Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹24.8 L+₹1.8 L (7.81%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹25.7 L+₹2.7 L (11.5%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹27.5 L+₹4.5 L (19.5%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹29.4 L+₹6.4 L (27.8%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L5 | Rejected-Finance Being 5th lowest |
| Sl No | Description | Qty | Unit | DHEER ENGINEERING L9 | PANWAR CONSTRUCTIONS L8 | ISHWAR ELECTRICALS AND PROCESS SERVICES L7 | Raman Electric Trading Co L6 | BRIJ CONSTRUCTIONS L3 | M/s badrinath Traders L10 | M/s Prakash Enterprises L4 | sanjeev enterprises L1 | VIJAY ENTERPRISES L5 | trinity construction L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Receiving Electrical & Mechanical complaints related to DG sets installed at AFS, Sarsawa allied units from complaints section/ JE E&M/ Engineer-in-Charge in written or by telephoically & attending the same within 2 hrs. This item is inclusive of all preliminary work like opening of connectios, checking for supply, transportation of necessary tools and labour, assessing the nature of complaints, rectifying minor issues, removing air lock (if any), reconnecting the DG set back for proper functioning. Part shall be measured & paid separately under respective item of schedule complete all as specified and directed.
Note: Non compliance of attending breakdown & complaints within 2 hours after notification of the complaint will attract penalty @ Rs.1000/- per complaint/day shall be recovered from contractor's payment for each complaint so notified. contractor shall deploy sufficient resources along with personnel safety equipments to keep all the DG sets functional. | 295 | Each Job | 175 ₹51,625 | 150 ₹44,250 Lowest | 450 ₹1,32,750 | 410 ₹1,20,950 | 350 ₹1,03,250 | 500 ₹1,47,500 | 500 ₹1,47,500 | 300 ₹88,500 | 200 ₹59,000 | 300 ₹88,500 |
| 2.00 | Supply only on load change over switch in replacement of capacity 63 Amps 415 volts with sheet enclousers complete all as specified and directed. | 2 | Each | 7,200 ₹14,400 | 3,500 ₹7,000 | 5,400 ₹10,800 | 7,000 ₹14,000 | 4,000 ₹8,000 | 3,000 ₹6,000 | 5,000 ₹10,000 | 4,500 ₹9,000 | 2,500 ₹5,000 Lowest | 6,000 ₹12,000 |
| 3.00 | Supply only on load change over switch in replacement of capacity 125 Amps 415 volts with sheet enclousers complete all as specified and directed. | 2 | Each | 9,800 ₹19,600 | 4,500 ₹9,000 | 9,000 ₹18,000 | 8,500 ₹17,000 | 5,000 ₹10,000 | 5,000 ₹10,000 | 7,000 ₹14,000 | 5,000 ₹10,000 | 3,500 ₹7,000 Lowest | 7,000 ₹14,000 |
| 4.00 | Supply only on load change over switch in replacement of capacity 200 Amps 415 volts with sheet enclousers complete all as specified and directed. | 1 | Each | 13,800 ₹13,800 | 5,500 ₹5,500 Lowest | 6,300 ₹6,300 | 13,500 ₹13,500 | 6,500 ₹6,500 | 10,000 ₹10,000 | 8,000 ₹8,000 | 6,200 ₹6,200 | 6,500 ₹6,500 | 10,000 ₹10,000 |
| 5.00 | Supply, install, testing, and commissioning in replacement of AMF Panel CPR Approved of rating 63 KVA for the DG Set. The AMF panel shall be totally enclosed, dust, damp and vermin proof cubicle type free standing floor mounted type made out of 1.6mm/2.0mm thick CRCA sheet for the panel located inside the acoustic enclosure. If the AMF panel has to be located outside the acoustic enclosure, the outer shell of the panel should be made out of 3mm thick CRCA sheet and provided with a canopy and the degree of protection shall be IP 54 The AMF Panel should be equipped with the following control gear and componerts :-
(a)Power contactor -4 pole of current rating 63 Amp with thermal overload relay-02 Nos ( for alternator and mains ) (b) MCB of suitable current rating for short circuit protection (c) Microprocessor based AMF module incorporating function :- - Supply failure timer -Restoration timer -3 Impulse automatic engine start/ stop logic - Mains / generator voltage & frequency sensing (d) Aluminium bus bars of capacity 100 amp with incoming/ outgoing terminals.
(e) Instrument fuses duly wired and ferruled (f) MCCB of rating 63 amp , 4 pole with overload and short circuit protection -02 nos (for alternator & mains ) (g) Current transformers of suitable rating (h) Microprocessor based generator set monitoring and control system with LCD display integrated with all features , function and protection of engine and alternator provided with separated LED indication lamp for each. | 2 | Each | 1,91,100 ₹3,82,200 | 72,000 ₹1,44,000 Lowest | 90,000 ₹1,80,000 | 1,27,000 ₹2,54,000 | 79,000 ₹1,58,000 | 1,20,000 ₹2,40,000 | 2,00,000 ₹4,00,000 | 98,000 ₹1,96,000 | 1,00,000 ₹2,00,000 | 1,05,000 ₹2,10,000 |
| 6.00 | Supply, install , testing ,and commissioning in replacement of AMF Panel CPR Approved of rating 125KVA for the DG Set. The AMF panel shall be totally enclosed, dust, damp and vermin proof cubicle type free standing floor mounted type made out of 1.6mm/2.0mm thick CRCA sheet for the panel located inside the acoustic enclosure. If the AMF panel has to be located outside the acoustic enclosure, the outer shell of the panel should be made out of 3mm thick CRCA sheet and provided with a canopy and the degree of protection shall be IP 54 The AMF Panel should be equipped with the following control gear and componerts :-
(a)Power contactor -4 pole of current rating 63 Amp with thermal overload relay-02 Nos ( for alternator and mains ) (b) MCB of suitable current rating for short circuit protection (c) Microprocessor based AMF module incorporating function :- - Supply failure timer -Restoration timer -3 Impulse automatic engine start/ stop logic - Mains / generator voltage & frequency sensing (d) Aluminium bus bars of capacity 100 amp with incoming/ outgoing terminals
(e) Instrument fuses duly wired and ferruled (f) MCCB of rating 63 amp , 4 pole with overload and short circuit protection -02 nos (for alternator & mains ) (g) Current transformers of suitable rating (h) Microprocessor based generator set monitoring and control system with LCD display integrated with all features , function and protection of engine and alternator provided with separated LED indication lamp for each. | 2 | Each | 1,81,110 ₹3,62,220 | 85,000 ₹1,70,000 Lowest | 90,000 ₹1,80,000 | 1,40,000 ₹2,80,000 | 95,000 ₹1,90,000 | 1,50,000 ₹3,00,000 | 2,00,000 ₹4,00,000 | 1,20,000 ₹2,40,000 | 1,02,500 ₹2,05,000 | 1,25,000 ₹2,50,000 |
| 7.00 | Disconnecting and taking down old unserviceable self starter, 12 Volt DC and dismantling complete for repair, servicing, cleaning, varnishing, oiling, reassembling & testing including replacement of the Following parts complete all as epcified and directed:-
(a) Armature – 01 No
(b) Solenoid switch – 01 No.
(c) Field coils – 02 No.
(d) Commutator – 01 No.
(e) Carbon brush – 02 Nos.
(f) Bendex assembly – 01 No
(g) Tension sleeve – 01 No.
(h) Gear assembly – 01 No. | 12 | Each | 29,000 ₹3,48,000 | 4,500 ₹54,000 | 3,600 ₹43,200 | 3,700 ₹44,400 | 3,500 ₹42,000 | 3,000 ₹36,000 | 3,000 ₹36,000 | 3,500 ₹42,000 | 2,000 ₹24,000 Lowest | 3,000 ₹36,000 |
| 8.00 | All as per Item No 7.00 here-in-above but for 24 Volts DC capacity complete all as specified and directed. | 2 | Each | 3,311 ₹6,622 | 4,500 ₹9,000 | 4,500 ₹9,000 | 4,200 ₹8,400 | 4,500 ₹9,000 | 5,000 ₹10,000 | 2,000 ₹4,000 Lowest | 8,500 ₹17,000 | 3,000 ₹6,000 | 5,000 ₹10,000 |
| 9.00 | Supply only in replacement of Governor assembly for DG Set capacity 100 KVA to 200 KVA as per existing Make complete all as specified and directed by Engr-in-Change. | 1 | Each Job | 9,300 ₹9,300 | 22,000 ₹22,000 | 18,000 ₹18,000 | 14,800 ₹14,800 | 18,000 ₹18,000 | 5,000 ₹5,000 Lowest | 5,000 ₹5,000 Lowest | 6,500 ₹6,500 | 20,000 ₹20,000 | 15,000 ₹15,000 |
| 10.00 | Supply only in replacement of Governor assembly for DG Set capacity 30 to 63 KVA as per existing all as specified and directed by Engr-in-Change. | 1 | Each Job | 5,700 ₹5,700 | 9,500 ₹9,500 | 9,000 ₹9,000 | 5,000 ₹5,000 | 8,000 ₹8,000 | 5,000 ₹5,000 | 3,000 ₹3,000 Lowest | 5,000 ₹5,000 | 8,000 ₹8,000 | 5,000 ₹5,000 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
3 Oct 2025, 6:00 pmClosed
SHRI PRASANTA KACHARI GE (AF) SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P), PIN- 247232
REPAIR AND MAINT OF DG SETS AT AF STN SARSAWA UNDER GE (AF) SARSAWA
2025_MES_729308_1
8125/SAR-T-52/2025-26
Open Tender
Civil Works
Item Rate
330 days
GE(AF) SARSAWA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE(AF) SARSAWA
₹80,000
Yes
13 Nov 2025
4 Sept 2025
10 Oct 2025
4 Sept 2025
3 Oct 2025
18 Sept 2025
4 Sept 2025 - 18 Sept 2025
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .