GEMC-511687788100943
Awarded to Maya Battery & Electrical Works
₹5.1 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Exide Power Safe Plus 12V-65AH | Exide Power Safe Plus 12V-65AH | - | 108 NOS | ₹4,750 | 513,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.1 LQualified Make: EXIDE
Model: Exide Power Safe Plus 12V-65AH 3 JADULAL MULLICK ROAD KOLKATA KOLKATA WEST BENGAL 700006 | KOLKATA | WEST BENGAL | 700006 | Make: EXIDE
Model: Exide Power Safe Plus 12V-65AH | L1 | Qualified MSE, Category: General | |
| 2 | L2₹6.0 L+₹91,800 (17.9%)Qualified Make: AMARON QUANTA
Model: 12AL065 A 42 JAI AMBEY NAGAR TONK ROAD JAIPUR RAJASTHAN 302018 | JAIPUR | RAJASTHAN | 302018 | Make: AMARON QUANTA
Model: 12AL065 | L2 | Qualified MSE, Category: General | |
| 3 | L3₹6.3 L+₹1.2 L (23.2%)Qualified Make: HBL
Model: HBL Make Model OPTI 65 AH SMF Batteries - Electrolyte 5600 29 A 2ND PHASE OPP TO ASIAN PAINTS GODOWN PEENYA INDUSTRIAL AREA BANGALORE KARNATAKA 560058 | BENGALURU URBAN | KARNATAKA | 560058 | Make: HBL
Model: HBL Make Model OPTI 65 AH SMF Batteries - Electrolyte 5600 | L3 | Qualified | |
| 4 | Disqualified Make: Okaya
Model: OKAYA OB 65-12 12V 65AH SMF VRLA BATTERY FLAT NO G1 SY NO 122 P LOTUS BLOCK FORTUNE ICON ROAD NO 10 BANJARA HILLS HYDERABAD TELANGANA 500034 | HYDERABAD | TELANGANA | 500034 | Make: Okaya
Model: OKAYA OB 65-12 12V 65AH SMF VRLA BATTERY | - | Disqualified MSE, Category: General | |
| 5 | Disqualified Make: ARTHEON
Model: 12V65AH SMF LEAD ACID BATTERY | Make: ARTHEON
Model: 12V65AH SMF LEAD ACID BATTERY | - | Disqualified Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
5 Oct 2018, 3:00 pmClosed
Average Turn Over of Last 3 Years 25 Lakh (s) Experience with Gov. Required 3 Year (s) Lead Acid Battery ( 108 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1
2 & 3) with latest amendments Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1
2 & 3) with latest amendments
Statinary Lead-Acid Batteries (with tubular positive plates) in Monobloc Container conforming to IS:13369/1992
Stationary cells and Batteries
Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991
Stationary Valve Regulated Lead Acid 1/3 Batteries conforming to IS:15549/2005
Lead- Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995
Lead- Acid Storage Batteries for Motor Vehicles conforming to IS:7372/1995 Nominal Voltage of Battery (volts) 12.0 Volt 2.0 Volt
6.0 Volt
12.0 Volt Material of container Polypropylene Hard Rubber
Fibre Reinforced Plastics (FRP)
Polypropylene
ABS Rated Capacity at C20 discharge (AH) 65 1-300 Warranty (Years) 2 Years 1 Year
2 Years
3 Years
4 Years
5 Years Battery Condition Dry Charged * CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications * Volume of Electrolyte (ml) 5600 * Weight of Dry Battery (Kg) shall be as per relevant IS: Specn.
corresponding Ah Yes. * No.of cells per Battery (No.) 6 Cells for 12 Volt battery * CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes * Address of the Lab BANGALORE * Name of the Lab CENTRAL POWER RESEARCH INSTITUTE * Test Report No. 630AEATDBT11S0164 * Test Report Date 12.04.2012 * Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. yes * 2/3 Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells
and for Batteries made from them for use in portable applications * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sheel Kumar Lohani 400099
Airports Authority Of India
ATS Complex
Sutar Pahadi Road
Sahar
Andheri ( E ) . 108 15
632731
GEM/2018/B/89809
GeM Contract
lead acid battery
GeM Contract
15 days
Maharashtra; Mumbai Suburban
PRODUCT
Awarded to Maya Battery & Electrical Works
₹5.1 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Exide Power Safe Plus 12V-65AH | Exide Power Safe Plus 12V-65AH | - | 108 NOS | ₹4,750 | 513,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Average Turn Over of Last 3 Years 25 Lakh (s) Experience with Gov. Required 3 Year (s) Lead Acid Battery ( 108 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1 | - | - | - |
| 2 & 3) with latest amendments Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1 | - | - | - |
| 2 & 3) with latest amendments | - | - | - |
| Statinary Lead-Acid Batteries (with tubular positive plates) in Monobloc Container conforming to IS:13369/1992 | - | - | - |
| Stationary cells and Batteries | - | - | - |
| Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 | - | - | - |
| Stationary Valve Regulated Lead Acid 1/3 Batteries conforming to IS:15549/2005 | - | - | - |
| Lead- Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 | - | - | - |
| Lead- Acid Storage Batteries for Motor Vehicles conforming to IS:7372/1995 Nominal Voltage of Battery (volts) 12.0 Volt 2.0 Volt | - | - | - |
| 6.0 Volt | - | - | - |
| 12.0 Volt Material of container Polypropylene Hard Rubber | - | - | - |
| Fibre Reinforced Plastics (FRP) | - | - | - |
| Polypropylene | - | - | - |
| ABS Rated Capacity at C20 discharge (AH) 65 1-300 Warranty (Years) 2 Years 1 Year | - | - | - |
| 2 Years | - | - | - |
| 3 Years | - | - | - |
| 4 Years | - | - | - |
| 5 Years Battery Condition Dry Charged * CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications * Volume of Electrolyte (ml) 5600 * Weight of Dry Battery (Kg) shall be as per relevant IS: Specn. | - | - | - |
| corresponding Ah Yes. * No.of cells per Battery (No.) 6 Cells for 12 Volt battery * CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes * Address of the Lab BANGALORE * Name of the Lab CENTRAL POWER RESEARCH INSTITUTE * Test Report No. 630AEATDBT11S0164 * Test Report Date 12.04.2012 * Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. yes * 2/3 Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells | - | - | - |
| and for Batteries made from them for use in portable applications * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sheel Kumar Lohani 400099 | - | - | - |
| Airports Authority Of India | - | - | - |
| ATS Complex | - | - | - |
| Sutar Pahadi Road | - | - | - |
| Sahar | - | - | - |
| Andheri ( E ) . 108 15 | - | - | - |
Exempted
5 Nov 2018
13 Oct 2018
contract_GEMC-511687788100943.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_632731.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .