| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAdmitted-Finance 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L1 | Admitted-Finance | |
| 2 | L2₹31.4 L+₹7.1 L (29.4%)Admitted-Finance 88 197 B CHAMAN GANJ KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L2 | Admitted-Finance | |
| 3 | L3₹32.2 L+₹7.9 L (32.5%)Admitted-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Admitted-Finance | |
| 4 | L4₹36.9 L+₹12.7 L (52.2%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹37.5 L+₹13.2 L (54.4%)Admitted-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ASIA BUILDER L2 | DAVINDER SINGH L5 | PAWAN KUMAR GOVT. CONTRACTORS L4 | ANIKET TRADERS L3 | M/S M P Construction Co L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for quarterly periodical maintenance of fire alarm system complying with adderssable/Conventional type by attending fault on urgent basis, testing of system, periodical checking of system etc. including replacement of unserviceable components with preventive measures by replacing spares of fire alarm system installed at the various locations complete all as specified and directed.
Note- The Spare parts shall be measured and paid separately under respective items of this schedule. | 24 | Each JOB | 12,000 ₹2,88,000 | 1,000 ₹24,000 Lowest | 1,500 ₹36,000 | 2,000 ₹48,000 | 2,500 ₹60,000 |
| 2.00 | Supply only Remote response indicators Addressable /conventional type including unservisble spare parts and all specified and directed Engr-in-Charge. | 5 | Each | 10,000 ₹50,000 | 100 ₹500 | 1,800 ₹9,000 | 3,400 ₹17,000 | 70 ₹350 Lowest |
| 3.00 | Supply only Smoke Detectors Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed.
Make : Honeywell / AGNI/ Simplex / Kidde. | 35 | Each | 21,000 ₹7,35,000 | 1,250 ₹43,750 Lowest | 2,500 ₹87,500 | 2,300 ₹80,500 | 3,000 ₹1,05,000 |
| 4.00 | Supply and replacement of Mother board (Addrassable type) Complying with and type certified to NFS-2640 Notifier/Honyweloptical with base with self built intelligence as per IS: 11360 for panel 1 loop complete all as specifeid and as directed. | 1 | Each | 7,000 ₹7,000 Lowest | 7,500 ₹7,500 | 8,500 ₹8,500 | 10,000 ₹10,000 | 15,800 ₹15,800 |
| 5.00 | Supply and replacement of Mother board (Addrassable type) Complying with and type certified to NFS-2640 Notifier/Honyweloptical with base with self built intelligence as per IS: 11360 for panel 2 loop complete all as specifeid and as directed. | 1 | Each | 7,000 ₹7,000 Lowest | 14,000 ₹14,000 | 8,500 ₹8,500 | 10,000 ₹10,000 | 20,000 ₹20,000 |
| 6.00 | Supply and fixing in repair/replacement of response Indicator complete all as specified and directed including taking out old unserviceable necessary connections complete all as specified and directed. MAKE- Ceasefire-Hochiki, Notifire, Honeywell, Apollo. | 2 | Each | 400 ₹800 | 200 ₹400 | 500 ₹1,000 | 2,000 ₹4,000 | 100 ₹200 Lowest |
| 7.00 | Supply and fixing in repair/replacement of addressable control module complete mounting wall/roof/ceilling including taking out old unserviceable necessary connections complete all as specified and directed. MAKE- Ceasefire-Hochiki, Notifire, Honeywell, Apollo. | 2 | Each | 1,000 ₹2,000 | 2,500 ₹5,000 | 1,700 ₹3,400 | 2,000 ₹4,000 | 400 ₹800 Lowest |
| 8.00 | Supply and fixing in repair/replacement of addressable fault detector complete mounting wall/roof/ceilling including taking out old unserviceable necessary connections complete all as specified and directed. MAKE- Ceasefire-Hochiki, Notifire, Honeywell, Apollo. | 2 | Each | 8,000 ₹16,000 | 2,500 ₹5,000 | 2,500 ₹5,000 | 2,000 ₹4,000 | 200 ₹400 Lowest |
| 9.00 | M&L Short circuit isolator (loop isolator base) complete with mounting accessories. MAKE- Ceasefire/ Honeywell/ Simplex. | 4 | Each | 6,000 ₹24,000 | 1,200 ₹4,800 | 2,200 ₹8,800 | 3,000 ₹12,000 | 200 ₹800 Lowest |
| 10.00 | Supply and replacement of Mother board (Conventional type) Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed. | 4 | Each | 7,000 ₹28,000 | 5,000 ₹20,000 | 4,800 ₹19,200 | 2,000 ₹8,000 Lowest | 2,000 ₹8,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
21 Jan 2026, 6:00 pmClosed
GE AF UDHAMPUR
GE (AF) STN UDHAMPUR
RREPAIR AND MAINTENANCE OF FIRE ALARM SYSTEM, SMOKE DETECTORS, FLAME PROOF LIGHTS, AVAITION LIGHT, HANGER LIGHT AND FITTING /FIXTURES ALONG WITH CERTAIN MISC WORK AT VARIOUS LOCATION OF 39 WING AF STN UDHAMPUR
2025_MES_745917_1
GEAFU-71/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE (AF) STATION UDHAMPUR
RREPAIR AND MAINTENANCE OF FIRE ALARM SYSTEM, SMOKE DETECTORS, FLAME PROOF LIGHTS, AVAITION LIGHT, HANGER LIGHT AND FITTING /FIXTURES ALONG WITH CERTAIN MISC WORK AT VARIOUS LOCATION OF 39 WING AF STN UDHAMPUR
8 documents required · 8 mandatory
₹500
GE (AF) UDHAMPUR
₹80,000
24 Jan 2026
24 Dec 2025
23 Jan 2026
24 Dec 2025
21 Jan 2026
7 Jan 2026
24 Dec 2025 - 31 Dec 2025
M & L for quarterly periodical maintenance of fire alarm system complying with adderssable/Conventional type by attending fault on urgent basis, testing of system, periodical checking of system etc. including replacement of unserviceable components with preventive measures by replacing spares of fire alarm system installed at the various locations complete all as specified and directed. Note- The Spare parts shall be measured and paid separately under respective items of this schedule.
Maintanence and repair Remote response indicators Addressable /conventional type including unservisble spare parts and all specified and directed Engr-in-Charge.
Supply and replacement of Smoke Detectors Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed.
Supply and replacement of Mother board (Addrassable type) Complying with and type certified to NFS-2640 Notifier/Honyweloptical with base with self built intelligence as per IS: 11360 for panel 1 loop complete all as specifeid and as directed.
Supply and replacement of Mother board (Addrassable type) Complying with and type certified to NFS-2640 Notifier/Honyweloptical with base with self built intelligence as per IS: 11360 for panel 2 loop complete all as specifeid and as directed.
Supply and fixing in repair/replacement of response Indicator complete all as specified and directed including taking out old unserviceable necessary connections complete all as specified and directed. MAKE- Ceasefire-Hochiki, Notifire, Honeywell, Apollo.
Supply and fixing in repair/replacement of addressable control module complete mounting wall/roof/ceilling including taking out old unserviceable necessary connections complete all as specified and directed. MAKE- Ceasefire-Hochiki, Notifire, Honeywell, Apollo.
Supply and fixing in repair/replacement of addressable fault detector complete mounting wall/roof/ceilling including taking out old unserviceable necessary connections complete all as specified and directed. MAKE- Ceasefire-Hochiki, Notifire, Honeywell, Apollo.
M&L Short circuit isolator (loop isolator base) complete with mounting accessories. MAKE- Ceasefire-Hochiki, Notifire, Honeywell.
Supply and replacement of Mother board (Conventional type) Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed.
Supply and replacement of Hooter Conventional/addressable type Complying with and type certified to EN - 45 smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specifeid and as directed.
Supply and replacement of manual call point Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 including taking down complete all as specifeid and as directed.
Supply, laying & testing PVC insulated, PVC sheathed FRLS electric control cables (Heavy duty) with stranded copper fire serval cable conductor of size 1.5 sq mm ,2 core, 1100 Volts grade including taking down complete all specified and directed Engr-in-Charge. (Make: KEI/ Finolex/ RR cables/ Polycab/Havells)
M&L in repair Explosion proof point wiring for for one light/bell/buzzer with 1.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 1.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, all as specified.
M&L in repair Explosion proof point wiring for for one light/bell/buzzer with 1.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in rigid existing steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 1.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, all as specified.
M&L in repair Explosion proof point wiring for for one light/bell/buzzer with 2.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 2.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, complete all as specified.
M&L in repair Explosion proof point wiring for for one light/bell/buzzer with 2.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in rigid existing steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 2.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, complete all as specified.
M&L in repair Explosion proof point wiring for for one power point with 4.0 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 4.0 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, including taking down complete all as specified.
M&L in repair Explosion proof point wiring for for one power with 4.0 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in rigid existing steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 4.0 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, including taking down complete all as specified.
Supply and fix in repair of Explosion proof rotary switch single pole on and off with cable termination box of 10 Amps rating 230 Volts Class E EX II C suitable for class I Zone I, all as specified. Make :- Sudhir/Shyam
Supply and fix in repair of Explosion proof rotary switch single pole on and off with cable termination box of 16 Amps rating 250 Volts Class E EX II C suitable for class I Zone I, all as specified. Make :- Sudhir/Shyam
Supply and fix in repair of Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25 Amps, 250 Volts, 2P+earth all as specified. Make :- CAT No SSPL/2C/1010 of shyam or equivalent in Sudhir
Supply and fix in repair of LED 150 W Flameproof intergral wellglass luminaire epoxy finish LM6 aluminium alloy housing with heat resistant and toughened glass cover painted MS wire guard and eye bolt incuding all accessories pre wired with polycarbonate cover polyester resin encloser and central locking system, complete all as specified including taking down old.
Supply and fix in repair of LED 250 W Flameproof non-intergral wellglass luminaire epoxy finish LM6 aluminium alloy housing with heat resistant and toughened glass cover painted MS wire guard and eye bolt incuding all accessories pre wired with polycarbonate cover polyester resin encloser and central locking system, complete all as specified
Supply and fix in repair Flame proof Flood light fitting 250 watt LED, metal handle lamp, IP65 degree of rotation with reflector wire guard FL/1251, complete all as specified and direcetd.
Supply and fix in repair Flame proof Flood light fitting 150 watt LED, metal handle lamp, IP65 degree of rotation with reflector wire guard FL/1251, complete all as specified and direcetd.
Supply and fix in repair Flame proof Flood light fitting up to 65 watt LED, metal handle lamp, IP65 degree of rotation with reflector wire guard FL/A/150, complete all as specified and direcetd.
Supply and fix in repair LED light fitting 1x16/20 Watt 4 Feet flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and fix in repair LED light fitting 2x20/16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and fix in repair Flame proof LED tube light fitting 2x40 watt 4 Feet Fitting LM-6 Construction with tube rod certified by CMRI including taking down Complete all as specifeid and directed
M&L Taking down existing Flame Proof Weather Proof Tube Light Fitting 1x20/40 Watt rod of any type and Make including Taking out Electronic Ballast, Starter, Tube Rod 20/40 Watt and Providing New LED rod 1x20/ 40 Watt Complete with Glass of Make Borosil including Making Electric Connection with Connector, complete all as specified and as directed.
M&L Taking down existing Flame Proof Weather Proof Tube Light Fitting 2x40 Watt rod of any type and Make including Taking out Electronic Ballast, Starter, Tube Rod 20/40 Watt and Providing New LED Light rod 2x40 Watt Complete with Glass of Make Borosil including Making Electric Connection with Connector, complete all as specified and as directed.
Flameproof control gear box epoxy finish LM6 aluminium alloy housing including all accessories prewired with polycarbonate cover polyster resin encloser and central locking system, all as specified including taking down old completre all as specifeid and as directed
Taking out burnt/damaged copper winding wire from 1200/1400mm Sweep Flame proof ceiling fan motor of any make and M&L for rewinding of ceiling fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating material, soldering, varnishing capacitor, ball bearing, bush,locking pin and certain minor repair etc assembling and testing and refixing of same places complete all as specified.
Taking out burnt/damaged copper winding wire from 400/600mm Sweep Flame proof Exhaust fan motor of any make and M&L for rewinding of ceiling fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating material, soldering, varnishing capacitor, ball bearing, bush,locking pin and certain minor repair etc assembling and testing and refixing of same places complete all as specified.
Taking down old DB and supply and fixing Flame proof with explosion protection MCB distribution board encloser single pole & neutral 240 volts 12 way complete with enclouser size 300x300x190 mm and appropriate size bus bar and neutral link suitable for class 1 Zone 1 & Ex IIC suitable for & including following accessories : (i) MCB SPN 32 Amps with rupturing capacity 16 KA - 01 Nos (ii) MCB SP 06 Amps with rupturing capacity 10KA - 10 Nos Make :- Sudhir or equivalent in shyam
Taking down old DB and supply and fixing Flame proof with explosion protection MCB distribution board encloser single pole & neutral 240 volts 12 way complete with appropriate size bus bar and neutral link suitable for class 1 Zone 1 & Ex IIC suitable for & including following accessories : (i) MCB TPN 63 Amps with rupturing capacity 16 KA - 02 Nos (Incoming ) (ii) MCB SP 32 Amps with rupturing capacity 10KA - 02 Nos (ii) MCB SP 6 Amps with rupturing capacity 10KA - 01 Nos (iv) MCB SP 16 Amps with rupturing capacity 10KA - 01 Nos Make :- Sudhir or equivalent in shyam
Supply and replacement of Flame proof Socket & plug combined 500V 32 AMPS 4P+Earth complete all as specifeid and as directed
Supply and replacement of Flame proof Socket & plug combined 500V 63 AMPS 4P+Earth complete all as specifeid and as directed
Supply and fixing of Flame proof FH/199 FLP/WP flexible Metalic Conduit in SS304-300MM Length with3/4" ET(M)X3/4" ET complete all as specifeied and asd directed.
Supply and fixing of Flame proof JB/OA/104 FLP 4 Way Junction box(to be used as incpection Elbow) complete all as specified and as directed.
Supply and fixing of Flame proof CG/209- FLP/WP3/4" ET 17.50mm OD DC bras Nickel plated Cable Gland complete all as specified and as directed.
Supply and fixing of Flame proof Bn/C/165FLP/WP Bends 90 degree or 45 degree for conduit with3/4" ET entries complete all as specified and as directed.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of heavey duty steel conduit drawn through steel conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of rigied existing steel conduit drawn through steel conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire together alongwith steel conduit shall be considered as 1 running metre for payment purpose.
All as per Sl item No 44 but of size 6.00 sqmm but heavey duty 20/25mm rigid existing conduit steel pipe (nominal area) and of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire. Note: Two runs each of 6.00 sqmm main cable and one RM of 6.00 sqmm cable as earth wire together shall be considered as 1 running metre for payment purpose.
All as per Sl item No 44 but of size 10.00 sqmm but heavey duty 20/25mm conduit steel pipe (nominal area) and of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire. Note: Two runs each of 10.00 sqmm main cable and one RM of 10.00 sqmm cable as earth wire together shall be considered as 1 running metre for payment purpose.
Sheet metal enclosures for DBs SPN 12 way (when MCBs to be used) flush mounted including accessories therein and disposing off complete all as specified and directed. Make:Legrand/HAVELLS / Schneider
Sheet metal enclosures for DBs SPN 8way (when MCBs to be used) flush mounted including accessories therein and disposing off complete all as specified and directed. Make:Legrand/HAVELLS / Schneider
MCB SPN 40 to 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including accessories therein & disposing from site complete all as specified and as directed.
MCB SPN 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including accessories therein & disposing from site complete all as specified and as directed.
Supply and fix in repairs of MCCB 4P 100 Amps /415Volts ,having breaking capacity with Complete accessories as per existing suitable size complete all as specified and as directed
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 6 Sqmm 4 core laid on walls/floors or in air with saddles and gutties complete all as specified and directed.Make :- Gloster / Havells / CCI.
Supply laying, connecting and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of size 25 sqmm 4.0 core laind in trenches or passing through pips/ ducts complete all as specified and directed by Engineer in charge
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 16 Sqmm 4 core laid on walls/floors or in air with saddles and gutties including PVC conduitcomplete all as specified and directed.Make :- Gloster / Havells / CCI.
S&F in recess on wall ERW Conduit of size 20/25mm, ISI marked, heavy duty with all Conduit Accessories and Making Good Surfaces to match the Exiting Treat-ment (as per Site requirement) including Taking down/out Old Unserviceable Conduit, complete all as per specified and as directed.
Supply and repair of MS Nipple BSP 175 MM/3/4" as per existing fitting /DBs complete all as specified and as directed.
Supply and repair alluminium alloy/ cast iron Neoprene Gasket degree of protetion IP65 and fixing-in -repairs complete all as specified and as directed .
Supply and repair of MS Nipple conduit 175 MM/3/4" as per existing firring /DBs complete all as specified and as directed.
Supply and fixing of Electronic Hooter three phase Dynamically Balanced Siren including electric connection range of Hooter 1.5 KM Both side complete all as specified and specified and as directed.
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and LT cable and getting out, , complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed by Engineer-in-Charge
Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed by Engineer-in-Charge
Dry sand cushioning to under ground cable all as per clause 19.75 of SSR Part - I laid before and after laying of cable, complete all as specified and directed by engr-in-charge.
Sub class 'B' old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable complete all as specified and directed
Cutting of road (in hard/ dense soil ) for laying pipe line or repair to pipes of any size upto 0.5mtr. Depth and getting out incluiding forming bottom surface to required level and making good the road as per existing bitumens , concrete all as specified and directed.
S&F 80 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed.
S&F in repair of Addressable fire alarm panel as per existing size the following technical specifications Honewell / Morly ZX DX Series including programing and connected accessories complete all as specifeied and directed by Enginer in charge . (a) Oprating voltage : Between 15-30 volts DC peak (b) Max Stand by current : less than 1mA (c) Alarm LED current : max 1 mA (d) Operating Temp :- 100 C to +550 C (e) humidity : 0 to 95% RH (f) Wiring : 2 core (g) Protective transparent flip cover to prevent accidental activation (h) Electonic Addressing (j) Blinking LED for visual supervision (k) No frangible glass (l) Stable Communication with noise immunity (m) Automatic device Mapping. (n) Alarm flag for fast alarm reporting.
S&F in repair of conventional fire alarm panel the following technical specifications and all specified and directed Engr-in-Charge. (a) Oprating voltage : Between 15-30 volts DC peak (b) Max Stand by current : less than 1mA (c) Alarm LED current : max 1 mA (d) Operating Temp :- 100 C to +550 C (e) humidity : 0 to 95% RH (f) Wiring : 2 core (g) Protective transparent flip cover to prevent accidental activation (h) Electonic Addressing (j) Blinking LED for visual supervision (k) No frangible glass (l) Stable Communication with noise immunity (m) Automatic device Mapping. (n) Alarm flag for fast alarm reporting.
Supply and fix in repair of Integral 100W LED aviation obstruction light luminaire WG/1238 in yellow die-cast aluminium alloy housing with red coloured polycarbonate dome of including necessary electric connection with suitable size of PVC copper 2.5 sqmm with earth wire cable and suitable size GI bricket as per manufacture's requirement and blast pen building complete all as specified and as directed by Engineer-in-Charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_835225.xls
BOQ • 8.37 MB
TENDER71.pdf
Tender Documents • 1.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .