Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹35.7 L+₹5.2 L (16.9%)Rejected-Finance | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹37.6 L+₹7.1 L (23.2%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance HIGHER | |
| 4 | L4₹37.8 L+₹7.3 L (24.0%)Rejected-Finance GURDASPUR ROAD NEAR SAINIK MANDIR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance HIGHER | |
| 5 | L5₹39.1 L+₹8.6 L (28.1%)Rejected-Finance | L5 | Rejected-Finance HIGHER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GE Amritsar
REPAIR REPLACEMENT OF LT OH LINE, UG CABLES AND CONNECTED ITEMS OF ELECTRIC SUPPLY IN THE AREA OF AGE BR-II UNDER GARRISON ENGINEER AMRITSAR CANTT
2024_MES_651600_1
GE/ASR-19/2024-25
Open Tender
Civil Works
Works
180 days
GE Amritsar
class D category b i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹90,000
22 Sept 2024
29 Apr 2024
28 May 2024
29 Apr 2024
27 May 2024
14 May 2024
Amount
Material and Labour for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 2 Mtr of tree both side of the OH line with JCB, Cutter and all tools, plants etc ; Complete all as specified and as directed by Engineer-in-Charge. Note : (i) Distance between pole to pole will be measured and paid. (ii) Contractor has to take outmost care to avoid damage to existing lines/structures. If any breakdown of line is caused during prunning shall be made good without any extra cost. (ii) Prunning of tree to be done twice a year (before & after rainy season) (iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occurs the contractor will be solely responsible for it.
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil and added additional 1.5 m or part thereof in depth beyond the first 1.5 mtr ; Complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on hard / dense soil and added additional 1.5 m or part thereof in depth beyond the first 1.5 mtr ; Complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil ; Complete all as specified and as directed by Engineer-in-Charge.
Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point ; Complete all as specified and as directed by Engineer-in-Charge.
Supply & laying HDPE pipe IS-16205 (part-24)ID-75 mm bore for laying of LT cables etc ; Complete all as specified and as directed by Engineer-in-Charge.
Supply & laying HDPE pipe IS-16205 (part-24)ID-95 mm bore for laying of LT cables etc ; Complete all as specified and as directed by Engineer-in-Charge.
Supply & laying HDPE pipe IS-16205 (part-24)ID-103 mm bore for laying of LT cables etc ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- 10 sqmm 4 Core, ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- 16 sqmm 4 Core, ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- 25 sqmm 4 Core, ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- 35 Sqmm 31/2 core, ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- 50 Sqmm 31/2 core, ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- 70 Sqmm 31/2 core, ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- 95 Sqmm 31/2 core, ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- 120 Sqmm 31/2 core, ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- 150 Sqmm 31/2 core, ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:- 300 Sqmm 31/2 core, ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for making good the damaged Tar Road by using additional stone metal, PCC etc ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for repairs of LT Panel board of any size with replacing the unserviceable MCCB,MCB,switch fuse unit , change over ,Busbar,etc jointig cable with proper lugs ,nut , bolt and washers, cleaning the panel by using of CRC Soluation and repairing thhe panel door by using hinges and repairing the lock system, welding etc painting the LT Panel wit one coat of primer & two coat of synthetic enamel paint as approved or as per direction of Engr-in-Charge. Note:(i) MCCB,MCB,Switch fuse unit and change over switch measured and paid separately. (ii) Labour for MCCB, MCB, Switch fuse unit and change over switch measured and paid separately. (iii)Rate of new Busbar, panel door, cable gland, lugs,CRC Solution,nut,bolt, painting etc and washers are deemed to be included in quoted rates.
Material and Labour for repairs of existing Amp meter (0-300Amp) by digital one along with unserviceable CT if any from existing LT Panel of any size ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for repairs of existing Volt meter 0 to 600 volt , digital type from existing LT Panel of any size, ; Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for painting of LT Steel tubular pole,9 mtr long with two coats of synthetic enamel paint including prepartion of surfaces,Scraping the old paint and writing pole No in Black letter under yellow circle ; Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for painting of LT Steel tubular pole,11 mtr long with two coats of synthetic enamel paint including prepartion of surfaces,Scraping the old paint and writing pole No in Black letter under yellow circle ; Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion ; Complete all as specified and as directed by Engineer-in-Charge. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates. iii) The earthing done in presence of JE /E-in-Charge will only be measured. iv) The material required for earthing will be first approved from E-in-charge before bulk procurement
Material and Labour for checking of HT UG 11 KV XLPE faulty cable with HT UG cable fault locating testing machine, rectifing the fault, putting the jointing kit and charging the cable as all as specified and directed. Approx length 500 RM for each Job. (The rate for excavation, removing of old cable, laying after repairs is demmed to be included in the rate quoted by the contractor).
Supply ,Installing, commissioning and testing in replacement LT bus bar, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 2 mm thick CRCA sheet and inner sheet of 2.0mm thick and angle iron frame of size 50x50x5mm inside depth not less than 50 cm and size suitable to accommodate the following accessories, with insulated alluminium busbar 400amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories ; Complete all as specified and as directed by Engineer-in-Charge. (a)MCCB 200 Amp four pole with Breaking Cap 25 KA-01 No (Incoming) (b) Volt Meter (digital Type (0 T0 600 Volts)-01 No (c ) Ammeter (digital type) with Cts 0-300Amps)-01 No (d) Phase indication lamps LED type with holder-01 Set(Set of Three)
Supply ,Installing, commissioning and testing in replacement LT bus bar, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 2 mm thick CRCA sheet and inner sheet of 2.0 mm thick and angle iron frame of size 50x50x5mm inside depth not less than 90 cm ( 45 cm grouted in PCC) and size suitable to accommodate the following accessories, with insulated alluminium busbar 200amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories all as directed. (a)MCCB 100 Amp four pole with Breaking Cap 25 KA-01 No (Incoming) (b) Volt Meter (digital Type (0 T0 600 Volts)-01 No (c Ammeter (digital type) with Cts 0-300Amps)-01 No (d Phase indication lamps LED type with holder-01 Set(Set of Three)
Supply ,Installing, commissioning and testing in replacement LT panel board, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 3.15 mm thick CRCA sheet and inner sheet of 2.0mm thick and angle iron frame of size 50x50x5mm inside length not less than 90 cm (45 cm grouted in PCC) and size suitable to accommodate the following accessories, with insulated alluminium busbar 400amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories ; Complete all as specified and as directed by Engineer-in-Charge. (a)MCCB 250 Amp four pole with thermal magnetic setting with Breaking Cap 25 KA-01 No (Incoming) (b) MCCB TPN 100 Amps 4P with thermal magnetic setting with breaking cap 25KA - 02Nos (For Out Going) (c) MCCB 63 Amps (4 pole ) with thermal magnetic setting with breaking capacity 25 KA -04 Nos (For Out Going) (d) Volt Meter (digital Type (0 T0 600 Volts)-01 No (e) Ammeter (digital type) with CTs 0-300Amps)-01 No (f) Phase indication lamps LED type with holder-01 Set(Set of Three) Notes:- 1. The Panel Should be approved by CPRI. 2) The rates Rate Quoted shall include for earth work and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0..45 M from GL to the bottom of panel board.
Material and Labour for LT cable end joint heat shrinkable suitable for 10 Sqmm 4 core to 25 Sqmm 3.5 core cable ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for LT cable end joint heat shrinkable suitable for 35 Sqmm 4 core to 70 Sqmm 3.5 core cable ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for LT cable end joint heat shrinkable suitable for 95 Sqmm 4 core to 120 Sqmm 3.5 core cable ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for LT cable end joint heat shrinkable suitable for 150 Sqmm 4 core to 300 Sqmm 3.5 core cable ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and install LT steel tubular pole 9.0 mtr long type 410, SP-31 complete with excavation and PCC for foundation incl coping ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for finding UG cable fault by excavation and repairing the cable of various sizes with straight through joint and returning refiiling of trenches and removal of extra soil from site complete complete all as directed for the following :- LT cable 3.5/4 core 10 sqmm to 35 Sqmm incl straight through joint ( Note - excavation and earth work will be measured and paid seaparately )
Material and Labour for finding UG cable fault by excavation and repairing the cable of various sizes with straight through joint and returning refiiling of trenches and removal of extra soil from site complete complete all as directed for the following :- LT cable 3.5 core 50 sqmm to 95 Sqmm incl straight through joint ( Note - excavation and earth work will be measured and paid seaparately )
Material and Labour for finding UG cable fault by excavation and repairing the cable of various sizes with straight through joint and returning refiiling of trenches and removal of extra soil from site complete complete all as directed for the following :- LT cable 3.5 core 120 sqmm to 185 Sqmm incl straight through joint ( Note - excavation and earth work will be measured and paid seaparately )
Material and Labour for finding UG cable fault by excavation and repairing the cable of various sizes with straight through joint and returning refiiling of trenches and removal of extra soil from site complete complete all as directed for the following :- LT cable 3.5 core 240 sqmm to 300 Sqmm incl straight through joint ( Note - excavation and earth work will be measured and paid seaparately )
Supply only Insulating mats as per IS-15652 of thickness 2.0 mm ; Complete all as specified and as directed by Engineer-in-Charge.
Attending breakdown complaint of OH conducrtors of any size and repairing the conductor by using additional conductor of same size for fixing on poles incl binding wire etc ; Complete all as specified and as directed by Engineer-in-Charge. ( Note - All T&P required for attending the complaint incl safety devices will be the contractors responsibility)
Material and Labour for dismantling of OH conductor of any size ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for dismantling of crossarms ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for dismantling of insulators ; Complete all as specified and as directed by Engineer-in-Charge.
Supply only silica gel for transformer breathers ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for maintanance of ACB of capacity 630 to 1000 Amps any make incl repalcement of minor parts , shunt coil , over/ under voltage coil , cleaning of contacts eith CTC and tighteing of all connections ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for ACSR conductor any size ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs MCCB 4 pole 27 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 63/100Amps ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs MCCB 4 pole 27 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 125 Amps ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs MCCB 4 pole 27 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 160 Amps ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs MCCB 4 pole 36 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 200 Amps ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs MCCB 4 pole 36 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 250 Amps ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs MCCB 4 pole 36 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 400 Amps ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs MCCB 4 pole 36 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 630 Amps ; Complete all as specified and as directed by Engineer-in-Charge.
Bharat Builder
kailu construction co
SAINI AND SAINI BUILDERS
M/S BALWINDER SINGH
SUN MANN ENGINEERS
UNITED ENGINEERING CORPORATION
Northern cable fault locatoers
dinesh enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .