CWE A JAISALMER
Commander Works Engineer (A) Jaisalmer C/O 56 APO
REPAIR AND MAINTENANCE OF MAIN RECEIVING STATION SWITCH YARD AND MISC WORK AT CERTAIN AREA OF MIL STN JAISALMER UNDER GE (A) JAISALMER
2021_MES_489477_1
83994
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAISALMER
Please refer tender documents
10 documents required · 10 mandatory
₹500
Yes
GE A JAISALMER
₹40,000
Yes
2 Feb 2022
20 Nov 2021
21 Dec 2021
20 Nov 2021
18 Dec 2021
5 Dec 2021
Amount
Caliberation/Servicing/Overhauling & testing and commissioning of factory manufactured, HT 11 KV Phase 3 wire 50 C/S 400 Amps, 18.4 KA single panel switch board, vertical isolation and horizontal draw out type vaccum circuit breaker (VCB) confirming to IS-13118, EIC-56 totally enclosed, single busbar floor mounting metal clad indoor extendible fully interlock complte comprising the following :- (a) CTs primary current injection test . (b) IR values of CTs (c) Ratio test of PTs and IR value (d) Protection relays testing through secondary current injection kit (e) Voltmeter, ammeter functional testing (f) Breaker testing for tripping time, closing time, contact resistance values and physically healthyness of Vaccum interuptor. Note:- 1. Wiring of Control Panels of VCBs, wiring of WTI, OTI, CTs, PTs will be including quoted rate. 2. Contractor will be responsible for arranging the expert for checking and rectification/Alteration of control wiring of safety relays.
Supply & Fixing in repair post insulator, porcelain, vitreous, with hardware fitting complete for 33000 volts grade all as specified & directed by Engr-in-Charge.
Supply & Fixing in repair/Replacement of lightening arrestors 33 KV, 10 KA, LD Class 2 Station type Class including all clamps, nuts, bolts and washers and connection to earth with 32x6mm GI strip complete all as specified & directed by Engr-in-Charge. Make-OBLUM, Jaipuria Brothers or equivalent.
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (as per site) & 3 insulators double stack type rotating type and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 33000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including DO & drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately). Make-OBLUM, Jaipuria Brothers or equivalent.
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (as per site) & 6 insulators double stack type rotating type and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including DO & drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately). Make-OBLUM, Jaipuria Brothers or equivalent.
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (as per site) & 9 insulators double stack type rotating type and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including DO & drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately). Make-OBLUM, Jaipuria Brothers or equivalent.
S&F in repair, Annunciator Box consisting of 4 output, 4 stage, 220 volts, 50Hz complete in existing VCB of CG make all as specified & directed by Engr-in-Charge. Make :- Minilec, Alan or equivalent.
S&F in repair, Master Trip relay 24 Volts DC complete in existing VCB of CG make all as specified & directed by Engr-in-Charge. Make :- Easun Reyrolle, Schneider, Alstom, ABB or equivalent.
S&F in repair Auxilary relay 110 Volts DC complete in existing VCB of CG make all as specified & directed by Engr-in-Charge. Make :- Alstom, Ashida, Easuna Reyrolle, Schneider or equivalent.
S & F in repair of Voltmeter for VCB 11 KV, 110 Volts complete all as specified and directed by Engr-in-Charge. Make:- AE, Siemens, Power India or equivalent.
S & F in repair of Ampere Meter for VCB 11 KV, 110 Volts complete all as specified and directed by Engr-in-Charge. Make:- AE, Siemens, Power India or equivalent.
S&F in repair, Indication Lamp RGB with holder complete 110 Volts DC complete in existing VCB of CG make all as specified & directed by Engr-in-Charge.
S & F in repair of HRC Fuse 5 Amps, 240 Volts complete all as specified and directed by Engr-in-Charge. Make :- L&T, Eaton, ABB, C&S or equivalent.
S&F in repair, Multi Functional meter for 11 KV VCB complete in existing VCB of CG make all as specified & directed by Engr-in-Charge. Make :- Scheinder, Secure, Sai Creation Ghaziabad or equivalent.
Supply and fixing in repair of Over Current and Earth fault IDMT protection relay (digital relay) type CGI 14 N,24/110 Volts complete necessary connection and testing in existing VCB of CG make all as specified and directed by Engr-in-Charge. Make : Crompton Greeves, ABB, L&T, Alstom or equivalent.
Supply and fixing in repair Universal Motor (spring charge for 11 KV VCB) 220 volt AC/DC type PMR5 in existing VCB of CG Make- Delco, Siemens, BHEL or equivalent.
S&F in repair PT fuse suitable for 33/11 KV in existing VCB of CG make complete all as specified and directed by Engr-in-Charge.
Dehydration of transformer oil (mounted on poles/platform/Power Transformer etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV complete all as specified and directed by Engr-in-Charge.
Supply, filling & topping up of transformer oil of dielectric strength 50 KV minimum for voltage stablizer, transformer, OCB's and PTS complete all as specified & directed by Engr-in-Charge. Make:- Apar, Power, Velvex
S&F in repair TNC switch suitable for vacuum circuit breaker 11 KV, 110 Volts, DC complete and taking down existing switch all as specified & directed by Engr-in-Charge.
S&F in repair TNC switch suitable for vacuum circuit breaker 11 KV, 24 Volts, DC complete and taking down existing switch all as specified & directed by Engr-in-Charge.
S&F tripping coil/Closing coil suitable for 24 Volts complete and taking down existing coil all as specified & directed by Engr-in-Charge.
S&F tripping coil/Closing coil suitable for 110 Volts complete and taking down existing coil all as specified & directed by Engr-in-Charge.
Supply, Jointing and testing outdoor type cable termination heat shrinkable joint kit suitable for size 95 Sq mm 3 core 11KV (unearthed cable) under ground XLPE cable all as directed by Engr-in-Charge. Make: Denson, 3M, Raychem
All as per item No 25 above but size of 185 Sqmm 3 Core. Make: Denson, 3M, Raychem
Supply, Jointing and testing indoor type cable termination heat shrinkable joint kit suitable for 95 Sq mm 3 core 11 KV (unearthed cable) under ground XLPE cable all as directed by Engr-in-Charge. Make: Denson, 3M, Raychem
All as per item No 27 above but size of 185 Sqmm 3 Core . Make: Denson, 3M, Raychem
Supply jointing and testing straight through heat shrinkable joint kit suitable for 95 Sq mm 3 core 11 KV (unearthed cable) under ground XLPE cable complete all as directed by Engr-in-Charge. Make: Denson, 3M, Raychem
All as per item No 29 above but size of 185 Sqmm 3 Core . Make: Denson, 3M, Raychem
S&F in repair 36 KV, 50Hz outdoor type double winding, Single Phase Potential Transformer ratio 3300/√3/110/√3,110/√3 insulation level 70/170, insulation class B, HSV-36,OVF-1.2 constant & 1.5 for 30S class 0.5,3P, Burden 100 VA complete all as specified and directed by Engr-in-Charge. Make : ETC Ghaziabad, Ereva, Electro, Savio equivalent.
S&F in repair 12 KV, 50Hz outdoor type double winding, Single Phase Potential Transformer ratio 11KV/√3/110Volt/√3,110Volt/√3, class 1, 3P,Burden 100 VA complete all as specified and directed by Engr-in-Charge. Make : ETC Ghaziabad, Ereva, Electro, Savio or equivalent.
S&F in repair 11 KV Indoor type CTs as per IS-2705 suitable for 60/5-5 for VCB complete all as specified and directed by Engr-in-Charge. Make : ETC Ghaziabad, Ereva, Electro, Savio or equivalent.
S&F in repair 11 KV Indoor type CTs as per IS-2705 suitable for 100/5-5 for VCB complete all as specified and directed by Engr-in-Charge. Make : ETC Ghaziabad, Ereva, Electro, Savio or equivalent.
S&F in repair 11 KV Indoor type CTs as per IS-2705 suitable for 200/5-5 for VCB complete all as specified and directed by Engr-in-Charge. Make : ETC Ghaziabad, Ereva, Electro, Savio or equivalent.
Supply and Fixing of Battery Bank 110 Volt DC-55 Nos (2 Volt, 100 AH) Tubular maintenance free batteries, battery Bank and taking old unsv Battery Bank with accessories and charger complete all as specified and directed by Engr-in-Charge. Make :- AMARA RAJA, AMRON.
Sypply and Fixing in repair Battery Charger of capacity 110Volt/20A (output), input 220Volt AC 10% Single Phase 50Hz Boost Current 20Amp - Float Current 2 Amp or as per battery requirement for 110 Volt battery bank of 100 AH cap type SMF complete all as specified and directed by Engr-in-Charge. Make :- VOLSTAT, Powertron, GSA or equivalent.
Supply, laying & testing PVC sheathed cable galvanised steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor up to 1100Volts grade fixing with gland including taking down of old cable of following sizes:-
2.5 sqmm 12 core (Each core single strand) IS 1554-Pt-1 1988 ISI Marked. Make Grandlay,Havells,Finolex.
2.5 sqmm 20 core (Each core single strand) IS 1554-Pt-1 1988 ISI Marked. Make Grandlay,Havells,Finolex.
Supply only Aluminium Sector lugs long barrel suitable of size of following Make:- Dowells, Burndy, Aera or equivalent:-
35 sqmm 3.5 Core
50 sqmm 3.5 Core
70 sqmm 3.5 Core
95 sqmm 3.5 Core
120 sqmm 3.5 Core
240 sqmm 3.5 Core
300 sqmm 3.5 Core
400 sqmm 3.5 Core
Supply only Adhesive Electric Insulation Tape of size 0.125cm thickness x 1.8cm width x 7.5m length in RYB & Black Colour complete all as specified and directed by Engr-in-Charge. Make :- 3M, Anchor, Steelgrip.
M/s Yash Electrical and Maintenance
Anil Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .