RMO of SPS, street lights, fire fighting system, fire alarm system, IEI, PA System, CCTV System, EPABX System and Fire Extinguishers at community hall in different pockets i.e A,B-1,B-2,C and D and DDA Project office (Loknayakpuram) Bakkarwala.
2026_DDA_905760_1
03/EE (E)/ELD-10/DDA/2026-27
Open Tender
Electrical Works
Works
365 days
EE(E)/ELD-10/DDA
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹37,951
29 Apr 2026
17 Apr 2026
24 Apr 2026
17 Apr 2026
23 Apr 2026
17 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Running Maintenanc & Operation of fire fighting system,fire alarm system & PA system and CCTV System, EPABX System & IEI at community hall in different pockets i.e A,B-1,B-2,C & D & DDA Project office (Loknayakpuram ) Bakkarwala as per inventory attached.
i) Wireman-1 No. 52 days (once in a week and whenever is required)
ii) Khallasi - 1 No. 52 days (once in a week and whenever is required). | 12 | P/month | - | - |
| - | Running Maintenance & Operation of sewage pump sets and CCTV system at Sewage Pump House as per inventory,terms and conditions attached.
i) Wireman-1 No. 52 days (once in a week and whenever is required)
ii) Khallasi - 1 No. 52 days (once in a week and whenever is required).
iii) Pump operator GR-II- 2 Nos. ( 6:00 AM to 2:00 PM and 2:00 PM to 10:00 PM and whenever is required) | 12 | P/month | - | - |
| - | Running,operation & Maintenance of existing street lights on upto 12 mtr height poles complete with feeder pillers,switchgears,pole boxes, copper wires & distribution cables etc in various locations as per inventory with tower and wagon whenever required .
i) Wireman -1 No. 104 days (twice in a week and whenever is required)
ii) Khallasi - 1 No. 104 days (twice in a week and whenever is required). | 12 | P/month | - | - |
| - | Repairing of 40 HP Sewage Pump Set i/c Supply & Replacement of following worn out part i/c dismantling & reconnection complete etc as required.
S/R of of shaft Sleeve-1No.
S/R of of Ball Bearing -2 No.
S/R of of S.S Shaft -1 No
S/R of of Impleller Nut -1 No
S/R of of Gland dori -1 No | 1 | Job | - | - |
| - | Repairing of 75 HP Sewage Pump Set i/c Supply & Replacement of following worn out part i/c dismantling & reconnection complete etc as required.
S/R of of shaft Sleeve-1No.
S/R of of Ball Bearing -2 No.
S/R of of S.S Shaft -1 No
S/R of of Impleller Nut -1 No
S/R of of Gland dori -1 No | 1 | Job | - | - |
| - | Repairing of 100 HP Sewage Pump Set i/c Supply & Replacement of following worn out part i/c dismantling & reconnection complete etc as required.
S/R of of shaft Sleeve-1No.
S/R of of Ball Bearing -2 No.
S/R of S.S Shaft -1 No
S/R of of Impleller Nut -1 No
S/R of of Gland dori -1 No | 1 | Job | - | - |
| - | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
400 Amp | 1 | Each | - | - |
| - | Dismantling and rewinding the existing burntout 3 phase 3HP submersible pump set in the existing borewell i/c dismantling the existing delivery line,valves etc and lowering the same i/c connections, testing etc complete with followings as required.
(i)Motor winding kit-1No. (ii)Bearing Bush-4No(iii)water seal-2No.(iv)E.P stage bowl(v)E.P.Impeller | 1 | Each | - | - |
| - | LED Flood Light, powder coated pressure die cast aluminium(System lumen efficacy ≥120 and <135 lm/Watt).Supplying,Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separatedriver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 Hz,Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as perIEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electricalcircuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 200 watt (DSR.2025 8.15.5) | 5 | Each | - | - |
| - | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with70% of initial Lumen maintained till life ends as per LM80extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation ColourMatching) <5, Maximum power consumption should not more than
the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable andearthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test reportand all testing required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a)150 Watt
(DSR 2025- 8.13.17) | 20 | Each | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.63 MB
Tendernotice_2.pdf
PDF • 2.32 MB
BOQ_952056.xls
BOQ • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .