Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC 107 1A TOLLYGAUNG ROAD KOLKATA 700026 WB | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹49.0 L+₹2.1 L (4.48%)Rejected-Finance 107 1F TOLLYGUNGE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹49.9 L+₹3.1 L (6.52%)Rejected-Finance 197 PATHAK PARA ROAD KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹52.1 L+₹5.2 L (11.1%)Rejected-Finance 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹53.2 L+₹6.3 L (13.4%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹42.6 L
EMD Value
₹85,200
Closing Date
6 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW)Kolkata
D-9, COMMISSARIAT ROAD, HASTINGS, KOLKATA - 700 022
PROVN OF PCC HARDSTANDING/PATH IN GE (FW) KOLKATA AND FROM KP-3 TO KP-1 AND PROVN OF PATHWAY NEAR EAST GATE TUNNEL INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2021_MES_466642_3
GE(FW)/KOL/8767/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW)Kolkata
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE(FW)Kolkata
₹85,200
Yes
3 Nov 2021
29 Sept 2021
7 Oct 2021
29 Sept 2021
6 Oct 2021
29 Sept 2021
60 days
Amount
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Returning filling in incl spreading , levelling , watering and well ramming in layers not exc 25 cm as in soft/ loose Soil, complete all as Specified and as directed.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and directed.
M&L for Hardcore with broken stones, of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Rolling and consolidation to required gradient and camber of formation surface (in cutting or filling) of roads with 8 to 10 tonne power roller including watering as necessary and consolidating to the required level, gradient or camber, keeping roller wheels wet, if required, filling in hollows and depressions which occur during rolling and provision of water, road roller, drivers, crew, fuel, labour, tools, etc complete all as specified and directed.
M&L for forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.50M high from base complete all as specified and directed. NOTES:- (i) Earth obtained from excavation under this work or within 50 metres lead from site inside MOD land shall be used for the work. (ii) Payment shall be made for nett quantity after compaction, worked out based on initial levels and finished levels as specified. (iii) Deduction for voids in terms of Para 3.6 of SSR Part-II 2010 shall be made from the final qty worked out from the initial and finished levels.
Bringing approved earth from outside Ministry of Defence (MOD) land and forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.50M high from base complete all as specified and directed. NOTES:- (i) Payment shall be made for nett quantity after compaction, worked out based on initial levels and finished levels as specified. (ii) Deduction for voids in terms of Para 3.6 of SSR Part-II 2010 shall be made from the final qty worked out from the initial and finished levels. (iii) Sample of Earth to be bought in shall be got approved by GE in writing by the contractor before bringing in the earth required under this item. (iv) Earth shall be brought from outside MOD land only after the surplus earth obtained from excavation under this work has been used and requirement of earth still persists. (v) In case of the soil obtained from excavation under this work is found unsuitable for filling, the same shall be removed from site as per directions of the Engineer-in-Charge and proper documentation & photographic evidence for the same shall be kept on record.
M&L for plain cement concrete 1:3:6 type C1, using 20 mm graded crushed stone aggregates as in filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B2, using 40 mm graded crushed stone aggregates as in filling and mass concrete complete all as specified and directed.
M&L for Pavement Quality Concrete (PQC) of minimum field flexural strength 40 Kg/Sq cm after 28 days in pavement slab using not less than 400 Kg of cement per cum of concrete with crushed stone aggregate of grading as specified, laid in panels including necessary formwork, spread and compacted using mechanical paver, mechanically vibrated and bull nosing/rounding off edges, curing, brooming and belting etc, average thickness 250 mm and top layer treated with non-metallic, monolithic surface hardening compound, as per manufacturer's instructions and finished even and fair with wooden float or power trowels complete all as specified and directed. MAKE OF HARDENING COMPOUND: FOSROC (Nitoflor Hardtop Standard) or equivalent item in other approved makes specified in tender. NOTES : 1. Quoted rate shall be deemed to include cost of mix design for PQC from any Govt approved laboratory/Engg College. 2. Deduction shall be made for the volume of expansion joint.
M&L for forming 20 mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, depth of joint shall be full depth of PQC slab i.e 250 mm complete all as specified and directed.
M&L for forming dummy/construction joints 65mm deep x 10mm wide, filled with sealing compound grade 'A' complete all as specified and directed.
S&F 18-20 mm thick granite slab, in floors etc, cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pavement to match the shade of granite stone incl grinding and polishing over and including 15 mm screed bed in cement mortar (1:4) complete all as specified and directed.
S&F cast iron rain water socket pipes, without ears, conforming to IS:1230-1979, 100 mm bore, fixed with cement joints complete all as specified and directed.
S & F 100 mm bore CI bends or elbow square for CI rain water pipes complete all as specified and directed.
M&L Brick Work with Sub-Class ‘B’ fly-ash Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M & L for half brick with sub class 'B' fly-ash bricks straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and directed.
M&L for 10mm thick rendering on fair faces of brickwork or concrete surfaces in cement mortar 1:4 finished rendering surfaces even and smooth without using extra cement including necessary scaffolding etc complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished rendering surfaces even and smooth without using extra cement including necessary scaffolding etc complete all as specified and directed.
Supply and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. (NOTE: Cost of sand cushioning is deemed to be included in the quoted rates)
Supply and laying 200 mm bore reinforced concrete pipe of Class NP-3, laid and jointed with jute & cement mortar 1:2, complete with collars all specified and as directed.
All as per Item No. 24 above, but 300 mm bore RCC pipe
M&L concrete bed to drain pipe including packing under and haunching against the side of drain pipe after laid and tested in PCC 1:3:6 type C2 for 200 mm bore pipes complete all as specified and directed.
All as per Item No. 26 above, but for 300 mm bore pipe
M&L for PCC (1:2:4) type 'B-1' (using 20mm graded crushed stone aggregate) as in floor, plinth protection etc, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for PCC (1:2:4) type 'B-1' (using 20mm graded crushed stone aggregate) as in sub base of concrete finished even and fair cement complete all as directed..
S & F in repair 450mm dia 50mm thick RCPC man hole cover with frame of 540mm dia, 100mm thick of 3MT capacity fixed in proper position incl taking out existing cover complete all as specified and directed.
S&F in repair RCPC (Reinforced Cement Polymer Concrete) grating slab of size 600 mm x 450 mm x 100 mm thick, of Capacity 3 MT fixed in proper position complete as directed by Engr-in -Charge.
Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area exc 400 sqm, not exc 50 mm deep complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1, using 20 mm graded stone aggregate, as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M & L for Providing precast cement concrete Type B1 1:2:4 (20mm graded aggregate) Set in cement mortar 1:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including necessary forms, moulds, etc complete all as specified and as directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M&L mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cracking, bending, spirally for hopping for columns hookings ends and binding with and incl mild steel wire (annealed) not less the 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No. 35 but 6 - 8 mm dia
M&L for Cement Concrete type B-1, (1:2:4) using 20mm graded crushed stone aggregate in copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including use and waste formwork (straight or curved) complete all as specified and as directed.
Supply and laying factory made precast cement concrete cobble blocks, 60 mm thick, of M-35 grade with approved colour & design, laquer finished, as in footparth, lawns, drive ways, etc., of required strength, thickness & size/shape, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of cobbles into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of cobble blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. (NOTE: Cost of sand cushioning is deemed to be included in the quoted rates)
S&F in position, at or near ground level, factory made precast cement concrete kerb stone blocks, in M-25 grade cement concrete, fixed to the required line, level and curvature, jointed in cement mortar 1:3, including making joints with or without grooves (thickness of joints, except at sharp curves shall not be more than 5 mm) including making drainage opening wherever required complete all as specified and directed.
M&L for applying two coats of cement base paint over a coat of alkali resistant primer, on new plastered walls, as per manufacturer's instructions complete all as specified and as directed.
S.M.CONSTRUCTIONS
JAGATMATA ENTERPRISE
ARATI TRADING CO
MS AP CONSTRUTION AND CO
PINKY CO.
MAZUMDER ENTERPRISE
UNIVERSAL TRADING CENTRE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .