| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC 107 1F TOLLYGUNGE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹19.5 L+₹60,040 (3.18%)Rejected-AOC 107 1A TOLLYGAUNG ROAD KOLKATA 700026 WB | KOLKATA | WEST BENGAL | 700026 | L2 | Rejected-AOC OTHER THAN L1 | |
| 3 | L3₹20.5 L+₹1.6 L (8.25%)Rejected-AOC G C ROAD ABDUL LATIF ROAD PO TITAGARH P S RAHARA KOLKATA 700 119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L3 | Rejected-AOC OTHER THAN L1 | |
| 4 | L4₹21.0 L+₹2.1 L (11.1%)Rejected-AOC 197 PATHAK PARA ROAD KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | L4 | Rejected-AOC OTHER THAN L1 | |
| 5 | L5₹21.8 L+₹2.9 L (15.3%)Rejected-AOC BHANGARMATH THAKURANICHAWK PO SAMABAYPALLY BALLY HOWRAH 711205 | HOWRAH | HOWRAH | WEST BENGAL | 711205 | L5 | Rejected-AOC OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹38,600
Closing Date
2 Oct 2024, 6:00 pmClosed
GE (I) (CGN) Kolkata
GE (I) (Coast Guard Navy) Military Engineer Services Damodar Complex Naval Transit Accommodation Hastings, Kolkata 700 023
REPAIR AND MAINTENANCE OF EXTERNAL WATER SUPPLY SYSTEM, SWIMMING POOL, FIRE FIGHTING/ FIRE ALARM AND RO AND EXTERNAL ELECTRIC SUPPLY SYSTEM AND EOT CRANE INCLUDING CERTAIN MISC WOK AT DHQ-08, JETTY, AZADHIND NAGAR, VIKRAM ENCLAVE AT HALDIA
2024_MES_672466_1
8701/22/2024-2025/04/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HALDIA
Class E and above and b(ii) or a(ii) category
8 documents required · 8 mandatory
₹500
GE (I) (CGN) Kolkata
₹38,600
Yes
25 Oct 2024
6 Sept 2024
3 Oct 2024
6 Sept 2024
2 Oct 2024
19 Sept 2024
Amount
Supply and laying in replacement in trenches or fixing or passing through pipes or fixed to wall/pole 11000 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 50 Sqmm 3 core complete all as specified and as directed.
Supply and laying in replacement in trenches or fixing or passing through pipes or fixed to wall/pole 11000 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 120 Sqmm 3 core complete all as specified and as directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as spcified and as directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm all as spcified and as directed.
M&L for finding out the fault to under ground HT cable by cable fault locator machine or manually excavation all as required and directed by Engr-in-Charge.
Supply only HT fuse wire of 15 Amps or capacity as per existing site requirement complete all as specified and directed.
Repair/maintannces and caliberation of VCB of any make any capacity by disconnecting electric supply , checking /cleaning the bus bar, testing of relay , silica gel etc and changing of damaged insulators, slip , nuts & bolts, heating the spare parts, reassembling and testing & commissioning complete all as specified and as directed. (Note : (i) Maintenance /repairs of VCB shall be carried out by trained technicians/mechanic under super vison of qualified electrical technician. (ii) All repairs shall be carried out at site only. Necessary testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate.
S & F 11 KV panel indicating lamp fitting LED type suitable for 24 volt/30volt DC complete with base complete all as specified
S & F 11 KV panel indicating lamp fitting LED type suitable for 110 volt/230volt AC complete with base complete all as specified
Supply & filling only Transformer Oil for topping up the level( after necessry disconnection and earthing both winding) with grade as per IS : 335 complete incl opening the tank cover and refixing the same and charging the transformer to the supply voltage complete all as specified and as directed. (Note : BDV of the oil shall be ensured not less than 60 KV before filling).
M & L for filteration of transformer oil by disconnecting the device from supply and draining out the complete oil, filtering the dirt, sludge and dehumidifying by heating the same and raising the Breakdown voltage level 50 KV at 2.5 mm gap and testing and recording the result for three times in specified interval including pouring the oil in transformer tank and charging the same to restore supply complete all as specified and as directed.
M & L for servicing of DG set 100 KVA DG Set Make: Greaves Cotton Ltd Model No : GPWII-PII-100 at Vikram Enclave for every six months or 250 Hrs running which is earlier. Checking of all the lubricant oil, fuel oil, water hose pipes connection, checking pipe line leakage, checking solenoid switch, coolant temperature, oil pressure, No load RPM, RPM @ load, voltage in lines, current in lines, battery parameters, DG sets vibration,exhaust system, radiator fins for any leakage, cleaning of air filters and also check the on load @ 25%, 50%,75%,100% and 110%. Inclusive of replacing all the Engine oil, fuel filters, engine oil filters, air filter, solenoid valve/swich, hoses complete all as specified and directed. Note : Replacement of engine oil, lubricants filters, coolant,Air and oil filters, primary and secondary elements, hoses, solenoid switch are included in quoed rate.
All as per above item No 12 but 62.5 KVA DG Set Make: Greaves Cotton Ltd Model No : GPWII-PII-100 at Vikram Enclave
All as per above item No 12 but 25 KVA DG Set Make: Greaves Cotton Ltd Model No : GPWII-PII-25KVA at Azad Hind Nagar
All as per above item No 12 but 125 KVA DG Set Make: KOEL Green by Kirloskar Model No : KG1-125WS at Azad Hind Nagar
All as per above item No 12 but 500 KVA DG Set Make: Greaves Cotton Ltd Model No : GPWII-500 KVA at Jetty Area
All as per above item No 12 but 400 KVA DG Set Make: KOEL Green by Kirloskar at New Jetty Area
All as per above item No 12 but 100 KVA DG Set Make: Ashok leyland Model No : LP-100D at CGDHQ
Supply, fixing and testing of controller of 25 KVA DG Set Greaves Cotton Ltd Model No : GPWII-PII-25KVA complete all as per existing site.
Supply and fix Battery 100-150 AH battery for DG set of make Exide, TATA green, Amaraja etc or equivalent
Supply and laying in replacement in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 35 Sqmm 4.0 core complete all as specified and as directed.
Supply and laying in replacement in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 10 Sqmm 4.0 core complete all as specified and as directed.
Supply and laying in replacement in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 25 Sqmm 3.5 core complete all as specified and as directed.
Supply and laying in replacement in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 50 Sqmm 3.5 core complete all as specified and as directed.
Supply and laying in replacement in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 240 Sqmm 3.5 core complete all as specified and as directed.
Supply and laying in replacement trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 300/400 Sqmm 3.5 core complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 35 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 50 to 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 to 240 sqmm complete all as specified and directed.
Excavation in trenches, n. exc. 1.5m wide and n. exc. 1.5m in depth; for laying of cable, n. exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point
M&L fine sand, filling in trench for cable cushioning and gently punned down by manually with hands complete all as specified and directed. cable cushoining complete
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with flat, size 250mm x 150mm x 40mm complete specified and directed.
Supply and laying tubes 100 mm dia steel water tube light grade galvanised with all fittings laid in trenches complete all as specified and as directed.
Supply and laying tubes 50 mm dia steel water tube light grade galvanised with all fittings laid in trenches complete all as specified and as directed.
Decarburizing/ cleaning complete LT 415 volts 3 phase panel/ bus bar chamber with electrical connections complete bus bar from the bus bar chamber, cleaning with CTc, connection of all control cables and ensure proper decarburizing, refixing the same after applying Backtol red solution to the bus bar insulator & checking all the connections, tightening the nuts, bolts & thimbles of in-coming/ out-going system complete incl replacement of defective rusted bolts & nuts and Removing existing old paint by scraping from LT Panels, material labour for two coats of RAL 7035/7032 paint (1st quality) by spraying complete all as specified and directed.
Supply and install in replacement of ON LOAD change over switch 415V 4 pole of capacity 100 Amps in open execution type fixing in existing panel if req then including necessary modification in the panel and incl dismantling old one. Make L&T/havells/GE
M&L in replacement for MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 KA.
M&L in replacement for MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 KA.
M&L preparation of old painted surface above the planting depth and PCC coping of steel tubular LT pole of upto 9.00 metre length including MS clamps ,cable protection pipe bracket fitted with street light fittings etc by scraping with steel wire brush and applying two coats, of aluminium paint to external surface of poles MS cross arms MS clamp, cable protection pipe etc to give even shade including Zebra colour of painting from 2.1 mtr height from the top of caping/ bottom of pole as per site condition and numbering of poles complete all as specified and as directed by Engr-in –charge. Note: Zebra colour will be applied by synthetic enamel paint of black/yellow colour as approved in alternate layer of 30 cm height of each layer.
S&F in replacement for three pole power contactor, 415 Volts, MNX-12, conform to relevant IS, Range from 12-30 Amp AC-3, I Robust and suitable for hostile applications for street light control including electric connection complete. Make L&T Cat No CS94108 or equivalent in Siemens / ABB.
S&F in replacement Digital street light timer Crono 240 VAC base/Din mounting Digital type suitable for street light control including taking down old one complete all as specified and as directed. ( Make : L& T or equivalent)
M&L for PVC cable end terminal boxes outdoor type for street light pole, 30x20x10cm, PVC door, sintex box provision for cable incoming and outgoing from bottom, comprising of one MCB SP 6-32 Amps, cable glands suitable and one porcelein connector four way complete fixed on wall/pole with necessary clamps, screw etc all as specified and directed by the Engr-in-Charge.
Supply and fixing in replacement of LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fixing in replacement of LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing in replacement of LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply and fixing in replacement of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics and incl street light bracket with suitable size GI pipe as per existing site complete with IP 65/66 protection complete.
M & L for 4.0 Sqmm 5 core EPR/PCP Pvc Insulated & Sheathed Copper Flexible Cable for high mast complete all as specified and directed.
M&L Sub main wiring with two runs of 2.5 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through PVC rigid conduit with all fittings and accessories of PVC rigid conduit complete fixed to wall / ceiling / pole etc incl one run of 2.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead 32x6 mm galvanised strip and GI pipe 50 mm medium grade for earthing lead protection to the extent of maximum 7.5 m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI bolts & nuts complete all as per Electrical plate No 3 of SSR Part-I, connected to panel/DB including testing on completion including main earthing, charcoal, common salt, PCC [1:2:4 Type B1] Pit with RCC 1:2:4, Type B1 cover, 50 mm thick with 6 Nos, 8 mm Dia TMT bars in both ways, MS frame made with 40X40X6 mm angle Iron, MS Funnel with 20 mm bore , medium grade GI watering pipe, wire mesh, earth excavation return filling, removal of surplus soil etc complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x6 mm galvanised iron strip complete all as specified and directed.
M & L for Wire Rope - 6 MM HIGH MAST ROPE SS 7/19 for high mast complete all as specified and directed.
S & F Voltmeter 0-500 Volts digital type incl taking down old one complete all as specified and as directed.
S & F Ammeter 0-100 digital type incl taking down old one complete all as specified and as directed.
S & F Voltmeter 0-500 Volts Analoge type incl taking down old one complete all as specified and as directed.
S & F Ammeter 0-100 Analoge type incl taking down old one complete all as specified and as directed.
S&F indicator LED phase lamps 03 Nos. (R,Y,B) incl taking down old one complete all as specified and directed.
Supply and fix 3 Pole ML 1.5 Power Contactor, SS91851 complete all as directed
Supply and fix 3 Pole ML 4 Power Contactor, SS90910 complete all as directed
M & L for Repair of existing Solar street light and replace the existing unserviceable battery and cleaned the solar panel and repalced the existing unsv wiring the panel to battery system and light fitting and if any minor wk cost to be inclusive in quoted rate complete all as specified and directed. Note : (i) Battery will be paid and measure seperately.
S & F Solar tubular battery of 100 Ah in existing Solar street light and taking down existing unsv battery complete all as specified and directed.
M&L for rewinding 01 HP of electric motor/ Submersible motor with super enamelled copper wire of existing gauge, varnishing drying with electric furnace process with taking down burnt winding, cleaning of stator and roter including replacement of bearing, mechanical seal etc. including lifting, lowering, fixing, unfixing, testing & commissioning complete all as specified and directed.
All as per above item No 64 but for the 3 HP capacity electric motor/ Submersible motor complete all as specified and directed.
All as per above item No 64 but for the 5 HP capacity electric motor/ Submersible motor complete all as specified and directed.
All as per above item No 64 but for the 7.5 HP capacity electric motor/ Submersible motor complete all as specified and directed.
All as per above item No 64 but for the 15 to 20 HP capacity electric motor/ Submersible motor complete all as specified and directed.
M&L for maintenance and servicing of 01 HP Centrifugal coupled Pump set/ Monoblock pumps set/ submersible pump set as said capacity after decoupling the pump and motor, auxiliary piping, checking of alingment of pumpset, replacing the flexible coupling, removing the entire housing such as bearing housing, st box housing, delivery casing etc and removeing the impeller from the shaft, gland nut, gland, separating shaft, replacement of bush, bearing, impeller etc completely included and all the parts should be thoroughly cleaned in Kerosene or Benzene to remove the dirt rust etc. After cleaning, all the parts should be thoroughly checked for wear, remount thereafter and applying bearing grease as per manufacturer recommendation, checking gland packing seal, and remounting the pumpset at the position with piping connections complete incl testing to its full capacity. Notes : (i) Checking for proper aligment and rectification. (ii) Checking for proper lubrication in bearing and lubricating. (iii) Checking all electrical panel using for pumping for cleanliness and rectification for any looseness burnt redressing etc However, labour element involved in replacement is included in unit rate quoted against this item. (iv) Necessary work for realignment such as relocation and replacement of foundation bolt shall be deemed included in the rate. (v) Shaft should be grind properly at lathe m/c otherwise change the existing shaft as existing condition , even if not mentioned in this item, shall be carried out by the Contractor without any extra cost to the department. (vi) Checking of leakage in gland packing, shifting base, bushes etc and rectification included in quoted price. (vii) Checking for any undue noise of motor pump and rectification included in quoted price. (viii) Mechanical seal & motor terminal are replaced if it is damaged incl in quoted rate.
All as per above item No 69 but for the 2 HP capacity Centrifugal coupled Pump set/ Monoblock pumps set/ submersible pump set complete all as specified and directed.
All as per above item No 69 but for the 3 HP capacity Centrifugal coupled Pump set/ Monoblock pumps set/ submersible pump set complete all as specified and directed.
All as per above item No 69 but for the 5 HP capacity Centrifugal coupled Pump set/ Monoblock pumps set/ submersible pump set complete all as specified and directed.
All as per above item No 69 but for the 7.5 HP capacity Centrifugal coupled Pump set/ Monoblock pumps set/ submersible pump set complete all as specified and directed.
All as per above item No 69 but for the 10 HP capacity Centrifugal coupled Pump set/ Monoblock pumps set/ submersible pump set complete all as specified and directed.
All as per above item No 69 but for the 15 HP capacity Centrifugal coupled Pump set/ Monoblock pumps set/ submersible pump set complete all as specified and directed.
All as per above item No 69 but for the 20 HP capacity Centrifugal coupled Pump set/ Monoblock pumps set/ submersible pump set complete all as specified and directed.
All as per above item No 69 but for the 120 HP capacity Centrifugal coupled Pump set/ Monoblock pumps set/ submersible pump set complete all as specified and directed.
Supply and fix DOL starter relay with contactor of 10-35 Amp as per existing site requirement complete all as specified and directed.
Supply Fixing and testing of electronic motor protection relay with contactor of 9-45 Amps for protection to single phase preventor , earth fault, overload, Phase Sequence Reversal and trip protection complete all as per existing site condition complete all as specified and directed.
S & F in replacement of DOL starter for motor pump set of 01 HP 3 phase as per existing at site and remove the unsv all as specified and directed by Engr-in-charge.
S & F in replacement of DOL starter push button (Red/ Green) upto 15 HP and remove the unsv all as specified and directed by Engr-in-charge.
S & F in replacement of rubber bush between metal coupling for 5/15 HP pumps complete all as specified and directed by Engr-in-charge
S & F in replacement of metal coupling of CI with tyre rubber connector for 5 to 15 HP pumps complete all as specified and directed by Engr-in-charge
M & L for fixing Gland Packing seal of 5 mm thick for horizontal multistage type motor driven end suction pump including necessary dismantling of stuffing box complete.
M&L preparation of surface incl scraping the old painted surface and applying a coat of synthetic enamel paint to all pump set and associted water pipe lines, filteration plants and marked the flow direction of water on pipe by yellow color complete by approved shade and painting the coupling and foundation channel by black bituminous paint complete all as specified and as directed.
Carrying out testing of water on monthly basis by collecting water sample from vikram enclave pump house, azadhind nagar pump house, jetty area pump house, DHQ pump house etc in presence of user rep and MES rep in bottle, sealed the same at the same time for testing for the following test by reputed NABL test laboratory, (a) Appearance, Tester & Odour, Ph value, Iron as Fe and Hardness as CaCO3 and Bacteriologicla examination (Coliform Bacelli and Excherichia coli). Note : Water Testing report submitted to Engr-in-Charge regularly. Note : Necessary arrangements for empty bottle, sealing to bottle, tpt from site to laboratory and back should be included in quoted rates.
Supply only dual test kit to visual check pH/Residual Chlorine available with separate test vial with colour comparator and user manual all as specified and as directed.
Supply only phenol red solution for PH test bottle(500 ml) and OT solution for chlorine test bottle(500 ml) complete all as specified and as directed.
M & L for Cleaning of 25K gallon capacity underground/ semi underground sump hrough 7 stage mechanical tank cleaning process by involving the following seven stages of cleaning process complete all as specified and as directed by Engr-in-charge. (a) first stage is Draining out reserved water by opening drain out valve/ dewatering system. (b) Second stage is Removing all scale, dirt, mud inside the tank by using TERBACK G10 chemical and scrubbing the wall of tank all complete. (c) Third stage Cleaning inside surface of the tank with fresh water by high speed jet pump all complete. (d) Fourth stage is First bacteria screening for sterilisation by using TERBACK G5 a laboratory certified branded halogen compound, test certificate of TERBAC-G5 from government laboratory mentioning suitability for sterilisation should be submitted to the office before using for sterilisation all complete. (e) Fifth stage is Cleaning the floor of the water tank by heavy duty industrial vacuum cleaner all complete. (f) Six stage is the second bacteria screening for sterlisation by using UV rays ejactor covering 360 degree with in the tank and kills all suspended bacteria all complete. (g) Seven stage of cleaning and third bacteria screening for sterlisation by using laboratory certified branded strong oxidizing agent TERBACK G65. Test certificate of terabac G65 for government laboratory mentioning suitability for sterilization should be submitted to the office before using for sterilisation. Note : (1) The entire work should be carried out be TANKCLEAN process bt any franchises or M/s RAYS CLEANTECH or any other MES approved firm having equivalent technology, Company will submit government laboratory test certificate of terabac-G5, terabac-G65. (2) Entire T& P should be arranged by the contractor at their own. Only electric power & water shall be supplied by MES at the stipulated rate. (3) "Date of cleaning" should be written over the outer surface of tank by syntheticenamel paint with lettering not less than 100 mm height. Cost of the same is deemed inclusive in the quoted unit rate of cleaning of tank. the tank should be cleaned as per above said method with in the same day. (4) All the cleaning & sterilisation staffs should be under accidental insurance coverage.
All as per above item No 89 but for the 35k gallon capacity underground/ semi underground sump set complete all as specified and directed.
All as per above item No 89 but for the 40k gallon capacity underground/ semi underground sump set complete all as specified and directed.
All as per above item No 89 but for the 50k gallon capacity underground/ semi underground sump set complete all as specified and directed.
All as per above item No 89 but for the 25k gallon capacity open sump set complete all as specified and directed.
All as per above item No 89 but for the 25k gallon capacity GRP Tank above the roof complete all as specified and directed.
Supply and fixing reverse osmosis micron cartiridge - 20" including taking down existing worn out ones complete all as specified and directed. Make : Gopani/Kemtek India/Multitex Engg or equivalent. Note : Each cartiridge use maximum 20 to 25 days for each installation or as per site requirement.
Supply and fix in replacement of existing fully automatic electric control panel for 1000 LPH RO plant, panel has included contactor relay for 1 HP-02 Nos pump and 3 HP -01 No booster pump, also Digital display for showing data i.e Amp, volt, PPM, PH etc complete all as per existing panel complete all as specified and directed.
Supply and fixing in replacement of 25 mm side and 40 mm top mount multiport valve as per existing at site complete all as specified and directed.
Supply, filling Softener Resin in existing RO Plant and remove the existing unsv resign complete all as pecified and directed.
Supply only UPVC Sch-40 Pipe of 25 mm dia with all necessary joints, sockets,elbow, reducer, joiner etc as per existing site included in quoted prices.
Supply only UPVC Sch-40 Pipe of 32 mm dia with all necessary joints, sockets, elbow, reducer, joiner etc as per existing site included in quoted prices.
Supply and fixing new RO membrane Hydramem 4040 BWE/ ULP for 1000 LPH and remove unsv complete all as specified and directed.
M&L for 80 mm dia Stop/gate valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
M&L for 50 mm dia Stop/gate valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
M&L for 40 mm dia Stop/gate valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
M&L for 25 mm dia Stop/gate valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
Supply and laying tubes steel water tube 25 mm nominal dia medium grade galvanised with all fittings laid in trenches/ floor/ wall and remove the unsv existing tube including painting as per site requirment complete all as specified and as directed.
Supply and laying tubes steel water tube 40 mm nominal dia medium grade galvanised with all fittings laid in trenches/ floor/ wall and remove the unsv existing tube including painting as per site requirment complete all as specified and as directed.
Supply and laying tubes steel water tube 50 mm nominal dia medium grade galvanised with all fittings laid in trenches/ floor/ wall and remove the unsv existing tube including painting as per site requirment complete all as specified and as directed.
Supply and laying tubes steel water tube 80 mm nominal dia medium grade galvanised with all fittings laid in trenches/ floor/ wall and remove the unsv existing tube including painting as per site requirment complete all as specified and as directed.
Supply and laying tubes steel water tube 100 mm nominal dia medium grade galvanised with all fittings laid in trenches/ floor/ wall and remove the unsv existing tube including painting as per site requirment complete all as specified and as directed.
M & L for Manual Call Box , ABS body suitable for conventional fire alarm system, with alarm test key facilities, wall mountable and optional LED blinking facility incl mounted to wall with suitable screws, plugs etc and taking down the unserviceable one complete all as specified and as directed.
M & L for Lead Acid battery (Composite battery) for Fire alarm panel 6/12 V, 4.5 to 12 AH incl taking down complete
M & L for Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short
Supply and fixing of RRL type B hose of 15 mtr long as per ISI 636 and remove existing unsv complete all as specified and directed.
Material and Labour for scrapping of old painted surface of fire hydrant/fire hose box,pipes, cabinet boxes and all items related to fire figthting system of any size on groung/wall cellings and painting with one coat of red oxide and two coats of synthetic enamelled paint of FIRE RED colour by spray/brush painting on cabinet boxes and any where possible complete with all fittings etc all as specified and directed by Engineer-in-charge.
M & L for Cutting existing steel tubing for alterations or additions & Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector done in position without taking down for 25/32/40/50/80/100 mm dia pipe
Supply and fixed First aid KIT with all accessories on wall as directed by Engineer-in-Charge including necessary medicines complete all as directed
Supply only curved brushes made in polypropylene for pool basins and scum liners clip type all as manufacture instruction with expandable handle pipe upto 3 mtr long for easily to cleaning complete all as specified and directed. Make : Astrol pool india ltd/ proteam/ UV-Rich/ ION Exchange/ Austin.
Supply only straight brushes with stainless steel bristles all as manufacture instruction with expandable handle pipe upto 3 mtr long for easily to cleaning complete all as specified and directed. Make : Astrol pool india ltd/ proteam/ UV-Rich/ ION Exchange.
Supply and fix 5A A1D1-X ON Delay Timer, 24 To 240v Ac & 24 To 220v Dc complete all as directed
Supply and fix 50mm medium Grade GI tube of approx length 3.0 mtr as the extension of Dg set exhaust including bends/tee, flanges and insulation rope winding on the gi pipe as per site requirment complete all as specified and directed.
Material and labour for Iron/Ductile iron sheet of minimum 2.5 mm thick for cover of UG tank/Valve pit Chamber/Drain Duct of RO with necessary handles as per site requirment/size including all necessary welding fabrication as per directed by Enginee-in-Charge Complete all as specified and directed.
Supply and fix 3 Pole 25A Power Contactor 3RT2026-1AL20 complete all as specified and directed
M&L for 80 mm Foot valve cast iron body/door flange type as per site complete all as specified and directed
supply and fix Sluice Valve Class PN 1.6, 80 mm complete all as specified and directed
supply and fix Non Return Sluice Valve Class PN 1.6, 80 mm complete all as specified and directed
M&L for Leakage detection in PVC / GI pipe line upto 150 mm bore and necessary repairs including cutting, threading for addition/alteration and insertion of fittings all as specified and directed. Note: Materials for replacement will be supplied and measured separately.
Quarterly maintenance, servicing of RO Plant of 1000 LPH at azadhind nagar including necessary inspection, testing and minor repaire, fixing all pipe fitting properly so that fully plant leakage free and smoothly operated. Note : (i) All minor alteration, cleaning all pipe fittings, pipes, pumps, panels,replacement of gasket, disassembling the pipe fitting and re fixing the complete pipe fitting with all necessory parts required to make leakage free complete system all are included in quoted rate. (ii) Replacement of Major parts meausre separately and paid separatyely.
all as per above item No 136 but for the RO Plant 800 LPH capacity at Vikram Enclave complete all as specified and as directed.
M & L for Repaired and Maintenance of fire alarm system at Azadhind Nagar (Netaji & Bapuji Bldg), Jetty (Technical Bldg) including necessary inspection, testing and minor repair to manual call points, hooter, fire detector, fire alarm panel, transmitter, DC battery to keep the complete system serviceable including following works to be carried. Note: (i) checking of battery specific gravity, battery charging circuit, checking of wiring circuit of fire alarm system, manual call points, fire alarm panel and zonal panels all are included in quoted rate. (ii) Replacement of necessary borken/damaged cover glass, switch, spring, as and when/where required are included in quoted rate. (iii) Non Attending of system breakdown will attract penalty @ Rs 1000/- per day.
M & L for Repaired and Maintenance of fire fighting system at Azadhind Nagar, Jetty area, Vikram Enclave and DHQ including necessary inspection, testing and minor repair to fire hydrant, fire hose box, fire pumps, fire panels, fire hose, fire pipes etc to keep the complete system serviceable including following works to be carried. Note : (i) Checking of all fire pumps connection, noise, vibration, starter panel, voltmeter, Ammeter, electrical control panel, batteries, fan belt, temperature gauge, fuel gauge of diesel engine, diesel tank flow pipe condition, display pipe condition all are included in quoted prices. (ii) Servicing of all Gate / Butterfly Valves, Non return Valves, Air Vessel, Pressure Gauges, Pressure Switches and other related accessories therein, servicing/ cleaning/ color of Delivery Hose coupling Lugs, coupling washers, Binding state of Delivery hoses, Hose Cabinets/Boxes, Intactness of glasses of Hose Boxes all are included quoted prices. (iii) Replacement of broken glass of hose cabinet and manual call point, pumps and valves gaskets, greasing of all pumps shaft, cleaning of all pumps all are included in quoted prices. (iv) Replacement of all minor parts and spares such as gasket, oil grease & gland packing, polish paper, distilled water for battery terminals, cotton cloth and all types of washers of valves would be done at no extra cost and as and when required. (v) Non Attending of system breakdown will attract penalty @ Rs 1000/- per day.
M & L for 150 mm dia Cast Iron Foot Valve flanged end and remove the unsv complete all as specified and directed.
Supply and fixed cable lugs suitble for aluminium cable of size 25Sqmm to 120 Sqmm complete all as specified and as directed.
Supply and fixed cable lugs suitble for aluminium cable of size 150 Sqmm to 300 Sqmm complete all as specified and as directed.
Supply and fixed cable ferrule suitble for aluminium cable of size 25Sqmm to 120 Sqmm complete all as specified and as directed.
Supply and fixed cable ferrule suitble for aluminium cable of size 150Sqmm to 300 Sqmm complete all as specified and as directed.
Material and labour for repair and maintenance of the high mast of any height and any description by lowering the mast using hydra/manual or any other methos without damaging the pole and dismentling the high mast pole and light light with safty including up and down , rope, servicing and repairs the gear box and motor complete all as specified and as directde. Note:- Replacement of mast rope, cable, and flood light shall be measured and paid separatly underv revelant Itms.
M & L for 50 mm dia Cast Iron Foot Valve flanged end and remove the unsv complete all as specified and directed.
M & L Tank cleaning of 1000ltr RO tank/ overhead tank for centrifugal pump complete all as specified and directed.
ARJUN DAS VALECHA (BID ID -3125250)
M/S L.R.ENTERPRISES (BID ID -3125014)
JAGATMATA ENTERPRISE (BID ID -3124554)
DUTTA & DUTTA (BID ID -3125460)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .