by Engir-In-Charge.
S&F HDPE 100mm dia 0.4 mpa for passing of cable
National Rewinding Works
M/S Tanisha Traders
Aggarwal brothers and company
AMBEY MAA CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .