| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC L1 accepted | |
| 2 | L2₹20.2 L+₹72,302.15 (3.72%)Rejected-Finance | L2 | Rejected-Finance Other than L1 L1 after deducting Sch of Credit Rs 84,525.00 | |
| 3 | L3₹21.1 L+₹1.7 L (8.68%)Rejected-Finance | L3 | Rejected-Finance Other than L1 L1 after deducting Sch of Credit Rs 84,525.00 | |
| 4 | L4₹21.6 L+₹2.1 L (11.0%)Rejected-Finance | L4 | Rejected-Finance Other than L1 L1 after deducting Sch of Credit Rs 84,525.00 | |
| 5 | L5₹21.7 L+₹2.2 L (11.6%)Rejected-Finance | L5 | Rejected-Finance Other than L1 L1 after deducting Sch of Credit Rs 84,525.00 |
Tender Value
Refer Docs
EMD Value
₹50,600
Closing Date
29 May 2021, 6:00 pmClosed
GE NORTH AKHNOOR
GE NORTH AKHNOOR C/O 56 APO
SPECIAL REPAIR TO BLDG NO P 20 TR 13 AND COOK HOUSE CUM DINING HALL AT BLDG NO T3 AT AKHNOOR UNDER GE NORTH AKHNOOR
2021_MES_439883_1
GE(N)/AKH-05/2021-22
Open Tender
Civil Works
Item Rate
180 days
AKHNOOR
CLASS D cat a i
8 documents required · 8 mandatory
₹500
Yes
GE NORTH AKHNOOR
₹50,600
Yes
27 Jul 2021
3 May 2021
31 May 2021
3 May 2021
29 May 2021
17 May 2021
Amount
Dismantling of frame work timber scantling 40 Sqcm and over in section, in any position. complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) , complete all as specified & directed.
Demolition of stone/brick masonary built in cement/cement lime mortar including all quoins arches etc but exlcuding ashlar masonry complete all as specified and directed.
Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and as directed by Engineer -in-Charge
Ditto all as per Srl item No 5 here-in-above but except bricks.
25 mm thick PCC 1:2:4 type B-1, (using 20 mm graded stone aggregate) including finishing surface of concrete topping even and rough as in levelling course complete all as specified and directed by Engineer-in-Charge.
M&L plain cement concrete type B0 1:2:4 (using 20mm graded crushed stone aggregate) as in bed block, plinth courses, apex stones etc complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloured jointless tiles 7mm to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm, but not exceeding 0.18 Sqm, in floors over set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles including 15mm thick screed bed in CM (1:6) complete all as specified and as directed by Engineer-in-Charge.
Glazed ceramic tiles , coloured 450x350x7mm thick on vertical surface such as skirting/dado over & jointed in neat cement slurry & pointed in white or coloured cement to match the shade of tiles including 10 mm thick in CM 1:4 bedding layer to receive tiles complete all as specified and as directed by Engineer-in-Charge.
Machine cut kota stone slab flooring 20-25mm thick as in flooring jointed with grey cement slurry mixed with pigment to match the shade or the slab including rubbing and polishing complete including 20mm thick screed bed in CM 1:6 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge. (Size of Kota Stone slab shall be 52 cm x 52 cm).
Ditto all as per item No. 11 here-in-above but as in riser of steps ,skirting, dado and pillar complete all as specified and as directed by Engineer-in-Charge.
Rubbing and polishing of kota stone all as specified.
M&L for 20 mm thick makrana white marble tiles as in flooring/border, bedded and jointed with white cement slurry 1:2 using marble dust including cutting and polishing including screed bed 20mm thick in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
M&L for 20 mm thick makrana white marble tiles as in Steps/stair, skirting/dado etc, bedded and jointed in white cement 1:2 using marble dust including cutting and polishing including bedding layer of 20mm thick cement mortar 1:6 including pointing complete all as specified and as directed by Engineer-in-Charge.
TMT reinforcement bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer -in-Charge.
All as per Srl Item No 16 here-in-above but in stirrups complete all as specified and as directed by Engineer -in-Charge.
M&L for Reinforced cement concrete (nominal mix), type B1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in chajjas, roof projections etc including demolition of existing reinforced cement concrete complete all as specified and as directed by Engineer -in-Charge.
M&L for Reinforced cement concrete (nominal mix), type B1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in beams, cantilevers, lintels over 1.5m span,lintel bends etc complete all as specified and as directed by Engineer -in-Charge.
Formwork (rough finished flat surface) to sides of RCC/PCC bands similar items including edges complete all as specified.
Formwork (rough finished flat surface) to WHB counter, chajjas and similar items including edges complete all as specified.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof overing/ cladding to wall, fixed with self tapping screws including dismantlling of existing asbestos cement (corrugated, semi corrugated) sheets as in roof covering including ridges,hips, valleys and flashings etc complete all as specified & directed by Engineer-in-Charge.
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in ridge/valleys, fixed with self tapping screws incl ridge complete all as specified & directed by Engineer-in-Charge.
Taking down cement plaster from brick or stone walls including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and as directed by Engineer-in-Charge.
Rendering 10 mm thick in cement and sand mortar 1:6 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth (without using extra cement) complete all as specified and as directed by Engineer-in-Charge.
Rendering 15 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface fair and even (without using extra cement) complete all as specified and as directed by Engineer-in-Charge.
Rendering 5 mm thick in cement and sand mortar 1:4 on cement concrete surfaces of ceiling including finishing the surface even and smooth (without using extra cement) complete all as specified and as directed by Engineer-in-Charge.
M&L for Preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for Preparation of old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for Preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for Preparation of new treated surfaces of walls and applying two coat of cement base paint complete all as specified and directed.
M&L for Preparation of new treated surfaces of walls and applying two coats of oil bound distemper over one coat of 3mm thick wall care putty complete all as specified and directed.
M&L for complete removal of existing old treatment on walls complete all as specified and directed.
Fixing 20mm dia PVC nozzles and injection grouting using heavy duty cementious waterproofing coating as in roof slab all as per manufacturer's instruction complete all as specified and directed.
Applying two coats of heavy duty cementious waterproofing coating as in wall all as per manufacturer's instruction complete all as specified and directed.
S&F structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle or channel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality B complete all as specified.
Restraining,resecuring including making good of loose/disturbed GI snap grid ceiling frame work incl carefully taking down ceiling board and refixing in position (incl replacement of broken board if any) complete all as specified. Note : New ceiling boards shall be measured and paid seperately.
Supply only 4mm thick prelaminated designer ceiling boards.
Taking up or down 15mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by Engineer-in-Charge.
S&F 15 mm GI tube medium grade ISI marked galvanised with all necessary fittings and fixed complete to wall, ceiling or laid in floors complete all as specified and as directed by Engineer-in-Charge.
Taking up or down 20mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by Engineer-in-Charge.
S&F 20mm GI tube medium grade ISI marked galvanised with all necessary fittings and fixed complete to wall, ceiling or laid in floors complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Vitreous china wash basin, white, flat back, size 550x400mm including tap, waste fittings, brass,chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer-in-Charge.
S&F in repair vitreous China wash down water closet pan (Pedestal Pattern) white (excluding flushing cistern and pipe) and trap (standard pattern) complete all as specified and as directed by Engineer-in-Charge.
S&F in repair PVC low level flushing cistern, valveless, syphonic action type, 10 litres capacity with inlet, ball valve float and handle with and including brackets and PVC bend pipe 90 cm long 32mm dia, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair vitreous china oval under counter wash basin (560x470mm), white, complete all as specified and as directed by Engineer-in-Charge.
S&F brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long including brackets complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC connection 15 mm size, of length 450 mm, with PTMT nuts supplied complete all as specified and as directed by Engineer-in-Charge.
S&F in repair steel chromium plated round grating 100mm dia, fixed in position in cement mortar (1:3) complete all as specified.
S&F in repair stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 15 mm, complete all as specified and directed by Engineer-in-Charge.
S&F in repair stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 20mm, complete all as specified and directed by Engineer-in-Charge.
S&F in repair Bib taps, cast copper alloy, fancy type , chromium plated with long body crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, for bore dia of pipe 15mm, complete all as specified and directed by Engineer-in-Charge.
S&F in repair pillar tap cast copper alloy with capstan head chromium plated, fancy type,chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nut, screwed for iron pipe 15 mm bore, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair ball valve high pressure of PTMT with epoxy coated Aluminum rod & high density plastic ball screwed for iron pipe or brass ferrule 20mm bore (minimum weight 210 gms) , complete all as specified and directed by Engineer-in-Charge.
Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down/dismantling existing water tank complete all as specified and directed by Engineer-in-Charge.
S&F mild steel framed work as in grills, grating etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, conforming to Fe-290 Gde-E-165, complete all as specified
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm not exc 4.0 Sqm each complete all as specified and directed.
Taking down shutters of any description, area exceeding 1 sqm and not exceeding 2.00 sqm each complete all as specified and as directed by Engineer-in-Charge
Refixing the shutters area exceeding 1.00 sqm and n.exc 2.00 Sqm each in the same opening complete all as specified and as directed by Engineer-in-Charge.
Pressed steel frames factory made for doors out of 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs, hinges, lock strike plate, hinges etc complete, size of frame 105x60mm including tarring ends and back of chowkats and lugs complete all as specified and as directed by Engineer-in-Charge.
PCC 1:3:6 type C-0 using 12.5 mm graded stone aggregate as in filling of pressed steel frame complete all as specified and as directed by Engineer-in-Charge.
PCC 1:3:6 type C-1 using 20mm graded stone aggregate for hold fast blocks, including necessary form work for rough finished surfaces etc complete all as specified and as directed by Engineer-in-Charge.
S&F 30mm thick, flush shutter, solid core construction, with block board core and pre laminated face veener on both sides fitted to chowkhat complete all as specified and as directed by Engineer-in-Charge.
35mm thick, 2nd class hard wood glazed and skelton door shutter, open rebated and prepare to receive glass, gauzed etc (without sash bars) edges of framming plain , chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR PART I Section 8 clause 8.24(a) supplied and fitted to chowkhat complete all as specified and as directed by Engineer-in-Charge.
250 mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and directed.
200 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed.
Aluminium handles cast type anodised of size 150 mm long ISI marked complete all as specified and as directed.
S&F Steel windows/ventilator (Box type) factory made glass/glazed shutter, (glass panes shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron including box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh no 1/1 to 1/3 .
All as per item No 70 here-in-above but without glazing bars.
S&F 3 mm thick sheet glass, ordinary quality and glazing with silicon sealant in square not exc 0.5 sqm in each complete all as specified and directed.
S&F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, or galvanized wire staples all as specified & directed.
Preparation of old treated surfaces of walls (plastered or unplastered) and applying two coats of Apex emulsion paint with primer as in roof projection/chajjas and pillar projections including removal of existing treatment complete all as specified and directed.
S&F powder coated anodised aluminum door shutters, including framework for aluminum partition including necessary jointing cleats, glazing clips, 5.5mm thick tinted glass, rubber neoprene packing, with locking arrangment with godrej mortice lock of seven levers aluminium tower bolts of size 200mm 02 nos and aluminium handles 02 Nos in each door shutter, floor door spring, anodised aluminum snap beading screws etc complete all as specified.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints "fixed to wall" as in rainwater pipe etc, complete all as specified.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints "laid in trenches or in floor", complete all as specified.
S&F 110 mm bore PVC (SWR) bends any radius all as specified.
S&F 75 mm bore PVC (SWR) bends any radius all as specified.
Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, complete all as shown in drawing of relevant item in MES, schedule Part-II , 2010 as specified and as directed by Engineer-in-Charge.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as shown in drawing of relevant item in MES, schedule Part-II , 2010 as specified and as directed by Engineer-in-Charge.
Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and as directed by Engineer-in-Charge.
Mild steel springs for doors, 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed by Engineer-in-Charge.
Preparation of new untreated wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, and painting with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M&L for Preparation of old wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, and painting with one coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of 8mm thick gypsum board false ceiling decorative vinyl lamination tiles (595x595mm) with aluminum foil backing for thermal insulation over GI snap grid frame work (Grid size 600x600mm) with powder coated GI angle of size 25x25x3mm, main runner 'T' of size 25xc40x3mm , secondary runner 'T' of size 25x30x3mm suspended with 3mm GI wire @ 1200mm c/c including dismantling of existing wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs /blankets any thickness including cover fillets complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:4:8 type D-2, using 40 mm graded stone aggregate, as in subbase of floors and paving finished even and rough complete all as specified.
75 mm thick 75 cm wide PCC type C-1 1:3:6 (using 20mm graded stone aggregate) as in plinth protection laid in bays complete including 75mm thick consolidated hard core of broken stone over rammed earth finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge. Note :- The rate quoted shall be deemed to include for use and waste of form work / screed strips and to divide the area in panels.
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Taking down main switches, distribution boards etc of any capacity along with the existing boards and removing the same from site and making good the disturbed surfaces/portion of walls etc complete all as specified.
M&L for Sub main wiring with two runs of 06 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn through in and including PVC surface conduit or casing caping of 20/30mm, 2.0 mm wall thickness (ISI marked) with all fittings and fixing accessories, surface type on walls, roofs etc including one run of 06 Sqmm FRLS PVC insulated copper conductor for earth continuity wire in green color including taking down carefully existing copper submain wiring with PVC surface conduit or casing caping and making good disturbed surfaces complete all as specified & directed by Engineer-in-Charge. Note:- Two runs of copper conductor 6.0 sqmm and one run of 6.00 Sqmm copper earth wire including PVC casing caping will be measured and paid as one unit (RM) only.
M&L for Sub main wiring with two runs of 04 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn through in and including PVC surface conduit or casing caping of 20/30mm, 2.0 mm wall thickness (ISI marked) with all fittings and fixing accessories, surface type on walls, roofs etc including one run of 04 Sqmm FRLS PVC insulated copper conductor for earth continuity wire in green color including taking down carefully existing copper submain wiring with PVC surface conduit or casing caping and making good disturbed surfaces complete all as specified & directed by Engineer-in-Charge. Note:- Two runs of copper conductor 4.0 sqmm and one run of 4.00 Sqmm copper earth wire including PVC casing caping will be measured and paid as one unit (RM) only.
M&L for Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch, complete all as specified & directed.
All as per Srl item No. 94 here-in-above but for one 3/5 pin 5 Amps socket outlet on same board with other switches.
All as per Srl item No. 94 here-in-above but for one 3/5 pin 5 Amps socket outlet on independent board.
M&L for point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volt grade, single core of 2.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling/false ceiling including cutting chases as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 16 Amps controlled by one switch on independent board, complete all as specified & directed. Notes for Srl Item No. 94 to 97 (i) Unit rate includes for cutting chases whereever required and sinking for boxes, making good to walls / floors etc., complete, including white wash / colour wash as directed. (ii) Uniform coding of wiring i.e red / yellow / blue for phase black for neutral and green for earth is to be maintained.
S&F in replacement socket socket combination outlet 2 in 1, 6 pin type, 5 and 15 Amp, flush type, multipurpose complete all as specified & directed.
S&F in replacement ceiling rose 5 amp, 3 plates polycarbonate body complete all as specified & directed.
S&F in replacement Switch piano flush type 5 Amps 240 Volt, single pole one way, complete all as specified & directed.
S&F in replacement socket socket combination outlet 2 in 1, 2 & 3 pin type, 5 Amp, flush type, multipurpose complete all as specified & directed.
S&F in replacement socket outlet 2 in 1, 5 pin type, 5 Amp, flush type, complete all as specified & directed.
S&F in replacement bell push piano, flush type 5 amps complete all as specified & directed.
S&F in replacement bell ding dong, AC, 230 volt, single pole complete all as specified & directed.
S&F in replacement stepped type electronic fan regulator step type 230 volts suitable for any type of ceiling fan sweep on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
S&F islolator DP 63 Amp, 240V , 10 KA complete all as specified & directed.
S&F islolator DP 32 Amp, 240V , 10 KA complete all as specified & directed.
S&F in replacement sheet metal enclosure for distribution boards, suitable for fixing MCBs 240 volts with 200 Amps rated bus bar, SPN, 12 ways double door type, ISI Marked including blanking plates where required & making good the disturbed surface of wall complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement sheet metal enclosure for distribution boards, suitable for fixing MCBs 240 volts with 200 Amps rated bus bar, SPN, 8 ways double door type, ISI Marked including blanking plates where required & making good the disturbed surface of wall complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement MCB, single pole, (SP) 6 to 32 Amp, AC, 10 KA repturing capacity, ISI marked, 240 Volt, 'C' series, including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCB, triple pole and neutral (TPN), 63 Amps, AC, 10 KA repturing capacity, ISI marked, 415 Volt, 50Hz, 'C' series, including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCB, single pole & neutral, (SPN) 10 to 32 Amp, AC, 10 KA repturing capacity, ISI marked 240 Volt, 'C' series, including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified & directed.
S&F in replacement MCB, single pole & neutral, (SPN) 63 Amp, AC, 10 KA repturing capacity, ISI marked 240 Volt, 'C' series, including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified & directed.
S&F in replacement of steel enclosure, single pole & neutral, (SPN), 240 volt, 4 ways, double door for flush/surface mounting distribution board, factory made and tested complete, protection class IP 36 suitable for mounting MCBs with 200 amps tinned copper bus bar, cable lugs complete all as specified & directed.
Taking down existing ceiling fan for repair and hanging again in position after repair complete all as specified & directed by Engineer-in-Charge.
S&F Earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 metre below normal ground level, surrounded on all sides by 150mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to and including earth lead wire 4.0mm (8SWG) by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electrical plate No 3 of SSR Part-I (2009) including taking down old existing earthing complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified & directed. Note : (a) The cost of earth work, PCC pit of size shown in electrical plate No.3, funnel, watering pipe, wire mesh, charcoal, dust, common salt, 20mm bore medium grade watering pipe & 15mm bore light grade GI pipe as protection to earth lead wire etc shall be deemed included in the unit rate for earthing. (b) After completion, during testing, if the earth resistance equal or less 2 ohms is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
S&F in replacement new generation energy saving and environmental friendly long life LED street light of 20W made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection and impact resistance of IK07 including GI bracket made of 40mm dia light grade GI tube 1.2 metre bend to shape with 02 nos FI clamp of 32x4mm with nuts, bots, washers, making connection with PVC copper conductor cable of appropriate size, complete all as specified & directed. Make : Havells Cat Part No. ENDURAPEARLSL20WLED757SASYTOPCMP or equivalent of Philips/ Crompton Greaves/ Bajaj or equivalent.
S&F in replacement 1x10 W LED lamp complete all as specified and directed. Make: Havells Cat Part No. LHLDERHEML8X010 or equivalent in Philips/ Crompton/ Bajaj/ Wipro/ Syska Led/ GE Lighting/ Surya
S&F in replacement energy saving 10W LED bulk head luminaires, IP-65, oval shape, surface mounted with all other accessories prewired and making connections with copper flexible twisted twin cord of appropriate gauge and length, 230v, 50Hz complete all as specified & directed. Make. Havells, Cat Part No. RUGBYNEONFT10WLED760SSYMBOPC or equivalent in Philips/ Crompton/ Bajaj/ Wipro/ Syska Led/ GE Lighting/ Surya
S&F surface & wall mounted, LED tube light fitting, 20W, glare free, smooth light distribution, 230v, box type, epoxy powder coated CRCA sheet housing with reflector cover channel, aesthetic looking end cap and HPF LED driver with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified & directed. Make. Havells Cat Part No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent in Philips/ Crompton/ Bajaj etc.
S&F surface & wall mounted, LED batten fitting, 20W, 230v, extruded aluminium provided for efficient heat dissipiation with polycarbonate diffuser & integrated electronic driver complete including connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified & directed. Make. Havells Cat Part No. LUMILINEBS20WLED865SPCWH or equivalent in Philips/ Crompton/ Bajaj etc.
Supply, laying and testing XLPE insulated, electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, heavy duty cable, cross-sectional area 10 Sqmm 2 core connected with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipes including taking down old existing unserviceable cable complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Supply, laying and testing XLPE insulated, electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, heavy duty cable, cross-sectional area 16 Sqmm 4 core connected with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipes including taking down old existing unserviceable cable complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Supply, laying and testing XLPE insulated, electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, heavy duty cable, cross-sectional area 16 Sqmm 2 core connected with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipes including taking down old existing unserviceable cable complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep in soft/loose soil for laying of underground cable, foundation of poles & stays etc., and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed by Engineer-in-Charge.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
S&F in repair stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 25 mm, complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm bore Tubes, 'light grade', galvanised, for cable protection fixed on poles or laid in trenches under floor, ducts etc with fixing clamps, nuts, bolts etc complete all as specified and directed.
M&L for 25mm bore Tubes, 'light grade', galvanised, with all fitting; laid in trenches for passing of XLPE cable complete all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .