Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | ₹40.0 L | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹45.7 L+₹5.7 L (14.1%)Rejected-Finance | ₹45.7 L+₹5.7 L (14.1%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹55.6 L+₹15.6 L (39.0%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹55.6 L+₹15.6 L (39.0%) | L3 | Rejected-Finance Not being lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
16 Jun 2025, 6:00 pmClosed
GARRISON ENGINEER I Rnd D WEST BANGALORE
GARRISON ENGINEER I RndD WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
PROVISION OF SOLAR STREET LIGHT IN MTRDC RESIDENTIAL AREA AND TECHNICAL AREA ROOF TOP SOLAR PANELS 40KW ON GRID POWER PLANT AT ALISDA TECHNICAL COMPLEX JALAHALLI AREA AND CEILING SUSPENDED TYPE CASSETEE AND SPLIT AIR CONDITIONING WORK AT CAIR ETCUN
2025_MES_705251_1
GE(I)/R ND D (WEST)/BAN/TOKEN/05 OF 2025-26 8369/E8
Open Tender
Civil Works
Item Rate
180 days
Work
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER I Rnd D WEST BANGALORE
₹96,000
9 Jul 2025
10 May 2025
23 Jun 2025
12 May 2025
16 Jun 2025
3 Jun 2025
12 May 2025 - 26 May 2025
Amount
PROVISION OF SOLAR STREET LIGHT IN MTRDC RESIDENTIAL AND TECHNICAL AREAS
Supply and fix all in one solar power street lights 60W with PV module with the following BIS certified Lithium Ferro Phospate battery 12.8V 24AH, IEC certified solar Charger controllar, MNRE/BIS approved polycry stalline solar panel 60WP di-cast aluminium metal stand LED light lumens 150/Watt , motion sensor with IP-67system design and connected items etc complete all as specified and ditrected by Engineer-in-charge Make : CG/Bajaj/ Havells
Suplly and errect 06 Metre Pole hot dip galvanized octagonal pole confirming of BSEN 10025 & galvanization BS EN ISO 1461 or equivalent with 3mm sheet thickness and &65 micron with confirming windspeed 47 m/s. Pol should be of 70mm top dia and 130mm bottom dia The pole should have inbuilt door mounting 500mm above from ground with proper gasket & alien key arrangment M16x600mm J bolts and baseplate of 220x220mmwith a 12mm thickness including excavation and PCC foundation etc complete all as specified and ditrected by engineer-in-charge
Supply, Erection, Testing, synchronizing and commissioning on grid connected rooftop solar BIS certified and MNRE ALMM Regisitered, DCR Mono Crystalline Non PERC 144 half cut cells solar PV module/panels suitable for installation on roof tops with each panel having capacity not less than 540/550 Wp, complete with poly carbonate junction boxes, having sufficient number of fused incomers and outgoing terminals (positive/negative) suitable for 6 sqmm cables and connecting cables not less than 4.0 Sqmm copper conductor multistranded (solar cross linked poly olefin cables double insulated, UV resistant halogen free low smoke ) from panel to panel all as specified and directed. The solar modules shall confirm to the latest edition of any of following IEC/Equivalnat BIS Standards for PV module design qualification and type approval as per IEC 61215 Edition II. IEC 61646,IEC 62804 and IEC 61730-1,2, IS 14286, , additionaly the performance of PV modules must be tested and approved by on of the IC/NABL accredited testing laboratories including Solar Energy Center. In additional the module must confirm to IEC 61730- Part I (A1 + A2 + A11) - requirement for construction & Part II (+A1) - requirements of testing as per IEC 60068-2-68 The solar modules shall have the following Technical specification and shall comprise of as under :- Panel Brand : Waaree/ Adani/ Renewsts/ saatvik
(a) Output power (Pmax) 540/ 550Wp or above (b). Module Efficiency: Not less than 90% (c). Number of cells: 144 half cut (d). Maximum System Voltage: 1500 Vdc (e). Application Class - A (t). Fire Class - A (g) Fire Rating Class - C (h) Junction Box: IP 67, 1.5 kV minimum 400mm length cable as per IEC 60529 & IEC 62790: 2020
(i). Type of PV Cell: PERC Mono Crystalline Silicon ). Module Glass transmission shall be > 93 % (k). Glass Thickness shall be min 3.2 mm (i). Bypass diode for optimizing PV out to be incorporated in each solar module (m). Module Output: MC Electronic Plug (n). Modules only with Same rating and manufacturer shall be connected. (o). Solar Module must have IV curve Test report in NABL Lab for the specifed wattage
(p) Design including Civil work such as PCC/RCC foundation/Electrical infrastructure metricularly carried out by contractor as per the required output plant (0.5 MW) and duly vetted from govt approved authority of NIT/IT and Approval by Garrison Engineer before execution at site. The contractor shall carry out shadow analysis at the site and accordingly design strings and arrays layout considering optimal usage of space, material and labour
(q) Each PV module must have RFID TAG (this can be inside or outside the laminate, but must be able to withstand harsh environmental conditions) which contains Name of manufacture of PV module, solar cells & month and year of manufacturing.country of origin(seperately for solar cells & modules), I-V curve for module wattage, Im, Vm, FF, Unique serial No & model of the module, Name of test lab issuing EC certificate, other relevant information on traceability of solar cells and modules as per ISO 9001 & 14001. (r) Both the cells and modules shall be mado in india. (l) Manufactures has to be in ALMM (Aproved List for Models) & Manufacturer) registered of MNRE (s) Power Warranty - Minimum 90% of output of rated power(315 KWp) after 10 years and minimum 80% of output of rated power(315 KWp) after 25 years (t) All panels should be verified with Domestic content Requirement(DCR) verification portal.
(lii Cost of miscellaneous component such as termination kits lugs, shine boards, conduits, MC4 for connectors Adopter box and other connected accessories etc shall be deemed to be included in the cost of Modules.
Rate quoted by the contractor shall be inclusive of the supply of spares as required from time to time for scheduled and preventive maintenance, major overhauling of the plant, replacement of defective modules and its attending for a period of 2 years: (v) Rate quoted shall be inclusive of any items which have not been mentioned in the schedule but which are necessary for the design, supply & performance or completeness of the 40 Kw SPV plant.
Supply and install minimum IP65 rated On grid string inverter, 40 Kw ( 3ph 415 Volt With Power Point Tracking) Solis/growatt/sungrow/deye natural cooled, suitable for ambient temperature range 0 to 60 deg Celsius, 50 Hz frequency, with islanding protection features, grid frequency tolerance range +3 or more, grid volatage tolerance -20% & +15%, No Load losses <1% of rated power, THD<3%, PF > 0.8, having three phase AC output with inbuilt surge protection devices, Anti reverse power controller, fuse protection, DC/AC switches, LCD display for generating data, Wifi/GPRS data logger, multiple MPPT for optimum generation, wide input voltage range, efficiency not less than 93% etc for capacity range not less than 40KW and upto 49 KW all as specified and directed by engineer in charge. Note :- (i) Inverter will be fixed on the wall with galvanum sheet of suitable size with necessary accessories to protect from rain will be deemed to be included in quoted rate. (ii) Inverters should be tested from the MNRE approved test centres/NABL/BIS/IEC accredited testing calibration laboratories. (iii) The warranty of inverter shall be five years. (iv) Suitable rain protection shed with structural steel members and CGI/PGI sheet top roofing shall be provided and cost of same is included in quoted rate.
Design, Supply and install prefabricated roof top solar panel mounting structure made of Hot dip galvanized mild steel angles/channels/flats including nuts/bolts and washers suitable for wind resistance upto 80 KMPH including necessary PCC/RCC foundations of grade Type B1 - 1:2:4 using 20 mm graded stone aggregate at suitable points to provide for a stable robust support all as directed at site all as specified and directed including designing of Suitable mounting structure for SPV Module and shall be provided as per design critirea considering live load, dead load, wind load and as per condition of roof slabs/ foundation of existing Bldgs etc by a approved structural Engineer and vetted by NIT/IIT and approval by Garrison Engineer before execution at site as per IS 2061-1992, IS 2062/IS 4759/AA 60636 all as specified and as directed.
(a) Structures shall be of flat-plate design using minimum size of C (40 X 80 X 40 x 3mm) or L (50 x 50 x 5mm) or l (60x 40x 4mm) sections or higher dimensions for respective sections. (b) Each structure with fixed tilt should have a tilt angle as per the site conditions to take maximum insolation which will be approximately equal to the latitude of the location facing true South with a North - South orientation. (c) The PV module mounting structure shall have a capacity to withstand a wind velocity of 80 KMPH unless specified for dedicated requirements. (d) The materials used for structures shall be Hot dip Galvanized Mild Steel conformed to IS 2062:1992. (e) The minimum thickness of galvanization for hot dip Galvanized Mild Steel should be at least 80 microns as per IS 4759.
(f) The Bolts, Nuts, fasteners, and clamps used for panel mounting shall be of Stainless-Steel SS 304 Grade. (9) Additional Structures/Frames for required for the installation of modules if any need to be provided by the Contractor. (h) The structures shall be designed to allow easy replacement of any module, repairing and cleaning of any module. (i) The structure shall be designed to withstand operating environmental conditions for a period of minimum 25 years and shall be free from corrosion while installation.
Supply and fixing of Direct Current Distribution Box with Surge Protective Device ,Fuse 1000 Volt 20 AMP, 4 IN 4 OUT. Supply and fix DC distribution boards(Array Junction Box), 1P65 protected, suitable for roof top solar power generating system of rating not less than 60KW, 1000 volts, 4 incomer and 4 outgoing with DC surge protection device 1000 V DC fuse and MCBs for string network. The DB will be having terminals suitable for 4 Sqmm copper conductor cables and the enclosure for the DB shall be made of powder coated MS with IP66 protection including suitable rain protection shed, all as specified and directed. Note - Suitable rain protection shed with structural steel members and CGI/PGI sheet top roofing shall be provided and cost of same is included in quoted rate.
Supply and fixing of Alternating Current Distribution Box With 4 pool MCA ,Surge Protective Device 1 IN 1 OUT.Supply and fixing AC Distribution Panel Board (DPB) - Outdoor type, double door, minimum IP65 Protected, necessary surge arrestors with following: (a) Incomer - 415V, 4P, 100,25 KA MCCB - 1 No(incomer from one invertor) (b) Outgoing - 415V, 4P, 100A,25 KA MCCB, adjustable type - 1 No( Outgoing to LT Panel) (c) Copper Busbar of 4P, 150 A (d) Outgoing feeder with Type I and Type II SPD ,4 Pole of capacity T1+T2- limp 8 KA/Pole Imax-32 KA (e) MFM Meter with suitable CTs (t) Double compression Glands for Input and output (g) Enclosure CRCA Powder Coated PU Paint (h) All Input and Output lugs (Cu & Al lugs as per cable type) Note - Suitable rain protection shed with structural steel members and CGI/PGI sheet top roofing shall be provided and cost of same is included in quoted rate.
Supply and fixing of DC Cable 4 sq mm Copper Multi Strand for Solar Pv module.etc complete all as specified and ditrected by engineer-in-charge
Supply and fixing of AC Cable 95 Sq mm Armoured Aluminium Cable Inverter To ACDB and ACDB TO Client Side.etc complete all as specified and ditrected by engineer-in-charge
Supply and fixing of Aluminium Lightning Arrester Spike 5 No’s Radiation 50 Mtr and Earthing kit Copper Road 2 Mtr , Chemical bag each bag 25 Kgetc complete all as specified and ditrected by engineer-in-charge.
Supply and fixing of Solar Meter Box CT, MCCB, Fuse, Changeover Switch With CT and Check Meter for Solar generation.etc complete all as specified and ditrected by engineer-in-charge
Supply and fixing of 11 KV HT Cubical Meter 3 phase 4 wire system 3 current transformers 3 voltage transformers, LBS 3 CT and 3 PT with HT Net Meter 3 Phase. Suitable for 40KW Roof top Solar Power generation plantetc complete all as specified and ditrected by engineer-in-charge
Power Purchase Agreement with BESCOME Listening work with Generation meter. Liaisoning with BESCOM authority for obtaining any relevent documents/approved of installation solar power plant to Grid from BESCOM for smooth functioning shall be contractor's responsibility. Rate quoted by contractor is inclusive of charges for feasbility clearance and Liaison work regarding the plant from starting to commissioning with BESCOM. Plant will be taken over after it is fully functional inculding Installation of Energy Reading meter and certified by BESCOM. Standby supply shall be provided by contractor without any extra cost to department at the time of Synchronizing with existing 11 KV sytem. Technical feasiblity report shall be obtained from BESCOM before starting work in ground.
Design, loading, transportation, unloading,Supply, inatallation Testing & Commissioning
Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6.3 mm thick buried in ground vertically to a depth not less than 2.25 metre below normal ground level, normal with top edge of earth plate not less than 1.5 metre below normal ground level, earth plate connected to a galvanised earth lead wire 4mm dia bymeans of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I (2009) connected to earth test point all as specified or indicated including testing on completion with and including 15 mm bore light grade GI protection pipe 7.5 meters long for earth including PCC 1:2:4 pit with pre cast RCC 1:2:4 type B1 cover 40 mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hook made out of 6mm dia MS bars watering arrange,ent with funnel wire, common salt and charcoal filling, necessary excavation and earth work in any type of soil complete all as specified.
Supply Install Testing and Commissioning inverter type 5 star rated adjustable type Hi wall split unit with indoor/outdoor of capacity 2.0 TR complete with cordless remote control unit, with in built filter as per latest manufactureres year for better indoor air quality complete all as directed. Note - Copper pipings with best insulation of required sizes, drain out PVC pipe and control cable of suitable rating upto 3 metre shall be included in the quoted rate.
Supply Install Testing and Commissioning of cassetter Acs 3 TR, 5 star inverter 3ph, with indoor/outdoor of capacity 3.0 TR, scroll compressor complete with cordless remote control unit, with in built filter three phase 415 volt 50 HZ as as per manufactureres 5 for better indoor air quality, in and including external voltage stabiliser of rating 5 KVA complete all as directed. Make:DAIKIN CAT No FCMF100 or equivalent in LG/Bluestar/carrier. Note for Sl No. 1 & 2 - Copper pipings with best insulation of required sizes, drain out PVC pipe and control cable of suitable rating upto 3 metre shall be included in the quoted rate, etc complete all as specified and ditrected by engineer-in-charge
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA etc complete all as specified and ditrected by engineer-in-charge
Supply and fixing ODU Bracket factory made powder coated suitable for 2.0 Ton AC out door unit etc complete all as specified and ditrected by engineer-in-charge.
Supply laying and testing copper piping 3/8 & 5/8 with insulation material complete all as directed and specified
Material and labour for core cutting in concrete walls/beams and making good disturbed surface complete all as directed and specified
Supply laying and testing copper cable 2.5 sq mm 4 core complete all as directed and specified
Supply laying and testing drain water piping with 20 mm PVC pipe complete all as directed
Supply and fix Industrial 3 pin metal clad plug & socket with 32A SP MCB complete all as directed and specified
M&L for wiring of circuit/ submain wiring 4 X 10 sq. mm + 2 X 10 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface medium class PVC conduit of suitable dia complete all as required
M&L for wiring of circuit/ submain wiring 4 X 6 sq. mm + 2 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface medium class PVC conduit of suitable dia complete all as required
Supplying and fixing 8 way, single pole and neutral, sheet steel, MCB distribution board 240V on surface/recess, complete with tinned copper bus bar neutral bus bar earth bar, din bar, interconnections, powder painted including earthing etc as required (But without MCB/RCCB/Isolator)
Supply and fix MCB 4 pole 100 Amps,415 Volt,50 Hz, not less than 25 KA using copper lugs for terminations complete with connections, testing and commissioning etc. all as specified and directed.
Supply and fixing MCB single pole 32A, 240V, 50Hz, 10 kA, 'C' curve suitable for inductive load complete with connections, testing and commissioning etc. all as specified and directed.
Supply and fix heavy duty exhaust fan metallic body AC single phase 230/240V 900 RPM of size 450mm sweep with necessary fittings etc. all as specified and directed.
Pacific Enterprises (BID ID -3317332)
Lucky Enterprises (BID ID -3325045)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .