Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC | L1 | Accepted-AOC RATES ARE REASONABLE | |
| 2 | L2₹15.5 L+₹3.0 L (24.0%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹15.5 L+₹3.1 L (24.5%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹15.6 L+₹3.1 L (25.0%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹15.9 L+₹3.4 L (27.5%)Rejected-Finance RC MINTRI ROAD KALIMPONG 734301 WB | KALIMPONG | KALIMPONG | WEST BENGAL | 734301 | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹22,000
Closing Date
11 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 WORKS ENGRS
SPL REPAIR TO E OBLIQUE M INSTLN POWER HOUSE AND CONNECTED ITEMS AT RHENOCK AND RONGLI MIL STN UNDER GE 867 EWS 3rd Call
2020_MES_392752_3
CWE/136-WE/63 OF 2020-21
Open Tender
Civil Works
Item Rate
182 days
KALIMPONG
Class C, Category d (v)
8 documents required · 8 mandatory
₹500
Yes
GE 867 EWS
₹22,000
10 Jul 2021
14 Jan 2021
12 Feb 2021
14 Jan 2021
11 Feb 2021
28 Jan 2021
14 Jan 2021 - 21 Jan 2021
60 days
Amount
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed.
Removing excavated material in soft/ loose soil n'exc 50m and depositing where directed at a level n'exc 1.5m above the starting point, complete all as specified and directed.
M&L for sand cushioning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Puned layers shall be measured.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 2 with peak, size 450mm x 180mm x 40mm all as specified and directed.
Returning filling of soil in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil all as specified and directed.
Excavation in post holes each n.exc 0.5 cum getting out in soft loose soils , returning filling in and ramming earth or broken rubble mixed with earth around in layers n.exc25 cm and removing surplus soil to ad distance n.exc 50 m and making good surface all as specified and directed.
Dismantling RCC posts or struts any section, including taking out embedded portion and making good disturbed ground all as specified and directed.
Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for, all as specified and directed.
Demolition of brick work or stone /boulder masonary , built in cement mortar including all quoins , arches ,pillers etc but excluding ashlar facing ,dressed stone work and precast concrete articles all as specified and directed.
Dismantling of chain link fencing, any thickness or mesh ,fixed with steel or wood fillets, if any all as specified and directed.
M&L for PCC (1:4:8) type D-2 (40 mm grade aggrigate ) as in foundation, filling and mass concrete as in post holes all as specified and directed.
S&F for Mild steel plates, plain or chequered, 5mm thick or over in thickness of Fe 410-W (Gde-E- 250) quality- A all as specified and directed.
S&F for framed brackets of angles or tee with web and flanges cut to shape , drilled counter sunk for screw including bending and welding angles gusset plates etc Fe-290 (Gde-E-165) all as specified and directed.
Supply only MS galvanised chain link fencing any type and any type all as specified and directed.
Fixing only MS chain link fencing including line wires, any mesh size any type of standards, rails,straining bolts etc.incl provision of binding wires all as specified and directed.
M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde - E-165) all as specified and directed.
M & L applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces over 10cm width or girth complete all as specified and as directed.
M&L for mild steel in flat iron, in required length, confirming to Fe -410-W (Gde -E-250) of quality-B all as specified and as directed.
S&F for mild steel bolts not exe 12 mm dia in neck, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long all as specified and as directed.
S&F of Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. all as specified and as directed. (each line wire to be measured)
M&L for factory made precast cement concrete block masonary with solid blocks of cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate , exc 10 cm in width and setting in cement morter (1:6) all as specified and as directed.
M&L for 15 mm thick rendering in CM 1:4 on other than fair faces of brick or concrete surfaces of external walls finished even and fair all as specified and as directed.
M&L for prepretion of new plastered surfaces and applying two coats of cement based paint on plastred surfaces on walls all as specified and as directed.
Rubbing/scratching old paint of transformer of capacity upto 200 KVA, through cleaning with kerosene oil and remove all oil stains, dust etc. providing two coats of synthetic enameled spray paint including writing SM/MES/Machine Numbers all as specified and as directed.
Disconnection and Taking out Transformer any capacity from site with the help of chain pully / motorised crain & re-installed at site including testing,commissioning all as directed at site and specified.
M & L for of lightning arrestor metal oxide type confirming to IS-3070 Part 1 complete line discharge (class - 2 nominal discharge current 5 KA & high discharge 65 KA assembly suitable for 11 KV incl all clamps, nuts, bolts & washers & connecting to earth with 32 x 6 mm GI strip complete all as specified and directed.
M&L for air break switch vertical/horizontal rocking type gang operated (GOD) triple pole mechanically operated, mounted on insulators (09 insulators) & steel frame with operating mechanism & operating rod of GI pipe 25mm & medium grade with necessary clamps to be operated from ground level 11 KV grade working pressures and current upto 200 amps and all as specified and as directed.
M & L for Earhing complete with galvanized steel earth plate electrode 600X600X6.3mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to galvanized earth strip size 32x6 mm, by means of galvanized iron or steel bolts, nuts, check nuts and washers, and conneced to equipments as directed, including funnel with GI Light grade watering pipe 20 mm bore, wire mesh charcoal and common salt in alternate layers, of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1, 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia reinforced bar 15 cm C/C and earth lead handle protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc.50m and necessary testing complete all as shown on electrical plate No 3 of MES SSR Part I and all as specified and as directed.
Supplied and spreding graded coarse aggregae 40 mm nominal size all around the structure yard area all as specified and as directed.
Dismantling / Taking out Unserviceable HT cables any size any position i.e ground / walls / poles / culverts etc complete with protection pipe all as specified and as directed.
Dismantling / Taking out unserviceable GI pipe of any size removing material from site complete all as specified and as directed.
Material and labour for replacement of GI tubing of 80 mm bore light grade, complete with all fittings as required for passing through cables under the floor ,along the wall or along the pole with suitable size M.S.flat iron clamps incl nuts, bolts and washers complete all as specified and directed.
Supply, laying, jointing, testing and commissioning HT cable, XLPE insulated, PVC Bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor conforming to IS:7098, cross sectional area 95 sq mm 3 core 11000 Volt complete all as specified and directed. Note- Joint shall be measured and paid separatly.
M&L for outdoor end terminal joints cold shrinkable Suitable for HT 11000V, XLPE insulated armoured Heavy duty under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable of cross sectional area upto 95 Sqmm, 3 Core, all as specified and directed.
M & L danger notice plate of 1.6 mm thick mild steel sheet vitres enameled , white with letter ( in English & Hindi ) Figured & conversional “Skull & Bone” in signal red colour & fixed with MS clamps bolt & nuts of approved size 25 X 20 cm for HT 11 KV, including taking out old unserviceable rusted out danger plate all as specified and directed.
M&L for cutting of PCC floor/plinth/wall/road etc for insertion of GI pipe for protection of LT cable including making good disturbed surface by means of necessary PCC (1:4:8) type D-2 (40 mm grade aggrigate ) as in foundation, filling and mass concrete as in post holes all as specified and as directed. Note: PCC quantity will measured and paid separately.
S & F of Disc type insulator porcelain vitreous white brown or green as per IS 731-1963 of size 145 mm high and 255 dia ball and socketed type single disc with tension clamp for working pressure 11000 volts all as specified and as directed.
S & F of Pin insulator porcelain vitreous white, brown or green insulator as per IS 731`-1963 including one galvanised MS spindle two galvanized iron nuts, washer etc of 150 mm height and 150 mm dia of 11000 volts grade all as specified and directed.
S & F of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed.
M & L for cross arms, bracings, supports clamps etc fabricated from structural steel sections including nuts, bolts, washers welding bending cold or hot drilling holes for bolts any size of shape and including hooks & clamps for aerial bunch cable as indicated and directed and inclusive of two coats of aluminium painting over a coat of red oxide primer all as specified and as directed.
S & F steel tubular swaged pole complete with cast iron base plate, finial taper plug, bots, nuts and screws, pole cap all as specified type 410 SP-55 ( 11 mtr long ) as per IS 2713-1980 all as specified and as directed.
M & L for Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia all as specified and as directed.
M & L for PCC 1:2:4, type C-2 using 20 mm graded crushed stone aggregate for padestal copping incl necessory form work finished fair using extra cement all as specified and as directed.
M & L anti climbing devices, spikes type fabricated out of MS bars (round ,squre ,and flat) including nut bolt , washer and welding in two halves made to shape to suit the cross section of the pole including taking out old unserviceable rusted out anti climbing device all as specified and as directed.
S&F dial type Thermometer suitable for 200KVA Transformer all as specified and as directed.
M&L for aluminium conductor steel reinforced (ACSR) of code word "Rabbit" 6/1/3.35mm number of aluminium strands are 6 suitable for HT line including jointing materials for over head lines complete all as specified and directed.
Note:- The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
SANJAY SAW MILL
MS MAYA PRAKASH GOEL AND SONS
S K ENTERPRISES
C. M. AGARWAL AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .