Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC CHENNAI | L1 | Accepted-AOC Accepted | |
| 2 | L2₹20.6 L+₹2.9 L (16.2%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | L2 | Rejected-Finance Being Not Lowest Tenderer |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
24 Jan 2022, 6:00 pmClosed
Garrison Engineer Wellington, Barracks Post, The N
Garrison Engineer Wellington, Barracks Post, The Nilgiris.
PROVISION OF CERTAIN ADDITION/ ALTERATION/ IMPROVEMENT TO TRANSIT ACCOMMODATION AT PHASE II DAD QUARTERS, SINGARATHOPPU UNDER GE WELLINGTON
2021_MES_488115_2
8675/E8
Open Tender
Civil Works
Item Rate
180 days
GE Wellington
As per tender document
4 documents required · 4 mandatory
₹500
GE Wellington
₹30,000
Yes
16 Feb 2022
27 Dec 2021
25 Jan 2022
27 Dec 2021
24 Jan 2022
28 Dec 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed.
Taking down door/ window/ ventilator chowkat or frame with shutter (without taking of shutters from the frames) area not exceeding 1.5 Sq mtr each all as specified and directed.
Taking down door/ window/ ventilator chowkat or frame with shutter (without taking off shutters from the frames) area exceeding 1.5 Sq mtr but not exceeding 4 Sq mtr each all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) all as specified and directed.
Demolition of Brickwork, stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc ,complete all as specified and as directed.
Cutting out bricks, forming toothing for, and bonding new into old work including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old only) in cement mortar all as specified and as directed.
Excavation in trenches in any type of soil not exceeding 1.5 M wide and not exceeding 1.5M in depth for foundation etc and getting out all as specified and directed.
Plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1, 1:2:4 using 20 mm graded stone aggregate as in foundations, including rafts, footing, foundations, beams, plinth beams, bases for columns, etc., basement slabs, under reamed piles and mass concrete etc complete all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1, 1:2:4, using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1 1:2:4 (using 20mm graded stone aggregate) for beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roof, landing, deck slab and in shelves and the like all as specified and directed
Use and waste of formwork to sides of concrete foundations, footings, base of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter flat surface rough finished complete all as specified and directed.
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. Fair finished surfaces of concrete flat complete all as speicified and directed.
Use and waste of Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for fair finished flat surface of concrete complete all as specified and directed
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surface of concrete complete all as specified and directed.
Mild steel TMT bars 10mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality,complete all as specified and as directed.
Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, complete all as specified and directed
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Demolition of Concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) all as specified and directed.
Vitrified coloured ceramic tiles dark shade 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement slurry to match over and including 15mm thick screed in cement mortar (1:6) complete all as specified and directed.
Vitrified coloured ceramic tiles dark shade 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in vertical surfaces such as skirting, dados and riser to steps etc, and jointed in neat cement slurry and pointed in white or coloured cement slurry to match over and including 10mm thick screed in cement mortar (1:6) backing coat complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base to flooring 75mm thick all as specified and directed.
25mm thick Plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in floor all as specified and directed.
Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match the surface and including 15mm thick screed bed or bedding layer of mortar in cement mortar 1:4 complete all as specified and as directed.
Coloured Glazed ceramic tiles in vertical surfaces 300mm x600mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plaster in cement mortar 1:3 complete all as specified and as directed.
Hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and directed.
Rendering 15mm thick in cement mortar 1:6 on surface other than fair faces of brick work or concrete surfaces or stone masonary surface, finished even and smooth without using extra cement all as specified and directed
Rendering 15mm thick in cement mortar 1:4 on fair face of concrete or brick or stone surfaces, finished even and smooth without using extra cement mixed with WPC as per manufacturer's instructions all as specified and directed. Note: WPC will be measured and paid separately.
Rendering 5mm thick in cement mortar 1:4 as in ceiling surfaces including finishing the surfaces even and smooth complete all as specified and directed.
Rendering 10mm thick in cement mortar 1:4 on fair face of concrete surfaces, finished even and smooth without using extra cement all as specified and directed.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc ad making good cutting exceeding 20cm grith all as specified and directed.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc ad making good cutting exceeding 10cm but not exceeding 20cm grith all as specified and directed.
Cutting holes into or through cement concrete slabs, chajjas etc, reinforced or otherwise not exceeding 100 sq cm all as specified and directed.
Cutting holes not exceeding 150Sqcm into or through brick walls built in cement mortar or cement lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-I as required all as specified and directed.
75mm dia PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement complete all as specified and directed.
PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints laid in trenches or in floors all as specified and as directed.
PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and directed.
PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed.
PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed to walls all as specified and directed.
PVC (SWR) bend of any radius 110 mm dia complete all as specified and as directed.
PVC (SWR) bend of any radius 75 mm dia complete all as specified and as directed.
PVC (SWR) bend of any radius 110 mm dia with access door complete all as specified and as directed.
PVC (SWR) bend of any radius 75 mm dia with access door complete all as specified and as directed.
PVC (SWR) branch piece single, (single Y) equal or un equal of 110mm bore of pipe of any radius with acess door complete all as specified and directed
PVC (SWR) branch piece single, (single Y) equal or un equal of 75mm bore of pipe of any radius with acess door complete all as specified and directed
PVC (SWR) vent cowl 75mm dia bore of pipe complete all as specified and directed.
PVC (SWR) vent cowl 110mm dia bore of pipe complete all as specified and directed.
GI tubing 15mm bore steel tubes medium grade with all fittings and fixed complete to stone walls/ brick walls/ ceilings or laid in floors complete all as specified and directed.
GI tubing 20mm bore steel tubes medium grade with all fittings and fixed complete to stone walls/ brick walls/ ceilings or laid in floors complete all as specified and directed.
Chroumium plated fancy type long body 2 in 1 bib tap fixed with existing pipe and fixed in repairs all as specified and as directed. Make : KUP-35041 PM of JAQUAR or equivalent
Single lever CP wall mixer 3 in one system with provision for both hand shower and overhead shower complete with 115mm long bend pipe connection legs and wall flange all as specified and as directed. Make: CAT No KUP-35125PM of Jaquar or equivalent
Supply and fix soap dish complete all as specified and directed. Make : Cat No ACN-1131N of JAQUAR or equivalent
Supply and fix towel rack 600mm long with lower hangers as in bathroom complete all as specified and directed. Make: Cat No AKP-35781P of JAQUAR or equivalent
Supply and fix CP toilet paper roll holder with flap complete all as specified and directed. Make: Cat No AKP 35753 of JAQUAR or equivalent
Supply and fix single towel rail 600mm long complete all as specified and directed. Make: Cat No AKP-35711P of JAQUAR or equivalent
Supply and fix towel ring square/ rectangular with round flange complete all as specified and directed. Make: Cat No ACN 1121N or ACN-1121BN of JAQUAR or equivalent
Supply and fix shower basket small complete all as specified and directed. Make: Cat No ACN 1177N of JAQUAR or equivalent
Supply and fix hand shower (health faucet) with 8mm dia, 1m long flexible tube and wall hook with back flow preventer complete all as specified and directed. Make: Cat No ALD-577 of JAQUAR or equivalent
Supply and fix over head shower rose 200mm x 200mm square shape single flow(body and face plate stainless steel with chrome finish) with rubit cleaning system complete all as specified and directed. Make: Cat No OHS-CHR-1619 of JAQUAR or equivalent
Chroumium plated shower arm square shape 60mm long complete all as specified and directed. Make: JAQUAR or equivalent
PVC connections 15mm size of length 450mm with PTMT nuts all as specified and directed.
CP Gratings 125mm dia with / without waste hole, complete all as specified and directed.
Bib tap fancy type long body chromium plated with letters hot & cold fixed 15mm dia complete all as specified and directed. Make: JAQUAR or equivalent
Angular stop cock with wall flange for 15mm dia of chorumium plated fancy type in repairs complete all as specified and directed. Make: Cat No KUP-35053PM of JAQUAR or equivalent.
Table top basin of size 485x395x150mm including waste coupling and waste pipe complete all as specified and directed. Make: Cat No JDS-WHT-25909 of JAQUAR or equivalent
Pedestal pan water closet of size 755X365X655 mm inluding flushing cistern,seat cover etc complete all as specified and as directed. Make: Cat No.LYS-WHT-0204 & ZPS-WHT-10270K of JAQUAR or Equivalent.
Granite 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 15mm thick screed in cement mortar 1:4 all as specified and directed.
Rounding edges of stone slabs one edge such as steps, cooking platforms and other similar situation, complete all as specified and directed.
Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories and E50 stainless steel dash fasteners, stainless steel bolts etc, of required size in the top of floor or the side of waist slab with suitable arrangement all as specified and directed.
First class hardwood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered put together with glue pinned at joints supplied and fixed all as specified and as directed.
35 mm thick flush shutter, solid core construction, with Particle Board Core and plywood face panels covered with decorative Face Veneer with lipping/ frame on one faces, complete all as specified and as directed.
30mm thick factory made solid core, single leaf PVC Moulded door shutter 28 to 30mm thick (stiles) but 2mm thick 3D wood grain moulded PVC sheet polyurethene painted on front face and 2mm prelaminated PVC sheet on back face with 2, 4 or 6 raised panel design, supplying and fixing in frame at site as per specification and drawing and all as specified and as directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm wood grain printed PVC sheet and edges will be painted to match with printed sheet, reinforced with M.S square tube all as specified and as directed.
Mild steel work as in hold fast ec confirming to FE-290 Gde E 165 complete all as specified and as directed.
Plain cement concrete type C1, 1:3:6 using 20mm graded stone aggregate as in bed blocks for hold fast, and including necessary form work all as specified and directed.
Brass Butt hinges extruded brass 125 mm size, type B11 all as specified and as directed.
Brass barrel tower bolt of 200mm size with barrel of extruded section and fixed complete all as specified and as directed.
150mm long extruded brass handles, fabricated type, polished complete all as specified and directed.
300mm brass sliding door bolt with sand or die cast brass hasp staple bolt type and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed.
Floor door stopper of brass body and tongue, with hard drawn steel spring fixed in floor over all length 150mm all as specified and directed.
Butt hinges, 100 mm size medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
200 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section 150 mm long all as specified and directed.
Aluminium handles, cast type anodised, extruded section 150 mm long all as specified and directed.
Supply and Fix UPVC ventilator frame shall be made of PVC material confirming to IS-10151 the ventilator frame of extruded UPVC section having overall dimensions of 100mmx62mmx50mm having wall thickness 2mm+- 0.2mm. Corners of wall frame shall be joined by MS galvanised brackets joints mitred and plastic welded. The hinge side vertical outer frame shall be reinforced with galvanised MS tube of wall thickness 1mm +/- 0.1mm and the tie rod shall be provide at the bottom of the frame all as specified and directed. Glazing (1) : The ventilator system should be glazed with 5.5mm thick glass of size as required in ventilatior frame (louvered type) as per manufacturer instructions including all fittings and necessary locking arrangements complete all as specified and directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash over wall care putty in two layers complete all as specified and directed. Note: Putty to be measured and paid seperately.
Preparation of old decorated surfaces of ceiling, cornices etc by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss and efflorescent salts, treating oil and greasy spots, etc., and applying two coat of white wash over wall care putty in two layers complete all as specified and as directed. Note: Putty to be measured and paid seperately.
Preparation of new plastered surfaces of wall and applying two coats of plastic emulsion paint on new surfaces over a coat of primer on walls over wall care putty in two layers complete all as specified and as directed. Note: Putty to be measured and paid seperately.
Complete removal of existing treatment of old plastered surface of wall and applying two coats of plastic emulsion paint over primer, over one coat in two layers of wall care putty 2-3mm thick including sanding and preparation of surface to a true, even and smooth complete all specified and directed. Note: Putty will be measured and paid separately.
Complete removal of existing treatment of old plastered surface of wall and applying two coats of weather proof exterior emulsion (Anti fungal) paint over a coat of primer, complete all specified and directed.
Applying 2mm thick wall care putty in two layers over plastered surfaces to prepare the surface even and smooth on wall all as specified and directed.
Demolition of RCC of Roof, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as specified and directed.
75mm thick plain Cement concrete type C-1 , 1:3:6, using 20 mm graded stone aggregate as in plinth protection / path complete all as specified and directed.
Demolition of cement Concrete of any description and in any position including padding concrete all as specified and directed.
50mm thick PCC 1:2:4 type B0 using 12.5mm graded stone aggregates average as in levelling / padding course on roof slab, projections on similar surfaces existing with slope, making the surface even and smooth without using extra cement, including using liquid water proofing compound all as specified and directed. Note: Supply of integral water proofing compound will be measured and paid seperately.
Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 laid over the RCC roof slab, parapet wall when the concrete is green at any height and making the surface fair and even without using extra cement including using liquid integral WPC as per manufacturer instructions complete all as specified and directed. Note: Supply of integral water proofing compound will be measured and paid seperately.
Supply only liquid water proofing compound all as specified and directed.
Applying 03 coats of Dr FIXIT NEW COAT, heavy duty Acrylic polymer based water proofing coating with integral micro fiber reinforcement over 1 coat of prime coat of Dr FIXIT PRIME SEAL over roof slab/ chajjas/ wall. Application and surface preparation to be strictly followed as per the manufacturer instruction including cleaning surfaces, coving the prepared substrate at junctions using polymer mortar to fill in the cracks opended up in V grooves complete all as specified and directed. Note: 1. Make:- Dr. Fixit or equivalent as approved by GE. 2. Work shall be carried out through manufacturer's applicators only.
Point wiring complete with 1.5 sqmm (nominal area) FRLS grade PVC insulated, unsheathed stranded copper conductor single core cable 1100 volts grade in and including PVC conduit medium grade complete with conduit fittings/accessories with provn of 1.2 mm thick MS terminal boxes of suitable size and 3 mm thick plastic laminated sheet top cover for housing of switches, sockets etc including 1.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor and connected to common earth dolly for One light/Ex-fan point controlled by one switch 5Amps SP all as specified and directed.
All as per Item No 105 hereinbefore but One 5A 2 pin / 3 pin switch socket outlet multipurpose on independent Board all as specified and directed.
All as per Item No 105 hereinbefore but point wiring complete with 2.5 sqmm for 3 pin 5/15 A socket outlet on independent board including 2.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor all as specified and directed.
Modular switch one way 6A 230V AC 50 HZ SP one module all as specified and directed.
Modular socket 2/3 pin combined 6A 230V AC 50 HZ SP two module all as specified and directed.
Modular socket 6A/16A 2/3 pin combined 230V AC 50 HZ SP two module all as specified and directed.
Modular switch one way 16A 230V AC 50 HZ SP one module all as specified and directed.
Ceiling rose, 3 terminals PVC/ polycarbonate, isolated body all as specified and directed.
Frame plate with white cover, two module plate all as specified and directed.
Frame plate with white cover, three module plate all as specified and directed.
Frame plate with white cover, four module plate all as specified and directed.
Frame plate with white cover, six module plate all as specified and directed.
LED light fittings 1x20W, 220V, AC decorative box type with driver holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
LED light fitting 1x10W bulkhead luminaires inluding LED light driver holder connection up with three core flexible copper conductor cable of suitable size all as specified and directed.
LED light fittings mirror type with high out put diffuser 2 feet, 10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Indoor hanging light fitting 18W, 220V AC decorative fancy type with driver, holder including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make: Luker product code LHL202.
Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage shutter, voltage 230V, 50HZ, RPM 1200, copper winding of sweep 250mm including making opening brick / stone masonary wall as per requirement of exhuast fan and make good and matching with existing surfaces complete all as specified and directed. Make: Crompton Creaves/ Havells / Bajaj
Miniature circuit board (MCB) 240V, 10KA 'B' of single poles and current carrying capcity 20 AMP, in the MCB DB complete with connection testing and commissioning all as specified and directed.
All as per item No 10 hereinbefore but SPN 230V 32 Amps capacity all as specified and directed.
MCB DB SPN 8 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified and directed. Make: ABB / LEGRAND / L&T
Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 4 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 4 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings all as specified and directed.
Cutting existing GI pipes and insert to new GI pipe of any size all as specified and directed.
LED street light fittings 35 Watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earth testing point including necessary excavation, earth work, PCC pit ,RCC cover 1:2:4 type B1 with 8 mm dia MS bars at 100c/c , funnel ,watering pipe etc. all specified and directed including testing on completion.
Electric heater, storage type steel body with copper inner tank and heating elemant upto 2KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc all specified and directed
Bib tap cast copper alloy with chromium plated crutch or butterfly handle, screwed down, screwed for Galvanised iron pipe or for brass ferrule and fixed complete for 15mm bore GI pipe and all as specified and directed.
Stop valves 15mm bore cast copper alloy screwed down high pressure with crutch or butter fly handles screwed both ends for iron pipe or for union fixed complete all as specified and directed.
Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one 20amps SP MCB all as specified and directed
Sree Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .