NAVIN KUMAR
ED - Gurgaon
Special repair to E.I. in old block of Women College at sector 16 Faridabad
2024_HRY_342738_1
202461D2C5B9 DBEA 4CE6 91F4 014F336F10B2664BAR
Open Tender
Electrical Works
Works
90 days
Faridabad (MC)
2 documents required · 2 mandatory
₹1,000
₹31,700
Yes
1 Jul 2024
9 Jan 2024
16 Jan 2024
9 Jan 2024
15 Jan 2024
9 Jan 2024
Amount
COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS Wiring only in 1.5 sqmm PVC insulated copper conductor cable for LIGHT/FAN/Call bell point in existing conduit pipe and MS boxes including cost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connector etc. Group B
Wiring only in existing conduit and MS box for Twin control light point with 2 nos , 2-ways, 5 amp. switch in 1.5 sqmm FRLS PVC insulated copper conductor cable . Group B
Wiring in existing conduit and MS box for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch etc complete as required Group B
Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etc complete as required Group B
MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia.
MS pipe of 25 mm dia.
FITTING AND ACCESSORIES Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Ceiling rose flush/surface type
Electric buzzer 220/230 volts A.C. Bakelite with double coil.
Socket size rotary step type Electronic regulator for A.C. ceiling fan
Supply and Fixing 3 mm thick Bakelite sheet cover on existing MS/PVC junction box/tee etc including fixing with brass screws and washers.
Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.
Providing and fixing outdoor duty Ply of 8 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required.
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. Triple pole MCCB 16 to 100 Amp, 25 KA
Triple pole MCCB 200 to 250 Amp, 25 KA
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)
Vertical TPN DB Double Door 8 way ( 8 incoming 3phase*8 outgoing)
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
6 amp. to 32 amp MCB's Triple Pole
6 amp. to 32 amp MCB's Four Pole
40 amp to 63 amp. MCB's Four Pole
SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 200 amp 415 volts
Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100 X 50 X 1.6 mm3
Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in charge of the work. GI cable tray cover suitable for cable tray of 100*50*2 mm
DISMANTLING Dismantling old wiring points ( Recess wiring or partly recess partly surface system , recess Conduit and box not to be dismantled ) including necessary repairs to wall etc. Light, fan or call bell Point including circuit/sub main wiring
Wall socket point including circuit/submain wiring
EARTHING AND LIGHTENING ARRESTOR Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
Supply & erection of 32mm dia P.mtr. 1.5 m long bracket (B-class) making an angle of 10° to 15° with horizontal plane for mounting street light fitting fixing on GI. bracket on wall with 2 nos. 32 mm x 3 mm thick M.S. clamps including cost of cutting, welding of G.I. pipe complete with cement sand mixture, bolts and nuts etc. including necessary connections.
Supply & erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe complete in all respect upto the entire satisfaction of Engineer in charge of the work 1.5 sq.mm
Supply & erection of under ground cable in pipe/ existing open / closed trench complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work 35 Sq. mm 3.5 Core armoured Cable .
50 Sq. mm 3.5 Core armoured Cable .
70 Sq. mm 3.5 Core armoured Cable .
95 Sq. mm 3.5 Core armoured Cable .
Supply and erection of 1 no. 12 way moduler box made of G.I. sheet with inner & outer plate including cost and fixing of 3 nos. sockets and 3 nos. switches of 5 amp and 1 no. multi socket and switch of 15 amp, M.S. box duly recessed in wall, cost of necessary cement and sand mixture making necessary connection complete in all respect upto the entire satisfaction of Engineer-in-charge of work. (for computer point )
Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
Supply and erection of 70/72 watts LED street light fittng with lense, minimum 100 lumes per watt IP 66, HP dia cast aluminium hoising including erection of same on pole with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer - In- Charge.
MANYA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .