Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹1.1 Cr+₹2.2 L (2.02%)Rejected-AOC | ₹1.1 Cr+₹2.2 L (2.02%) | L2 | Rejected-AOC Not awarded |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
26 Feb 2024, 11:00 amClosed
SE, PWD(R), City Road Circle
Bamunimaidam, Guwahati
Improvement of Raj Bhawan Dispensary Road by providing GSB, WBM G3, CC Pavement and antiskid paver tiles along with development of Children Park and Residential Colony area of Raj Bhavan, Guwahati under SOPD- G for the Year 2023-24.
2024_PWD_36487_1
CS/NGTRD/3/SOPD-G/2023-24
Open Tender
Civil Works
Works
180 days
Kamrup
Please refer Tender documents.
6 documents required · 6 mandatory
₹3,325
Yes
₹2.2 L
Yes
6 Mar 2024
22 Feb 2024
26 Feb 2024
22 Feb 2024
26 Feb 2024
22 Feb 2024
22 Feb 2024 - 26 Feb 2024
Amount
ROADWORKS: Dismantling of Flexible Pavements Dismantling of flexible pavements and disposal of dismantled matenals upto a lead of 100 m, stacking serviceable and unserviceable matenals separately as per Technical Specification Clause 202. a) Bituminous Courses
Dismantling of Cement Concrete Pavements as per Technical Specification Clause 202. Dsmantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 002 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Construction of granular sub-base by providing well graded matenal, spreading in unform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) for gradng II material
Water Bound Macadam Providing. laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applytng and brooming, stone screening to fill-up the interstices of coarse aggregate watering and compacting to the required density Grading 3 as per Technical Specification Clause 405, A By manual means
Supplying, fitting placing TMT IS:1786 (Fe 500) bæ reinforcerent in sub-structure complete as per drawing and technical speafications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/ Shyam steel or equivalent)
Plain/Reinforced cernent concrete, in sub-structure complete as per drawing and technical specification and steel shuttering formwork P) With plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) acceleratng plasticiser(MasterpIast ACPL or equivalent) conforming to IS-9103-1999 F) RCC Grade M25 a) Hetght upto 5m, Case II) With Batching Rant, Transit Mixer and Concrete Pump
Providing, fitting & fixing in position Anti skid paver tiles as per BIS specifications of Size (300mm x 300 mm x 25 mm) as directed and approved by the Deptt
V Shaped Drain: Earthwork in excavation for structures as per drawing and technical specifications Clause including setting out, construction o shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material,
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause
Plan/reinforced cement concrete in substructure complete as per drawings and techno speaficatjon Clauses 802.804. 805, 806, 807, 1202 ans 1204, With Crushed Stone, PCC M15 (1:2.5:5)
Edge Restrainer: Plain/reinforced cement concrete in substructure complete as per drawings and techmcal specification Clauses 802, 804 805, 806, 807, 1202 ans 1204 With Crushed Stone PC.C grade M 15
Earth Filling: Construction of Embankment With Matenal Obtained from Borrow Pits Construction of embankment with approved matenal obtained from borrow pits with a lift upto 1 f m, to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 ard 3002 with a lead upto 1000 m as per Tecthnical Specification Clause 301.5 (i) Private Land
Turfing: Grasstng with ' Doobs' Grass (Grassng With 'Doobs' grass including watering and maintenance of the lawn for 30 days or mote till the grass forms a thick lawn free from weeds and fit for moving including supplying good earh if needed) ii) In rows 7.5 cm apart in either direction
PLASTERING AND GROOVING ON BOULDER WALL: 15 mm cement plaster on the rough side of single or half back wall of mix
Extra for lining out plaster to imitate stone or concrete blocks walling
Construction of roadside wall (height-0 9m. width=250mm): Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m. as directed by Engineer-in-charge
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Brick work with common burnt clay F.PS. (non modular) bricks of class designation 7.5 in foundation and plinth in:.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-111) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Lintels. beams, plinth beams. girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1:4
15 mm cement plaster on the rough side of single or half brick wall of mix (1:4)
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 1 8 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge: Flamed finished granite stone slab jet black, cherry red, Elite Brown, Cat Eye or equivalent
Distemper with oil bound washable distemper of a proved brand and manufacture to give an even shade
Construction of boundary wail with grill & gate around children park (Height = 1.4m): Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m. as directed by Engineer-in-charge
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Brick work with common burnt clay F.PS. (non modular) bricks of class designation 7.5 in foundation and plinth in:.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-111) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Lintels. beams, plinth beams. girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 1 8 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge: Flamed finished granite stone slab jet black, cherry red, Elite Brown, Cat Eye or equivalent
12 mm Cement Plaster of Mix (1:4)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar. ladder, railings, brackets, gates and similar works
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 Itr/ 10 sqm over an under coat of primer applied @ 0.80 Itr /10 sqm of approved brand and manufacture
Distempering with oil bound washable distemper or approved brand and manufacture to give an even shade
ANALYSIS OF FENCING OVER BEAM AT BACKSIDE OF RESIDENTOAL AREA: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, propping etc. and removal of form for Lintels. beams, plinth beams. girders, bressumers and cantilevers
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3
12 mm Cement Plaster of Mix (1:4)
Distempering with oil bound washable distemper or approved brand and manufacture to give an even shade
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete,
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25125 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 Itr/ 10 sqm over an under coat of primer applied @ 0.80 Itr /10 sqm of approved brand and manufacture
CONSTRUCTION OF GATE NEAR SURYANAMASKAR AREA: Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m. as directed by Engineer-in-charge
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Brick work with common burnt clay F.PS. (non modular) bricks of class designation 7.5 in foundation and plinth in:.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-111) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Lintels. beams, plinth beams. girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 1 8 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge: Flamed finished granite stone slab jet black, cherry red, Elite Brown, Cat Eye or equivalent
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar. ladder, railings, brackets, gates and similar works
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 Itr/ 10 sqm over an under coat of primer applied @ 0.80 Itr /10 sqm of approved brand and manufacture
CONSTRUCTION OF GATE AT THE ENTRANCE OF RESIDENTIAL AREA: Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m. as directed by Engineer-in-charge
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Brick work with common burnt clay F.PS. (non modular) bricks of class designation 7.5 in foundation and plinth in:.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-111) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Lintels. beams, plinth beams. girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 1 8 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge: Flamed finished granite stone slab jet black, cherry red, Elite Brown, Cat Eye or equivalent
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar. ladder, railings, brackets, gates and similar works
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 Itr/ 10 sqm over an under coat of primer applied @ 0.80 Itr /10 sqm of approved brand and manufacture
CONSTRUCJ ION OF GATE AT BACKSIDE OF RESIDENTIAL AREA: Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m. as directed by Engineer-in-charge
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Brick work with common burnt clay F.PS. (non modular) bricks of class designation 7.5 in foundation and plinth in:.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-111) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Lintels. beams, plinth beams. girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
Distempering with oil bound washable distemper or approved brand and manufacture to give an even shade
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete,
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25125 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 Itr/ 10 sqm over an under coat of primer applied @ 0.80 Itr /10 sqm of approved brand and manufacture
REPAIRING OF SANTRY POST: Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papenng and preparing the surface smooth including necessary repairs to scratches etc. complete.
Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in:
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
Demolishing RCC manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of
Brick work with common burnt elay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in
12 mm Cement Plaster of Mix (1:4)
15 mm cement plaster on the rough side of single or half brick wall of mix (1:4)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth
Cement concrete flooring 1 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement. includingcement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (I cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks. bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required: 0.63 mm thick with zinc coating not less than 275 gm/m2
ELECTRICAL WORKS AT RAJ BHAWAN: Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surtåce/ recess. complete with tinned copper bus bar, neutral bus bar. earth bar. din bar, interconnections, powder painted including earthing etc. as required. (But without MCB, RCCB/lsolator): 12 Way, Double Door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel. dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB T PDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB(IsoIator) 4 way (4 + 12); Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, IO kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, IO kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, IO kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Wiring for light point' fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular pla!e, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP C
Wiring for group controlled (looped) life point/ fan point/ exhaust fan point/ call bell point without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduits 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pm 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 1 5/16 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 1 00 mm width X 50 mm depth X 1.6 mm thickness
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + I X 1.5 s , mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + I X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + I X 4 sq. mm earth wire
Supplying Installation , Testing & Cornmisionning of Spike light
Supplying Installation , Testing & Cornmisionning of Inground light
Supplying Installation , Testing & Cornmisionning of Victorian gate light
Supplying Installation , Testing & Cornmisionning of Victorian piller light
Children playing equipments
TREE PLANTATION: Plantation with chosen species(Copper pod tree, Kanchan tree, Golden Laburnum (xunaru) etc.) as per direction of Engineer-in-charge.
Natural manuring of gardening area
Maintenance of garden area & Plantation for one year (watering, weeding, gap filling, manuring)
UGPB Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .