Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹1.4 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.5 CrRejected-Finance | ₹1.5 Cr | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹1.5 CrRejected-Finance | ₹1.5 Cr | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹1.5 CrRejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | ₹1.5 Cr | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | L5₹1.5 CrRejected-Finance | ₹1.5 Cr | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| Sl No | Description | Qty | Unit | LAKSHMI ELECTRICAL ENTERPRISES L4 | A.GOVINDARAJ L3 | M/S Shiv Shakti Enterprises L1 | Neptune Engineers and Builders L6 | RAMESH BABU CO L2 | UNIVERSAL ENGINEERING L8 | eurekaenterprises L5 | shashi shekar construction L7 | RMK PROJECTS L11 | G K CONSTRUCTIONS L10 | SARAVANA TRADERS L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for taking down of ceiling fan of size 1200/1400mm for safety checking by replacing defective parts/painting/rewinding and re-fixing the ceiling fan after repairs, all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod and winding etc. shall be made as directed by the Engineer-in-Charge which will be measured and paid separately under respective items as Supply only. However, parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement are deemed to be inclusive in quoted rate all as directed. | 685 | Each Job | 350 ₹2,39,750 | 300 ₹2,05,500 | 350 ₹2,39,750 | 475 ₹3,25,375 | 422 ₹2,89,070 | 685 ₹4,69,225 | 320 ₹2,19,200 | 447 ₹3,06,195 | 448 ₹3,06,880 | 400 ₹2,74,000 | 320 ₹2,19,200 |
| 2.00Note:- The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 1. (a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate. | ||||||||||||||
| 3.00(b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work. | ||||||||||||||
| 4.00(c) The entire job will be carried out in AFTC, 2 DC area and Air Force stn Jalahalli | ||||||||||||||
| 5.00(d) Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc will be paid under respective item here-in-after as supply only through proper documentation. | ||||||||||||||
| 6.00(e) Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor's responsibility. | ||||||||||||||
| 7.00(f) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department. | ||||||||||||||
| 8.00(g) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing. | ||||||||||||||
| 9.00(h) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered. | ||||||||||||||
| 10.00(j) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered. | ||||||||||||||
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
17 Apr 2026, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT OF CEILING FANS EXHAUST FANS WALL MOUNTED FANS GEYSERS SOLAR WATER HEATERS CONDUIT DUCT FOR ELECTRICAL COMMUNICATION MEDIA CABLES SUBMAIN WIRING MAIN DBS UNSV MCBS BLDG EARTHING AND CERTAIN MISC EM WORKS AT AFTC 2 DC AREA CQAE WE
2026_MES_757122_1
8303/E8
Open Tender
Civil Works
180 days
Garrison Engineer M AF Jaalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Garrison Engineer M AF Jalahalli
₹2.2 L
Yes
30 Apr 2026
20 Mar 2026
24 Apr 2026
20 Mar 2026
17 Apr 2026
10 Apr 2026
20 Mar 2026 - 27 Mar 2026
Material and labour for taking down of ceiling fan of size 1200/1400mm for safety checking by replacing defective parts/painting/rewinding and re-fixing the ceiling fan after repairs, all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod and winding etc. shall be made as directed by the Engineer-in-Charge which will be measured and paid separately under respective items as Supply only. However, parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement are deemed to be inclusive in quoted rate all as directed.
Note:- The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 1. (a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate.
(b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
(c) The entire job will be carried out in AFTC, 2 DC area and Air Force stn Jalahalli
(d) Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc will be paid under respective item here-in-after as supply only through proper documentation.
(e) Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor's responsibility.
(f) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
(g) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(h) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
(j) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
Supply only fan bearing suitable for ceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF
Supply only gun metal bush of suitable size for ceiling fan 1200mm /1400 mm sweep complete all as specified and directed.
Supply only rotor of ceiling fan of any size complete all as specified and directed.
Supply only 'U' clamp for hanging ceiling fan with all nuts, bolts and washers complete all as specified and directed.
Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm complete all as specified and directed.
Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed.
Supply only fan canopies for ceiling fan size of 1200mm/1400mm complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only safety pins 40mm to 50mm long with nuts and bolt with washers for ceiling fan of size 1200/1400mm complete all as specified and directed.
Supply only blades (made of aluminum) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specified and directed .
Supply only down rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only outer body of ceiling fan of any size complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only blades (made of aluminum) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specified and directed.
Refixing existing serviceable ceiling fans 1200/1400 mm sweep servicing, painting. of ceiling fan with one coat of synthetic enamel paint by spraying including greasing/oiling, filling cavities with filler after cleaning all dust etc. complete all as specified and as directed by Engineer-in-Charge. Note : cost includes for replacement of rubber bush ,hanging hook with new cotter pins etc
Supply and fixing in replacement of unserviceable Ceiling fan 1200mm sweep, energy efficient ISI marked with star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and suitable flexible copper cable not less than 0.5 m long complete writing MES No. with synthetic enamel paint complete all as specified and directed. Make : Havells/ Bajaj/ Orient Note:- (a) Old Unserviceable ceiling fan shall be deposited to MES store yard by the contractor.
Taking down of exhaust fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) are deemed to be inclusive in quoted rate all as specified and as directed. Note:- (a) Rewinding, and materials to be replaced are measured separately.)
(b) The above job shall be carried out by a trained electrician having qualified in ITI (electrician Trade), documentary proof of the education of tradesman shall be produced to Engr-in-Charge before commencement of work.
(c) The entire job will be carried out in AFTC, 2 DC area and Air Force stn Jalahalli
(dc) Defective unserviceable part like fan bush, bearing etc. will be paid under respective item here-in-after as supply only through proper documentation.
(e) Necessary T&P such as ladder, helper shall be contractor responsibility.
(f) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department.
(g) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(h) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
(j) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
Supply only 3.15 mfd capacity exhaust fan condenser complete all as specified and directed.
Supply only fan bush of suitable size for exhaust fan of the any sweep complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 250mm sweep including greasing complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 250mm sweep complete all as specified and directed.
Supply only 2.5 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 300mm sweep including greasing complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 300 mm sweep complete all as specified and directed.
Supply only 4 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 450mm sweep including greasing complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 450 mm sweep complete all as specified and directed.
Material and labour for winding of Exhaust fan 250 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Supply and fixing Exhaust fan 250 mm sweep with louvers ,copper winding 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
M&L for cutting of hole through stone wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.
M&L for cutting of hole through brick wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.
M&L in repair for stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/wooden beading fixed on wall including necessary fixing arrangement up to height 11 mtr complete all as specified and directed. Note : All safety measures shall be the responsibility of the contractor
M&L for in repair louver made of steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtr complete all as specified and directed. Note : All safety measures shall be the responsible of the contractor.
Supply and fixing Exhaust fan 300 mm sweep with louvers ,copper winding 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Material and labour for winding of Exhaust fan 300 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Supply and fixing Exhaust fan 300 mm sweep with louvers ,copper winding 230/ 240 volt AC single phase Metal body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Material and labour for winding of Exhaust fan 450 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Supply and fixing Exhaust fan 450 mm sweep with louvers ,copper winding 230/ 240 volt AC single phase Metal body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Taking down of wall mounted/Pedastal fan of size 400/450mm after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling . (Note:- Repair, rewinding, over hauling and materials to be replaced are measured separately.)
Supply only fan bush of suitable size for wall mounted/Pedastal fan of the any sweep complete all as specified and directed.
Supply only fan bearing of suitable size for wall mounted/Pedastal fan of 400 mm sweep complete all as specified and directed.
Material and labour for winding of wall mounted fan 400 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of sizenot less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Material and labour for winding of wall mounted/Pedastal fan 450 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Supply and fixing of Wall mounted fan metal body 450 mm sweep energy efficient, high speed, single phase, 50 Hz, 230 Volts, copper winding conforming to ISI complete with necessary connection upto ceilling rose including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /Bajaj/ Crompton Greaves Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Taking down carefully copper/aluminum point wiring (light, fan, Power) complete fittings such as switches , ceiling roses pendents , regulators sockets light fittings etc and making good disturbed surface of wall, floors , roof etc all as specified and directed.
M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealed rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame , concealed in wall and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/Havells Note: Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
All as per item No. 64 here in before but for one light point controlled by one way switch.
All as per item No. 64 here in before but for one Exhaust fan/ceilling fan controlled by one by one way switch.
All as per item No. 64 here in before but for one bell point controlled by one bell push.
All as per item No.64 here in before but for one 3 pin socket outlet 5/6 Amp on the same board
All as per item No. 64 here in before but for one switch socket outlet 3 pin 5/6 Amps on independent board
All as per item No. 64 here -in - before but for One light point controlled by two, two way switches.
All as per Sl No 64 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor (FRLS) controlled by one 15/16A switch socket independently complete all as specified and directed.
Supply and Fix switch piano flush type 5/6 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 15/16 Amps 240 volts complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 5/6 Amps 240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 5/6 Amps 240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered socket outlet 3 pin 5/6 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered switch socket outlet 3 pin 5/6 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5/6 and 15/16 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian
S&F fan regulator stpped type electronic for ceiling fan complete all as specified and directed.
S&F Sub main wiring with 2 runs of single core, 1.5 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 1.5 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. (Note : Two runs of cable and one run of earth wire including PVC conduit /Casing capping shall be measured as one run length) Make : Havells/ Polycab/ Plaza
S&F Sub main wiring with 2 runs of single core, 2.5 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 2.5 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. (Note : Two runs of cable and one run of earth wire including PVC conduit /Casing capping shall be measured as one run length) Make : Havells/ Polycab/ Plaza
S&F in repair factory made powder coated distribution board SPN 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S&F in repair factory made powder coated distribution board SPN 6 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F MCB single pole 240 volts upto 40 Amps 'C' series 10 KA breaking capacity complete complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian.
S&F in repair factory made powder coated distribution board TPN, 4 way double door MCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete complete all as specified and directed. Make : Indoasian/ Havells/ Legrand.
S & F TPN, MCB 40 to 63 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
Supply and fix in repair 1100 Volts grade heavy duty flat weather proof twin core cable of size 4 Sqmm with multistrand aluminium conductor complete all as directed and specified .
Supply and Fixing in repair PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 Sqmm three core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza
Supply and Fix Rigid non-metallic PVC cable trunking of size 100X50 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks incl taking down old all as specified and complete all as directed.
M& L in repair PVC Casing & Capping medium grade of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed.
M& L in repair PVC Casing & Capping medium 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed.
S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 4"x 4" all as specified and directed.
S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 6"x 4" all as specified and directed.
S & F in repair Modular flush metal box 1/2 module in the existing wall complete all as directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate.
S & F in repair Modular PVC box 1/2 module in the existing wall complete all as directed.
S & F in repair Modular flush metal box 3 module in the existing wall complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate.
S & F in repair Modular PVC box 3 module in the existing wall complete all as specified and directed.
S&F in repair Sub main wiring with 2 runs of single core, 4 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 4.00 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. (Note : Two runs of cable and one run of earth wire including PVC conduit /Casing capping shall be measured as one run length) Make : Havells, Polycab, Plaza
S&F in repair Sub main wiring with 2 runs of single core, 6 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 6.00 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. (Note : Two runs of cable and one run of earth wire including PVC conduit /Casing capping shall be measured as one run length) Make : Havells, Polycab, Plaza
S&F in repair factory made powder coated distribution board SPN 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F MCB SPN 240 volts upto 40 Amps 'C' series 10 KA breaking capacity complete fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian.
S&F in repair factory made powder coated distribution board SPN 12 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F MCB SPN 240 volts 63 Amps 'C' series 10 KA breaking capacity complete complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian.
Taking down of old U/S earth enclosure with MCB any type complete all as specified and directed.
S&F of Single pole and neutral enclosure with a two pin and earth plug and socket with single pole MCB 32 Amps complete all as pecified and directed. Make Legrand /Schneider /ABB
Supply and Fix triple pole and earth enclosure with a three pin and earth plug and socket complete with one triple pole MCB 10A- 63 Amps with accessories complete all as specified and as directed. Make Legrand /Schneider /ABB
Supply and fix in repair 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor complete all as directed and specified .
Supply and Fixing in repair PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 4.0 Sqmm three core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza
M&L Inspection, checking adjustments and minor repairs of storage water heater 25/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :- (a) Inspection, taking out of drain plug & dewatering and re-fixing the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix.
Note : The following deemed to be inclusive in quoted rate :-
The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work.
The entire job will be carried out in AFTC, 2 DC area and Air Force stn Jalahalli
All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
In case of minor defects, entire job shall be completed with in 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
Supply and fixing Heating element 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed.
Supply and fixing in replacement thermostat switch range of 30-80 degree celsius suitable for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed.
Supply and fixing PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe including taking down existing one complete all as specified and as directed.
Supply and fixing in replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
Supply and fixing Indicator lamp for geyser 25/50 ltr capacity of colour green & red complete all as specified and as directed.
Supply and fixing Heating element 2.0 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity ,any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed.
Supply and fixing in replacement pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed.
Supply and fixing Outer body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enamelled paint including taking down existing one complete all as specified and as directed.
Material and labour for Cutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc including taking down existing one complete all as specified and directed.
Supply and fixing in replacement brass non return valves, screwed down, high pressure, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed.
Material and labour for Grouting 4 Nos of M12 X100mm bolt in stone /brick masonry wall with 1:4 CM suitable for hanging geysers complete all as specified and as directed.
Taking down carefully storage water heater (geyser) 25 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixing in repair of heavy duty pin type fastener 4" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed. Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.
Supply and install water heater storage type (Geyser) vertical of capacity 25 Ltr, suitable for high pressure up to 8 bar powder coated metal body, temperature indicating dial , glass line coated tank, magnesium anode, efficient long life copper heating element, wattage 2 KW electrically operated, AC 230 Volt, BEE 5 Star Rated with complete fittings/parts and accessories for fixing on wall/surface all as per site requirement and specified and directed . Note:- Old Unserviceable water heater shall be deposited to MES store yard. Make:- Bajaj / Racold / Havells
Material and labour for painting of outer surface of 25 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
Taking down carefully storage water heater (geyser) 50 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixing in repair of heavy duty pin type fastener 4" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed. Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.
Supply and install water heater storage type (Geyser) vertical of capacity 50 Ltr, suitable for high pressure up to 8 bar powder coated metal body, temperature indicating dial , glass line coated tank, magnesium anode, efficient long life copper heating element, wattage 2 KW electrically operated, AC 230 Volt, BEE 5 Star Rated with complete fittings/parts and accessories for fixing on wall/surface all as per site requirement and specified and directed Make:- Bajaj / Racold / Havells Note:- (a) Old Unserviceable geyser shall be deposited to MES store yard by the contractor.
Material and labour for painting of outer surface of 50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No. on the geyser complete all as specified and as directed.
Supply and fixing in repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair Chlorinated PVC (CPVC)Gate Valve of size 20 mm dia, (ISI marked) complete all as specified and as directed.
Supply and fixing in repair 25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair Chlorinated PVC (CPVC) Gate Valve of size 25 mm dia,( ISI marked) complete all as specified and as directed.
Supply and fixing 15 mm dia Stop valves, fancy type, chromium plated with long shank and cup(concealed type),screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S & F of bib tap cast copper alloy chromium plated, fancy type screwed down with screwed both ends for iron pipe 15 mm bore complete all as specified and as directed.
Dismantling carefully solar storage water heating system of 100/200/300 Ltr capacity any type for following works with testing and refixing the same in original position making all water/ electric connection to entire satisfaction of Engineer-in-charge after repair as under :-(a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank. (b) Checking water tightness of storage tank after cleaning. (c) Checking and correcting earth continuity of electrical items. (d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (e) Replacement of damaged solar cells (f) Necessary T&P such as ladder, helper shall be contractor responsibility.
Note : The following deemed to be inclusive in quoted rate :-
The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge, before commencement of work.
The entire job will be carried out in AFTC, 2 DC area and Air Force stn Jalahalli
All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
Necessary T&P such as ladder, helper shall be contractor responsibility.
In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 100/- per job shall be recovered.
In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @ Rs. 500/- per day shall be recovered.
Supply and replacement of solar tube as per existing type complete all as specified and directed.
Supply and fixing in replacement thermostat switch suitable for solar water heater of any make and size complete all as specified and as directed.
Supply only solar cells to replace the damaged cells in the solar panel for solar water heater 200 Ltr capacity complete all as specified and directed.
S&F Gasket set for solar water heater panel suitable for 100Ltr capacity complete all as specified and directed.
S&F Hose pipe for solar water heater panel suitable for 200/100Ltr capacity complete all as specified and directed.
S&F in replacement Pressure switch of pressure pump suitable capacity of 0.5 HP to 1 HP complete all as specified and directed.
Supply and fixing in replacement bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, complete all as specified and as directed.
Supply and Fix in replacement of solar water heater tank 100 ltr capacity tank should be 1.60 mm thickness low carbon steel with porcelain coating, outer tank should be 0.4 mm thickness stainless steel 202 grade Non Magnetic grade, insulation in PUF 50mm including provn for suitable solar tubes complete all as specified and directed. Note :- Solar tubes shall be measured and paid separately
Supply and fixing in replacement gate valve , cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 25 mm bore iron pipe, ISI marked, complete all as specified and as directed.
Supply and replace solar panel glass suitable for 100 ltrs capacity solar water heater with gasket complete all as specified and directed.
Supply only solar cells to replace the damaged cells in the solar panel for solar water heater 100 Ltr capacity complete all as specified and directed.
Supply and fix in replacement rotational moulded polyethylene water storage tank of 300 litres capacity three layered HDPE water storage tanks cylindrical vertical with closed top as per IS 12701-1996 hoisted and fixed in position, including provn of inlet pipe, over flow pipe, washout pipe etc complete all as specified and directed.
Material and labour for Staging / steel frame work for Solar water tanks using standard mild steel sections like angle iron / MS pipe / flat iron / sheets etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable to keep 300 ltrs PVC water tank in repairs complete all as specified and directed.
Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connection complete all as specified and directed..
Supply and fixing 20 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connection complete all as specified and directed..
Supply and fixing in repair 20 mm dia PPR Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair PPR Gate Valve (brass insert) of size 20 mm dia, (ISI marked) complete all as specified and as directed.
Supply and fixing in repair 25 mm dia PPR Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair PPR Gate Valve (brass insert) of size 25 mm dia,( ISI marked) complete all as specified and as directed.
Supply and fixing in repair 32 mm dia PPR Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair PPR Gate Valve (brass insert) of size 32 mm dia,( ISI marked) complete all as specified and as directed.
Supply and fixing in repair 40 mm dia PPR Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair PPR Gate Valve (brass insert) of size 40 mm dia,( ISI marked) complete all as specified and as directed.
S&F Sub main wiring with 2 runs of single core, 10 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 6.00 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. (Note : Two runs of cable and one run of earth wire including PVC conduit /Casing capping shall be measured as one run length) Make : Havells/ Polycab/ Plaza
M&L in repair Sub main wiring with 4 runs of 4 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 6 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete as specified and directed. Note : Four runs of cables and one run of earth wire including PVC conduit/ casing capping shall be measured as one run length) Make : Havells/ Polycab/ Plaza
Supply and fix 4 Pole MCCB, 415 volts, fixed type, 160 Amp, 50 Hz, with rupturing capacity 25 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder pillar box including connecting lugs with busbar and mounting arrengments i.e screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed. Make : Indo Asian/L&T/Havells
M& L in repair PVC conduit medium grade of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed.
M& L in repair PVC conduit medium grade of size 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed.
M&L for Cutting chases, pinning in brick wall making good to facings where required in brick wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
M&L for Cutting chases, pinning in. making good to facings where required in brick wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed.
S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 6"x 8" all as specified and directed.
S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 8"x 8" all as specified and directed.
S & F in repair Modular flush metal box 4 module in the existing wall complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate.
S & F in repair Modular PVC box box 4 module in the existing wall complete all as specified and directed.
S & F in repair Modular flush metal box 6 module in the existing wall complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate.
S & F in repair Modular PVC box box 6 module in the existing wall complete all as specified and directed.
Supply and fix in repair 1100 Volts grade heavy duty flat weather proof twin core cable of size 10 Sqmm with multistrand aluminium conductor complete all as directed and specified .
Supply and Fixing in repair PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 6.0 Sqmm three core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza
M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including rigid non metalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & matching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame, concealed in wall and 1.5 sq mm multi stranded copper conductor FRLS cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/Havells Note: Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
All as per item No. 185 here in before but for one light point controlled by one way switch.
All as per item No185 but for One ceiling fan /exhaust point controlled by one switch one way 5/6 Amps and fan speed regulator
All as per item No. 185 here in before but for one bell point controlled by one bell push.
All as per item No. 185 here -in - before but for One 2/3 pin switch socket point controlled by 5/ 6 Amps switch on Independent board.
All as per item No 185 but for One socket outlet point 5/6 Amps 3 pin on same board.
All as per item No. 185 here -in - before but for One light point controlled by two, two way switches.
All as per item No.185 here -in - before but for One 3 pin switch socket outlet combination, 15 Amps, with cables 4 sq mm all as specified and directed.
Supply and Fix modular switch 1 way 5/6 Amp,1 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 1 way 15/16 Amp,1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular Socket,5/6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular Socket, 5/15/ and 6/16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 2 way 5/6 Amp, 1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular bell push 5/6 Amp,1 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian
S&F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directed.
Supply & fix of ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and as directed.
Supply & fix electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/Havells/L&T/ Indoasian
Supply and Fixing in repair 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . The luminaire and driver shall be BIS approved, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
Supply and fixing building security/ LED street light fitting 35/36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG
S & F in repair street light bracket made up of GI tubing 32 mm dia light grade of length 1.0 mtr bent to a shape with 2 Nos suitable clamp incl nut, bolt and washer for fixing on wall complete all as specified and directed.
M&L in repair Sub main wiring with 4 runs of 6 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 6 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete as specified and directed. Note : Four runs of cables and one run of earth wire including PVC conduit/ casing capping shall be measured as one run length) Make : Havells/ Polycab/ Plaza
M&L in repair Sub main wiring with 4 runs of 10 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 10 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete as specified and directed. Note : Four runs of cables and one run of earth wire including PVC conduit /Casing capping shall be measured as one run length) Make : Havells/ Polycab/ Plaza
S&F factory made powder coated distribution board VTPN, 4 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB with fitting fixture complete all as specified and directed. Make : Indoasian/ Havells/ Legrand.
S&Fdistribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian
M& L in repair PVC Flexible conduit of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /alluminium conductor complete all as specified and as directed.
M& L in repair PVC Flexible conduit of size 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /alluminium conductor complete all as specified and as directed.
Supply and Fixing in repair 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . The luminaire and driver shall be BIS approved, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
S&F 35/36 W( WW/WH) LED recess /surface type 2x2 ft luminaire with classic design & glare free soft illumination. housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. Make : Philips/ Bajaj /CG/Havells.
S & F in repair modular PVC White cover plate with frame, 2 module
S & F in repair modular PVC White cover plate with frame, 3 module
Supply and fix in repair PVC White cover plate with frame,4 module
Supply and fix in repair PVC White cover plate with frame,6 module
Supply and fix in repair PVC White cover plate with frame,8 module
Supply and fix in repair PVC White cover plate with frame,12 module
S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 8"x 12" all as specified and directed.
S & F in repair Modular flush metal box 8 module in the existing wall complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate.
S & F in repair Modular PVC box box 8 module in the existing wall complete all as specified and directed.
S & F in repair Modular flush metal box 12 module in the existing wall complete all as specified and directed. Note : Concealed the Modular flush metal box on wall all including making good and matching with existing surface included in the quoted rate.
S & F in repair Modular PVC box 12 module in the existing wall complete all as specified and directed.
S & F in repair Modular blank plate one module complete all as specified and directed.
Supply and Fixing of wall focus track light 16/18 watt WW an operating voltage range from 140V-270V complete all as specified and directed.
Supply and Fixing in repair of channel 2 Mtr length for focus track light complete all as specified and directed.
S & F 7 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton
S & F lamp holder, insulated body/PVC Polycarbonate , cord grip pattern SP 230 Volt, complete all as specified and as directed.
Supply & fix electric gong bell, AC 230 volt, single pole type complete all as specified and directed. Make : Anchor/Havells/L&T/ Indoasian
M&L in repair of fabricated sheet metal board of building panel complete with locking arrangement, fabricated out of 2.0 mm thick MS sheet with powder quoted internal and external surfaces including taking down old unserviceable rusted sheet metal enclosure complete all as specified and directed. Note:- (a) Size Shall be decided as per site requirement.
M&L in repair of fabricated sheet metal board of building panel /LT Panel complete with locking arrangement, fabricated out of 3.0 mm thick MS sheet with powder quoted internal and external surfaces including taking down old unserviceable rusted sheet metal enclosure complete all as specified and directed. Note:- Size Shall be decided as per site requirement.
M&L Taking down of serviceable MFM/volt meter/Ammeter of 1 to 2 Nos of any type, MCB TPN /SPN of 1 to 2 Nos , MCCB TPN /4 Pole of 1 to 2 Nos from the rusted LT panel / Feeder pillar Box and refixing the same in same day after replacement of the new fabricated frame of LT panel / Feeder pillar Box and complete all as specified and directed. Note:- Cost of PCC foundation is deemed to be included in the unit quoted rate.
M&L Taking down of serviceable energy meters 4 to 6 Nos of any type , MCB TPN /SPN DB with MCB of 1to 2 Nos , MCCB TPN DB with MCCBs of 1 to 2 Nos from the rusted building main panel and refixing the same on same day after replacement of the new fabricated building main panel complete all as specified and directed. Note:- (a) Concealed the DBs on wall all including making good and matching with existing surface is inclusive in the quoted rates.
S&F in replacement MFM digital type to measure both current and voltage(V,I) complete all as specified and directed.
Supply and fixing in repair of Aluminium Bus Bar of existing Size in the existing panel board on site of required shape post insulator with removing and refixing of existing UG cable complete all as specified and as directed .
Supply and fixing in repair of copper Bus Bar of existing Size in the existing panel board on site of required shape post insulator with removing and refixing of existing UG cable complete all as specified and as directed.
Supply and fixing in repair LED Indicating lamp (R-Y-B) complete all as specified and as directed .
Supply and fix 4 Pole MCCB, 415 volts, fixed type, 250 Amp, 50 Hz, with rupturing capacity 25 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder pillar box including connecting lugs with busbar and mounting arrengments i.e screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed. Make : Indo Asian/L&T/Havells
Supply, installation, testing and commissioning LT Feeder pillar box double door CPRI Tested of Size 400X250X350mm suitable for 3 phase 415 Volts of suitable size out door made out 3.15mm thick CRCA sheet of outdoor of panel with angle iron frame of size 32x32x5mm cubical type complete with aluminium bus bar 100 Amp and including PCC foundation as per site requairment to accomodated to the following. INCOMING (a) MCB TPN 32 Amp 10 KA - 01 No. (b) LED indicating lamp R-Y-B - 03 Nos. OUTGOING (a) Weather Proof panel Plug and shocket angled type IP 67 three Phase 3P+N +E, 20 Amp - 01 No (b) Weather Proof plug and shocket angled type IP 67 Single Phase 2P+E , 20 Amp - 01 No. (a) MCB TPN 20 Amp 10 KA - 01 No. (a) MCB SPN 20 Amp 10 KA - 01 No.
Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth and getting out insoft/lose soil , complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed.
Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
Material and labour for well burnt bricks ‘B’ class as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed. (iii) Removing excavated material out side MD land. (iv) Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Supply only of GI pipe light grade for cable protection of size 50 mm bore with fittings, complete all as specified and directed.
Material and labour in repair for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 95 Sqmm to 120 Sqmm 3.5 core of underground LT armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
Supplying, transporting, errecting and fixing steel tubular swaged welded pole of over all height 9.00 m long complete type 410-SP-31 conforming to IS-2713 (Part I to III 1998 with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., complete all as specified and directed by Engr-in-charge. Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of block and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of alu paint over a coat of red oxide primer the rate for above items shall be deemed to be inclusive in the quoted rate.
Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 90 watt complete all as specified and directed. Make:Halonix/Philips/CG/Bajaj
Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 70 watt complete all as specified and directed. Make:Halonix/Philips/CG/Bajaj
Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed.
Supply, installation, commissioning and testing of floor mounted, free standing OEM made type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of CPRI approved IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliant & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 300 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole ,415 V of capacity 200 Amp, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 04 Nos. (c) MCB SPN of 240 V of capacity 40 Amps 10 KA - 02 Nos. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (f) Space for spare feeder - 01 No. Note :- (i) The contractor shall submit CPRI approved IP65 certificate and all type test reports of polycarbonate modular enclosure as per norms mentioned above in BOQ alongwith the make approval. (ii) The Contractor shall submit the drawing for approval of GE before executing the work. (iii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply and fix 4 Pole MCCB, 415 volts, fixed type, 400 Amp, 50 Hz, with rupturing capacity 36 KA with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder pillar box including connecting lugs with busbar and mounting arrengments i.e screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed. Make : Indo Asian/L&T/Havells
Supply and fix metal enclosure made suitable for 4 pole MCCB 415 Volts 400Amp capacity complete all as speficied and directed
Supply and fix in repair LED 40 watt Post top energy saving environmental friendly ,design with symetrical light distribution, clear landscape luminair(CDL) made in cast aluminium spigot housing and IP 65 Protection all as directed Make - Philips /Bajaj/Havells/CG
Supply only of GI pipe light grade for cable protection of size 100 mm bore with fittings, complete all as specified and directed.
Material and labour for Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.
Material and labour in repair for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for 3 ½ core 120 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for LT UG cable of size 3.50 core 150 Sqmm to 185 Sqmm, complete all as specified and directed.
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 150 Sqmm to 185 Sqmm 3.5 core of underground LT armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
S & F aluminum lugs suitable for aluminum cable of size 10 to 35 Sqmm complete all as specified and directed
S & F aluminum lugs suitable for aluminum cable of size 50 to 95 Sqmm complete all as specified and directed
S & F aluminum lugs suitable for aluminum cable of size 120 to 150 Sqmm complete all as specified and directed
Supply, installation, commissioning and testing of floor mounted, free standing OEM made type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of CPRI approved IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compilaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure shall be above 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board of any size and description, reconnecting existing LT UG Cable with new panel board, complete all as specified and as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amp, 36 KA - 02 Nos (Incomer). (b) On Load Change over front operated of capacity 250 Amp, 4 Pole, 415 V - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 16 KA - 01 No (O/G). (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (f) Space for spare feeder - 01 No. Note :- (i) The contractor shall submit CPRI approved IP65 certificate and all type test reports of polycarbonate modular enclosure as per norms mentioned above in BOQ alongwith the make approval. (ii) The Contractor shall submit the drawing for approval of GE before executing the work. (iii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply, installation, commissioning and testing of floor mounted, free standing OEM made type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of CPRI approved IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thromoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one no of 16 A 3 Pole IP65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 A current carrying capacity of Alluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and remove from site reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amps, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amps, 25 KA - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps,25 KA - 02 Nos. (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amps,10 KA - 01 No. (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (g) Space for spare feeder - 01 No. Note :- (i) The contractor shall submit CPRI approved IP65 certificate and all type test reports of polycarbonate modular enclosure as per norms mentioned above in BOQ alongwith the make approval. (ii) The Contractor shall submit the drawing for approval of GE before executing the work. (iii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
M&L in repair Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit, including taking down old u/s earth pit cover, complete all as specified and directed.
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip of any description, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.
Supply, installation, commissioning and testing of floor mounted, free standing OEM made type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of CPRI approved IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS complaints & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thromoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one no of 16 A 3 Pole IP65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 A current carrying capacity of Alluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 CM above ground level, including dismanting and taking out U/s LT panel board and remove from site reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amps 36 KA - 01 No (Incomer). (b) On Load Change over front operated of capacity 200 Amp, 4 Pole, 415 V - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps 25 KA - 02 Nos. (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amps 10 KA - 02 Nos. (e) MCB SPN of 240 V of capacity 40 Amps 10 KA - 04 Nos. (f) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (g) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (h) Space for spare feeder - 01 No. Note :- (i) The contractor shall submit CPRI approved IP65 certificate and all type test reports of polycarbonate modular enclosure as per norms mentioned above in BOQ alongwith the make approval. (ii) The Contractor shall submit the drawing for approval of GE before executing the work. (iii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Material and labour in repair for 3 ½ core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole etc, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 240 Sqmm to 300 Sqmm 3.5 core of underground LT armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
Surface dressing in hard / dense soil not exceeding 15 cm deep and clearing all the grass weeds etc in the sub station yards after removing stone aggregate aside all as directed at site including setting / spreading back the aggregate complete all as specified and directed at site.
Supplying and laying reinforced precast concrete cable cover, class HV, type 1 with flat, size 300mm x 180mmx 40mm, all as specified and as directed.
Supply, lay, test and commissioning of XLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured, heavy duty electric power cable (HT UG), 11000 volts grade with stranded aluminium conductor of size 3 core 120 Sqmm (Earthed) including taking out existing old unserviceable cable complete all as specified and as directed. Make: Havells/Polycab/RPG Asian Note - Earthwork and bricks to be measured and paid separately under respective items.
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120- 185 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. Make : Densons/ M-Seal/ 3M
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for out door straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120-185 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. Make : Densons/ M-Seal/ 3M
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120-185 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. Make : Densons/ M-Seal/ 3M
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. including excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm 3 core complete all as specified and as directed. Notes : (i) The contractor shall bring the fault locating equipment at site with in 02 hours of instructions received from Engineer -in- charge and he shall ensure that the fault is rectified with in 8 hours of receipt of intimation through telephone from Engineer-in-charge failing which recovery of Rs. 10000.00 per hour shall be recovered from the contractors dues w.e.f the time immediately after the expiry of 24 hours duration. (ii) For the purpose of payment one unit of “Each job” shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch, irrespective of number of defects / faults in that particular stretch which are detected during fault detection and the contractors unit rate quoted shall be deemed to include for the same and all such defects / faults which are detected in that particular stretch shall be considered as one unit. (iii.) Joints, jointing materials and cable required shall be measured and paid for separately
Supply, installation, commissioning and testing of floor mounted, free standing OEM made type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of CPRI approved IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliant & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No. of 32A 5P IP 65 industrial socket. 3 Phase and neutral 250 Amp current carrying capacity of Aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 160 Amps 25 KA - 01 No. (Incomer). (b) Change over switch 160A, 4P front operated - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amps 25 KA - 01 No. (O/G). (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps 10 KA - 01 No. (O/G). (e) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amps 10 KA - 01 No. (O/G). (f) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (g) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (h) Space for spare feeder - 01 No. Note :- (i) The contractor shall submit CPRI approved IP65 certificate and all type test reports of polycarbonate modular enclosure as per norms mentioned above in BOQ alongwith the make approval. (ii) The Contractor shall submit the drawing for approval of GE before executing the work. (iii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Attending, Repairing/restoring of electric power supply in the AFTC, CQAE and Jalahalli area, after identifying fault in HT 11 KV or LT 415 volt system, RMU,VCB, LT Panels, two/ four pole structure, transformers, Over head lines in any section or circuit, including checking of insulators, lightning arresters, GODs, LT Panel Boards and all electrical accessories and making it serviceable in all respect including replacement of nut, bolt, washers and minor parts/spares, insulation tapes and cable sockets of any size, complete all as specified and directed.
Note :- (i) The above work also include checking, detection and rectifcation of LT/HT UG Cable faults at AF Area as and when directed by Engineer-in-Charge/ JE (E/M).
(ii) Hiring of cable fault detector to detect exact location of HT UG cable fault deemed to be inclusive of unit quoted rate.
(iii) Major items required to be replaced/repaired shall be measured under relevant items of schedule/ BOQ.
(iv) Excavation and earth work if required shall be measured separately.
(v) compliants will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x7 Days).
(vi) In case of minor defect, entire job shall be completed within 02 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 300 /- per hours shall be recovered from the contractor.
(vii) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost shall be paid for the same.
(viii) In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspection by Engineer-in-Charge and authorised service agent of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs.500/- per hours shall be deducted from the dues of the contractor.
(ix) Note that penalty is exclusively other than the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer in this regard shall be final and binding.
Supply, installation, commissioning and testing of floor mounted, free standing OEM made type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of CPRI approved IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 800 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate for bedding upto a height of 45 CM above ground level, complete all as speified and directed and comprising of the following:-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amps, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amps, 25 KA - 01 Nos. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps,10 KA - 02 Nos. (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amps,10 KA - 01 No. (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (g) Space for spare feeder - 01 No. Note :- (i) The contractor shall submit CPRI approved IP65 certificate and all type test reports of polycarbonate modular enclosure as per norms mentioned above in BOQ alongwith the make approval. (ii) The Contractor shall submit the drawing for approval of GE before executing the work. (iii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Note :- An amount of Rs 2,26,147.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
8303PS.pdf
Additional Documents • 0.90 MB
8303GENPAGE.pdf
Tender Documents • 0.54 MB
BOQ_848078.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid