Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical Not submitted reqisite documents |
| 3 | Rejected-Technical | Rejected-Technical Not submitted the requisite documents |
| 4 | Rejected-Technical | Rejected-Technical Not submitted the requisite documents |
Tender Value
₹49.8 L
EMD Value
₹99,526
Closing Date
14 Nov 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Deputy Conservator of Forests
MILL DIVISION, CHATHAM
Rain Water Harvesting at Saw Mill Division Chatham
2023_DCFMD_12147_1
76/Genl/MD/2022-23/Plan/RWH
Open Tender
Civil Works - Others
Works
180 days
MILL DIVISION, CHATHAM
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹99,526
Yes
22 Dec 2023
31 Oct 2023
15 Nov 2023
31 Oct 2023
14 Nov 2023
31 Oct 2023
Amount
TERMS AND CONDITIONS 1. Only specialised firms related to the work of Modular Rain water harvesting system shall be allowed to participate in the tender 2. Contractors should produce definite proof of experience from the appropriate authority,which shall be to the specification of the competent authority of haviing satisfactorily complted required value works with Govt. Organisation in A & N islands .
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m
Supplying, filling, spreading & levelling stone aggregates of size range 30 cm to 40 mm nominal size in foundation in required thickness of 100 mm for all lead & lifts, all complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) excluding the cost of centering and shuttering above soling 150 mm thick
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Supply & installation of Polymer based modules (Honeycomb design on each plate) made up of 100% recycled polypropylene capable of taking light vehicular movement upto atleast 30 tonnes / sqm with adequate backfilling & 4 small plates combination creating 3 spans inside the module. These modules are made from combination of large (683*410mm) and small (369*410mm) plates ( Approved make such as Atlantis/Polypipe/Retas Enviro Solutions/ Rehau) along with external locks. Each large plate should have atleast fourteen external locking slots inorder to give stability to tank. These tank should have optimum connection & block stability using double lock stability. Each single tank is made of four large and four small plates in case of single tank and 10 large & 12 small plates for triple tank. Capacity of single tank is (.683*.410*.450) equals to 0.126 CUM. Weight of each large plate should be atleast 1050 gms and each small plate should be atleast 550 gm. The design to be approved by Engineer-in-Charge
Providing and fixing of non woven geotextile having thickness of 400 GSM, having minimum tear strength of 250 ASTM D4533, Width wise atleast 215 ASTM D4533 having puncture strength of 1550 plus asper ASTM D6241 Having elongation at Break of 57% plus as per ASTM D 4595 in two layers, made out of long fibres to hold the modules including cutting, sizing, Heat welding and needle punched for high porosity and proper percolation. complete as per entire satisfaction of engineer-in-charge.
Providing and fixing of EPDM liner having thickness of 1.12 mm, including cutting, sizing, sealing of Liner complete as per entire satisfaction of engineer-in-charge.
Providing, fixing, installing, testing & commissioning of FRP based Micro filter with diameter of 750 mm and height 1000 mm having inlet of 6 inches and outlet of 6 inches with SS 304 mesh. Flow rate of microfilter should be at least 40 - 45 KL / Hr. (FRP based RWH Filters should be GRIHA and SVAGRIHA Certified. The product should be registered under GRIHA Criterions 21 & 18 and SVAGRIHA Criterion 9. Certificate should be valid on the current date.)
Providing, fixing, installing, testing & commissioning of FRP based Microfilter with diameter of 750 mm and height 1000 mm having inlet of 6 inches and outlet of 6 inches with SS 304 mesh . Flow rate of microfilter should be atleast 40 - 45 KL / Hr. ( FRP based RWH Filters should be GRIHA and SVAGRIHA Certified. The product should be registered under GRIHA Criterions 21 & 18 and SVAGRIHA Criterion 9. Certificate should be valid on the current date.)
Supply and complete fittings of PVC Pipe of 150 mm dia to connect desitling tank to FRP Filter and filter to RWH Tank WITH 100 MM thick CC beneath pipeline
Supply, Installation, Testing, and commisioning of 1.02 HP/0.75 KW single phase monobloc pump set
Constructing brick masonry manhole ( silt chamber type) of size 300X300X300 cm deep with FPS bricks of class designation 7.5 in cement mortar 1:4( 1 Cement : 4 manufacturing sand upto 100%) 15 cm thick RCC top slab with 500mm dia opening with cement concrete 1:2:4 ( 1 Cement: 2 manufacturing sand upto 25%: 4 recycled aggregate 20mm nominal size upto 25%) reinforced with a 18.92 Kg/each TMT bars, 20 cm foundation cement concrete 1:4:8 ( 1 Cement: 4 Manufacturing sand upto 100% recycled aggregate 40mm nominal size upto 100%) inside plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 manufacturing sand upto 100% ) finished with a floating coat of neat cement and providing 75mm thick bed cement concrete of 1:2:4 ( 1 Cement: 2 manufacturing sand upto 25%: 4 recycled aggregate 20mm nominal size upto 25%) including neat cement punning inside the manhole complete as per standard design. (Depth shall be measured from invert level of pipe upto top of RCC slab). Difference of 30cm shall be kept between invert level of pipe and manhole bottom excluding the cost of SFRC manhole cover and frame 500mm dia which shall be paid separately. All complete as per direction of Engineer-in-charge.
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .