Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC C O APERNA TRADERS COURT ROAD UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹14.9 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹15 LRejected-Finance | ₹15 L | L2 | Rejected-Finance Other than L1 |
| 3 | Rejected-Technical AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | - | - | Rejected-Technical Not recommended since residual amount of wk load in hand is more than five times the tendering limit of firm (Ref Note 1 of Appx A to NIT). |
| Sl No | Description | Qty | Unit | KAMLA CONSTRUCTION COMPANY L1 | MALIK CHAND SIRI RAM L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of pipe, cables, poles etc and getting out in hard/dense soil, complete all as specified and/or as directed by Engr-in-Charge. | 60.39 | Cum | 350 ₹21,136.50 | 120 ₹7,246.80 |
| 2.00 | All as per ser item No. 01 above, but exceeding 1.5m depth and not exceeding 3m depth. | 0.11 | Cum | 450 ₹49.50 | 130 ₹14.30 |
| 3.00 | M&L for Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified and/or as directed by Engr-in-Charge. Note : Punned thickness of 18 CM will be measured and paid for. | 17.79 | Cum | 1,050 ₹18,679.50 | 550 ₹9,784.50 |
| 4.00 | Supply and lay factory made unreinforced precast concrete cable cover class LV type I flat size 250x150x40mm complete all as specified and directed. | 1,464 | Each | 26 ₹38,064 | 22 ₹32,208 |
| 5.00 | Returning, filling in, including spreading levelling watering and well ramming in layers not exc. 25 cm thick complete all as specified and/or as directed by Engr-in-Charge. | 35.39 | Cum | 70 ₹2,477.30 | 10 ₹353.90 |
| 6.00 | Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and/or as directed by Engr-in-Charge. | 25.11 | Cum | 210 ₹5,273.10 | 40 ₹1,004.40 |
| 7.00 | M&L for providing PCC 1:4:8, type D2 in foundation filling and mass concrete (using 40 mm graded stone aggregate) for pole/stay foundation etc. complete all as specified and/or as directed by Engineer-in-Charge. | 0.22 | Cum | 5,500 ₹1,210 | 3,200 ₹704 |
| 8.00 | M&L for providing PCC 1:3:6, type C2 in foundation filling and mass concrete (using 40 mm graded stone aggregate) for pole/stay foundation etc. complete all as specified and/or as directed by Engineer-in-Charge. | 2.16 | Cum | 8,600 ₹18,576 | 3,400 ₹7,344 |
| 9.00 | M&L for providing PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) for coping of pole including necessary form work complete all as specified and/or as directed by Engineer-in-Charge. | 0.96 | Cum | 6,500 ₹6,240 | 3,600 ₹3,456 |
| 10.00 | Supply, lay & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 120 sq mm complete all as specified and/or as directed by Engr-in-Charge. | 25 | RM | 1,250 ₹31,250 | 1,760 ₹44,000 |
Tender Value
₹13.6 L
EMD Value
₹27,200
Closing Date
30 Sept 2025, 6:00 pmClosed
CWE, HQ 138 WE
CWE, HQ 138 WE
PROVN OF REPLACEMENT OF EXISTING 100 KVA TRANSFORMER WITH 200 KVA TRANSFORMER AT LEH UNDER GE 865 EWS
2025_MES_728855_1
138WE/L-170/2025-26
Open Tender
Civil Works
180 days
GE 865 EWS
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE 865 EWS
₹27,200
Yes
3 Jan 2026
2 Sept 2025
7 Oct 2025
2 Sept 2025
30 Sept 2025
16 Sept 2025
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of pipe, cables, poles etc and getting out in hard/dense soil, complete all as specified and/or as directed by Engr-in-Charge.
All as per ser item No. 01 above, but exceeding 1.5m depth and not exceeding 3m depth.
M&L for Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified and/or as directed by Engr-in-Charge. Note : Punned thickness of 18 CM will be measured and paid for.
Supply and lay factory made unreinforced precast concrete cable cover class LV type I flat size 250x150x40mm complete all as specified and directed.
Returning, filling in, including spreading levelling watering and well ramming in layers not exc. 25 cm thick complete all as specified and/or as directed by Engr-in-Charge.
Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and/or as directed by Engr-in-Charge.
M&L for providing PCC 1:4:8, type D2 in foundation filling and mass concrete (using 40 mm graded stone aggregate) for pole/stay foundation etc. complete all as specified and/or as directed by Engineer-in-Charge.
M&L for providing PCC 1:3:6, type C2 in foundation filling and mass concrete (using 40 mm graded stone aggregate) for pole/stay foundation etc. complete all as specified and/or as directed by Engineer-in-Charge.
M&L for providing PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) for coping of pole including necessary form work complete all as specified and/or as directed by Engineer-in-Charge.
Supply, lay & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 120 sq mm complete all as specified and/or as directed by Engr-in-Charge.
Supply & fix Steel tubular swaged poles complete with cast iron/mild steel base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metre long) including drilling of necessary holes, & painting complete all as specified and/or as directed by Engr-in-Charge. Note :- (i) Cost of painting & numbering on poles i.e. making five no. alternative white & black strips 30 cm height each (up to 1.50 metre height from top of PCC coping & numbering to the poles with synthetic enamel paint etc shall be deemed to be included in the rates of above items. (ii) Earthwork, PCC foundation & coping shall be measured and paid separately under respective item of Schedule A
Supply and fix of air break switch gang operated (GOD) triple pole with drop out fuses mechanically operated, mounted on insulators 15 Nos & steel frame with operating mechanism & operating rod of GI pipe 25mm & medium grade with necessary clamps to be operated from ground level 11000 Volts grade working pressure and current up to 200 Amps complete all as specified and/or as directed by Engr-in-Charge.
Supply and fix of Lightning arresters expulsion type complete with all fittings, 30 kilo amp discharge capacity, distribution class Make- AREVA / ALSTHOM or equivalent makes suitable for 11 KV HT over head network including necessary connections with HT over head lines complete all as specified and/or as directed by Engr-in-Charge.
M&L for earthing complete with Galvanized Steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to and including Gi iron strip of size 32x6 mm flat by means of GI bolts, nuts, and washers, protected by 40mm bore Gl light grade ISI marked pipe up to and including test points. Earthing plate shall be surrounded by alternate layers 15cm thick of charcoal or coke and common salt all around bottom and top, 20mm dia Gl medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C2 (using 20mm graded crushed store aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling in and disposal of surplus soil to a distance not exceeding 50 M, pit cover 40 mm thick made with RCC (1:2:4) type B-1 (using 20mm graded crushed store aggregate) including TMT reinforcement 80mm dia @ 75 mm C/C both way, MS handle of 12 mm dia, cover rest on MS angle iron frame 40x40x6mm embedded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as shown in electrical plate No-3 of SSR Part-l complete all as specified and/or as directed by Engr-in-Charge.
Supply, installation, testing and commissioning complete out door type step down transformer 11/.433 KV 200 KVA copper wound, three phase, 50 Hz, DYN11, ONAN type, including of standard accessories like conservator, silica gel, air breather, cooling fins, HT & LT cable end boxes or bus duct flange, lighting lugs, Bi-directional plain/Flanged rollers, Earthing terminal, Air release plug, Off load tap charger (+5 to 10% in steps of 2.5%) winding/Top oil temperature rise of 45 degree centigrade/40 degree centigrade, ISI marked drain valve, Dial type temp gauge, first fill oil, Epoxy based paint etc. having max total losses as per energy efficiency level-2 at basic insulation conforming to IS 2026 (Part-I to Part-II) latest amended and IS 1180 Part I: 2014 BEE star level-I as per Govt of India, Ministry of Power notification Dated 16 Dec 2016 complete all as specified and/or directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 Sq mm 3.5 core complete all as specified and/or as directed by Engr-in-Charge.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sq mm 3.5 core complete all as specified and/or as directed by Engr-in-Charge.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sq mm 3.5 core complete all as specified and/or as directed by Engr-in-Charge.
Supply and fixing for cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
MALIK CHAND SIRI RAM (BID ID -3433747)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid