| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹3.3 L+₹25,996 (8.67%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC other than lowest bidder | |
| 3 | L3₹3.7 L+₹73,517 (24.5%)Rejected-AOC | L3 | Rejected-AOC other than lowest bidder |
Tender Value
₹4.5 L
EMD Value
₹9,000
Closing Date
14 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I CG
Noida
AGE I CGN 27 20 21 REPAIR MAINTENANCE TO ESSENTIAL EM SERVICES AT SECTOR 62 NOIDA
2020_MES_377110_1
AGE I CGN 27 20 21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Noida
E b i
7 documents required · 7 mandatory
₹300
AGE I CG
₹9,000
6 May 2021
15 Sept 2020
16 Oct 2020
15 Sept 2020
14 Oct 2020
30 Sept 2020
60 days
Amount
Taking down carefully copper/aluminium point wiring (light, fan,socket or power) complete, (fitting such as switches ,ceiling roses, pendants, regulators, sockets etc. to be measured separetely ) removing materials to store for keeping the safe custody or for taking credit and making good distrubed surface of walls, floors etc.
Point wiring with multistranded copper conductor PVC Insulated and un sheathed cable in PVC Casing and caping 1.5 SQMM with all fittings /accessories and including 1 Sqmm PVC insulated copper earth wire connected common earth including sunk type pressed steel terminal box mounting switches ,sockets etc with 3mm thick laminated sheet cover for one light/ Fan point or bell /buzer point independant controlled by one switch complete .
All description as per srl item No 2 here- in- before but for one three pin socket outlet 5 Amps switch socket outlet on same board.
All description as per srl item No 2 here- in- before but for one three pin socket outlet 5 Amps switch socket outlet on Independant board.
All description as per srl item No 2 here- in- before but using cable size 4 Sqmm for one three pin switch socket outlet 15 Amps on Independant board all as specified.
S&F in repair Switch piano flush button single pole one way 5 Amps.
S&F in repair socket outlet 2 in 1 and 3 and 2 pin 5 amps flush type.
S&F in repair Switch piano flush button single pole one way 15 Amps.
S&F in repair socket outlet 5/15 Amps flush type multi purpose.
S&F in repair modular switch one way 6 A .
S&F in repair socket outlet 2 in 1 and 3 and 2 pin 5 amps modular type 2 module .
S&F in repair modular switch one way 16 A .
S&F in repair socket outlet 2 in 1 and 5 pin and 16 Amps modular type 2 module.
S&F in repair Modular fan regulator 2 module .
S&F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet, etc. as required
S&F in repair ceiling rose surface backlite 65mmx50mm two to three terminals.
S&F in repair CFL bulb 11 Watt 230 Volt pin type .
S&F in repair CFL bulb 18 Watt 230 Volt pin type .
Fixing only any type of tube light fitting including connecting up with twin core twisted flexible copper conductor cable with suitable size.( Tube lights will be issued by Deptt as Sch B )
S&F in repair Flourascent Lamp 14 Watt T5 .
S&F in repair LED surface panel light fitting round/square shape fitting 1X6 Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size,
Supply and replacement of energy saving tube rod T-5 ,28 Watt, 4 pin slim type with advanced tri phosphorous layer warm white.
S&F in repair Metel halide bulb 150 Watt suitable for high bay light fitting.
S&F in repair copper ballast suitable for 150 Watt high bay metel halide light .
S&F in repair ignitor suitable for 150 Watt MH light.
S&F in repair Capacitor suitable for 150 Watt MH light .
S&F in repair Metel halide bulb 70 Watt suitable for high bay light fitting.
S&F in repair copper ballast suitable for 70 Watt high bay metel halide light.
S&F in repair ignitor suitable for 70 Watt MH light .
S&F in repair Capacitor suitable for 70 Watt MH light .
S&F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp.
S&F in repair MCB TP 63 Amps, 240 volts .
S&F in repair MCB TP 40 Amps, 240 volts.
S&F in repair MCB SP 5 to 32 Amps, 240 volts, 10KA .
Taking down unserviceable / burnt ceiling fan from position after disconnecting electrical connections , rewinding with suitable guage copper wire ,servicing and replacing bearings ,bushes etc complete for satisfactory running condition including refitting in position ,all as specified and directed by Engr in charge .
S&F in repair capacitor for ceiling fan 2.5 MFD 230 V AC.
S&F in repair copper wound motor for Exhaust fan 300 MM sweep single phase AC .
Taking down carefully sub main wiring/service connections including aluminium/ GI earth continuity conductor of any size and type and making good disturbed surface all as directed .
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in PVC conduit with 2X4 Sqmm + 1X4 Sqmm as earth wire.
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in PVC conduit with 2X6 Sqmm + 1X6 Sqmm as earth wire.
S&F in repair Single phase fan motor for Desert cooler .
S&F in repair Single phase submersible pump for Desert cooler .
S&F in repair digital timer switches 110V-240V AC .
S&F in repair 4 pole power contacter Type 40A rating Make L&T Model MCX04 or equivalent.
S&F in repair thermal overload relay direct mounting on contactors Model TA25DU11M or equivalent.
S&F in repair single phasing preventer ,Auto reset,50 Volts unbalance Model VSP 3 or equivalent.
S&F in repair Auxillary contact block ,front mounted single pole add on blocks Model CA5-10 or equivalent.
S&F in repair Auxillary contact block ,front mounted single pole add on blocks Model CA5-01 or equivalent.
S&F in repair 3 pole contactor AC operated 12 A rating Model AX12-30-10 or equivalent.
S&F in repair on delay timer single range-240V AC Make Selec or equivalent .
Taking down carefully by unscrewing 01X150 Watt Metal Halide light fittings from 11 M high trusses and keeping safe custody for reuse at different location of trusses.
Refixing serviceable 1X150 Watt Metel Halide light fitting complete on trusses at a height of 11 Mtrs.
Material and labour for bracings, supports, clamps fabricated from structural steel sections to be used to mount the metal halide light fittings including nuts, bolts, washers, welding, bending colt or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint.
M/S ANIL KUMAR
BLUE HILL ELECTRICAL AND ELECTRONICS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .