Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹2.4 L
EMD Value
₹4,714
Closing Date
27 Nov 2026, 6:00 pm2d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EE(C), BSNL Civil Division, Bikaner
Executive Engineer (C),BSNL Civil Division, Main Telephone Buildng, Civil lines, ,Bikaner -334403
Maintenance and Tighting Of Ground Based Towers at Chunawad, adulsahar, Padampur and Karanpur in Sri Ganganagar OA
2026_BSNL_298176_1
26/EEC/BSNL-CIVIL/BKN/2026-27
Open Tender
Civil Works
Item Rate
60 days
SRIGANGANAGAR OA
PLEASE REFER TENDER DOCUMENTS
4 documents required · 4 mandatory
₹590
Account Officer (Cash), GMTD, BSNL, Bikaner
₹4,714
18 Nov 2026
18 Nov 2026
1 Dec 2026
18 Nov 2026
27 Nov 2026
18 Nov 2026
75 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. | |||||
| 1.1 | With cement mortar 1:4 (1cement: 4 coarse sand). | 8 | Sqm | - | - |
| 2 | Supplying at site hot-dipped galvanized steel members for tower to fix the same wherever found missing or replace any damaged / bent tower members all complete as per direction of Engineer-in-Charge. (The materials to be used for tower - members shall be galvanized M.S. of grade A as per IS: 2062 -1999 and IS: 808 -1989 and satisfy the relevant test as per IS codes. The fabrication shall be done in accordance with IS: 800-1984 and also in accordance with the approved drawings for the towers under maintenance. The galvanizing shall conform to IS: 4759 and 2629. The total mass of galvanizing coating shall not be less than 610 gms / Sqm i.e. 85 micron thickness) | 30 | Kg | - | - |
| 3 | Supplying at site hot-dipped galvanized M.S nuts, bolts, spring washers and plain washers of required size for fixing the same at the joints / junctions of tower wherever found required during maintenance of tower all complete as per the direction of Engineer-in-Charge. (The material for nuts, bolts shall be of grade 4.6 and as per 6639- 1972, IS: 1364 (Part I to V) -2002, IS: 1367 ( Part VIII) -1992, Plain washers as per IS: 6610-1972 and spring washers of type B as per IS:3063-1994, IS:1148-1982, IS:2015-1977). | 60 | Kg | - | - |
| 4Carrying out detailed and precise checking of all nuts and bolts, spring and plain washers provided at all the joints / junctions of base assembly , vertical legs members face bracings members, various members of working plateforms at diffrent levels etc., proper tightening of all the nuts with torque wrench of required size etc., complete including fixing of new hot dipped galvanised nuts , bolts , spring and plain washers etc., of various sizes where found missing / required including facilitating thedolote for checking the verticality of the tower masts. (The rates also include dismantling / dismembering of any deformed / bent / deshaped members which are required to be replaced of repaired. Payment for supplying hot dipped galvanised nuts , bolts , spring and plain washers, structural members etc shall be made seperately under relevent items) | |||||
| 4.1 | 40 M High Ground Based Tower. | 1 | No. | - | - |
| 4.2 | 60 M High Ground Based Tower. | 3 | Nos. | - | - |
| 5 | Supplying, installing, testing & comissioning of Single dome Aviation obstruction light (AOL) fixture having base made of aluminium die cast / fibre body and top cover of red polycarbonate dome & 230 V AC LED Aviation obstruction lamp with 300 & more Nos. clear LED's having light intensity of minimum 1200 LUX & necessary auto on-off scanner photo cell unit with tranformer in built in dome light of make from Vijay, Binoy, Altrox or equivalent etc. with necessary clamp for fixing arrangement etc. all complete as per the direction of Engineer-in-charge. | 3 | No. | - | - |
| 6 | Providing and fixing MCB of range 6-32 Amp of Havells, Merlin Gerin or equivalent make for Aviation obstruction light as per direction of Engineer-in-charge. | 3 | No. | - | - |
| 7 | Providing and fixing PVC double insulated 2 core x 1.5 Sq.mm. copper conducter / unarmoured power cable (Finolax,Polycab or equivalent) including removing damaged power cable and encasing new power cable in existing PVC conduit pipe wherevere required . | 200 | m | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.43 MB
NITBIK26.pdf
Tender Documents • 2.42 MB
BOQ_347363.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .