Executive Engineer MID Anantnag hq Awantipora
MID Anantnag HQ Awantipora
Replacement of One motor for Lift Irrigation scheme Verinag
2026_IFC_309434_1
enit 05 of 2026-27
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
120 days
verinag
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
executive eingineer MID Anantnag
₹20,000
Executive Engineer MID Anantnag hq Awantipora
13 Jul 2026
6 May 2026
26 May 2026
6 May 2026
26 May 2026
6 May 2026
6 May 2026 - 11 May 2026
11 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design, Manufacture, Supply, Installation, Testing & Commissioning of Horizontal Centrifugal Pumping unit to be installed at the existing Lift Irrigation Scheme Verinag. The pumping unit shall have the following specifications: -
PUMP: -
Make Kirloskar, WPIL, M&P, Jyoti, SINTEH, Flowmore/or any equivalent make
Discharge = 2.5 Cusec (0.07079 m3/sec)
Dynamic Head = 56 m.
Speed = 1480 RPM
Type of pump = Horizontal Split Casing Centrifugal.
NPSH A at site = 3.60 m
MATERIAL OF CONSTRUCTION:
Impeller = Bronze grade V of IS: 318/ CF-8M
Wearing Ring = Bronze grade V of IS: 318/CF-8M
Impeller Shaft = Stainless Steel AISI 410
Gland = Bronze grade V of IS: 318
Fasteners = High tensile Steel
Shaft Sleeve = Stainless Steel AISI 410
Pump Casing = Close fine-grained Cast-Iron conforming to IS:210 Grade 20
Coupling = Tyre coupling of suitable size
Base frame =M. S fabricated as per IS 2062
Motor Specifications: -
Type---------------Horizontal Type Squirrel Cage Induction Motor
No of phases-------------------------03
Horse Power----------------------as per design but not less than 85 HP
Speed---------------------------------1480 RPM
Enclosure-----------------------------TEFC
Rated Voltage------------------------415 ±10%
Rated Frequency--------------------50±3%
Class of Insulation---------------------“F”
Temperature Rise------------ Limited to class B
Type of Duty--------------------------Continuous
Motor efficiency .......... ≥IE2
Make: KEC/ABB/Siemens/Bhel/Crompton/Marathon/Jyoti/Havells
The job includes coupling of the Motor with the Pump by way of providing and fitting of a suitable size tyre coupling with allied works and necessary modifications required, if any for fitment of the Pump Motor assembly to existing delivery and suction of diameter 150mm and 125mm respectively. The job includes costs on account of all duties, taxes, freight, transportation, transit insurance, handling, tools and tackles and consumables required for carrying out the said job and dismantling of old worn-out equipment. The Pumping unit shall have to be got predispatch inspection by the Third-Party Inspection Agency namely CEIL, RITES, NTH, TUV and the Certificate of the same shall be provided at the time of the supply of the equipment, for which the scope has been kept in the estimated cost.
Note: The pump curves of the quoted pumping equipment need to be uploaded by the tenderer at the time of tendering. The Govt. Circular of Finance Department issued vide No. DGAT/PS/DR/7865508/86 Dated: 06-03-2026 shall be applicable | - | job | 9,05,500 | - |
| 2 | Design, Manufacture, Providing, Fitting, testing and commissioning of 100 HP 3 Phase Fully Automatic Star Delta Motor Starter. The Star Delta Motor Starter panel shall be fabricated out of 1.6 mm (minimum) CRCA sheets and shall be Modular, free standing, floor mounted or wall mounted for indoor use having removable bottom gland plates for incoming and outgoing cables, dust and vermin proof (IP 55 protection) with Three Phase Aluminium Bus Bars, complete with connections, internal wiring and other accessories with painting etc as per the details furnished below: -
Rated voltage of the panel ------------------ 415±10%volts
Frequency ------------------------- 50 ±3Hz
No. of phases ----------------------- Three.
Distribution Bus Bar: -
Type ----- Electric Grade Aluminium insulated with Red, Blue, Yellow and Black Shrinkable Sleeves of adequate section.
Size ----- Adequate section as per requirement
Starters (FASD) 100 HP with minimum ratings as below:
Power specifications --- 3 phase 415±10 %& 50 ±3Hz
Contractors ------------ L&T/TC/BCH Make
Line contactors -------- as per design but not less than AC3 95 A
Star conductor --------- as per design but not less than AC3 80 A
Delta contractor ------- as per design but not less than AC3 95 A
Thermal over load relay ------- (66-110 A) or above as per requirement
Timer -------------- Star Delta Electronic
Protection: -
Overload &Under load protection
Single phase & Reverse phase protection
Unbalance voltage protection
Earth fault protection
Metering Display Details shall display Parameters: Phase Voltage, Phase Current, Line voltage etc
Accessories and wiring: -
a) Pushbuttons & elements: - Quantity: As per requirement such as for Starter start & Starter stop etc
b) Pilot Lamps: For Phase Indication, Motor ON/ OFF and Trip indication etc
NOTE: - The panel should be powder coated with Siemens grey colour. The Govt. Circular of Finance Department issued vide No. DGAT/PS/DR/7865508/86 Dated: 06-03-2026 shall be applicable | - | job | 94,500 | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.48 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.62 MB
BOQ_1001674.xls
BOQ • 0.32 MB
extension.pdf
PDF • 0.88 MB
C2.pdf
PDF • 0.93 MB
corigendum.pdf
PDF • 0.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .