| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC VILL ADHARMANIK P O BASUDEVKHALI P S BERHAMPORE DIST MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹26.8 L+₹24,533 (0.92%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹27.7 L+₹1.1 L (3.95%)Rejected-Finance MAIRAKATA P O GARBETA DIST PASCHIM MEDINIPUR 721127 | GARBETA | PASCHIM MEDINIPUR | WEST BENGAL | 721127 | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹63,880
Closing Date
18 Jul 2025, 12:30 pmClosed
Executive Engineer, PWDte
Bankura
SITC of AC machine and water purifier at Gynae OT and HDU and other allied works within Gynae building MCH building under BSMCH, Bankura.
2025_WBPWD_873215_1
WBPWDTE/EE/BED/NIQ_09/Q of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Wise
45 days
BSMCH
Please refer Tender documents.
3 documents required · 3 mandatory
₹63,880
17 Feb 2026
2 Jul 2025
21 Jul 2025
4 Jul 2025
18 Jul 2025
4 Jul 2025
Amount
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens/schneider of the following sizes as to GS. 4 way Enclosure upto 160 Amp
Supplying and fixing 415 V four pole MCCB of breaking capacity 25kA/35kA with fixed thermal and fixed magnetic/adjustable thermal and fixed magnetic setting in existing DBs/ enclosure and necessary connection Make-Legrand/ Siemens/schneider, as to GS. 125 Amp
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand/ Siemens/schneider, as to GS. 415 V, 63A FP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens/schneider as to GS. 63A TP MCB
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (Make-Legrand/ Siemens/schneider) 4 Way
Supplying & Fixing GI waterproof type looping cable box size 200 x 150 x 100 mm deep having 4 mm thick comprising of one 250V, 15A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2 core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, with drop Concealed type if reqd as per direction of EIC to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175 mm x 100 mm x 65 mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. Average run 10 mtr
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works (At SNCU) 19 mm dia 3 mm thick polythene pipe without earth continuity wire
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works (At SNCU) 25 mm dia 3 mm thick polythene pipe without earth continuity wire
Supply & Fixing 240 V, 1 x 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/ KEI / Gloster /approved by EIC) in 20mm / 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug)
2 x 4 sqmm + 1 x 2.5sqmm (for 2.2 Tr AC Machine )
4 x 6 sqmm + 2 x 4.0 sqmm (for 7.5 Tr AC Machine )
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 2.5 sq mm
Supplying of 1.1 KV Grade following sizes Al. Armoured PVC/ XLPE Cable ( Make : Havells/ Glostar/ KEI/RR kabel ) as per direction of EIC 4 core 70 sqmm ( from Panel to VTPN )
Laying of cable above 4 core 50 sqmm and upto 4 core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 70 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials . 4 core 70 sqmm
Supply of 250 V 50 HZ high flo oscillating type metal body Wall Bracket( Tornedo - 2 ) fan operated by pull cord switch with inbuilt regulator [ Make -Crompton SSTORM 2 (Metal Blade) / Orient Electric Tornado Wall 2/ Similar model of Usha/EPC) 18" (450 mm).
Fixing of Wall Bracket on wall with necessaryS&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length etc to complete the installation and mending good the damages as per direction of EIC
Supply of exhaust fan (Make -- EPC, Heavy duty/equivalent make) of following sizes as per direction of EIC. 30 cm (12"), 1420 RPM
Fixing only exhaust fan after making hole in wall and making hole in wall good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of dia 30 cm (12")
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 30 cm (12")
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supply & Fixing of 250V 50 HZ OLP-3+ 30A single phase A.C Starter ( Make -Electron, / PWD Appvd, as per direction of EIC ) suitable for 1.5 / 2.0 TR Airconditioner Machine incl S & F suitable size G I box (16 SWG) flushed in wall with voltage check, Amp check, Time check incl. making connection as per direction of EIC.
Supplying and fixing of 250 V AC timers fixed on wall with flat iron frame as per direction of EIC and the Box shuld be comprising with the following accessorise --- i) Double-door SPN MCB Distribution Board with IP-42/43 protection 2+10/12 way Enclosureas reqd . ( Make - Legrand / L & T ) – 1 no ii) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer ( Microrex QT31 ) of quartz driven running reserve Day dial back up by nickle cadmium battery [Make - LK (L&T) Cat No. AUTS03ANA00 / Siemens/schneider] – 1 no iii) 250 V, 50 Hz DP Conctractor [Make - LK (L&T) MNX 25-2P type Cat No. CS90240 / Siemens/schneider] – 1 no iv) 250 V, 50 HZ , 32 Amp , DP MCB Isolator [Make - LK (L&T)/ Siemens/ schneider] – 1 no v) Auto / Manual By pass Toggle Switch arrangement – 1 no. vi) 250 V , LED type Indicator lamp ( Make - Legrand / L & T ) – 1 no vii) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power . viii) The complete arrangement must be wiring by 2.5 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make - Legrand /L & T / Crabtree )
Supplying and fixing of 250 V Dual AC timers fixed on wall with flat iron frame as per direction of EIC and the Box shuld be comprising with the following accessorise --- i) Double-door SPN MCB Distribution Board with IP-42/43 protection 2+16 way Enclosure as reqd . ( Make - Legrand / L & T ) – 1 no ii) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer ( Microrex QT31 ) of quartz driven running reserve Day dial back up by nickle cadmium battery [Make - LK (L&T) Cat No. AUTS03ANA00 / Siemens/schneider] – 2 no iii)250 V, 50 Hz DP Conctractor [Make - LK (L&T) MNX 25-2P type Cat No. CS90240 / Siemens/schneider] – 2 no iv) 250 V, 50 HZ , 32 Amp , DP MCB Isolator [Make - LK (L&T)/ Siemens/ schneider] – 1 no v) Auto / Manual By pass Toggle Switch arrangement – 1 no. vi) 250 V , LED type Indicator lamp ( Make - Legrand /L & T ) – 1 no vii) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power . viii) The complete arrangement must be wiring by 2.5 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make - Legrand /L & T / Crabtree )
Supply & Delivery of 230V, 50Hz rated 2.1 ton capacity, 3 star rating Split Air-conditioner machine fitted with Hyper Tropical Rotary copper compressors, Mildew resistant filter, suitable for Refrigerant-R32, Standrad Colling Capacity 6450 W Power Consumption Capacity 1900W, Moisture Removal 2.3 I/H Air Flow 1060 Cu.Mt/Hr. (Make- O general, Model- ASGA24BMWA-B) or equvalent model of Hitachi/Daikin/ PWD Appvd ) with Remote etc . to complete with 25 Amp suitable plug top (North West/appvd) as per direction of EIC.
Installation, Testing & commissioning of 1.5/2.0 Tr. Split type AC both indoor/ outdoor unit incl. S& F of 40 X 40 X 5 mm MS angle iron frame for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC
S& F laying of - (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam nitrile / rubber / K Flex / Accroflex with max saddling with max 1 mtr distance both for suction & discharge pipe and mending good the holes & damages as directed by EIC. (extra length for distance of ODU & IDU exceed 3 mtr.)
S& Laying 3 core 3.5 sqmm PVC insulated & unarmoured copper cable (make-- Finolex/Havells/Gloster) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC.
S & F of flexible PVC high quality water carrying pipe of proper size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC.
Supplying, fabrication & fixing of MS 8 mm road & 25 mm MS flat with necy. welding, screws and lugs with each other 25 x 25 x 5 mm MS angle support with necy. making of frame structure with necy. Two nos hinged arrangement with hatch bolt arrangement with shutter lock (3 key) 2 nos at least for each installation with necy. grouting arrangement on wall by anchoring by 25 x 25 x 5 mm MS angle at least 5" on wall with necy. painting two coat of synthetic enamel paint over one coat of RO primer with necy. direction of EIC For Outdoor units of split AC Machines (for protection)
SITC of Flexi type split airconditioners having Microprocessor based control system and the following specification. Capacity-7.5 Tonnage Rated Cooling Capacity -102000 BTU/Hr No. of IDU-3 No Air-flow/IDU-1000CFM No of ODU- 1 Nos Compressor -3 Nos Refrigerent -R410A Condenser & Cooling Coil:Copper coil Power Supply :415v, 50Hz,3 Ph AC (with applicable tolarance) [ Make-Carrier/Voltas/Blue Star/OGeneral/Hitachi/ DIAKIN] Hitachi Model No.-PAG090KXDA For Auditorium (Area 1350 Sq.ft, Height 20 Ft.) Installation, Testing & Commissioning of the above Air Conditioners by making scaffolding arrangement as per site condition, supply of necessary refrigerent, connecting control & power cabling & other necessary materials to complete the job For 7.5 TRConcealed Units, charges also included-Shifting and lifting of IDU & ODU in different floor or place.
5/8" (15.88 mm.) dia (Hard drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 9mm thick insulation.
3/8" (9.52 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22)mm incl. 9mm thick insulation.
4 core x 1.5 mm² Round PVC insulated copper cable (Make-Polycab/Haavells/ Gloster/Finolex /RR Kable/KEI).
Supply & Fixing of Powder Coated extruded aluminium Supply Air Curtain Grills .
Supply & Fixing of flexiable double Canvas
Supply & laying PVC Drain Pipe 25mm dia with 6mm thick Nitrile Rubber Insulation (Make: Suprime/Oriplast)
Supply & laying PVC Drain Pipe 32mm dia with 6mm thick Nitrile Rubber Insulation (Make: Suprime/Oriplast)
Charges for drop ceiling to cover the indoor unit made of ACP Board (Make- Aludecor/ Alucobond/ Alstone) with painting so as to match and make trap door as required.
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making Base Frame for installation of outdoor unit of 7.5 Tr Concealed Split AC & High wall split incl. drilling holes in each channel, cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2 Nos. horizontal angle of 50 mm x 50 mm x 6 mm as per direction of E.I.C.
Charges of Civil work like wall cutting & mending
Supply & Fixing of GI grill work by 12 x 12 mm GI bar with necessary welding ,screws and lugs with each other 250 x 40 x 40 mm GI angle with necessary making of frame structure with necessary one no hinged arragement with hatch bolt arrangement with shutter lock (3 Key) 2 nos atleast for each installation with necessary grouting arrangement on wall by anchoring by 250 x 40 x 40 mm MS angle at least 5'' on wall incl. 25 x 25 mm GI net cover necessary direction of EIC. Grill wt. above16 Kg./ sq. mtr. Total sq. mtr = 23x 12 = 276 sq .mtr (For the Panel in front of Labour room)
Supply & Fixing 22 SWG ACP Board (Make - Aludecor/direction of EIC) complete with linkage, levers, fittings, supports incl. all accessories any other item required to make the system complete as per direction of EIC. (For HDU UPS)
Supply and Fixing of various sign board lettering acrylic signages i) Supply and fixing of angle iron frame fabricated from 40 mm x 40 mm square four nos hollow bar with cross and radial support including one no 40x40 mm angle iron support in the middle for the Sign board of following size with suitable three nos. crosss angle support welded with 4 nos angle hook in equal space for fixing on the structure with all necessary welding and fabrication. The structure shall rest in both sides with proper welding as per instruction of EIC. ii) S&F LED Sign Board made 3 mm thick ACP Sheet (Alstrong/ Aludecor) finished with approved metallic colour as back ground (blue) after router cutting. The riser structure also shall be covered with ACP Sheet.& appx 6-7 inch depth (Both size ACP sheet) iii) S&F Special type of imported acrylic English letter appx 50 mm thickness flushed on the ACP board made on imported acrylic ACAST sheet. The mater appvd by EIC letter font shall be in horizontal line as mentioned. iv) S&F SMD LED inside the board and to run for each letter including wiring , soldering etc and fixing the SMPS properly with the specification of the SMD --- 1. LED colour : White/ Red/ Blue (make-samsung /Nichia /Cree/Hisine ) 2.Stright : 2 or 3 nos LED per module 3. Luminous Flux : 140 LUMEN 4. Life : 70000 burning hours 5. Visibility: 100 meter atleast normal eye 6. Power Supply: 1.2 watt to1.6 watt per module 7.Input : 230A.C , Output : 12V DC 8.Shape of LED : recrangle or square 9. Grade : IP - 65 v) S & F LED Power supply 300/ 400W IP65 50/60Hz frequency, 108 to 305 VAC driver power supply other electrical accessories the panel prepared along with its necessary arrangement ( make Hisine/Migion/Cehosa/PWD appvd ) vi) Cost of painting of MS structure with 2 coats of RO primer and one coat of synthetic enamel paint after scrapping with emery paper properly make ICI/Asian paints vii) Cost of erection of scaffolding for fixing the Signage viii) Testing and commissioning of the LED board as per following nomenclature
MATERNITY OPERATION THEATRE (8' X 2')
LABOUR ROOM (6' x 2')
PAEDIATRIC WARD (8' X 2')
THALASEMIA DAY CARE UNIT TUESDAY, THURSDAY & FRIDAY (10' X 4')
ANTENATAL TRIAGE (8' X 2')
Supply and Fixing of 3 mm ACP Board of following size with good quality water proof vinyl paper as per direction and design approved by EIC. 500 mm x 300 mm
400 mm x 300 mm
Repairing of Glow sign board made of 20 SWG CRCA sheet rectangular type box replacing the front portion for super quality 2 mm thick poly-carbonaised front facia to be placed with subject matter opted for display as on computerised vinyle paper in it as the style for the work of each letter (size 8"x6") of subject matter as front facia to be displayed by curing & inscribling support computerised cutting vinyle paper, pasting by water solution & covering all corners incl. S&F aluminium angle along the four sides the glow sign board for fixing the metalic screw after drilling holes on the facia incl. the vinyle board duly fitted with necy. LED Tube light (230V, 4", 18 watt) including S&F necy. connection by single core PVC copper wire for uniform lighting the above board to be painted after preparing surface of both inside & outside MS structure with 2 coats of RO primer and one coat of synthetic enamel paint after scrapping with emery paper properly make ICI/Asian paints and repairing of all supports of glow sign board such as damaged angle, back side winches etc. incl. necy. ctting, weilding, grinding work with necessary fixing arranement as per direction of EIC.
JASODA REFRIGERATOR SERVICING CENTRE (BID ID -6704922)
R.K.ENTERPRISE (BID ID -6704093)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .