| 1 | L1₹22.9 LAccepted-AOC C O ANU REFRIGERATION WORKS GANDHI CHOWK PATHANKOT GANDHI CHOWK PATHANAKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹23.1 L+₹18,125 (0.79%)Rejected-Finance 451 NEAR RADHA KRISHAN MANDIR VPO MAMUN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than lowest tenderer hence rejected | |
| 3 | L3₹24.8 L+₹1.9 L (8.42%)Rejected-Finance MASTER BUILDING DALHOUSIE ROAD DALHOUSIE ROAD PATHANKOT PATHANKOT GURDASPUR PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than lowest tenderer hence rejected | |
| 4 | L4₹32.1 L+₹9.2 L (40.3%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Other than lowest tenderer hence rejected | |
| 5 | L5₹32.2 L+₹9.3 L (40.8%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer hence rejected |
Tender Value
₹24.9 L
EMD Value
₹49,800
Closing Date
26 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HEADQUARTERS CWE MAMUN PIN-145001
REPAIR/MAINTENANCE/REPLACEMENT OF HT ELECTRICAL SYSTEM OF D-III ZONE, D-IV ZONE AND MAP BHASKAR UNDER AGE EM-I OF GE(N) MAMUN
2023_MES_625823_2
CWE/M-31/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (N) Mamun
Class E Category b ii
8 documents required · 8 mandatory
₹500
GE (N) Mamun
₹49,800
Yes
23 Mar 2024
1 Feb 2024
4 Mar 2024
1 Feb 2024
26 Feb 2024
12 Feb 2024
Amount
Dismantling air beark switch with all accessories such as insulators with mountings, all current carrying parts,GI pipe etc ON-OFF handle complete set, all as specified and directed.
Supply, installation, commissioning and testing 11 KV Air break switch, gang operated for current rating upto 200 Amps, triple pole, horizontal type, mechanically operated with accessories such as polymer insulator assembly (Set of 15 insulators), All current carrying parts shall be of non-ferrous metal or alloys and shall be designed to limit sharp points/edges, A set of adjustable arcing horns made from 2 SWG GI wire shall be mounted on each insulator stack of G.O pad-locking arrangement for both ‘ON and OFF’ positions, operating mechanism worked from ground level, Height of operating handle may vary from 1000 to 1300mm, GI tubing 20mm bore (heavy grade) for connecting operating handle, pad-locking arrangement shall be provided for both ‘ON and OFF’ positions drop out fuse. All steel parts are applied of two coats of aluminium paint over a coat of primer complete all as specified and dire
Supply and replacing indicator lamp assembly LED type of HT panels complete all as specified and directed.
Supply, fixing and testing in repalcement motor of vacuum circuit breaker for spring charging including and after taking out old unserviceable one carefully removing all connections and checking all wiring connection and to ensure functioning of other related parts, repair if any minor faults complete all as specified and directed.
Taking down after disconnecting all the cables and earthing connections from 11/0.433 KV unserviceable transformer from platform of capacity upto100 KVA and shifting to workshop including loading unloading carefully by manual or mechanical means and refixing and testing after repair works complete all as specified and directed. Note: Cost of repair shall be measured and paid under relevant items
All as per srl item No 5 here-in-above but cap of transformer above 100KVA and upto 200 KVA complete all as specified and directed.
All as per srl item No 5 here-in-above but cap of transformer above 200KVA and upto 315 KVA complete all as specified and directed.
All as per srl item No 5 here-in-above but cap of transformer above 315KVA and upto 500 KVA complete all as specified and directed.
All as per srl item No 5 here-in-above but cap of transformer above 500 KVA and upto 750 KVA complete all as specified and directed.
Opening up to 100KVA transformer cover along with the conservator by removing the nuts bolts, removing the internal H.T. & L.T. connections from studs, bushings, taking out the core-winding assembly out of the tank, draining & decanting of transformer oil and cleaning of sludge deposited in the tank with CTC. Checking the serviceability of all HT & LT coils. Replace the coils if requires. Heating of core winding assembly in hot chamber for 48 hours and removing all the moisture present in it, Sealing of tank if any leakage by welding, checking of HT & LT bushings, conservator tank, valve, breather assembly and repair if any leakage, refilling transformer oil and putting the core-winding assembly into the tank, fixing all bushings, connecting all HT & LT wires, reassembling, bushings, replacing gaskets of top cover, fixing top cover , testing the transformer in the workshop duly filled with oil, topping up of oil if required, dehydration of transformer oil to acheive required insulation level of 40 KV in 2.5 mm gap all as specified and directed. Note : (i) Items required for repairs including copper wire/strip required for rewinding of transformer shall be measured and paid separately under relevant item of this schedule. (ii) Repair of the transformer will be carried out at auth workshop. GE/ AGE E/M will visit to workshop before repair of transformer and certificate of auth workshop shall be submitted by the contractor.
All as mentioned in item No 10 here in above but transformer capacity above100 KVA and upto 200 KVA
All as mentioned in item No 10 here in above but transformer capacity above 200 KVA and upto 315 KVA
All as mentioned in item No 10 here in above but transformer capacity above 315 KVA and upto 500 KVA
All as mentioned in item No 10 here in above but transformer capacity above 500 KVA and upto 750 KVA
Supply in replacement of super enamelled copper winding wire/ strip of any size for H.T. coils of transformers all as specified.
Supply in replacement super enamelled aluminium winding wire/ strip of any size for H.T. coils of transformers all as specified.
Supply in replacement copper winding strip/wire of any size for L.T. coils of transformers including providing insulation all as required.
Supply in replacement of aluminium winding strip/wire of any size for L.T. coils of transformers including providing insulation all as required.
Supply and fixing in replacement of LT bushings 433 V of suitable size for outdoor/ indoor type transformer of the capacity Upto 100KVA, complete all as specified and directed.
All as mentioned in item No 19 here in above but transformer capacity above100 KVA and upto 200 KVA
All as mentioned in item No 19 here in above but transformer capacity above 200KVA and upto 315KVA
All as mentioned in item No 19 here in above but transformer capacity above 315KVA and upto 500KVA
All as mentioned in item No 19 here in above but transformer capacity above 500 KVA and upto 750 KVA
Supply and fixing in replacement of HT bushings 11KV of suitable size for outdoor type transformer upto 100KVA, complete all as specified and directed.
All as mentioned in item No 24 here in above but transformer capacity above100 KVA and upto 200 KVA
All as mentioned in item No 24 here in above but transformer capacity above 200KVA and upto 315KVA
All as mentioned in item No 24 here in above but transformer capacity above 315KVA and upto 500KVA
All as mentioned in item No 24 here in above but transformer capacity above 500 KVA and upto 750 KVA
Supply and fixing in replacement of brass stud (for LT 433V side) of suitable size complete with one check nut, two nuts, washers and rubber seal, all as per sample for outdoor/indoor type transformer of the capacity upto 100KVA, complete all as specified and directed.
All as mentioned in item No 29 here in above but transformer capacity above100 KVA and upto 200 KVA
All as mentioned in item No 29 here in above but transformer capacity above 200KVA and upto 315KVA
All as mentioned in item No 29 here in above but transformer capacity above 315KVA and upto 500KVA
All as mentioned in item No 29 here in above but transformer capacity above 500 KVA and upto 750 KVA
Supply and fixing in replacement of brass stud (for HT 11KV side) of suitable size complete with one check nut, two nuts, washers and rubber seal, all as per sample for outdoor/indoor type transformer of the capacity upto 100 KVA, complete all as specified and directed.
All as mentioned in item No 34 here in above but transformer capacity above100 KVA and upto 200 KVA
All as mentioned in item No 34 here in above but transformer capacity above 200KVA and upto 315KVA
All as mentioned in item No 34 here in above but transformer capacity above 315KVA and upto 500KVA
All as mentioned in item No 34 here in above but transformer capacity above 500 KVA and upto 750 KVA
Material and labour for Servicing and checking of 630 Amp, 250 MVA, 11 KV indoor type VCB of any make and type with blower, cleaning of existing HT panel inside with air blower and removing dust particles , CTC/CRC/Thinner as required. Outside with tighting of all bus bar, nut & bolt, alignment, adjustment of gaps between phase to phase, Checking and tightening of control wiring circuit as charging motor closing coil and tripping coil circuit, Manually tripping testing of VCB, Cleaning, removal of dust and dirt to male/Female contacts, greasing & lubrication all moving fixed part including replacement of minor parts such as spring, washers etc. for smooth mechanical operation etc. complete with testing commissioning as required. Servicing, Calibration, testing of 2 element IDMT relay ( one earth fault one over current) with secondary injection testing of VCB 11 KV Operational testing through relay front pad as well as push button, Testing/ Calibration of safety relays through secondary injection kit, Tripping testing of VCB through over current and earth fault relay, Tripping testing through primary injection , Opening of HT panel, Removal of moisture in bus bar, insulator HT cable box and heating of P.T., C.T Chamber, Relay setting. Of 11 KV VCB Panel complete with High Pressure testing, Meggering etc. all as specified and directed.
Supply, Install and testing Vacuum Interrupter,11 KV, 50/60 Hz, Max line voltage 12 KV, rated normal current 2000A for using in11 KV VCBs shall comply with the requirements of type tests as per the latest edition of relevant ISS/BS/IES, it should have make, place(s) of manufacture as well as the places of testing and inspection of the equipment all as specified and directed.
Supply and fixing in replacement of oil level indicator for transformer of cap upto 750KVA all as per existing and having level marking 1/4, 1/2, 3/4 and full all as directed by Engr-in-Charge or required at site.
Supply and fixing in replacement of breather assy for transformer of capacity upto 750KVA all as per existing all as directed by Engr-in-Charge or required at site.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m or for disposal for taking credit to contractor all as specified and as directed
Fixing only the cross arms items retrieved from item No 46 here in above with supports/ angle iron frame etc including nut, bolt, washer, welding, bending, hot or cold drilling holes for fixing insulators ,bolts in any size or shape complete all as specified and as directed.
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Material and labour for brick work all around 2 pole structure of sizes 4x2.5x0.60m for paving gravel incl PCC work and plastering work including dismantling and removing old bricks and including painting work all as specified and directed. Note: The height of brick wall is 0.30 M below the ground level and 0.30M above the ground level.
Material and labour for brick work all around 4 pole structure of sizes 4x4x0.60m for paving gravel incl PCC work and plastering work including dismantling and removing old bricks and including painting work all as specified and directed. Note: The height of brick wall is 0.30M below the ground level and 0.30M above the ground level.
Material and labour for coarse aggregate nominal size not less than 40 mm graded including spreading and levelling complete all as specified and directed by Engr-in-Charge.
Removal of coarse aggregate of any size laid at various MES installations and around 2/4 pole structures including and after segregation of and removal of vegitation, bushes, small plants etc and after that spreading the coarse aggregate at the same location including levelling and removing the vegitation /bushes/ small plants etc to a distance not exc 50m all as specified and directed by Engr-in-Charge.
Taking out of HT cable of any size and type from duct/cable trench/on wall/on pole carefully including disconnection by means of removing all connected items , kept aside including stacking for re-use or for taking credit to contractor all as specified and directed.
Laying only cable retrieved from item No 50 here in above carefully in trench/duct/floor/wall/pole carefully including and after tracing out fault and removing the portion if any, connecting and testing complete all as specified and as directed by Engr-in-Charge. Note: Earth work shall be measured and paid seperately under relevant items.
Supply, laying, connecting, testing and commissioning of cable HT 11 KV, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor of size 95 Sqmm 3 core,11KV grade, (UE) with aluminium conductor all as specified and directed.
All as mentioned in item No 52 here in above but cable size of 185 sq mm
All as mentioned in item No 52 here in above but cable size of 240 sq mm
Supply and laying synthetic rubber insulated mats 2.5mm thick for voltage upto 11KV size(2mx1m) for electrical purpose suitable for electrical shock safety all as specified and directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of earth plate not less than 1.5 meters below ground level connected by 32 X6 mm GI strip as earth lead by means of GI nuts and bolt,check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20 mm graded stone aggregate,with fair finish,internal dimension of concrete chamber shall be 300x300x300 mm size duly plastered with 15 mm thick CM 1:4, funnel with wire guage mesh, 30mm thick PCC pit cover with iron rod handle.earth plate surrounded by charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part -1 (2009) and specified including provision of GI strip upto equipment protected by 40 mm dia medium grade pipe up to text point and watering pipe shall be 20 mm bore medium grade ,including all excavation , earth work and connecting the strip to test point/equipment as specified and testing on completion complete all as specified and directed by Engr-in-Charge.
Material and labour for Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connecting to Galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth lead protected by provision of GI medium grade pipe 15mm bore dia including 30mm thick PCC pit cover with iron handle reinforced and frame of angle iron 40mmx40mmx6mm with 6mm dia, GI medium grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil including returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I (specificetion) including provision of GI wire up to equipment and connecting to test point all as specified or indicated including testing on completion complete all as specified and as directed by Engr-in-charge
Material and labour for detection of fault in LT/HT underground cable laid in plane or any type area with the help of Cable fault locator machine including providing conveyance and any other means required at site, isolating and re connecting cable after identifying fault all as specified and as directed. Note: The fault should be attended within 12 hours of intimation
Material and labour for dismantling old unserviceable steel/PCC pole of any size any length including shifting and stacking at place where directed for taking credit to contractor all as specified and directed.
Material and labour for erection of steel tubular swaged pole 11 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55 duly applied a coat of redoxide primer (internally and externally). The pole shall be painted (above coping) with 5 Nos of circular strips each of 30 cm (of colour combination as directed) with synthetic enamel paint duly pole number marking in approved pattern. The remaining pole shall be painted with two coats of aluminium paint complete all as specified and directed.
Taking down carefully aluminium conductor of any size from OH Lines (running on 9/11 poles) after unbinding from insulators for replacement of unserviceable conductors, complete all as specified and directed.
Restringing and restretching the aluminium conductor reterived from item No 61 including necessary binding with insulators using alunimium binding wire, connections of incoming and out going cables complete all as specified and directed.
Material and labour for ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed.
Restretching aluminium conductors or GI wire on existing over head lines running on 11 Mtrs poles in situation by means of unbinding and rebinding with insulator using fresh aluminium binding wire , including jointing all cable connections , binding with spacers where required, complete all as specified. Note:- All ACSR conductors and GI guard wire between two poles will be measured as one span.
Trimming up of tree branches upto 5 mtr all around LT/HT overhead lines, removing cut branches from site complete all as directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 5 mtr all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department accordingly. The trimming work shall be commenced once it is permitted by AGE.(ii) only effective length i.e length where tree branches are touching LT line or neaby HT line shall only be measured & paid under this item. No claim whatsoever shall be entertained by the deptt at later stage. (iii) Fortnightly inspection of lines will be made jointly by contractor or his authorised rep and rep of Engr-in-Charge and outcome whether lines are free from tree branches or not kept on record for payment. (iv) The OH line will be maintained for whole period of contract and full payment will be made with Final Bill only. The payment for the period for which line not maintained will be deducted proportionately based on fortnightly inspection carried out as detailed above.
Dismantling insulators of any type and size from 11 KV OH line all as specified and directed
Fixing only insulator retrieved from item No 66 including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade, all as specified and directed.
Material and labour for polymeric Pin type,insulator, 11 KV, 5 KN including connected accessories, insulator shall be legibly and indelibly marked (embossing/ engraved) to show the name & Trade mark of the manufacturer, complete all as specified and directed.
Material and labour for Disc type insulator, 45 KN with fitting T&C / B&S type assembly for tension with tension clamps for conductors, working pressure 11000 volts, insulator shall be legibly and indelibly marked (embossing/engraved) to show the name & Trade mark of the manufacturer, complete all as specified and directed.
Material and labour in replacement porcelain post insulator, 11 KV working voltage, creepage distance 320 mm, diameter 150 mm all as specified and directed.
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sqmm, complete all as specified and directed
All as mentioned in item No 71 here in above but for size 120 Sqmm to 185 sqmm 3 core.
All as mentioned in item No 71 here in above but for size 240 Sqmm to 300 Sqmm 3 core.
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sqmm, complete all as specified and directed
All as mentioned in item No 74 here in above but for size 120 Sqmm to 185 sqmm 3 core.
All as mentioned in item No 74 here in above but for size 240 Sqmm to 300 Sqmm 3 core.
Material and labour for Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 400 sqmm, complete all as specified and directed
Dismantling stay assembly complete including excavation for taking out PCC block breaking of PCC block for taking out MS plate and removing u/s item i.e iron items or PCC from site, complete all as specified & directed.
Material and labour for stay assembly complete with MS stay plate of size 300x300x6mm thick, stay rod 20 mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I of 2009 all as specified and directed. Note: Excavation, PCC, saty wire and loop type insulators will be measured separately.
Material and labour in replacement galvanized stay strand of size 7/4 mm all as specified and directed.
Material and labour for GI tubing light grade 100 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.
Dismantling of Male contact, Female contact, copper belt , belt carrier and back connector plate and pedastel Insulator etc all as specified and directed.
Supply and fixing of Male Contact / moving contact blade with arching horn having brass contacts suitable for 11 KV GOD, including galvanised iron bolts, nuts and washers for fixing on post insulator or any other indicated situation all as specified and directed.
Supply and fixing of Female contact spring loaded having brass contacts suitable for 11 KV GOD, including galvanised iron bolts, nuts and washers for fixing on post insulator or any other indicated situation all as specified and directed.
Supply and fixing of tinned Copper braided flexible belt or jumper 200 Amp/400 Amp, suitable for 11 KV GOD, including galvanised iron bolts, nuts and washers for fixing all as specified and directed.
Supply and fixing of MS Jumper Carrier for carrying copper braided belt , suitable for 11 KV GOD, including galvanised iron bolts, nuts and washers for fixing all as specified and directed.
Supply and fixing of Back connector plate, suitable for 11 KV GOD, including galvanised iron bolts, nuts and washers for fixing all as specified and as directed.
Material and labour for dehydration and filtration of transformer oil at site by means of machine including testing of transformer oil 500 ml sample before and after dehydration and filtration to acheive 40 KV at 2.5 mm gap complete all as specified and directed.
Supply and filling/Toping up of transformer oil including testing before filling to achieve 50 KV at 2.5 mm gap complete all as specified and as directed.
Material and Labour for Preparation of old painted surfaces and cooling coils/ fins of transformers of upto 100 KVA ( incl. 100 KVA) capacity by removing oil marks using chemical or hot blow lamp. Spray painting to prepared surfaces using synthetic enamel paint of superior quality of colour as approved by GE / AGE E/M as per standard engineering practice with two coats (smoke grey), writing SM No, MES No, Make and capacity with white paint having height of each letter not less than 2.5cm and width not less than 1cm complete all as specified & directed. Note: Shutdown of HT/LT line shall be taken by contractor in writing from MES rep
All as mentioned in item No 90 here in above but size above 100 KVA upto 200 KVA
All as mentioned in item No 90 here in above but size above 200 KVA upto 315 KVA
All as mentioned in item No 90 here in above but size above 315 KVA upto 500 KVA
All as mentioned in item No 90 here in above but size above 500 KVA upto 750 KVA
Supply and filling up in replacement silica gel superior quality to transformer breather assy complete all as specified and directed.
Excavation in trenches in any type soil n. exc. 1.5 Mtr in width and not exceeding1.5 Mtr in depth and getting out all as required for laying of cable/ poles complete all as specified and directed.
Excavation in trenches in soft/loose soil n. exc. 1.5 Mtr in width and exc. 1.5 Mtr but not exc. 3.00 Mtr in depth and getting out all as required for laying of cable/ poles complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed.
Returing filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required complete all as specified and directed.
Supply and laying unreinforced precast cement concrete cable cover, class HV, type 1 with flat, size 300 mm x 180mmx 40mm all as required as in protection of cable complete all as specified and directed.
Material and Labour or sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable all as direted. Note :Only punned thickness i.e 18cm shall be measered and paid.
Material and labour for plain cement concrete (1:4:8) type D-2 with using 40mm graded stone aggregate as in foundations and mass concrete etc complete all as specified and directed.
Material & labour for plain cement concrete (1:3:6) type C-1 with using 20mm graded stone aggregate as in foundation of stay, complete all as specified and directed.
Material & labour for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregrate as in coping of poles etc including necessary form work, complete all as specified and directed.
Supply, fixing, commissioning and testing of HT busbar chamber factory made, powdered coated, CPRI approved, floor mounting outdoor type, double door rust proof/dust proof with provn of rubber gasket and locking arrangement incl making connection with suitable size thimble ,gland etc incl dismantling existing old busbar, necessary earth work, cubical panel fabricated out of 3.15mm thick CRCA sheet suitable for 11000Volts ,3 phase,weather proof and vermin proof ,fabricated on 50x50x4mm thick MS angle iron frame of size 75cm complete,high tension supply comprising of capacity 200 Amps(3 Strip) aluminium busbar colour code for phase mounted on post insulators complete including painting internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer and all as specified and directed.
Supply, laying, connecting, testing and commissioning cable (jumper lead) HT 11KV, stranded compacted circular 150sqmm aluminium conductor,single core,screen with extruded semi conducting compound,XLPE insulated ,insulation screening with extucted semi conducting compound in combination with copper tape,all round wire armoured with aluminium lux on termination and over all PVC sheathed cable for using HT jumper lead complete all as specified and directed.
Material and labour for spray painting using synthetic enamel paint of superior quality on prepared surfaces as priming with one coat of red oxide scraping of old rusted surfaces of LT/HT panel/busbar chamber, Paint colour and quality as approved by GE/Engr-in-Charge as per standard engineering practice with two coats all as specified and directed.
Material and labour for danger notice plate of 1.6mm thick mild steel sheet,vitereous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved size for HT 25x20cm all as specified and directed.
Material and labour for anti climbing device spikes type fabricated out of MS bars (round ,square and flat) including nuts,bolts,washers and welding in two halves made to shape to suit the cross section of the pole all as specified and directed.
Material and labour for Painting of PCC pole upto 9/11m height with out removing accesseries with one coat of alternative white and green (or as approved colour) straps of 30cm each upto 1.5m height by using synthetic enamell paint. Two coat of colour washinging the pole above 1.5m height using snowcem of approved colour including painting the steel parts by appliying one coat of alluminum paint including writing pole No etc all as specified and directed.
Material and labour in replacement HT post insulator,11 KV, 5 KN after disconnecting and taking out of HT cables from HT busbar including making cable connection and testing complete all as specified and directed.
Material and labour for Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm, complete all as specified and directed
Material and labour for Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 sqmm, complete all as specified and directed
RD Engineers
INDIA ELECTRIC WORKS
kailu construction co
vivek and co
satpal and brothers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .