Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 CrAccepted-AOC D 1 1 GILLANDER HOUSE 8 N S ROAD KOLKATA 700 001 | KOLKATA | WEST BENGAL | 700001 | ₹37.4 Cr Quoted ₹37.5 Cr | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹39.8 CrRejected-Finance C 2488 SUSHANT LOK PHASE 1 GURGAON 122001 HARYANA | GURUGRAM | HARYANA | 122001 | ₹39.8 Cr | L2 | Rejected-Finance Not Being L1 Bidder |
| 3 | L3₹41.0 CrRejected-Finance | ₹41.0 Cr | L3 | Rejected-Finance Not Being L1 Bidder |
| 4 | L4₹42.3 CrRejected-Finance PLOT NO HIG 7 CHUNVATI LANE GOPALGAN BALASORE 756001 | BALESHWAR | ODISHA | 756001 | ₹42.3 Cr | L4 | Rejected-Finance Not Being L1 Bidder |
| 5 | L5₹43.9 CrRejected-Finance 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹43.9 Cr | L5 | Rejected-Finance Not Being L1 Bidder |
Tender Value
₹40 Cr
EMD Value
₹15 L
Closing Date
11 Mar 2024, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVN OF CERTAIN ADM BUILDINGS IN 31 WING AF STATION PANAGARH UNDER GE (P) (AF) PANAGARH
2023_MES_634826_1
88879/PAN/E8
Open Tender
Civil Works
730 days
GE (P) (AF) Panagarh
As per NIT Conditions
8 documents required · 8 mandatory
₹3,000
GE (P) (AF) PANAGARH
₹15 L
Yes
29 Mar 2024
29 Dec 2023
13 Mar 2024
29 Dec 2023
11 Mar 2024
4 Mar 2024
Amount
NOTE (Applicable for all Parts/ Items):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
SCHEDULE "A" Part - I (BUILDING / STRUCTURES WORK ) Details of pre priced Schedule is given in tender documents
SCHEDULE "A" PART-II (EARTH WORK AND SITE CLEARANCE) Details of pre-priced Schedule is given in tender documents
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of pre-priced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of pre-priced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/FOOT PATH/SLAB CULVERT) Details of pre-priced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (AREA DRAINAGE) Details of pre-priced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Details of pre-priced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of pre-priced Schedule is given in tender documents
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIFICATION) Details of pre-priced Schedule is given in tender documents
SCHEDULE "A" PART-X (STREET/SECURITY LIGHT) Details of pre-priced Schedule is given in tender documents
SCHEDULE "A" PART-XI (LIGHTENING PROTECTION) Details of pre-priced Schedule is given in tender documents
SCHEDULE "A" PART-XII (DEMOLITION/DISMANTLING) Details of pre-priced Schedule is given in tender documents
SCHEDULE "A" PART -XIII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
INTERNAL ELECTRIFICATION. S&F Ultra bright LED 24W polycarbonate Tubelight with THD<10% with very high efficacy suited for installation in surface and wall mounted LED batten with Aluminum housing & integrated electronic driver with required accessories, system lumen not less than 2200 lm, power factor > 0.95, colour temp (CCT)-5700K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arragements complete including LEDs with certification LM 79 for luminiare, LM 80 for LED source, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
S&F Ultra bright LED 20W polycarbonate Tubelight with THD<10% with very high efficacy suited for installation in surface and wall mounted LED batten with Aluminum housing & integrated electronic driver with required accessories, system lumen not less than 2000 lm, power factor > 0.95, colour temp (CCT)-5700K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arragements complete including LEDs with certification LM 79 for luminiare, LM 80 for LED source, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
S&F Ultra bright LED 18W polycarbonate Tubelight with THD<10% with very high efficacy suited for installation in surface and wall mounted LED batten with Aluminum housing & integrated electronic driver with required accessories, system lumen not less than 2000 lm, power factor > 0.95, colour temp (CCT)-5700K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arragements complete including LEDs with certification LM 79 for luminiare, LM 80 for LED source, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
S&F Ultra bright LED 10W polycarbonate Tubelight with THD<10% with very high efficacy suited for installation in surface and wall mounted LED batten with Aluminum housing & integrated electronic driver with required accessories, system lumen not less than 1050 lm, power factor > 0.95, colour temp (CCT)-5700K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arragements complete including LEDs with certification LM 79 for luminiare, LM 80 for LED source, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
S&F Ultra bright LED 9W Tubelight with aluminium heat sink & polycarbonate diffuser having high efficacy suited for installation in existing T5 fitting with G5 lamp holders, LED driver outside with surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver and required accessories, system lumen not less than1050 lm, power factor > 0.95, colour temp (CCT)-5700K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arragements complete including LEDs with certification LM 79 for luminiare, LM 80 for LED source, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
S&F LED 9W Surface mounted downlight with white powder coated polycarbonate decorative housing and pressure die-cast heat sink having high efficiency with heavy duty driver having THD<10%. with required accessories, system lumen not less than 1050 lm, power factor > 0.95, colour temp (CCT)-5700K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arragements complete including LEDs with certification LM 79 for luminiare, LM 80 for LED source,connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
S&F surface mounting LED 15W Light fixture which provides soft-light and glare free symmetrical illumination with required accessories, system lumen not less than 1550 lm, power factor > 0.95, colour temp (CCT)-5700K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arragements complete including LEDs with certification LM 79 for luminiare, LM 80 for LED source,connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
S&F LED Bulkhead 10W Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head Back-lit LED luminaire comprising of high brightness LEDs. with required accessories, system lumen not less than 1050 lm, power factor > 0.95, colour temp (CCT)-5700K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arragements complete including LEDs with certification LM 79 for luminiare, LM 80 for LED source,connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
S&F energy saving and environmental friendly long life 20WLED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK-07 wth required accessories system lumen not less than 2200 lm, power factor > 0.95, colour temp (CCT)-5700K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arragements complete including LEDs with certification LM 79 for luminiare, LM 80 for LED source, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
S&F recess mounting luminaire (2' x 2') 36 watt with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling, CRCA powder coated, integrated high efficiency electronic driver with lower THD (< 20 %) , IP 20, CRI >=80, Colour Temp (CCT)- 6500 K, System lumen not less than 4350 lm. Electronic driver & surge suppressor, power factor 0.95, operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including 01 No. 10 W (2 FT) LED lamp or strip high efficiency LEDs as per OEM with viewing angle of 120º with certification LM 79 for luminaire, LM 80 for LED source including all necessary internally pre-wired and connecting up with and including twin twisted flexible copper conductor cable of suitable size ceiling rose to terminal block complete all as specified and directed .
S&F recess mounting luminaire 15 Watts square with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling, CRCA powder coated, integrated high efficiency electronic driver with lower THD (< 20 %), Colour Temp (CCT)- 6500 K, Electronic driver & surge suppressor, power factor 0.90, operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including high efficiency LEDs as per OEM with certification LM 79 for luminaire, LM 80 for LED source including all necessary internally pre-wired and connecting up with and including twin twisted flexible copper conductor cable of suitable size ceiling rose to terminal block complete all as specified and directed .
S&F recess mounting luminaire 12 Watts square with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling, CRCA powder coated, integrated high efficiency electronic driver with lower THD (< 20 %), Colour Temp (CCT)- 6500 K, Electronic driver & surge suppressor, power factor 0.90, operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including high efficiency LEDs as per OEM with certification LM 79 for luminaire, LM 80 for LED source including all necessary internally pre-wired and connecting up with and including twin twisted flexible copper conductor cable of suitable size ceiling rose to terminal block complete all as specified and directed .
S&F recess mounting luminaire 9 Watts square with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling, CRCA powder coated, integrated high efficiency electronic driver with lower THD (< 20 %), Colour Temp (CCT)- 5700 K, Electronic driver & surge suppressor, power factor 0.90, operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including high efficiency LEDs as per OEM with certification LM 79 for luminaire, LM 80 for LED source including all necessary internally pre-wired and connecting up with and including twin twisted flexible copper conductor cable of suitable size ceiling rose to terminal block complete all as specified and directed .
S&Fstreet light fittings bracket made out of 1.0 meter long 40 mm bore GI pipe, light grade, bent to required shape and fixing to building including flat iron clamp of size 40mm x 6 mm fixed with bolts and nuts with washer of suitable size/length as required duly grouted in wall including two coats of aluminum paint over a coat of primer complete all as specified and directed .
S&F Energy efficient five star rated, 26 to 32 Watts, with three blades ceiling fan 230 volts, single phase AC, 1200 mm sweep, BEE 5 star rated, Brushless Direct Current(BLDC) without remote type with accessories like holding down rod,hanging clamps, blades, fan hook including writing MES number (as per standard practice) including provision of three core flexible copper wire of suitable size from ceiling rose to ceiling fan complete in all respect all as specified and directed.
S&F exhaust fan metallic steel body, single phase, 230 volts, 50 Hzs of size 300mm sweep, 1400RPM, copper wound, 3 blade, double ball bearing, heavy duty type with suitable metallic louver, blades, frame and flexible three core copper conductor cable of suitable size for connecting with ceiling rose complete all as specified and as directed.
S&F exhaust fan with louvers 200 mm sweep , AC single phase 240 volts, 50Hz, non metallic, air flow not less than 450 CMPH and connecting up complete including built in louvers and provision of cable 3 core of size 0.5 Sqmm (16/0.2 mm) from ceiling rose to fan complete all as specified and as directed.
M&L for concealed sub main wiring submain wiring for main DBs to Sub DBs/Plug & Sockets with PVC insulated unsheathed FR-LSH cable 1100 volts grade of size 2.5 Sqmm x 2 run alongwith earth continuity wire connected from main earth of size 2.5 Sq mm x 1 run, ISI marked multi stranded copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 25 mm as requried as specified and as directed. Note:- (a) Two runs of 2.5sqmm conductor for main and one run of 2.5 sqmm conductor as earth wire with PVC conduit shall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c) Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles.
M&L for concealed sub main wiring submain wiring for main DBs to Sub DBs/Plug & Sockets with PVC insulated unsheathed FR-LSH cable 1100 volts grade of size 4 Sqmm x 2 run alongwith earth continuity wire connected from main earth of size 4 Sq mm x 1 run, ISI marked multi stranded copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 25 mm all as requried as specified and as directed. Note:- (a) Two runs of 4 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with PVC conduit shall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c) Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles.
M&L for concealed sub main wiring submain wiring for main DBs to Sub DBs with PVC insulated unsheathed FR-LS cable 1100 volts grade of size 6 Sqmm x 2 run alongwith earth continuity wire connected from main earth of size 6 Sq mm x 1 run, ISI marked multi stranded copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 25 mm as requried all as specified and as directed. Note:- (a) Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with PVC conduit shall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c) Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles.
M&L for concealed sub main wiring submain wiring for main DBs to Sub DBs with PVC insulated unsheathed FR-LS cable 1100 volts grade of size 10 Sqmm x 2 run alongwith earth continuity wire connected from main earth of size 10 Sq mm x 1 run, ISI marked multi stranded copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 25 mm as requried all as specified and as directed. Note:- (a) Two runs of 10 sqmm conductor for main and one run of 10 sqmm conductor as earth wire with PVC conduit shall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c) Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles.
M&L for concealed submain wiring with PVC insulated unsheathed FR-LS cable 1100 volts grade of size 6 Sqmm x 4 run alongwith earth continuity wire connected from main earth of size 6 Sq mm x 2 run, ISI marked multi stranded copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 40 mm as requried all as specified and as directed. Note:- (a) Four runs of 6 sqmm conductor for main and Two runs of 6 sqmm conductor as earth wire with PVC conduit shall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c) Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles.
M&L for concealed submain wiring with PVC insulated unsheathed FR-LS cable 1100 volts grade of size 10 Sqmm x 4 run alongwith earth continuity wire connected from main earth of size 10 Sq mm x 2 run, ISI marked multi stranded copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 40 mm as requried all as specified and as directed. Note:- (a) Four runs of 10 sqmm conductor for main and Two runs of 10 sqmm conductor as earth wire with PVC conduit shall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c) Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles.
M&L for concealed submain wiring with PVC insulated unsheathed FR-LS cable 1100 volts grade of size 16 Sqmm x 4 run alongwith earth continuity wire connected from main earth of size 16 Sq mm x 2 run, ISI marked multi stranded copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 50 mm as requried all as specified and as directed. Note:- (a) Four runs of 16 sqmm conductor for main and Two runs of 16 sqmm conductor as earth wire with PVC conduit shall be measured as one unit length. (b) Cutting chases making good distrurbed surface shall be included in the quoted lump sum of Sch A Part -I. (c) Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles.
M&L for Sheet metal enclosure MCB DB, 6 way, SPN, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder coated including earthing etc. as required.complete all as specified and directed.
M&L for Sheet metal enclosure MCB DB double door, 4 way , IP-43, TPN with 200 amps rated bus bar, IP-20 protection, including four pole MCCB 63 Amps with blanking plates complete all as specified and directed.
M&L for 4 way surface/ recess mounting, vertical type, 415 V, TPN MCCB DB of sheet steel, dust protected, duly powder coated, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required complete all as specified and directed.
S&F MCCB four pole, 32 Amps, 16 kA breaking capacity with thermal magnetic release complete all as specified and directed.
S&F MCB TP 32 Amps (C-Curve), breaking capacity 10 kA, 415 volts complete all as specified and directed.
S&F MCB TPN 32 Amps (C-Curve), breaking capacity 10 kA, 415 volts complete all as specified and directed.
S&F MCB 4P 32 Amps (C-Curve), breaking capacity 10 kA, 415 volts with cable connection and copper luging complete all as specified and directed.
S&F MCB 4P 40 Amps (C-Curve), breaking capacity 10 kA, 415 volts with cable connection and copper luging complete all as specified and directed.
S&F MCB 4P 63 Amps (C-Curve), breaking capacity 10 kA, 415 volts with cable connection and copper luging complete all as specified and directed.
S&F MCB Double Pole 40 Amps (C-Curve), breaking capacity 10 kA, 415 volts with cable connection and copper luging complete all as specified and directed.
S&F MCB Double Pole 32 Amps (C-Curve), breaking capacity 10 kA, 415 volts with cable connection and copper luging complete all as specified and directed.
S&F MCB SPN 6-32 Amps (C-Curve), breaking capacity 10 kA, 240 volts with cable connection and copper lugsing complete all as specified and directed.
S&F MCB SP 6 to 32 Amps (C-Curve), breaking capacity 10 kA, 240 volts with cable connection and copper luging complete all as specified and directed.
S&F blanking Plate to cover suitable for MCB DB complete all as specified and as directed.
S&F modular Telephone socket with modular plate and switch box including connections including modular plate etc as required complete all as specified and directed.
S&F modular TV socket with modular plate and switch box including connections including modular plate etc as required complete all as specified and directed.
Supplying and drawing Two pair 0.4 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required complete all as specified and directed.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required complete all as specified and directed.
Supplying and drawing PVC Insulated with RG-59 Co-axial cable copper conductor and PVC outer Sheathed CCTV Camera Cable in the existing surface/ recessed Steel/ PVC conduit as required complete all as specified and directed.
Supply, installation, testing and commissioning of 4U, wall/floor Mountable powder coated Rack with Cable Manager, Power Manager, with Power Distribution Unit, fan, minimum 3 Nos of shelves, Front Glass door with Lock and key complete all as specified and directed.
Supply, installation, testing and commissioning of 2U, wall/floor Mountable powder coted Rack with Cable Manager, Power Manager, with Power Distribution Unit, fan, min 3 nos of shelf, Front Glass door with Lock & key complete all as specified and directed.
Supply, installation, testing and commissioning of 16 PORT 10/100/1000 GIGABIT 16 PORT gigabit switch with 4 SFP SLOT complete all as specified and directed.
Supply, installation, testing and commissioning of 8 PORT 10/100/1000 GIGABIT 8 PORT gigabit switch with 4 SFP SLOT complete all as specified and directed.
Supply, installation, testing and commissioning of 16 Port Patch Panel complete all as specified and directed.
Supply, installation, testing and commissioning of 8 Port Patch Panel complete all as specified and directed.
S & F MDF Telephone Krone DB 50 way in a thermoplastic, enclosure, on wall including cutting, drilling, making hole on wall including cutting of brick work, fixing with cement sand mortar, including finishing the surface with existing finishes complete all as specified and directed.
S&F electric water heater storage type acrylic/ABS body with Copper inner tank and heating element upto 2 KW capacity 25 litre with digital display, vertical type BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, including PVC connection pipe for hot/ cold water to existing water lines,necessary fixing arrangement by using 50 X 5 mm MS plate and writing MES No and paste the instruction sheet of Do’s and DO NOT complete all as specified and as directed.
M & L for Extension of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required, 4mm dia galvanised iron or steel wire complete all as specified and as specified.
ROAD/FOOTPATH/SLAB CULVERT. Material & Labour for 300 mm thick(compacted thickness) GSB (Granular sub base) grade V as per table 400-1 of MORTH, IRC specification, spreading in layers n.exc. 75 mm thick in a single layer over compacted subgrade with natural sand, crushed gravel, crushed stone, crushed slag or combination thereof as per the grading required The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 8 to 15 tonne static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and as directed. directed
Material & Labour for 100mm thick (compacted thickness) Wet Mix Macadam (WMM) in a single layer 100mm thick compacted with crushed stone aggregate of specified grading ,spread using mechanical paver as specified, rolled and consolidated using 8 to 10 tonne capacity tandem vibratory power roller as specified to required gradient and camber to achieve minimum 98% density of MDD determined using modified procter density determination method as per IS 2720(Part-8) and as per MORTH clause 406 for NEW RIGID PAVEMENTcomplete all as specified and as directed.
M&L for preparing bituminous surfaces of road and marking 2.5 mm thick centre lines, stop lines, dashes, arrows etc and the like n exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS-3262-1989 with special applicator machine all as per manufactures instruction complete all as specified and directed.
SEWAGE DISPOSAL Construction Septic Tank for 25 users all as specified and as shown on drawings.
Construction Septic Tank for 50 users all as specified and as shown on drawings.
Construction Septic Tank for 100 users all as specified and as shown on drawings.
M & L Soakage wells for 25 Users, excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and as directed.
M & L Soakage wells for 50 Users, excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and as directed.
M & L Soakage wells for 100 users, excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and as directed.
EXTERNAL WATER SUPPLY. Construction of brick masonry valve pit with sub class ‘B’ brick in CM (1:4) of internal dimension 60cm x 60cm x 60cm depth with one brick wall thick over 15cm thick PCC in foundation with PCC (1:3:6) type C2 using 40mm graded aggregate, PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in bedding and coping including 10mm thick rendering with CM (1:4) complete, 3.15 mm thick MS sheet cover with angle iron framing of size 50mm x 50mm x 6 mm with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on external and internal steel surfaces and two coats of black bituminous paint on hidden steel surfaces including necessary excavation and earth work in any type of soil complete all as specified and as directed.
Construction of brick masonry valve pit with sub class ‘B’ brick in CM (1:4) of internal dimension 90cm x 90cm x 90cm depth with one brick wall thick over 15cm thick PCC in foundation with PCC (1:3:6) type C2 using 40mm graded aggregate, PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in bedding and coping including 10mm thick rendering with CM (1:4) complete, 3.15 mm thick MS sheet cover with angle iron framing of size 50mm x 50mm x 6 mm with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on external and internal steel surfaces and two coats of black bituminous paint on hidden steel surfaces including necessary excavation and earth work in any type of soil complete all as specified and as directed.
Construction of brick masonry valve pit with sub class ‘B’ brick in CM (1:4) of internal dimension 120cm x120cm x 120cm depth with one brick wall thick over 15cm thick PCC in foundation with PCC (1:3:6) type C2 using 40mm graded aggregate, PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in bedding and coping including 10mm thick rendering with CM (1:4) complete, 3.15 mm thick MS sheet cover with angle iron framing of size 50mm x 50mm x 6 mm with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on external and internal steel surfaces and two coats of black bituminous paint on hidden steel surfaces including necessary excavation and earth work in any type of soil complete all as specified and as directed.
M&L for development of trial bore by reaming upto 525 mm for 200 mtrs depth from ground level using any suitable method as per soil condition and CG WB report including disposal of spoil from the site of work complete all as specified and as directed.
Carrying out Electric logging Test of bore for precise delineation of granular zones & also the quality of ground water including report interpretation complete all as specified and as directed. NOTE:- Electric logging shall be carried out by any approved Govt Agency.
Supplying and assembling including jointing, lowering & fixing in position threaded uPVC casing pipe of 250 mm dia nominal size (internal), 12.5 mm wall thickness (Min), Class CM, as per IS 12818 : 2010 (ISI marked) of suitable length including socket and jointing materials and jointing complete all as specified and as directed.
Supplying and assembling including jointing, lowering & fixing in position threaded uPVC casing pipe of 150 mm dia nominal size (internal), 7.5 mm wall thickness (Min), Class CM,as per IS 12818 : 2010 (ISI marked) of suitable length including socket and jointing materials and jointing complete all as specified and as directed.
M & L for packing pea gravel 3 to 5 mm of size as per IS of natural shape brought directly from river bed and packing around the casing pipe of MS to entire depth upto ground level complete all as specified and as directed
S&F MS centralising guide made out of MS flat iron 40x6 mm and 30 cm length all as specified in IS : 2800 (Part – 1) : 1991 complete all as specified and as directed.
Supplying and assembling including jointing, lowering & fixing in position threaded uPVC Screen slotted casing pipe of 150 mm dia nominal size (internal), 7.5 mm wall thickness (Min), Class CM, with slot 0.5 mm as per IS 12818 : 2010 (ISI marked) of suitable length including socket and jointing materials and jointing complete all as specified and as directed.
Supply and fixing well cap suitable for 250 mm bore housing pipe made out of 6 mm thick steel plate complete all as specified and directed. NOTE : After completion of the work well cap will be used to keep the bore well closed until the submersible pumping set is installed.
Development of tube well with air compressor of suitable capacity till sand/mud free water of potable quality is obtained & to achieve minimum discharge capacity of 48000 LPH/max yeild (Compressor with accessories & tube etc. shall be arranged by the contractor) complete all as specified and as directed.
Development of tube well by over pumping 25% using suitable size/type of pump after completion of item above, including yield testing for tube well as per IS requirements complete all as specified and as directed. NOTE :- Yield test of bore well shall be carried out in the presence of rep of Accepting Officer.
Supply only strata sample box with glass cover 3mm thick having internal dimension 1000x600x100mm made out of 20mm thick wrought Ist class hard wood shisham with hinges, hasp and staple including polishing complete with samples at various depth evenly 2 mtr interval met in boring including strata chart in duplicate complete all as specified and as directed.
Testing of water (Raw Water & Treated Water) from approved Govt lab for potability by doing chemical and bacteriological analysis as per norms of WHO and submission of test reports to the to the Dept for entire satisfaction of the Dept.
Supply, lowering, jointing & testing MS Black column pipe 3.0 mtr long, heavy duty, 80 mm bore, wall thickness 4.85 mm, both ends flanged, ISI Marked with heavy duty MS flanges not less than 20 mm screwed & welded inside & outside with pre-drilled holes including jointing with rubber gasket, nuts, bolts, washers & necessary grooves for facilitating submersible cables, steel ropes etc. The pipe shall be duly painted with anti-corrosive paint suitable for drinking water purpose complete all as specified and as directed.
S&F flat submersible cable 3 core 1100 volt grade multi stranded copper conductor PVC insulated, water proof, ISI marked of size 6 sqmm for connecting from starter to bore well submersible pump sets complete all as specified and as directed.
Supply and fixing bail plug of 150 mm internal dia threaded of minimum thickness 6 mm and 3 mtr long made up of mild steel and continuous welded by electric arc welding at both ends complete all as specified and directed.
Supply and fixing chain pully block, triple spur gear, 2 ton capacity with 3 mtr lift, manually operated complete with hooks high tensile forged steel confirming to IS : 3815 and load confirming to IS: 6216 and hand chain to IS: 2429 (Part-I) complete all as specified & as directed
Supply and fixing steel rope flexible 8 mm dia with GI clamps, nuts, bolts, washer etc for fixing of submersible pump set complete all as specified & as directed.
M&L for MS Taper reducer of 250 x 150 mm with and including socket threaded and by electric arc welding both sides complete all as specified and as directed.
S&F mild steel clamp of required length bend to shape suitable for 80 mm dia MS column pipe made out of 12 mm thick MS plate fabricated to shape, including drilling holes, nuts, bolts, washers etc complete all as specified & as directed.
M&L for fabricating of MS nipple 0.6 Mtr long 80 mm dia threaded both side externally. Flanged one end with heavy duty flange drilled four holes and provision of groove for cable entrance system complete all as specified and as directed.
M&L Water Meter Cast Iron body both end flange ISI marked suitable for fixing on 150mm diapipe line including nut, bolt, washer and rubber gasket required for joint all as specified and as directed.
M&L for Water Pressure Gauge dial Type with central knob 4" dia having pressure range 0 to 10 Kg/Sq cm
M&L for rubber or fibre board gasket joints suitable for 80 mm dia flanged pipes including fixing of bolts, nuts, washers complete all as specified and as directed.
Supply only CHLORINE TEST KIT with coloured sample & test-tubes complete with all testing fitments and OT solution in Rexene finish box complete all as specified & as directed
Supply only PH test kit with coloured sample covered under BTB (range 6.0 to 7.0) or phenol red (range 6.8 to 8.4) & test-tubes with necessary fitments and 100 ml testing solution in rexene finish wooden box complete all as specified & as directed
Supply only IRON Test Kit & test-tubes with necessary fitments and testing solution in rexene finish box complete all as specified & as directed
Supply and install testing and commissioning multi stage submersible pump set with bronze impeller, directly coupled with motor, suitable for 250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. Note :- (i) The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test.
Supply and install testing and commissioning of horizontal monoblock pumping Set with suitable capacity motor,voltage range 350 to 440 volts, AC 3 Phase, IP 55 Protection, Insulation class 'F', Mechanical sealing, CI motor and Pump body, SS Pump Shaft, Bronze Impellar alongwith suitable star delta starter and electric connection with 3 Core stranded copper conductor of required size as per OEMsuitable for operation with operating minimum head 40 mtr and having capacity to discharge water 25 Ltrs per Sec with suction and discharge duly mounted on MS frame on foundation / platform grouted with MS bolts, nuts of required size properly connected with suction and delivery water line, complete all as specified and as directed.
Supply, fixing and testing CI Reflux/ Non Return valve single door pattern with flanged ends PN-1.0 confirming to IS: 5312, ISI marked of size 100 mm dia bore with bypass arrangement including all fixing accessoriestype Cast iron flanged end with nuts, rubber gasket, bolts (full threaded), nuts & washers complete all as directed.
Supply and dozing Chlorine tablets contained in plastic cylindrical sealed disposable sanitiser refill for disinfection of drinking water with arrangement for controlled release of disinfectant in water, suitable for operation through recommended dosing system complete all as specified and as directed. Replacement indication: visual & weight variation Water contact orifice design: Sealed when dry, exposed upon immersion. Operation type: Non contact, non inhalatory. Cylinder dia: 2.5 inches ± 0.5 inches Cylinder height: Minimum 10.0 inches ± 0.5 inches
Supply, Laying, Jointing & Testing 250mm dia (Nominal diameter) Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating laid in trenches/floor/wall etc in standard lengths,, ISI marked including push on rubber gasket joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted.
Supply, Laying, Jointing & Testing 200mm dia (Nominal diameter) Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating laid in trenches/floor/wall etc in standard lengths,, ISI marked including push on rubber gasket joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted.
Supply, Laying, Jointing & Testing 150mm dia (Nominal diameter) Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating laid in trenches/floor/wall etc in standard lengths,, ISI marked including push on rubber gasket joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted.
Supply, Laying, Jointing & Testing 100mm dia (Nominal diameter) Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating laid in trenches/floor/wall etc in standard lengths,, ISI marked including push on rubber gasket joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted.
Supply, Laying, Jointing & Testing 80mm dia (Nominal diameter) Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating laid in trenches/floor/wall etc in standard lengths,, ISI marked including push on rubber gasket joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevent items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted.
M&L for fittings ISI marked of size 80 - 200 mm bore suitable for DI pipes class K-12, PN 10, as per IS: 9523 / 2000 with inside cement mortar lining andoutside Zinc coating with finishing layer of Black Bitumen, such as bends (any type radius & angle) tapers, tee pieces, single branches, Y junctions, double junctions, connecting pieces, Nuts & bolts, gaskets, flanges, including push on rubber joints etc. complete all as specified and as directed.
M&L for fittings ISI marked of size 250 -300 mm bore suitable for DI pipes class K-12, PN 10, as per IS: 9523 / 2000 with inside cement mortar lining andoutside Zinc coating with finishing layer of Black Bitumen, such as bends (any type radius & angle) tapers, tee pieces, single branches, Y junctions, double junctions, connecting pieces, Nuts & bolts, gaskets, flanges, including push on rubber joints etc. complete all as specified and directed.
Supply, Installation, Testing & Commissioning of Sluice Valve, ISI marked heavy duty, 250 mm bore complete all as per IS- 14846-2000, PN 1.6 with gun metal spindle non rising type,and one number hand wheel both end flanged and drilled with necessary holes for bolts alongwith jointing materials viz nuts, bolts and gaskets etc all as specified and as directed.
Supply, Installation, Testing & Commissioning of Sluice Valve, ISI marked heavy duty, 200 mm bore complete all as per IS- 14846-2000, PN 1.6 with gun metal spindle non rising type,and one number hand wheel both end flanged and drilled with necessary holes for bolts alongwith jointing materials viz nuts, bolts and gaskets etc all as specified and as directed.
Supply, Installation, Testing & Commissioning of Sluice Valve, ISI marked heavy duty, 150 mm bore complete all as per IS- 14846-2000, PN 1.6 with gun metal spindle non rising type,and one number hand wheel both end flanged and drilled with necessary holes for bolts alongwith jointing materials viz nuts, bolts and gaskets etc all as specified and as directed.
Supply, Installation, Testing & Commissioning of Sluice Valve, ISI marked heavy duty, 100 mm bore complete all as per IS- 14846-2000, PN 1.6 with gun metal spindle non rising type,and one number hand wheel both end flanged and drilled with necessary holes for bolts alongwith jointing materials viz nuts, bolts and gaskets etc all as specified and as directed.
Supply, Installation, Testing & Commissioning of Sluice Valve, ISI marked heavy duty, 80 mm bore complete all as per IS- 14846-2000, PN 1.6 with gun metal spindle non rising type,and one number hand wheel both end flanged and drilled with necessary holes for bolts alongwith jointing materials viz nuts, bolts and gaskets etc all as specified and as directed.
Supply, Installation, Testing & Commissioning of Foot Valve conforming to IS 4038, 100 mm (4”) dia complete all as specified and as directed.
S & F Strainer Y type conforming to IS, size 100 mm (4”) dia complete all as specified and as directed.
Supply, Assembling, Jointing & Fixing in position MS ERW pipe fine cut of internal dia 200 mm bore 2.0 Mtr long of thickness 5.4 mm confirming to IS 4270-2001 (ISI marked) both side flanged and covered with suitable dummy cover including electric arc welding both sides all as specified for header to make branch connections including painting, the pipes with single coat of epoxy primer and two coats of red enamelled paint complete all as specified and as directed.
Supply, Installation, Testing & Commissioning of Air release valve, Cast iron, double air outlet, flanged ends,conforming to IS- 14845, 100 mm bore connected to the main line including all jointing materials as required complete all as specified and as directed.
Supply, Installation, Testing & Commissioning of Air release valve, Cast iron, double air outlet, flanged ends,conforming to IS- 14845, 80 mm bore connected to the main line including all jointing materials as required complete all as specified and as directed.
Supply, Installation, Testing & Commissioning of indoor cubical type LT Control Board, factory fabricated CPRI type tested with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-43 & general construction confirming to IS-13947, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 50 x 50 x 6 mm angle iron suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl PCC platform/plinth of suitable size complete all as specified & as directed with & incl the following accessories :- (LT Panel, Pocket -2, Booster Pump House -3) complete all as specified and as directed:- BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (a) MCCB 4P (Ics = 100% Icu) with adjustable thermal magnetic release, having breaking capaity 16 KA of rating 32 A - 01 No.
Supply, Installation, Testing & Commissioning of indoor cubical type LT Control Board, factory fabricated CPRI type tested with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-43 & general construction confirming to IS-13947, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 50 x 50 x 6 mm angle iron suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl PCC platform/plinth of suitable size complete all as specified & as directed with & incl the following accessories :- (LT Panel for Bore Well) BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos tinned copper 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (a) MCCB 4P (Ics = 100% Icu) with adjustable thermal magnetic release, having breaking capaity 16 KA of rating 32 A - 01 No.
EXTERNAL ELECTRIFICATION Supply, installation, testing and commissioning Vacum Circuit Breaker, Indoor 11 KV of capacity 630 Amps, 3 Phase, 3 wire, 50 Hz, AC supply system, having rupturing capacity 350 MVA at 11 KV, 20 KA breaking capacity, totally enclosed metal clad switch gear as per IEC 62958-1 with overload and earth fault protection, digital ammeter, digital voltmeter, single bus bar for each phase, floor mounting, metal clad, indoor horizontal draw out type, horizontal/vertical isolation type with electrical and mechanical interlock and automatic safety shutter gear including pad locking arrangement, isolation plugs, assembly of 3 vaccum interrupters, with epoxy support insulations and self aligning finger type isolation contacts, truck having integral racking with necessary interlocks (for insertion and withdrawal of VCB),cubical should have not less than IP-43 Class degree of protection, copper bus bar, pre-wired for controller and accessories using copper conductor, suitable for side extension in both directions and provision for cable entry / outgoing system complete, manual and automatic motor charged independent closing/tripping spring,trip free operating mechanism with closing and tripping push bottons and mechanical breakers, including in built battery back up system and all standard fittings for incoming,outgoing including PCC foundation complete and comprising of the following :- (A) HT Vacuum Circuit Breaker Switchgear, Indoor type, dust and vermin proof, motorized as well as manually charged fully interlocked, horizontal draw out type, floor mounted, normal / highest working voltage – 11/12 KV, normal current – 630 A, 3-Phase, 50 HZ AC supply, Breaking capacity - 18.4 KA, Making capacity - 52.5 KA (p), insulation level KV(rms) / KV(p) -28/75, closing voltage – 110 V DC complete as per IS : 3427 & IS : 118 with all standards accessories and metering equipment and comprising the following :-
Supply, installation, testing and commissioning Compact Sub Station (CSS-6) complete all as specified comprising of the following equipments :- (A) OUTDOOR ENCLOSURE Outdoor type enclosure having construction of galvanized steel sheet of thickness 2mm. The enclosure shall have IP 54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure shall be powder coated as per approved colour. Each compartment will be provided with door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided in each compartment. (B) HT SWITCHGEAR (i) HT 11 kV, 630 Amps, 350 MVA, 21 kA for 3 secs, SF6 insulated Non-extensible Compact Switchgear consisting of 01 No. fixed manual Vacuum Circuit breaker as Incomer and 01 No. manual load break switch as Outgoing and 01 No. fixed manual Vacuum Circuit Breaker as Outgoing with microprocessor based self powered relay in SF6 insulated stainless steel enclosure, with series trip, self powered microprocessor based numerical over current relay (IDMT + Inst) protection along with Class 1.0 Metering with interconnection between HT switchgear and transformer with Cable 240 sqmm 3 Core aluminium unarmoured XLPE cable - 01 Set (ii) 11 kV single phase indoor resin cast PT of ratio 11 kV/rt 3/110 V/rt3, lass 0.5-3, Burden 5VA - 50VA, insulation level 28/75 kV, voltage factor 1.2 const and 1.9 for 30 sec, conforming to IS-3156 - 01 Set. (iii) 11 kV single phase indoor resin cast CT of appropriate ratio as per manufactrurer's design, based on load, class 0.5, 5P10, Burden as per manufacturer's design, insulation level 28/75 KV, as per IS-2705 - 01 Set.
Item No 14.30 Contd...... (C) TRANSFORMER (i) 630 KVA, 11 kV/433 V, Dyn11, 3 phase, copper wound insulation class 'F', Natural Air Cooling Cast Resin Dry Type Transformer with off circuit link +5% to -5% @ 2.5 % on HT side of transformer with WTI scanner with Alarm and trip contact and other standard accessories - 01 No. (D) LT PANEL 1500 Amps rated aluminium bus bar for three phase and neutral with PVC sleeves supported on insulators - 04 Nos INCOMING :- (i) ACB, 1000 Amps, 50 kA, 4 pole, rated operational voltage 415-690 V, Manual draw out (MDO) type microprocessor release with LSIG protection unit with over current, short circuit and earth fault protection with LCD display with the manual setting nobs & current measurement on screen and battery back up with over temperature protection and indication for protection unit shunt trip, under voltage release, Terminals, dedicated slots for releases,In Built Temperature Protection, Ics=Icu=Icw rated impulse withstand voltage 12 kV - 01 No. OUTGOING :- (i) MCCB FP, 400 Amps rating, Ics=100%Icu, 50 kA breaking capacity, adjustable thermal magnetic release - 04 Nos ( 01 No Spare) (ii) MCCB FP, 320 Amps rating, Ics=100%Icu, 35 kA breaking capacity, adjustable thermal magnetic release - 01 No. (iii) MCCB FP, 200 Amps rating, Ics=100%Icu, 35 kA breaking capacity, adjustable thermal magnetic release - 02 Nos.( 01 No Spare) (iv) MCCB FP, 160 Amps rating, Ics=100%Icu, 35 kA breaking capacity, adjustable thermal magnetic release - 01 No. (v) MCCB FP, 40 Amps rating, Ics=100%Icu, 25 kA breaking capacity, adjustable thermal magnetic release - 01 No.
Supply, installation, testing and commissioning Compact Sub Station (CSS-5) complete all as specified comprising of the following equipments :- (A) OUTDOOR ENCLOSURE Outdoor type enclosure having construction of galvanized steel sheet of thickness 2mm. The enclosure shall have IP 54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure shall be powder coated as per approved colour. Each compartment will be provided with door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided in each compartment. (B) HT SWITCHGEAR (i) HT 11 kV, 630 Amps, 350 MVA, 21 kA for 3 secs, SF6 insulated Non-extensible Compact Switchgear consisting of 01 No. fixed manual Vacuum Circuit breaker as Incomer and 01 No. manual load break switch as Outgoing and 01 No. fixed manual Vacuum Circuit Breaker as Outgoing with microprocessor based self powered relay in SF6 insulated stainless steel enclosure, with series trip, self powered microprocessor based numerical over current relay (IDMT + Inst) protection along with Class 1.0 Metering with interconnection between HT switchgear and transformer with Cable 240 sqmm 3 Core aluminium unarmoured XLPE cable - 01 Set (ii) 11 kV single phase indoor resin cast PT of ratio 11 kV/rt 3/110 V/rt3, lass 0.5-3, Burden 5VA - 50VA, insulation level 28/75 kV, voltage factor 1.2 const and 1.9 for 30 sec, conforming to IS-3156 - 01 Set. (iii) 11 kV single phase indoor resin cast CT of appropriate ratio as per manufactrurer's design, based on load, class 0.5, 5P10, Burden as per manufacturer's design, insulation level 28/75 KV, as per IS-2705 - 01 Set.
Item No 14.34 Contd...... (C) TRANSFORMER (i) 315 KVA, 11 kV/433 V, Dyn11, 3 phase, copper wound insulation class 'F', Natural Air Cooling Cast Resin Dry Type Transformer with off circuit link +5% to -5% @ 2.5 % on HT side of transformer with WTI scanner with Alarm and trip contact and other standard accessories - 01 No. (D) LT PANEL 600 Amps rated aluminium bus bar for three phase and neutral with PVC sleeves supported on insulators - 04 Nos INCOMING :- (i) MCCB FP, 400 Amps rating, Ics=100%Icu, 35 kA breaking capacity, adjustable thermal magnetic release - 01 No OUTGOING :- (i) MCCB FP, 200 Amps rating, Ics=100%Icu, 25 kA breaking capacity, adjustable thermal magnetic release - 03 Nos ( 01 No Spare) (ii) MCCB FP, 160 Amps rating, Ics=100%Icu, 25 kA breaking capacity, adjustable thermal magnetic release - 01 No. (iii) MCCB FP, 100 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 02 Nos.( 01 No Spare) (iv) MCCB FP, 32 Amps rating, Ics=100%Icu, 16 kA breaking capacity, adjustable thermal magnetic release - 02 Nos.
Supply,install, testing and commissioning out door type LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 40 x 40 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (LTP-17)
M&L for cable route marker made up of PCC block (1:3:6) , Type C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with red colour paint ( HT cable 11/33 KV or LT cable 1100 Volts) on route marker including necessary excavation and earthwork complete all as specified and as directed. NOTE : (i) The spacing between two consecutive cable route indicators shall not be more than 50 meters & also shall be provided at each & every bend or corner. (ii) PCC will be measured and paid separately
STREET LIGHT/SECURITY LIGHT Supply and Fixing 8 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 155 mm, Section Length - 9000 mm, Thickness - 3 mm, Foundation type Base Plate (250 x 250 x 16 mm), Foundation Bolts - 4 Nos 24 mm dia, pitch circle dia 250 mm, bolt length 750 mm, projects bolt length 125 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding complete all as specified and as directed.
Supply and Fixing 8 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 155 mm, Section Length - 9000 mm, Thickness - 3 mm, Foundation type Base Plate (250 x 250 x 16 mm), Foundation Bolts - 4 Nos 24 mm dia, pitch circle dia 250 mm, bolt length 750 mm, projects bolt length 125 mm , with Double type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding complete all as specified and as directed.
Supply and fixing LED street light luminaire 75 Watt Energy saving and environmental friendly long life made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP-65 protection and Impact resistance of IK07 with 10 KV Built-in Surge Protection device with high performance LEDs,System Lumen Efficacy- > 100 Lm/Watt,power factor >=0.90, polyester powder coated with high efficiency polycarbonate UV stabilised cover, tempered protective polycarbonate diffuser, integrated high efficiency electronic driver with lower THD ,Colour Temp (CCT)- 5700 K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including LEDs with certification LM 79 for luiminare, LM 80 for LED source including all necessary internally pre-wired and connecting up complete all as specified and as directed.
Supply and Fixing LED street light luminaire 70 Watt Energy saving and environmental friendly long life made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP-65 protection and Impact resistance of IK07 with 10 KV Built-in Surge Protection device with high performance LEDs,System Lumen Efficacy- > 115 Lm/Watt,power factor >=0.90, polyester powder coated with toughened glass having IP-66 protection, tempered protective polycarbonate diffuser, integrated high efficiency electronic driver with lower THD ,Colour Temp (CCT)- 6500 K operating range - 140 to 270 V, 50 Hz fixed with suitable fixing arrangement complete including LEDs with certification LM 79 for luiminare, LM 80 for LED source including all necessary internally pre-wired and connecting up complete all as specified and as directed.
Supply, Erection, Commissioning and Testing of Galvanized High Mast Light 16 Meter High suitable for 06 Nos. 1 x 200 W LED Flood light and having three point suspension system with steel wire rope of 6 mm did and double drum winch with luminaire mounting arm, 01 No. twin LED type aviation obstruction light including lamp, lightning arrestor spike, power tools including lamp, including excavation for RCC foundation complete with following and all as specified and as directed :- (a) High mast fabricated from steel plates conforming to BSEN-10025/IS:5986, cut and folded to from a polygonal section. Mast shall be in two sections for 16 mtr heights having only longitudinal weld conforming to BS-5135/AWS. The mast is to be provided with a fully penetrated flange which shall be free from any laminations or incursions. The welded connection of the base flange shall be fully developed to the strength of the entire section. The base flange shall be provided with supplementary gussets between bolt holes to ensure elimination of helical stress concentration. For environmental protection of the mast, the entire fabricated mast shall be Hot Dip Galvanized (As per IS:2629) internally and externally having uniform thickness of average 86 microns for bottom / top sections respectively and certificate from the OEM regarding the same to be submitted alongwith the PV and test certificates. The minimum size 410 mm bottom, 150 mm top, 4 / 3 mm section thickness, PCD 490 mm with base plate of 570 X 25 mm with 2 wire rope system and accessories. include Head frame, Lantern ring with 6 nos. of lum arms (symmetrically arrangement), wire ropes, powertool, AOL bracket and 1 set of Foundation Accessories, each set consists of 8 nos.of M 30 x 850 mm bolts with Anchor plate and 10 % templates.
Item No 14.47 Contd...... (b) An adequate door opening shall be provided at the base of the mast. The opening shall be such that it permits clear access to equipment’s lich winch, cable, wire rope, plug and socket etc. and also facilitates easy removal of the winch for servicing. The door opening shall be complete with a close fitting vandal resistant allen key locking with provision for external lock. The door opening shall be carefully designed and reinforced with adequate steel section so that the mast section at the base is unaffected, and undue buckling of the cut portion is prevented under heavy wind condition. (c) Mast structure shall sustain as assumed maximum reaction arising from wind speed as per IS-875 (Part-3) 1987 (three seconds) which is measured at a height of 10 mtrs above ground level. (d) The high mast shall be provided with accessories which include a raising and lowering system (R&L), trailing cable, power tool, lighting finial and aviation obstruction warning light. (e) The wire ropes shall be of stainless steel grade AISI 304 with minimum 6 mm diameter and 7/19 construction. Its central cores shall be also SS and have a minimum breaking strength of 2400 Kgs. The power tool shall be integral type suitable for handling the total head load. It shall have a mechanical torque limiter to ensure safety and also a manual handle shall be provided.
Item No 14.47 & 14. 48 Contd...... (f) Earthing 04 Nos. (02 for FP Box and 02 for High mast) complete with Galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below ground level with the top edge of the earth plate not less than 1.5 mtr below ground level and connected to galvanized iron earth lead strip 32 x 6 mm upto the required length by means of bolts, nuts, check nuts and washer of galvanized iron including PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) precast RCC cover slab including one handle made out of 8 mm dia round bar embedded in precast slab and 20 mm bore medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as shown in EP No. 3 of SSR Part-I and testing on completion complete all as specified and as directed. (g) One number heavy duty hot dip galvanised finial shall be provided for the mast. The lightning finial shall be minimum 1.2 Mtr in length and shall be provided at the centre of the head frame. It shall be bolted solidly to the head frame to get a direct conducting path to the eath through the mast. The mast body acts as a conductor and earth Strip shall be connected to the mast door stiffener.
Item No 14.47 , 14.48 & 14.49 Contd...... (h) Earthing 01 No. (for Surge protection device) complete with Galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below ground level with the top edge of the earth plate not less than 1.5 mtr below ground level and connected to galvanized iron wire 4 mm dia upto the required length by means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) precast RCC cover slab including one handle made out of 8 mm dia round bar embedded in precast slab and 20 mm bore medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as shown in EP No. 3 of SSR Part-I and testing on completion complete all as specified and as directed. (j) The light luminaries shall be 200 W LED, CT>=5700 K made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, surge suppressor 5 KV or more and high brightness LEDs, luminaire efficacy > 110 lumens/Watt, power factor >=0.90, operating range – 140 to 270 V, 50 Hz complete including suitable fixing arrangement , necessary MS angle/clamps, nuts, bolts etc. complete all as per OEM and as specified. (k) The aviation obstruction light shall be LED type with IP 65/66 protection and all as per the recommendations of the OEM complete.
Supply and Laying PVC Insulated PVC sheathed LT cable unarmoured with stranded copper conductor of size 2.5 Sqmm x3 core drawn into steel pole for connection or security/street light fitting from junction box complete all as directed and as specified
Supply,Installation, Testing and Commissioning of LED based Solar street light system stand alone type, on pole (MNRE specification) incl LED street light system of 1 x 36 watt/ nearest higher available rating, system lumen not less than 3150 lm, capable of working on DC 12 volts power from battery unit, being charged by the solar photovoltaic array panel through charge controller, luminaire fixing arm made out of ISI marked GI pipe medium grade of dia 50 mm of length not less than 0.5 mtr with suitable fixing arrangements as per manufacturer etc. The details of different items are as under :- (a) Luminaire :- IP 65, full body, aluminium pressure die cast housing, LED type 1 x 30 W/ nearest higher available rating all as specified and directed suitable for battery system of 12 Volts DC. (b) Maintenance free Lithium Ion Battery 1 No of minimum 12V, 100 AH @ C10 rating (12 Volt system) all as specified and directed. (c) Poly crystalline solar photovoltaic array panel conforming to all relevant IEC/IS standards of best quality. Solar Panel shall be min 125 Wp(12 Volt system). The panel shall be suitably connected to battery through charge controller for its charging all as specified and directed. (d) Solar Charge controller MPPT based conforming to relevant IEC/IS standards shall be provided to charge the battery from solar photo voltaic array panel all as specified and directed including suitable protection mechanism.
Supply,install, testing and commissioning out door type Street light LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB amps rated to MCCB input and MCCB/MCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 40 x 40 x 6 mm duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:-(SLP-3)
STANDBY POWER SUPPLY Supply, Installation, Testing and Commissioning of Silent type built in within an acoustic enclosure Diesel Engine driven Generating set Liquid cooled including AMF panel for standby power supply 415 volts, 3 Phase, 4 wire, 50 cycles / sec,0.8 power factor, 125 KVA (100 KW) or next higher standard size available KVA,1500 RPM. Self exicited self regulated brushless AC generator installed. The alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter 12 volt. Acoustic enclosure suitable for ambient condition at Panagarh and confirming to condition under IS 10002, 13364 Part I 1992, BS 5514/5000 to meet exhaust emission test as per revised MoEF norms/as per CPCB. Fuel tank capacity not less than 08 hours fuel requirement & battery as reccommended by OEM battery leads, sound proof canopy etc. with features for automatic shutdown in the event of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based gen-set controller with the following under-mentioned features complete all as specified and as directed (DG-11):- Note :- The capacity of Generator set shall be net after all due derating factors as per relevant IS/BS Standards design. (A) Alternator :- Standard design alternator rated at 125 KVA / nearest higher available capacity at 0.8 (lag) power factor AC, 3 - phase 4 - wire, 415 volts, 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 5000, IS: 13364 Part I (1992) and shall be in position to generate supply with frequecy regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722.
Item No 14.58 Contd...... (i) Insualation class - 'H' (ii) Temparature rise Class - 'H' (iii) Excitation : Self Excited (iv) Regulation performance: The voltage is kept constant with + 1%. (v) Frequency regulation + 1% (B) Diesel Engine: - Adequate capacity of Diesel engine Liquid cooled to drive independently above alternator and after considering de-rating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS complete, with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- (i) Fly wheel with housing (ii) Cooling system :- Moulded radiator with fan & belts. (iii) Cooling Water pump : - Centrifugal type belt driven. (iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade. MS Exhaust pipe with bends/flanges and all accessories to be supplied and erected as per OEM recommendation. The Exhaust Pipe shall be insulated with low resin bounded wool of min 75 mm thickness min 144 Kg/m density. The dia/thickness and Stack height of the Exhaust pipe shall be as per OEM recommendation and CPCB norms. The minimum height of Stack to be provided with each gererator set shall be worked out as per CPCB norms. Turbo charger type Exhaust manifold Silencer : Residential type
Item No 14.58 & 14.59 Contd...... (v) Fuel System :- Diesel Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electronic operated/ (as recommended by OEM) for 1% speed /frequency regulation. Comprising with Fuel Filters and Fuel Hoses. (vi) Lub oil System :- Comprising of Lubricating oil filter, Lubricating oil pump etc. (vii) Air Intake System :- Air intake Manifold, Air cleaner dry type etc (viii) Governer Electronic type (ix) Starting System :- Electric Self starter with and including battery charging alternator 24 Volts DC. (x) Batteries :- Batteries of maintenance free of capacity 12 V, 180 AH- 02 Nos complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified. (aa) Start and stop push button. (ab) Ignition key / Switch. (ac) Radiator with blower fan & first fill of coolant oil. (ad) Corrosion inhibitor coolant.
Item No 14.58,14.59 & 14.60 Contd...... (xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display. (xii) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine. (xiii) Coupling arrangement : - Flexible coupling. (xiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames. (xv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes as per manufacturer.
Item No 14.58, 14.59 , 14.60 & 14.61 Contd...... (xvi) Fuel Tank :- Daily service fuel tank made complete on a common base inside the acoustic enclosure as per manufacturer guidelines for min 8 hrs continuous operation. (xvii) MS/Steel flexible pipe line to and from the fuel tank to the DG Set. (xviii) Battery Charger shall be provided as per manufacturer guidelines. (xix) The DG Set shall comply to the emission limits requirement as per Govt of India, The DG Set shall be complied with all test requirements as stipulated in the gazette notification. All relevant test results from NABL accredited lab shall be produced. (C) AMF Panel :- Factory made control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally encosed with front and rear opening of 415 volts 3 -phase 4 - wire AC 50 Hz, including powder coated painted, copper bus bar of one and half times the rated load of 125 KVA alternator complete with internal wiring with PVC insulated single core copper condutor multistranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole ACB/MCCBs and Contactors. The size / rating of all the connected accessories viz. Contactors, relays, timers, bus-bars, connecting cables etc. of the AMF Panel shall be in conformity with the I/C and O/G ACBs/MCCBs and as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard fitting shall be as follows:
Item No 14.58 to 14.63 Contd...... (D) Civil Works :- All civil works including PCC plat form and related foundations including for panel and equipments including making good of distrubed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommended by the manufacturer. Note:- The contractor shall arrange for artificial load for testing of DG Set at site and the cost is deemed to be included in the above offer. (E) Acoustic Enclosure:- Manufactured by OEM suitable for 125 KVA DG Set. (i) Tested by NABL approved lab as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board. (iii) The generating set battery should be inside the enclosure. (iv) Fuel tank should be inside the enclosure, however, the fuel storage shall be enough for 8 hrs continuous operation. If required contractor may arrange outside fuel storage capacity to achieve this (v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick (c) Sound Insulation :- 100 mm thick rock wool (minimum density 64kg/Cum)/ fire resistance foam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level. (vi) The acoustic should be composite in construction and fully assembled integral unit. (vii) The DG Set should be provided with external Emergency stop push button. (viii) The enclosure should be suitably internally illuminated by LED fittings. (ix) The noise level should be 75 dB at 1m under free field conditions. (x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The base frame should be painted with epoxy based black shade.
Supply, installation, testing and commissioning of outdoor type LT control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, as per IS -60947 : 2004 double leaf shutter in front and single leaf shutterin rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper bus bar wrapped with PVC tape/sleeves and maintain the colour code and copper strip bus bar as per MCCB/ACB Amps rated to MCCB input and MCCB output of suitable length for connection of cablem from main bus bar. Panel shall be fabricated with 3.15mm thick CRCA sheet and pass through 11 tank process( certificate will be provided by the manufacturer) duly pre-treated and powder coated, framing with MS angle iron 40 x 40 x 6mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external and internal surfaces haveing proper locking arrangement in both front and rear door with four sides slanting roof duly projected, and suitable for 415 V , 50 Hz , 3 Phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provisions of entry of armoured cable of adaquate size with glands. Inner shell shall be compartmentalised for each control gear. Provision of two Nos treaded earthing stood at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC ( 1:3:6 ) type C-2 foundation of suitable size and depth( Minimum 30 cm below ground level and minimum 30cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the floowing accessories :-
Supply,install, testing and commissioning out door type DG LT Control Panel of suitable size, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 40 x 40 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (DGP-6 for 125 KVA DG)
M & L for wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/ recessed as required. (2x2.5 sq. mm +1x2.5 sq. mm earth wire in steel Conduit) complete all as specified and as directed.
S&F for flameproof, Integral LED Flying Saucer LED light fittings 40W including integral reflector made of aluminium alloy LM 6, with electronic driver, connector block etc including LED and all accessories pre-wired with all accessories complete all as specified and as directed.
S & F for Flame Rotary Switch 6A SP with separate terminal junction box dual chamber complete all as specified and as directed.
S & F Flame proof Switch Socket 6A SP with 3-Pin Plug and separate terminal junction box dual chamber complete all as specified and as directed.
S & F heavy duty Flame Proof exhaust fan 450 mm sweep MS Body, 3 wing 1400 rpm, single phase 230/240 volts copper wounds complete with all accessories as louvers shutters etc including making connection through 3 core PVC copper wire run through flexible pipe. Single phase type complete all as specified and as directed.
DEMOLITION/DISMANTLING. Dismantling old barbed wire fencing of any description from RCC/Steel fencing post complete all as directed.
SCHEDULE "A" PART-XIV (SCHEDULE OF CREDIT) Note :- Amount of Rs. 6,63,500.00 shall be deducted from the total quoted amount of BOQ
Ktech Engineer Builders Co. Pvt. Ltd
M/s. Mohan Lal Jain
LIRA CONSTRUCTIONS PVT LTD
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED
NARSINGH DEVELOPERS LLP
NSC Projects Pvt. Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid