Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹21.0 L+₹1.8 L (9.25%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | Rejected-Technical VILLAGE DEORA P O PACHAUR DIST SINGRAULI M P 486886 | SINGRAULI | MADHYA PRADESH | 486886 | - | Rejected-Technical Not R being not enlisted in requisite cat. | |
| 4 | Rejected-Technical | - | Rejected-Technical Not R being not enlisted in requisite cat. | |
| 5 | Rejected-Technical | - | Rejected-Technical Not R being not enlisted in requisite cat. |
Tender Value
₹23.1 L
EMD Value
₹46,500
Closing Date
5 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S Pradeep
MES, HQ CWE Jammu PIN-900172
PROVN OF ARBORICULTURE WORK FOR OTM ACCN OF MED REGT AT KALUCHAK MIL STN UNDER GE KALUCHAK
2025_MES_707109_1
CWE/JP-05/2025-26
Open Tender
Civil Works - Others
Item Rate
120 days
GE Kaluchak
As per tender documents
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹46,500
Yes
26 Jul 2025
8 May 2025
7 Jun 2025
8 May 2025
5 Jun 2025
22 May 2025
8 May 2025 - 11 May 2025
Amount
Excavation in over areas not exceeding 1.5m deep and getting out in soft/loose soil complete all as specified and as directed.
Removing excavated material exceeding 1.5km but not exceeding. 5km including watering, lavelling complete all as specified and as directed.
Stacking of good earth obtained from excavation of soil including cleaning sieving & carriage spreasing and neatly levelling within a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or /and manure before and after flooding trench with water (excluding the cost of imported sludge or manure).complete all as specified and as directed.
Surface excavation of earth not exceeding. 30cm deep averaging and 15cm, deep, to including cleaning away all grass, vegetation, shrubs, roots and trees not exceeding. 30cm grith and removing rubbish only up to a distance of 50mt outride the periphery of area under clearance complete all as specified and as directed.
Supply and mixing properly manure /cowdung with the excavated earth to make mixture of earth and manure in a ratio of 2:1 and surface dressing the area to a true level and required slope for grass plantation or to make plant/flower bebs complete all as specified and as directed.
Digging holes in soft/loose soil and refilling the same with mixture of clean earth and manure/ cowding in ratio of 2:1 including watering, dressing , levelling etc complete all as specified and as directed.
Above 60 cm upto 100 cm dia and 100 cm deep complete all as specified and as directed.
Upto 60 cm dia and upto 60 cm deep complete all as specified and as directed.
Plantation of Rose,bougainvillea, more pankh,hedge, curtain creeper, jasmine,candani, Gandharaj,chameli, Devil's trumpet,dwarf lady palm, fiscus Black plant bonsai tree japanease art Tree (Size 2 to 3 Feet) including preparation of Plant Bed including Manuring and watering complete all as specified and as directed.
All as per description Srl Item No 08 but mango,guava,amla,sapote, litchi, jamun, sagwan, palm, popular,sirusTrees (size 3 to 4 feet) complete all as specified and as directed.(20 Each Plant)
Supply and mixing Spreading insecticides as and when required, chloropyriphos 20% EC complete all as specified and as directed.
Supply and mixing Flooding ground/lawn, flower beds, plant surroundings etc including necessary arrangement to retain water in the area, if required, and removing of vegetable and grass in the area complete all as specified and as directed.
Lawn/ground complete all as specified and as directed.
Plant beds/flower beds complete all as specified and as directed.
Designer machine cut marble fountain of 7 feet height including 3x thalis of dia 3 feet, 2 feet and 1.5 feet including brick masonary in cement mortar 1:4 using Sub Class 'B' bricks water tank of size 8 feet x 8 feet 1.5 feet (octagonal shape) with marble clading on all the sides including waterproof decorative 4 Nos light and pipe nozles etc and including all necessary excavation, removal of soil, marble work for side and bottom. (Therates are inclusive of all material, labour and T&P etc copleted in all respect to make the foutain functional complete all as specified and as directed.)
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and as directed.
PCC (1:4:8), Type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
Granite stone Z black or any other colour as approved by GE, machine cut and polished, 15 to 18mm thick as in veneering / cladding of columns, walls and soffits of slab etc. fixed with chemical adhesive over and including 10mm thick rendering in cement mortar 1:3 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including machine grinding and polishing complete all as specified and as directed.
Rendering 15 mm thick in cement mortar 1:4 on external brick or concrete surfaces complete all as specified and as directed.
Boulder( 80 to 150mm aggregate) filling dry, handpacked tightly, as in fountain complete all as specified and as directed.
Machine Pressed precast concrete interlocking paver block any shape and size M-35 Grade, 60mm thick conforming to IS-15658-2006 with grey cement and pigments laid over 50mm thick sand cushioning, complete all as specified and as directed. (Note :Sand cushioning shall be measured and paid separately.)
75mm thick cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as sub base complete all as specified and as directed.
Sand filling under floors or cushioning to paver block including watering and consolidation complete all as specified and as directed.
Washed stone grit plaster on exterior walls in two layer, under layer 12mm cement plaster 1:4 (1 cement:4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per Sqm metre,top layer 15mm cement plaster 1:1/2 :2 (1cement:1/2 coarse sand :2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and as directed.
Supply , installation , commissioning and testing of treated water transfer pumpmotor set 5 HP, 415 volts,50HZ consisting of Mono block pumps set (one working & one standby) to transfer STP treated water for arboriculture uses, having discharge 200 LPM at a head of 36 metre suitable for delivery pipe 50 mm bore complete all as specified and as directed.
Submersible pump set suitable of 240 V ,single phase system having capacity 0.5 HP capable to deliver, 50-100 LPM at a head of 10-15 mtr complete all as specified and as directed.
Submersible pump set suitable of 240 V ,single phase system having capacity 1.0 HP,capable to deliver, 50-100 LPM at a head of 10-15mtr complete all as specified and as directed.
Sprinkler(Mannual) poptype of height 4 inch min throw radius 17 feet with adjustable arc to 0 to 360 degree of tough material recommeded pressure 2.5 bar of 32/20mm size and made of polyethiline tough materials complete all as specified and as directed.
LED underwater Light, colorful multicoloured IP 68 with waterproof underwater Lamp suitable for water fountain only complete all as specified and as directed.
GI tubing of 50 mm bore 'medium grade' with all fittings and fixed complete laid in trenches complete all as specified and as directed.
GI tubing of 40 mm bore 'medium grade' with all fittings and fixed complete laid in trenches complete all as specified and as directed.
GI tubing of 25 mm bore 'medium grade' with all fittings and fixed complete laid in trenches complete all as specified and as directed.
GI tubing of 20 mm bore 'medium grade' with all fittings and fixed complete laid in trenches complete all as specified and as directed.
Gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe of 50 mm bore complete all as specified and as directed.
Gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe of 40 mm bore complete all as specified and as directed.
Gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe of 20 mm bore complete all as specified and as directed.
Supply only PVC pipe of 25 mm dia complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exc 1.5 Mtr deep in any type of soil and getting out and levelling of bottom surface to required level for poles/stay assembly/cable complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25m thick complete all as specified and as directed.
Removing excavated material from site to a distance not exceeding 50mtr away and depositing where directed not exceeding 1.5mtr from the starting point complete all as specified and as directed.
Feeder pillar box cublcal type, out door vermin free, factory fabricated, veritical standing, made out of 2.50 mm thick MS sheet with bottom frame and standing legs made out of 40x40x3 mm angle iron, weather proof, vermin proof with slopped roof, hinged door front opening with locking arrangements complete with bus bar 60 Amps for three phase and neutral suitable for 3 phase 415 V AC four wire system suitable for fixing MCBs, motor starters, volt meter, ammeters including suitable PCC foundation etc comprising in and including the following complete all as specified and as directed.
MCB TP 4 pole 63 Amps capacity having breaking capacity 10 KA 'C' curve -1 No (incoming) complete all as specified and as directed.
MCB TP 25 Amps capacity having breaking capacity 10 KA 'C' curve - 1 No (for pump) complete all as specified and as directed.
Motor starter DOL 3 PHASE in sheet steel enclosure suitable for electric motor pump set 5 HP capacacity type with relay range 9-15 Amps -2 No complete all as specified and as directed.
MCB DP 20 Amps capacity having breaking capacity 10 KA 'C' curve - 3 Nos (for lights) complete all as specified and as directed.
Ammeter 0 -20 Amps CT poperated -1 No Digital complete all as specified and as directed.
Voltmeter 0 - 500 V -1 No Digital complete all as specified and as directed.
Cable XLPE Insulated screened,PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade, with aluminium conductor of size 10 Sqmm, 4 core. complete all as specified and as directed.
Cable XLPE Insulated screened,PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade, with aluminium conductor of size 10 Sqmm, 2 core. complete all as specified and as directed.
Replacement sheet metal enclosure double door type for MCB DBs, SPN 2 way 240 V, complete flush mounted all as specified and as directed.
Cutting of existing GI/CI Pipe line of size 150/100 mm in position for addn/alteration or insertion of branch connection/Tee complete with excavation. Returning filling,removal,cutting,existing GI/CI Pipe line threading or drilling/bore in pipe line complete with MS clamp and jointing material i.e. Tee ,nipple MS clamp all as site requirement complete all as specified and as directed.
Construction of 230mm thick brick masonary valve chamber built in cement mortar1:6 for valve pit of size (600x600x600mm) internal dimentions with 100mm thick foundation using PCC 1:4:8 type D2 with 100mm offset 15mm thick plastering internally and 15mm thick plastering externally in cement mortar1:6 up to 15 cm below GL, 3mm thick MS sheet cover ,double door welded to 50mmx50mmx6mm MS angle iron frame fixed with hold fasts in PCC 1:23:4 type B1, coping 50mm thick with PCC 1:2:4 type B1,20mmx6mm flat iron hinges with locking arrangements including lock 65mm brass and keys,MS handles and applying one coat of red oxide primer and two coats of synthetic enamel paint too all steel surfaces including excavation and earth work in any type of soil and disposal of surplus soil to a distance not exceeding 50mtr complete all as specified and as directed.
Earthing complete with galvanised steel pipe electrode, 600 x 600 x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to galvanised earthing lead of 4 mm dia of iron or steel wire all as shown in electrical plate No. 5 all as specified and as directed. Note :- the cost of excavation and earth work PCC pit and CI cover funnel & watering pipe of 40 mm dia, wiremesh, charcoal dust and common salt shall be deemed included in the unit rate for earthing complete all as specified and as directed.
M/S RAKESH CONSTRUCTION (BID ID -3304830)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .