EE JS Div Matiana
JS Div Matiana
Prov. LWSS Kingal Khad to Shalouta in GP Shalouta, Tehsil Kumarsain, Distt. Shimla HP SH C O Head weir, RCC Intake, storage tanks of 160000 Ltrs., 90000 Ltrs. capacity, C O Sump well of 160000 Ltrs. cap., Retaining walls, development of site, C O Fi
2022_HPIPH_56815_1
JSV-DM-9973-78/2
Open Tender
Civil Works - Water Works
Item Rate
365 days
Shalouta
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,500
Yes
EE Matiana
₹1.5 L
Yes
19 Sept 2022
15 Feb 2022
25 Feb 2022
15 Feb 2022
24 Feb 2022
15 Feb 2022
Amount
Cutting in earth work in all kinds of soil such as pick work, jumper work, blasting work and chiselling work etc. and disposal of excavated earth as directed within all leads and lifts. In Pick Jumper work 50% each.
Excavation in foundation and trenches in earth work upto all depth in all kinds of soil such as pick work jumper work,blasting work,chiselling of soft /hard rock where blasting is prohibited in all leads and lifts and including trimming of ;sides levelling of bed to correct grade stacking the excavated soil in 15cm.layers when required into plinth sides of foundation including consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed in all leads and lifts in pick jumper work and soring/strutting timbering and dewatering where ever required to the entire satisfaction of the engineer-in-charge.
Providing and fixing Wire crates 15x15cm mash (wire) complete in all respects in all leads and lifts and to the entire satisfaction of the Engineer-in Charge.
Providing and fixing Wire crates (bolder) complete in all respects in all leads and lifts and to the entire satisfaction of the Engineer-in Charge.
Providing and laying cement concrete 1:6:12 (1cement:6sand:12graded stone agg.40mm nominal size)and curing complete excluding cost of centring and shuttering in: a) Foundation and plinth.
Prov. and laying cement concrete 1:3:6 (1cement:3sand:6 graded stone agg. 40mm nominal size) and curing complete excluding cost of centering and shuttering i/c all leads and lifts :-a) Foundation and plinth.
Prov. and laying cement concrete 1:4:8 (1cement:4sand:8graded stone agg. 40mm nominal size) and curing complete excluding cost of form work i/c all leads and lifts :-a) Foundation and plinth.
Prov. & Laying of cement concrete 1:5:10 (1cement: 5sand : 10 graded stone aggregate 40 mm nominal size) with 15% Plum in R./Wall & B/Wall.
P/F PVC pipe 100 mm dia for weap hole in R/wall complete in all respects in all leads and lifts and to the entire satisfaction of the Engineer-in Charge.
Boulder/Stone filling behind R/Wall complete in all respects in all leads and lifts and to the entire satisfaction of the Engineer-in Charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering, strutting , strutting and propping etc. with wooden, battens, and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs.and removal of the same for insitu reinforced concrete and plain concrete work including all leads and lifts in:-
a) foundation footings bases of columns etc. and the like mass concrete.
Flat surfaces such as soffits of suspended floors,roofs, landings, and the like:-i)Floors etc. upto 200mm in thickness.
Vertical surfaces such as soffits of suspended floors,roofs,landings and the like including attached pillasters,buttresses, plinth and string courses and the like.
Edge of Slab and break in floor 20 cm wide.
Column Pillar & posts upto floor two level square, rectangular, and polygonal in plan.
Beams, Cantilever Girders & lintals sides and soffits of beam, beam, haunching, cantilever, girders not exceeding one meter depth.
Slopping & battering surfaces
Stair cases (expect spiral stair cases) excluding landing
Providing form work of ordinary timber planking so as to give a rough finish including centring, shuttering,sturting and propping and centering below supporting floor to ceiling not exceeding 4 mtrs and removal of the same for insitu reinforced :- Arches beyond 6 mtr span.
Arches beyond 6 mtr span.
Prov. and laying cement concrete work 1:1 1/2: 3(1cement:1 1/2 sand:3 graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work i/c all leads and lifts complete in all respect.:- a) Foundation and plinth.
a) Foundation and plinth.
b) Walls (any thickness) but not less than 0.1 m thickness)attached pillasters,buttresses, plinth and string courses etc.from top of foundation level upto floor two level.
b)Beams, centilevers girders and lintels sides and soffits of beams, haunching, centilever, girders brassumers and lintles not exceeding 1 mtrs. In depth.
Prov. and laying No fine concrete 1:6 (I cement:6 graded stone agrigate 40 mm nominal size) and curing complate. a) Walls (any thickness) complete in all respects in all leads and lifts and to the entire satisfaction of the Engineer-in Charge.
Prov. Mild steel/Tor steel reinforced for RCC work including bending, binding and placing in position complete upto floor two level i/c all leads and lifts complete in all respect. :- a) Tor steel.
Providing and laying cement concrete work 1:2:4(1cement:2sand:4 graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in in all respects in all leads and lifts and to the entire satisfaction of the Engineer-in Charge.
Foundation & plinth
a) Suspended floors, roofs, landings,shelves and their supports balconies, beams, girders, bressumers and cantilevers upto floor two level.
Arches upto floor two level
Columns,pillars,posts & struts upto floor two level up to floor two level.
Stair cases (except spiral stair cases) excluding landing I/c preparation of surfaces
Supplying & fixing MS Man hole cover using of angle iron frame 25x25x4 mm welded with MS sheet including painting with red oxide and black paint including locking arrangement complete in all respect and entire satisfaction of Engineer-in-charge.
Prov. RCC work smooth finishing of the exposed surface with cement mortar 1:3(1cement:3sand )complete in all leads & lifts complete in all respect and entire satisfaction of Engineer-in-charge..
Laying and Jointing in trenches, mild steel tubes (light grade) including tube fitting complete (earth work in trenches is to be measured and paid for saparately)
125 mm dia Gravity main with flanges.
100 mm dia
80 mm dia
65 mm dia
40 mm dia
32 mm dia
Providing and fixing brass stop cock, wheel valve of superior quality including fitting complete in all respect.
125 mm dia
65 mm dia
40 mm dia
32 mm dia
Constructing chamber for sluice valve, with CI surfaces box 100mm top dia. 160 mm bottom dia.& 180 mm deep (inside) with chained led RCC top 1:2:4 Mix (1 cement: 2 sand: 4 graded stone aggregate 20 mm niminal size) 100 mm thick foundation concrete 1:5:10 ( 1 cement: 5 sand: 10 graded stone aggregate 40 mm nominal size ) & inside plastering with cement mortar 1:3 (1 cement: 3 sand) finished with a floating coat of neat cement i/c curing completein all respect. 600x600x750 mm inside size with 150 mm thick walls of RCC 1:2:4 ((1 cement: 2 sand: 4 graded stone aggregate 20 mm niminal size) complete with form work & reinforcement with 6mm bars at not exceeding 150 mm centers both ways.
Providing and fixing of Cast Iron sluice valve with hand wheel) as per IS : 780-1984 calss I upto 300 mm dia (I/c brass spindle & as per 2906-1984 Class-II for dia >300n mm) complete with bolts, nuts, rubber insertion etc. (the tail piece if required shall be measured & paid for seperatly) including carriage of material within all leads and lifts complete in all respect as per the direction of the Engineer-in-charge.
125 mm dia
100 mm dia
80 mm dia
Precast concrete block masonry in partition walls 5 cm thick solid block of approved size including quion block closer etc. made of cement concrete 1:3:6 (1 cement :3 sand :6 graded stone aggregate 40 mm nominal size & down gueged) in CM 1:3 (1 cement : 3 sand).
Providing & placing in horizontal layers filtering media duly graded screened,washed and cleaned as specified by the Engineer-in-Charge in all leads and lifts.
Top layer Fine sand from approved quarry in all leads and lifts
2nd layer cource sand 3 mm to 6 mm from approved quarry in all leads and lifts.
3rd layer bajri 20mm to 25mm from approved quarry in all leads and lifts.
4th layer bajri 6mm to 20mm from approved quarry in all leads and lifts.
Bottom layer stone ballast 50 mm to 75 mm in all leads and lifts.
Steel work welded in built up sections,trusses and framed work,including cutting ,hoisting ,fixing in position and applying a priming coat of red lead paint. a) In gratings framed guard bars, ladders, railling, brackets and similar works. including carriage of material within all leads and lifts and as per direction of Engineer-in-charge.
Half Brick masonary using common burnt clay building bricks above plinth upto floor two level in cm 1:4(1cement:4sand)conventiohal brick first class including carriage of material within all leads and lifts and as per direction of Engineer-in-charge.
Providing and fixing pressed steel door, frames, manufactured from comercial mild steel sheet of 1.25 mm thickness including hinges jump block Jamb, beed, and if required angle threshold of mil steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or regidly fixed together by machanical means adjustable lugs with split and tails to each Jamb i/c steel but things 2.5mm thick with guards lock strike plate and shock as specified and applying a coat of applying steel primer after pretreatment of the surfaces directed by the Engineer-in-charge
Profile-A.
Profile-B.
Profile-C.
Providing and fixing Pannelled and glazed shutters for doors windows and clear storey windows including bright finish black enamel led iron butt hinges with necessary screws 40mm thick: 2nd class deodar wood within all leads and lifts and as per direction of Engineer-in-charge. .
P/F wire gause shutters using MS wire gause of IS gause designation 85 G for doors windows clerestorey windows I/c bright finished black enamelled iron hinges with necessary secrews 30 mm thick 2nd class deodar wood within all leads and lifts and as per direction of Engineer-in-charge. .
15 mm thick cement plaster on fair sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)within all leads and lifts and as per direction of Engineer-in-charge.
20 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand) within all leads and lifts and as per direction of Engineer-in-charge.
6 mm thick cement plaster in CM 1:3( 1cement 3 sand in roof slabs within all leads and lifts and as per direction of Engineer-in-charge.
White washing with lime on undecorated wall surfaces(two coats) to give an even shade I/c thoroughly brooming the surface to remove all dust dirt & other foreign matter within all leads and lifts and as per direction of Engineer-in-charge. .
Distempering (two coats) with oil bond distemper of approved brand and manufacture and of required shade on undecorated surfaceto give an even shade and including priming coat with distemper after throughly brushing the surface free from mortar dropping and other foreign matters within all leads and lifts and as per direction of Engineer-in-charge. .
Finishing wall with water profing cement paint of approved brand and manufacture and of rerquired shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials within all leads and lifts and as per direction of Engineer-in-charge. .
Precast terrazo tiles 20m thick (with marble chipsof specified shadeand of specified laid in floor treads of steps and landingon bed on10mm thick cement plaster 1:6 (1cement6sand) jointed withneat cement slurry mixed with pigment to match the shade of tiles. selvary grey within all leads and lifts and as per direction of Engineer-in-charge.
For floor
In Skirting & riser ofsteps and dado incement plaster 1:3 (1cement:3sand) and jointed with white slurry within all leads and lifts and as per direction of Engineer-in-charge. . Selvary grey
Applying priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil grease & dirt and other foreigm matter within all leads and lifts and as per direction of Engineer-in-charge.
Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters white paint within all leads and lifts and as per direction of Engineer-in-charge.
Painting two coats(excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matters other than white paint within all leads and lifts and as per direction of Engineer-in-charge.
Providing and fixing of MS grill of required patttern in wooden frame of window etc. with MS rounded headed bolts and nuts or by screw: Plain Grill within all leads and lifts and as per direction of Engineer-in-charge. .
Stone soling properly hand packed filling interstices with spalls and consolidating with power road roller to the required gradient and camber including spreading watering and rolling of binding materials moorum or earth etc. 100mm spread thickness (finished work including materials and labour) within all leads and lifts an da directed by the Engineer-in-charge.
Providing and fixing anodized Mild Steel sliding door bolts withnuts and screws complete within all leads and lifts and as per direction of Engineer-in-charge. I) 250mmX16mm
Providing and fixing anodized mild steel. tower bolts barrel type with screws etc. complete within all leads and lifts and as per direction of Engineer-in-charge.
I) 200mmX10mm
ii) 150mmx10mm
Providing and fixing anodized mild steel.handles with screws etc. complete within all leads and lifts and as per direction of Engineer-in-charge. .
I)125mm dia
ii) 100mm dia
Providing 40x3 mm flat iron hold fast 40cm. Long including fixing to frame with 10mm dia metres bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm. 1:3:6( 1cement:3sand:6 graded stone att. 20mm nominal size) within all leads and lifts and as directed by the Engineer-in-charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6graded stone agg. 20mm nominal size) i/c finishing the top surface of concrete smooth within all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying brick tiles over mumty roofs grouted with cement mortar 1:3 over a 12mm layer of cement mortar 1:3 and finished needly within all leads and lifts and as directed by the Engineer-in-charge.
ELECTRICAL Wiring for light point/exhaust fan point/call bell point wire 2.5 sqmm. PVC Insulated heat resistant flame retardent (HRFR)and low smoke single core (flexible)copper conductor cable in surface/recessed PVC conduit and earthing the light point with 2.5 sq.mm.HRFRLS/PVC insulated single core copper conductor cable as required within all leads and lifts and as per direction of Engineer-in-charge. Group C.
Wiring for light point/exhaust fan point/call bell point wire 1.5 sqmm. PVC Insulated heat resistant flame retardent (HRFR)and low smoke single core (flexible)copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5sq.mm.HRFRLS/PVC insulated single core copper conductor cable as required within all leads and lifts and as per direction of Engineer-in-charge.. Group C.
Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (s) of all sizes and shapes,complelte with all accessories but excluding CFL lamp including making connections, testing etc. within all leads and lifts and as per direction of Engineer-in-charge as required. a)Fixed type wall bracket 150 dia, single lamp (Catgegory-A).
a) Wiring for power plug with 24x4 sqm.mm PVC insulated heat retardant (HRFR) and low smoke single core (flaxible) copper conductor cable in surface /recessed PVC conduit alongwith 1 No. 4 sq mm HRFRLS /PVC insulated single core copper conductor cable of same size for earthing as required within all leads and lifts and as per direction of Engineer-in-charge.
b) Wiring for power plug with 4x4 sqm.mm PVC insulated heat retardant (HRFR) and low smoke single core (flaxible) copper conductor cable in surface /recessed PVC conduit alongwith 1 No. to 4 Sq. mm HRFRLS /PVC insulated single core copper conductor cable for earthing as required within all leads and lifts and as per direction of Engineer-in-charge.
Wiring for circuit / subman with following size PVC insulated flame retardant (HRFR) and low smoke single core (flaxible) copper conductor cable in surface /recessed PVC conduit alongwith 1 No. to 4 Sq. mm HRFRLS /PVC insulated single core copper conductor cable for earthing as required within all leads and lifts and as per direction of Engineer-in-charge.= 2x1.5 Sq.mm
Supplying and fixing matel box of 100 mmx100mmx60mm deep (nominal size) on surface / reacess with suitable sizephenolic laminated sheet over in the front including providing and fixing 5 pin 5/6 amps. socket outlet and 5/6 amp. piano type switch, connections, painting etc. as required within all leads and lifts and as per direction of Engineer-in-charge.
Supplying and fixing matel box of 180 mmx100mmx60mm deep (nominal size) on surface / reacess with suitable sizephenolic laminated sheet over in the front including providing and fixing 6 pin 15/16 amps. socket outlet and 15/16 amp. piano type switch, connections, painting etc. as required within all leads and lifts and as per direction of Engineer-in-charge.
Supply and fixing Ding-Dong / Electronic musical bell suitable for DC/AC single phase 230 volts complete in all respect within all leads and lifts and as per direction of Engineer-in-charge.
Supply and fixing TP & N switch disconnector fuse unit cubical type 415/500 volts with 3 No. HBC/HRC fuses in steel sheet enclosure including drilling holes on the board, connections earthing the body etc. as required suitable for DC/AC single phase 230 volts complete in all respect.
40 Amp. Cat-A
Supplying and erection of 40/50/63 amp. Rating 10 KA breaking capacity 240 volts"C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connection etc within all leads and lifts and as per direction of Engineer-in-charge.
Single pole Cat-A
Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recess complete with tinned copper bus bar wire set, neutral link, earth bar, din bar,detachable gland plate, interconnections, phosphatized and powder painted,including earthing etc. as required within all leads and lifts and as per direction of Engineer-in-charge :
a) Double door 8 way.
Providing and installation of following type of utra slim decorative LED batton make of Philips, Syska, GE Bajaj or equelent with extruded aluminium heat sink with anti glare polycarbonate diffuser and energy constant intergral electronic driver suitable for input voltege AC 220-240 V 50/60 HZ complete with all accessories within all leads and lifts and as per direction of Engineer-in-charge.
P/Inst. & testing and commissioning of ceiling fan 140mm sweep Cat. A within all leads and lifts and as per direction of Engineer-in-charge.
DEEP CHAND SHARMA
SAI GLOBAL NATURE CARE
HYDRAULIC ENGINEERING COMPANY
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .