Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.1 LAccepted-AOC | L-1 | Accepted-AOC lowest bidder for the work. | |
| 2 | L-2₹9.9 L+₹3.4 L (52.3%)Rejected-Finance | L-2 | Rejected-Finance other than the lowest bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical CONDITIONS NOT COMPILED |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
26 Nov 2022, 6:00 pmClosed
Commander Works Engineer Bhopal
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
REPAIR AND MAINTENANCE OF HT CABLES, OVERHEAD LINES AND ALLIED WORKS UNDER EXTERNAL ELECTRIFICATION AT BAIRAGARH UNDER GE BHOPAL
2022_MES_561802_1
83773/E8
Open Tender
Civil Works
Item Rate
180 days
Bhopal
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
GE Bhopal
₹20,000
Yes
24 Jan 2023
7 Nov 2022
28 Nov 2022
7 Nov 2022
26 Nov 2022
13 Nov 2022
7 Nov 2022 - 13 Nov 2022
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
Supply & laying unreinforced precast concrete cable cover class HVP type 2, with peak shape, dimension 450 mm X 180 mm X 40 mm and 65 mm peak thickness as per IS 5820: 1970 complete all as specified and as directed.
Disconnecting, taking out old unserviceable under ground cable of rated voltage 19 kV/ 33 kV, upto any size of nominal cross sectional area of main conductor, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for reuse or for taking credit all as specified and directed by the Engineer-in-Charge.
Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 19 kV/ 33 kV, three phase, earthed system, 3 core, screened, armoured power cable, 185 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing complete all as specified and as directed.
Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 19 kV/ 33 kV, three phase, earthed system, 3 core, screened, armoured power cable, 95 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing complete all as specified and as directed.
S & F XLPE cable end termination, cold shrinkable, outdoor type, suitable for voltage 19 kV/ 33 kV (Earthed), 3 core, 120 sqmm to 185 sqmm complete all as specified and as directed.
Supplying & laying including taking down in trenches, in road cutting and along pole 150 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Dismantling danger notice plate any type and size and setting aside for re-use or removing to store or for schedule of credit
M & L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT, 250 mm X 200 mm complete all as specified and as directed.
Supply and fix in repairs metal oxide surge arrester without gap for AC system as per IEC 60099-4: 2014, outdoor type, polymer housing, single column and single phase construction, station class, medium duty, nominal discharge current 10 kA, switching impulse discharge current 1 kA, repetitive charge transfer rating (Qrs) more than 1.6 C, thermal energy rating (Wth) more than 7 kJ/kV, nominal system voltage 33 kV, highest system voltage 36 kV, rated voltage of arrester 27 kV, continuous operating voltage 21.6 kV, temporary overvoltage (30.45 kV for 1 s, 28.50 kV for 10 s, 26.35 kV for 100 s), rated short circuit current 20 kA, low short circuit current 600 A, insulation withstand level (lightning impulse voltage 1.2/ 50 µs) 170 kV, lightning impulse residual voltage (8/20 µs) at nominal discharge current maximum 70 kV, switching impulse residual voltage (30/60 µs) at switching impulse discharge current maximum 57 kV, high current impulse withstand capability (4/10 µs) 100 kA, minimum creepage distance 900 mm complete all as specified and as directed.
Supply and fix in repairs DO fuse assembly, suitable for horizontal and vertical operation, triple pole mounted on polymer HT insulator 6 Nos and mild steel galvanised steel frame rating upto 200 Amp, 33 kV complete with DO fuse and electrical connections, jumpering by ACSR conductor and connectors complete all as specified and as directed.
S & F in repairs gang operated air break switch as per IEC 62271-103 amended upto date, rocking/ tilting type, suitable for both horizontal and vertical mounting, three poles, outdoor type, nominal system voltage 33 kV, rated voltage 36 kV, rated frequency 50 Hz, continuous current rating 400 Amps, rated short time withstand current for three seconds 25 kA, rated peak withstand current for three seconds 62.5 kA, rated lightning impulse withstand voltage (i) to earth and between poles 170 kV (Peak) (ii) across the isolating distance 195 kV (Peak), power frequency withstand voltage between (i) earth & poles 70 kV (rms) (ii) across the isolating distance 80 kV (rms), minimum isolating distance in open position 520 mm, phase to phase clearance 1220 mm, minimum cross sectional area of fixed contact 300 sqmm, minimum cross sectional area of moving contact 250 sqmm, copper connector having minimum cross sectional area of 250 sqm, maximum current density of 1.6 Amps/ sqmm for all current carrying parts, single number of brake per phase, medium grade galvanised iron pipe of 32 mm nominal bore and 5 to 6 metre length in single piece for operating pipe, pad-locking in both ‘on’ and ‘off’ position with indicators, electroplated nonferrous parts, hot dip galvanised ferrous parts, 3 Nos polymer post insulator per phase as per IEC 61109 amended upto date having rated voltage 36 kV, minimum creepage distance 900 mm, impulse withstand voltage 170 kV, wet power frequency withstand voltage 75 kV, dry wet power frequency withstand voltage 75 kV complete all as specified and as directed.
M& L for servicing of 33 kV gang operated air break switch, any type (horizontal or vertical) by cleaning the contact, greasing, applying petroleum jelly at the contact point, checking serviceability and including replacement of heavy duty brass jaw and blade set, copper strip set, lugs, nuts, bolts, washers, aluminium thimbles, jumpers, all as per the existing complete all as specified and as directed. Note: - (1) The cost for replacement of brass jaw, blade set, copper strip set, lugs, nuts, bolts, washers, aluminium thimbles, jumpers, lubricating materials, etc. shall be deemed to be included in the unit rate quoted by the contractor for the item.
Supply only male contact /moving contact blade for gang operated air break switch (Set of three)
Supply only female contact/fixed contact jaw for gang operated air break switch (Set of three)
Copper tinned striped 11 kV, 200 Amps (Set of three)
Dismantling insulators any type, any size complete all as specified and as directed.
S & F 33 kV polymeric composite pin insulator, conforming to IEC 61109, material of core (FRP rod): borron free ECR, material of sheds: silicon rubber, material of top end fittings: spheroidal graphite cast iron, malleable cast iron or forged steel, material of bottom end fittings: forged steel, sealing compound for end fitting: RTV Silicon, colour of sheds: grey, rated voltage: 33 kV, highest voltage: 36 kV, dry power frequency withstand voltage: 95 kV, wet power frequency withstand voltage: 75 kV, dry power frequency flashover voltage: 130 kV, wet power frequency flashover voltage: 90 kV, dry lightning impulse withstand voltage: (a) Positive: 170 kV, (b) Negative: 180 kV, dry lightning impulse flashover voltage: (a) Positive: 210 kV, (b) Negative: 230 kV, RIV at 1 MHz when energised at 10 kV / 30 kV (rms) under dry condition < 70 microvolt, creepage distance (minium): 900 mm, minium failing load: 10 kN complete all as specified and as directed.
S & F porcelain line post insulator, Type B, Nominal System voltage 33 kV, highest system voltage 36 kV, visible discharge test voltage 27 kV, wet power frequency withstand voltage 75 kV, power frequency puncture withheld voltage 180 kV, impulse withstand voltage 170 kV, minimum total creepage distance 580 mm, minimum failing load 10 kN, of suitable size with galvanised steel stud pin, nut, washers complete all as specified and as directed.
S & F 33 kV polymeric composite disc insulator, conforming to IEC 61109, material of core (FRP rod): borron free ECR, material of sheds: silicon rubber, material of end fittings: spheroidal graphite cast iron, malleable cast iron or forged steel, sealing compound for end fitting: RTV Silicon, colour of sheds: grey, rated voltage: 33 kV, highest voltage: 36 kV, dry power frequency withstand voltage: 95 kV, wet power frequency withstand voltage: 75 kV, dry power frequency flashover voltage: 130 kV, wet power frequency flashover voltage: 90 kV, dry lightning impulse withstand voltage: (a) Positive: 170 kV, (b) Negative: 180 kV, dry lightning impulse flashover voltage: (a) Positive: 210 kV, (b) Negative: 230 kV, RIV at 1 MHz when energised at 10 kV / 30 kV (rms) under dry condition < 70 microvolt, creepage distance (minium): 900 mm, minium failing load: 70 kN complete all as specified and as directed.
Dismantling cross-arms of mild steel channel or angle sections etc. complete and setting aside for re-use or removing to store or for schedule of credit
Fixing only cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
M & L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
S & F in repairs earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 mm X 6 mm galvanised mild steel strip complete all as specified and as directed.
M & L for preparation and painting of power grid bus bar structure at MAIN 33 kV MRS at 3 EME centre comprising tubular poles 9 metre to 13 metre long (29 Nos), mild steel beams, channels, clamps, bracing angles, cross arms, DO switches (8 Sets), AB Switches (12 Sets), VCBs (8 Nos), CTs (14 Nos), PTs (14 Nos), mounting stands, etc. with scratching out old bubbled paint, finishing the surface complete all as specified and as directed comprising the following: - (a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on steel poles (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 on steel poles (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions.
M & L for preparation and painting of power grid bus bar structure at MAIN 33 kV MRS at MH substation comprising tubular poles 9 metre to 13 metre long (14 Nos), mild steel beams, channels, clamps, bracing angles, cross arms, DO switches (2 Sets), AB Switches (5 Sets), VCBs (2 Nos), CTs (6 Nos), PTs (6 Nos), mounting stands, etc. with scratching out old bubbled paint, finishing the surface complete all as specified and as directed comprising the following: - (a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on steel poles (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 on steel poles (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions.
M & L for preparing and painting on two poles structure of steel tubular swaged of any type and any length including cross arms, GI brackets, PCC coping complete all as specified and as directed comprising the following: - (a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions.
M & L for preparing and painting on four poles structure of steel tubular swaged of any type and any length including cross arms, GI brackets, PCC coping complete all as specified and as directed comprising the following: - (a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions.
M & L for preparing and painting on two poles structure of prestressed concrete pole of any type and any length including cross arms, GI brackets, PCC coping complete all as specified and as directed comprising the following: - (a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of premium acrylic smooth exterior paint (100% acrylic) with silicone additives in two or more coats, that offers an anti-algal, excellent resistance to ultraviolet radiation, dirt pick up resistance (DPUR) property, rich sheen, low VOC, of approved shade over a coat of primer as per the manufacturer’s instructions.
M & L for preparing and painting on four poles structure of prestressed concrete pole of any type and any length including cross arms, GI brackets, PCC coping complete all as specified and as directed comprising the following: - (a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of premium acrylic smooth exterior paint (100% acrylic) with silicone additives in two or more coats, that offers an anti-algal, excellent resistance to ultraviolet radiation, dirt pick up resistance (DPUR) property, rich sheen, low VOC, of approved shade over a coat of primer as per the manufacturer’s instructions.
M & L for preparing and painting on steel tubular swaged pole 410 SP-72 (13.00 metre long) including cross arms, GI brackets, PCC coping complete all as specified and as directed comprising the following: - (a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer © Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. € Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions.
M & L for preparing and painting on prestressed concrete pole, 11.00 metres long including cross arms, GI brackets, PCC coping complete all as specified and as directed comprising the following: - (a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of premium acrylic smooth exterior paint (100% acrylic) with silicone additives in two or more coats, that offers an anti-algal, excellent resistance to ultraviolet radiation, dirt pick up resistance (DPUR) property, rich sheen, low VOC, of approved shade over a coat of primer as per the manufacturer’s instructions.
M & L for loose filling with broken stone or boulder aggregates of gauge 40 to 80 mm in soakage pits, soakage wells, on open space etc. complete all as specified and as directed.
M & L for trimming of branches of trees touching HT/LT Electric over head line and making clear about 3 m in radius and carrying and disposal where directed not exceeding 50 m complete all as directed. Note :- Vehicle and othe T&P shall be arranged by the contractor at own cost.
Dismantling steel poles/ struts, any size, transporting to store and stacking or for schedule of credit
M & L for steel tubular swaged pole 410 SP-72 (13.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including preparing and painting on steel tubular swaged pole 410 SP-22 (8.50 metre long) including cross arms, GI brackets, PCC coping complete all as specified and as directed comprising the following: - (a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions
M & L for steel tubular swaged pole 410 SP-55 (11.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including preparing and painting on steel tubular swaged pole 410 SP-22 (8.50 metre long) including cross arms, GI brackets, PCC coping complete all as specified and as directed comprising the following: - (a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed.
M & L for dismantling of overhead ACSR (aluminium conductor galvanized steel-reinforced) or galvanised mild steel wire of any size and any type from pole, lowering down to facilitate tree cutting or trimming and refixing and stringing ACSR (aluminium conductor galvanized steel-reinforced) and galvanised mild steel wire of any size and any type and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed. Note 1: Each line shall be measured and paid separately. Note 2: Tree cutting shall be measured and paid separately.
Restringing only galvanised iron wire of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
Dismantling ACSR or AAC conductors removing to store or taken on schedule of credit complete all as specified and as directed.
Supply, fixing and stringing ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
S & F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised mild steel wire complete all as specified and as directed.
M & L in repair for disconnecting and taking out worn out jumpers of HT / LT overhead line at cut point/ at two pole/ four pole structure of any size any length as per existing after removing binding wire connector of AB switch/DO fuse unit, replacement of old jumper with the new ACSR conductor (Mink/ Dog conductor as directed by Engineer-in-Charge) Jumpers Including PVC sleeve in colour coding R/Y/B of same size and length including new binding wire connectors suitable for AB switch/DO fuse unit, with providing conducting jelly complete all as specified and as directed. (Note: -Each Jumper to be measured separately)
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in road cutting complete all as specified and as directed.
M & L for making road cutting surfaces good using 200 mm thick hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface and using cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 150 mm thick finished even and fair and using earth filling for remaining depth complete all as specified and as directed.
Supplying & laying including taking down in trenches, in road cutting and along pole 100 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Dismantling stay assembly complete (Note: Demolition of concrete, etc. and excavation measured shall be measured and paid separately separately.)
M & L for stay assembly of stay rod of diameter 20 mm complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and as directed.
M & L for hot dip galvanized stay strands of grade I, 7 Nos wires construction, wire diameter 3.15 mm, nominal strand diameter 9.45 mm, heavy zinc coating complete all as specified and as directed.
M & L for loop type insulator (porcelain guy strain insulator), large size, with overall dimensions 140 mm X 85 mm, cable hole dia 25 mm, creepage distance 57 mm, minimum failing load 88000 N, vitreous porcelain, white, brown or green, Designation C as per IS 5300: 1969 complete all as specified and as directed.
M/S RAKESH TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .